Agharza Ashurov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Agharza Ashurov has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Argyrios Chronopoulos
Department of Ophthalmology, Ludwigshafen City Hospital, Ludwigshafen am Rhein, Germany
1 shared publication - Carl Arndt
Department of Ophthalmology, University Hospital of Reims, 51100 Reims, France
1 shared publication - James Scott Schutz
Department of Ophthalmology, University Hospitals and School of Medicine, Geneva, Switzerland
1 shared publication - Julia Heim
Department of Ophthalmology, Hospital of Ludwigshafen, Teaching Hospital of the University of Johannes Gutenberg-University Mainz and Medical Faculty of the University of Mannheim, 67063 Ludwigshafen, Germany
1 shared publication - Lars-Olof Hattenbach
Augenklinik des Klinikums Ludwigshafen, Ludwigshafen, Deutschland
1 shared publication Melanie Hundhammer
Universitäts-Augenklinik, Universitätsklinikum Gießen und Marburg GmbH, Standort Marburg, Marburg, Deutschland
1 shared publication
Latest Publications
- Open Access
- 10 October 2022
- Published by MDPI AG in Clinics and Practice
- Vol. 12 (5) , 818-825
Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface
Purpose: We investigated intraoperative OCT (iOCT)—guided epiretinal membrane (ERM) and internal limiting membrane (ILM) removal using a novel forceps with a laser-ablated tip surface; it was designed to help prevent indentation force, shear stress, or tractional trauma when grasping very fine membranes. Patients and Methods: This retrospective study included patients who underwent 23- and 25-gauge pars plana vitrectomy (PPV) for vitreoretinal interface disorders. ERM and ILM peeling was performed under guidance with microscope-integrated iOCT using novel ILM forceps with laser-ablated tip surfaces. These forceps were engineered to enhance friction when grasping tissue. Evaluation of ERM/ILM manipulation included postoperative slow-motion video analysis of the number of grasping attempts, initial ILM mobilization, and observed damage to retinal tissue. Results: ERM/ILM removal was successfully performed in all patients, with an average of four grasp actions to initial membrane mobilization (91%). Additional use of a diamond-dusted membrane scraper was used in two cases (9%). Mean best-recorded visual acuity (BRVA) logMAR improved from 0.5 ± 0.34 to 0.33 ± 0.36 (p = 0.05) and mean central retinal thickness (CRT) improved from 462 ± 146 µm to 359 ± 78 µm (p = 0.002). Postoperative iOCT video analysis demonstrated hyper-reflectivity of the inner retinal layers associated with retinal hemorrhage in five eyes (22%), but no grasping-related retinal breaks. Conclusions: The texturized surface on the tips of the ILM forceps were found to be helpful for mobilizing ILM edges from the retinal surface. iOCT-guided ERM surgery also allowed for improved intraoperative tissue visualization. We believe that these two technologies helped reduce both unnecessary surgical maneuvers and retinal damage.
- 10 October 2022
- Published by MDPI AG in Clinics and Practice
- Vol. 12 (5) , 818-825
Open AccessReal-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface
Purpose: We investigated intraoperative OCT (iOCT)—guided epiretinal membrane (ERM) and internal limiting membrane (ILM) removal using a novel forceps with a laser-ablated tip surface; it was designed to help prevent indentation force, shear stress, or tractional trauma when grasping very fine membranes. Patients and Methods: This retrospective study included patients who underwent 23- and 25-gauge pars plana vitrectomy (PPV) for vitreoretinal interface disorders. ERM and ILM peeling was performed under guidance with microscope-integrated iOCT using novel ILM forceps with laser-ablated tip surfaces. These forceps were engineered to enhance friction when grasping tissue. Evaluation of ERM/ILM manipulation included postoperative slow-motion video analysis of the number of grasping attempts, initial ILM mobilization, and observed damage to retinal tissue. Results: ERM/ILM removal was successfully performed in all patients, with an average of four grasp actions to initial membrane mobilization (91%). Additional use of a diamond-dusted membrane scraper was used in two cases (9%). Mean best-recorded visual acuity (BRVA) logMAR improved from 0.5 ± 0.34 to 0.33 ± 0.36 (p = 0.05) and mean central retinal thickness (CRT) improved from 462 ± 146 µm to 359 ± 78 µm (p = 0.002). Postoperative iOCT video analysis demonstrated hyper-reflectivity of the inner retinal layers associated with retinal hemorrhage in five eyes (22%), but no grasping-related retinal breaks. Conclusions: The texturized surface on the tips of the ILM forceps were found to be helpful for mobilizing ILM edges from the retinal surface. iOCT-guided ERM surgery also allowed for improved intraoperative tissue visualization. We believe that these two technologies helped reduce both unnecessary surgical maneuvers and retinal damage.
- 4 June 2021
- Published by Springer Nature in Der Ophthalmologe
- Vol. 119 (2) , 170-175
Ursachen und Risikofaktoren für eine erneute Netzhautablösung nach Silikonölentfernung bei verschiedenen vitreoretinalen Grunderkrankungen
Zusammenfassung Hintergrund Trotz einer Silikonölendotamponade kann es bei einer komplizierten Netzhautablösung zu einem Rezidiv noch unter Öl oder unmittelbar nach Entfernung der Öltamponade kommen. Fragestellung Ziel dieser Studie ist es, Risikofaktoren für eine rezidivierende Ablösung zu benennen sowie die funktionellen und anatomischen Ergebnisse zu untersuchen. Methoden Retrospektive Analyse von Patienten mit primärer Ablatio retinae, die an der Universitäts-Augenklinik Marburg zwischen 2010 und 2015 eine Pars-plana-Vitrektomie (ppV) mit Silikonöltamponade erhalten und im weiteren Verlauf eine Reablatio erlitten haben. Dabei wurden 2 Gruppen gebildet: Gruppe 1 hatte eine Reablatio unter Öl, Gruppe 2 eine Reablatio direkt nach Ölentfernung. Ergebnisse Es wurden insgesamt 43 (15,6 %) Fälle identifiziert, in 22/43 Fällen (50 %) zu einer Reablatio nach Ölentfernung und in 21/43 Fällen (7,6 %) zu einer Reablatio unter Silikonöltamponade. Als Ursache für erneute Ablatio wurde in 90,6 % (39/43) der Fälle eine proliferative Vitreoretinopathie (PVR) angegeben, neue Foramina wurden in 20,9 % (9/43), persistierende Foramina in 25,5 % (11/43) ermittelt. Schlussfolgerung Die vitreoretinale Narbenbildung (PVR-Reaktionen) waren der Hauptrisikofaktor für eine erneute Netzhautablösung. Auch persistierende Foramina wurden als häufigerer Grund benannt. Eine erneute Netzhautablösung stellt eine bedeutende Herausforderung sowohl für Patienten als auch vitreoretinale Chirurgen unter Berücksichtigung der wirtschaftlichen und emotionalen Belastung durch mehrfache Eingriffe dar.
- 4 June 2021
- Published by Springer Nature in Der Ophthalmologe
- Vol. 119 (2) , 170-175
Ursachen und Risikofaktoren für eine erneute Netzhautablösung nach Silikonölentfernung bei verschiedenen vitreoretinalen Grunderkrankungen
Zusammenfassung Hintergrund Trotz einer Silikonölendotamponade kann es bei einer komplizierten Netzhautablösung zu einem Rezidiv noch unter Öl oder unmittelbar nach Entfernung der Öltamponade kommen. Fragestellung Ziel dieser Studie ist es, Risikofaktoren für eine rezidivierende Ablösung zu benennen sowie die funktionellen und anatomischen Ergebnisse zu untersuchen. Methoden Retrospektive Analyse von Patienten mit primärer Ablatio retinae, die an der Universitäts-Augenklinik Marburg zwischen 2010 und 2015 eine Pars-plana-Vitrektomie (ppV) mit Silikonöltamponade erhalten und im weiteren Verlauf eine Reablatio erlitten haben. Dabei wurden 2 Gruppen gebildet: Gruppe 1 hatte eine Reablatio unter Öl, Gruppe 2 eine Reablatio direkt nach Ölentfernung. Ergebnisse Es wurden insgesamt 43 (15,6 %) Fälle identifiziert, in 22/43 Fällen (50 %) zu einer Reablatio nach Ölentfernung und in 21/43 Fällen (7,6 %) zu einer Reablatio unter Silikonöltamponade. Als Ursache für erneute Ablatio wurde in 90,6 % (39/43) der Fälle eine proliferative Vitreoretinopathie (PVR) angegeben, neue Foramina wurden in 20,9 % (9/43), persistierende Foramina in 25,5 % (11/43) ermittelt. Schlussfolgerung Die vitreoretinale Narbenbildung (PVR-Reaktionen) waren der Hauptrisikofaktor für eine erneute Netzhautablösung. Auch persistierende Foramina wurden als häufigerer Grund benannt. Eine erneute Netzhautablösung stellt eine bedeutende Herausforderung sowohl für Patienten als auch vitreoretinale Chirurgen unter Berücksichtigung der wirtschaftlichen und emotionalen Belastung durch mehrfache Eingriffe dar.