Salaheddine Sta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Salaheddine Sta has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Chafiaa Hamitouche
IMT‐Atlantique Bretagne‐ Pays de la Loire Brest France
1 shared publicationEric Stindel
LaTIM INSERM SFR IBSAM Brest France
1 shared publication- Guillaume Dardenne
LaTIM UMR 1101, Inserm, Brest, France
1 shared publication - Hoel Letissier
Department of Orthopaedic and Traumatology Surgery, CHU de la Cavale Blanche, boulevard Tanguy-Prigent, 29200 Brest, France; Faculté de Médecine, Université Bretagne Occidentale, 22, rue Camille-Desmoulins, CS 93837, 29238 Brest cedex 3, France
1 shared publication Jérôme Ogor
LaTIM INSERM SFR IBSAM Brest France
1 shared publication
Latest Publications
- 3 June 2021
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 17 (5) , e2296
Towards markerless computer assisted surgery: Application to total knee arthroplasty
Purpose: A new approach is proposed to localise surgical instruments for Computer Assisted Orthopaedic Surgery (CAOS) that aims at overpassing the limitations of conventional CAOS solutions. This approach relies on both a depth sensor and a 6D pose estimation algorithm.Methods: The Point‐Pair Features (PPF) algorithm was used to estimate the pose of a Patient‐Specific Instrument (PSI) for Total Knee Arthroplasty (TKA). Four depth sensors have been compared. Three scores have been computed to assess the performances: The Depth Fitting Error (DFE), the Pose Errors, and the Success Rate.Results: The obtained results demonstrate higher performances for the Microsoft Kinect Azure in terms of DFE. The Occipital Structure core shows better behavior in terms of Pose Errors and Success Rate.Conclusion: This comparative study presents the first depth‐sensor based solution allowing the intraoperative markerless localization of surgical instruments in orthopedics.
- 3 June 2021
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 17 (5) , e2296
Towards markerless computer assisted surgery: Application to total knee arthroplasty
Purpose: A new approach is proposed to localise surgical instruments for Computer Assisted Orthopaedic Surgery (CAOS) that aims at overpassing the limitations of conventional CAOS solutions. This approach relies on both a depth sensor and a 6D pose estimation algorithm.Methods: The Point‐Pair Features (PPF) algorithm was used to estimate the pose of a Patient‐Specific Instrument (PSI) for Total Knee Arthroplasty (TKA). Four depth sensors have been compared. Three scores have been computed to assess the performances: The Depth Fitting Error (DFE), the Pose Errors, and the Success Rate.Results: The obtained results demonstrate higher performances for the Microsoft Kinect Azure in terms of DFE. The Occipital Structure core shows better behavior in terms of Pose Errors and Success Rate.Conclusion: This comparative study presents the first depth‐sensor based solution allowing the intraoperative markerless localization of surgical instruments in orthopedics.