    Detection of Non-Sustained Supraventricular Tachycardia in Atrial Fibrillation Screening

    by Hesam Halvaei, Tove Hygrell, Emma Svennberg, Valentina D.A. Corino, Leif Sörnmo, Martin Stridh

    Objective: Non-sustained supraventricular tachycardia (nsSVT) is associated with a higher risk of developing atrial fibrillation (AF), and, therefore, detection of nsSVT can improve AF screening efficiency. However, the detection is challenged by the lower signal quality of ECGs recorded using handheld devices and the presence of ectopic beats which may mimic the rhythm characteristics of nsSVT. Methods: The present study introduces a new nsSVT detector for use in single-lead, 30-s ECGs, based on the assumption that beats in an nsSVT episode exhibits similar morphology, implying that episodes with beats of deviating morphology, either due to ectopic beats or noise/artifacts, are excluded. A support vector machine is used to classify successive 5-beat sequences in a sliding window with respect to similar morphology. Due to the lack of adequate training data, the classifier is trained using simulated ECGs with varying signal-to-noise ratio. In a subsequent step, a set of rhythm criteria is applied to similar beat sequences to ensure that episode duration and heart rate is acceptable. Results: The performance of the proposed detector is evaluated using the StrokeStop II database, resulting in sensitivity, specificity, and positive predictive value of 84.6%, 99.4%, and 18.5%, respectively. Conclusion: The results show that a significant reduction in expert review burden (factor of 6) can be achieved using the proposed detector. Clinical and Translational Impact: The reduction in the expert review burden shows that nsSVT detection in AF screening can be made considerably more efficiently.


  • ECG Modeling for Simulation of Arrhythmias in Time-Varying Conditions

    by Lorenzo Bachi, Hesam Halvaei, Cristina Pérez, Alba Martín-Yebra, Andrius Petrėnas, Andrius Sološenko, Linda Johnson, Vaidotas Marozas, Juan Pablo Martínez, Esther Pueyo, et al.

    The present article proposes an ECG simulator that advances modeling of arrhythmias and noise by introducing time-varying signal characteristics. The simulator is built around a discrete-time Markov chain model for simulating atrial and ventricular arrhythmias of particular relevance when analyzing atrial fibrillation (AF). Each state is associated with statistical information on episode duration and heartbeat characteristics. Statistical, time-varying modeling of muscle noise, motion artifacts, and the influence of respiration is introduced to increase the complexity of simulated ECGs, making the simulator well suited for data augmentation in machine learning. Modeling of how the PQ and QT intervals depend on heart rate is also introduced. The realism of simulated ECGs is assessed by three experienced doctors, showing that simulated ECGs are difficult to distinguish from real ECGs. Simulator usefulness is illustrated in terms of AF detection performance when either simulated or real ECGs are used to train a neural network for signal quality control. The results show that both types of training lead to similar performance.


  • Open Access

    Signal Quality Assessment of a Novel ECG Electrode for Motion Artifact Reduction

    by Hesam Halvaei, Leif Sörnmo, Martin Stridh

    Background: The presence of noise is problematic in the analysis and interpretation of the ECG, especially in ambulatory monitoring. Restricting the analysis to high-quality signal segments only comes with the risk of excluding significant arrhythmia episodes. Therefore, the development of novel electrode technology, robust to noise, continues to be warranted. Methods: The signal quality of a novel wet ECG electrode (Piotrode) is assessed and compared to a commercially available, commonly used electrode (Ambu). The assessment involves indices of QRS detection and atrial fibrillation detection performance, as well as signal quality indices (ensemble standard deviation and time–frequency repeatability), computed from ECGs recorded simultaneously from 20 healthy subjects performing everyday activities. Results: The QRS detection performance using the Piotrode was considerably better than when using the Ambu, especially for running but also for lighter activities. The two signal quality indices demonstrated similar trends: the gap in quality became increasingly larger as the subjects became increasingly more active. Conclusions: The novel wet ECG electrode produces signals with less motion artifacts, thereby offering the potential to reduce the review burden, and accordingly the cost, associated with ambulatory monitoring.


  • Open Access

    Identification of Transient Noise to Reduce False Detections in Screening for Atrial Fibrillation

    by Hesam Halvaei, Emma Svennberg, Leif Sörnmo, Martin Stridh

    Screening for atrial fibrillation (AF) with a handheld device for recording the ECG is becoming increasingly popular. The poorer signal quality of such ECGs may lead to false detection of AF, often caused by transient noise. Consequently, the need for expert review in AF screening can become extensive. A convolutional neural network (CNN) is proposed for transient noise identification in AF detection. The network is trained using the events produced by a QRS detector, classified into either true beat detections or false detections. The CNN and a low-complexity AF detector are trained and tested using the StrokeStop I database, containing 30-s ECGs from mass screening for AF in the elderly population. Performance evaluation of the CNN-based quality control using a subset of the database resulted in sensitivity, specificity, and accuracy of 96.4, 96.9, and 96.9%, respectively. By inserting the CNN before the AF detector, the false AF detections were reduced by 22.5% without any loss in sensitivity. The results show that the number of recordings calling for expert review can be significantly reduced thanks to the identification of transient noise. The reduction of false AF detections is directly linked to the time and cost spent on expert review.


  • Open Access

    False Alarm Reduction in Atrial Fibrillation Screening

    by Hesam Halvaei, Emma Svennberg, Leif Sornmo, Martin Stridh