Bing Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bing Wang has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- John Charles Crittenden
Tianjin University
5 shared publications - Haifeng Pan
School of municipal and environmental engineering, Shenyang Jianzhu University, Shenyang, China
2 shared publications - Haipei Wang
Shenyang Jianzhu Univ, Sch Municipal & Environm Engn, Shenyang 110000, Peoples R China
2 shared publications - Haipei Wang
School of municipal and environmental engineering, Shenyang Jianzhu University, Shenyang, China
2 shared publications Haiyu Cheng
School of Municipal and Environmental Engineering Shenyang Jianzhu University Shenyang China
2 shared publications- Kaihang Zhang
Brook Byers Institute of Sustainable Systems and School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
2 shared publications
Latest Publications
- Open Access
- 2 June 2026
- Published by Wiley in ChemistrySelect
- Vol. 11 (21) , e73603
Magnetic CoFe 2 O 4 ‐Modified Hydrochar Derived From Wheat Straw for Peroxymonosulfate Activation: Efficient Methylene Blue Degradation and Radical Mechanism
Advanced oxidation processes based on peroxymonosulfate (PMS) activation have attracted considerable attention for the treatment of dye‐containing wastewater. However, conventional Fe‐Co/PMS systems still suffer from limited PMS activation efficiency and poor catalyst recoverability. In this study, a magnetic CoFe 2 O 4 ‐modified hydrochar catalyst derived from wheat straw was developed for PMS activation and methylene blue (MB) degradation. Alkali modification and the introduction of an additional carbon source enriched the hydrochar with active sites and oxygen‐containing functional groups, thereby facilitating MB enrichment near the CoFe 2 O 4 active centers. Meanwhile, the supported CoFe 2 O 4 provided Fe‐Co redox sites for PMS activation and endowed the catalyst with magnetic recoverability, enabling efficient PMS‐mediated MB degradation and catalyst reuse. After optimization of the reaction conditions, the MHTC/PMS system achieved a maximum MB removal efficiency of 99.8%. After five consecutive reuse cycles, the MHTC/PMS system maintained an MB removal efficiency of 68.8% and a chemical oxygen demand (COD) removal efficiency of 60.65%. Radical quenching experiments and electron paramagnetic resonance analysis revealed that MB degradation in the MHTC/PMS system proceeded through both radical and non‐radical pathways, with SO 4 · − playing the dominant role, followed by 1 O 2 and . OH. The intermediate products and possible degradation pathways were further identified by LC–MS analysis.
- 2 June 2026
- Published by Wiley in ChemistrySelect
- Vol. 11 (21) , e73603
Open AccessMagnetic CoFe 2 O 4 ‐Modified Hydrochar Derived From Wheat Straw for Peroxymonosulfate Activation: Efficient Methylene Blue Degradation and Radical Mechanism
Advanced oxidation processes based on peroxymonosulfate (PMS) activation have attracted considerable attention for the treatment of dye‐containing wastewater. However, conventional Fe‐Co/PMS systems still suffer from limited PMS activation efficiency and poor catalyst recoverability. In this study, a magnetic CoFe 2 O 4 ‐modified hydrochar catalyst derived from wheat straw was developed for PMS activation and methylene blue (MB) degradation. Alkali modification and the introduction of an additional carbon source enriched the hydrochar with active sites and oxygen‐containing functional groups, thereby facilitating MB enrichment near the CoFe 2 O 4 active centers. Meanwhile, the supported CoFe 2 O 4 provided Fe‐Co redox sites for PMS activation and endowed the catalyst with magnetic recoverability, enabling efficient PMS‐mediated MB degradation and catalyst reuse. After optimization of the reaction conditions, the MHTC/PMS system achieved a maximum MB removal efficiency of 99.8%. After five consecutive reuse cycles, the MHTC/PMS system maintained an MB removal efficiency of 68.8% and a chemical oxygen demand (COD) removal efficiency of 60.65%. Radical quenching experiments and electron paramagnetic resonance analysis revealed that MB degradation in the MHTC/PMS system proceeded through both radical and non‐radical pathways, with SO 4 · − playing the dominant role, followed by 1 O 2 and . OH. The intermediate products and possible degradation pathways were further identified by LC–MS analysis.
- 14 August 2024
- Published by Wiley in ChemistrySelect
- Vol. 9 (31)
Optimized Electrocatalytic Adsorption Degradation of Oilfield Produced Water Using New Dimension Stable Anode
In this study, we synthesized a novel electrode for electrocatalytic adsorption by fabricating ACF‐TiO 2 via the sol‐gel method and binding it with IrO 2 ‐TaO 2 . The electrode's effectiveness in treating oilfield produced water (OPW) was evaluated using batch techniques. Comprehensive characterization, including scanning electron microscopy (SEM), energy‐dispersive spectrometry (EDS), Brunauer‐Emmett‐Teller (BET) analysis, and Fourier‐transform infrared (FTIR) spectroscopy, confirmed uniform TiO 2 loading onto the ACF surface, preserving structural integrity. BET analysis indicated increased mesopore volume and enhanced organic adsorption capacity without compromising microporous structure. Additionally, FTIR analysis revealed the emergence of functional groups conducive to adsorption and catalytic reactions. Freundlich isotherms and pseudo‐first‐order kinetics best fit the adsorption data. Remarkably, even after five cycles, the electrode maintained high removal efficiencies for chemical oxygen demand (COD) and oil content at 91.35 % and 91.12 %, respectively. We further investigated the complex phenomena of material adsorption, electrochemical oxidation, and desorption during electrocatalytic adsorption, highlighting the importance of solid‐phase adsorption and liquid‐phase electrocatalytic oxidative decomposition in OPW treatment. Comparison with similar electrodes and DSA electrodes demonstrated the superior performance and practicality of the IrO 2 ‐TaO 2 ‐ACF(TiO 2 ) electrode. Its cost‐effectiveness and regeneration method further enhance its applicability in real‐world scenarios, emphasizing its potential in water treatment.
- 14 August 2024
- Published by Wiley in ChemistrySelect
- Vol. 9 (31)
Optimized Electrocatalytic Adsorption Degradation of Oilfield Produced Water Using New Dimension Stable Anode
In this study, we synthesized a novel electrode for electrocatalytic adsorption by fabricating ACF‐TiO 2 via the sol‐gel method and binding it with IrO 2 ‐TaO 2 . The electrode's effectiveness in treating oilfield produced water (OPW) was evaluated using batch techniques. Comprehensive characterization, including scanning electron microscopy (SEM), energy‐dispersive spectrometry (EDS), Brunauer‐Emmett‐Teller (BET) analysis, and Fourier‐transform infrared (FTIR) spectroscopy, confirmed uniform TiO 2 loading onto the ACF surface, preserving structural integrity. BET analysis indicated increased mesopore volume and enhanced organic adsorption capacity without compromising microporous structure. Additionally, FTIR analysis revealed the emergence of functional groups conducive to adsorption and catalytic reactions. Freundlich isotherms and pseudo‐first‐order kinetics best fit the adsorption data. Remarkably, even after five cycles, the electrode maintained high removal efficiencies for chemical oxygen demand (COD) and oil content at 91.35 % and 91.12 %, respectively. We further investigated the complex phenomena of material adsorption, electrochemical oxidation, and desorption during electrocatalytic adsorption, highlighting the importance of solid‐phase adsorption and liquid‐phase electrocatalytic oxidative decomposition in OPW treatment. Comparison with similar electrodes and DSA electrodes demonstrated the superior performance and practicality of the IrO 2 ‐TaO 2 ‐ACF(TiO 2 ) electrode. Its cost‐effectiveness and regeneration method further enhance its applicability in real‐world scenarios, emphasizing its potential in water treatment.
- 28 February 2024
- Published by Springer Nature in International Journal of Environmental Science and Technology
- Vol. 21 (11) , 7717-7732
Enhanced treatment of oily wastewater through modified magnetic seeds for magnetic flocculation
- 28 February 2024
- Published by Springer Nature in International Journal of Environmental Science and Technology
- Vol. 21 (11) , 7717-7732
Enhanced treatment of oily wastewater through modified magnetic seeds for magnetic flocculation
- Open Access
- 17 January 2023
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 9 (2) , 655
Correction: Improved VRC-3R− model for bulk water residual chlorine decay in the UV/Cl2 process for a water distribution network
Correction for ‘Improved VRC-3R− model for bulk water residual chlorine decay in the UV/Cl2 process for a water distribution network’ by Haipei Wang et al., Environ. Sci.: Water Res. Technol., 2023, 9, 308–330, https://doi.org/10.1039/D2EW00647B.
- 17 January 2023
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 9 (2) , 655
Open AccessCorrection: Improved VRC-3R− model for bulk water residual chlorine decay in the UV/Cl2 process for a water distribution network
Correction for ‘Improved VRC-3R− model for bulk water residual chlorine decay in the UV/Cl2 process for a water distribution network’ by Haipei Wang et al., Environ. Sci.: Water Res. Technol., 2023, 9, 308–330, https://doi.org/10.1039/D2EW00647B.
- 1 December 2022
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 9 (1) , 308-330
Improved VRC-3R− model for bulk water residual chlorine decay in the UV/Cl2 process for a water distribution network
The combination of UV irradiation and chlorine (UV/Cl2), as a new and efficient process, has been widely applied in drinking water disinfection. In this study, an improved VRC-3R− (variable rate coefficient – 3 reactants minus other reactants) residual chlorine decay model was proposed in the UV/Cl2 process in a water distribution network. Firstly, the single-factor experimental method was employed to assess the effects of initial residual chlorine concentration in the UV disinfection stage (C01) and pipe network decay stage (C02), UV intensity (F), inorganic nitrogen ([NO2 −]), ammonia nitrogen ([NH4 +]), and total organic carbon (TOC) on residual chlorine decay during the UV disinfection stage and pipe network decay stage. Next, the response surface method (RSM) was used to establish multivariate functions among the decay coefficients in the UV disinfection stage (k) and pipe network decay stage (K), C01, C02, temperature (T), and pH as correction coefficients. Finally, the model was calibrated using EPANET 2.0. In conclusion, (1) the optimal residual chlorine concentration and UV dose were 7.75 mg L−1 and 50.1 mJ cm−2, respectively; the pipe network disinfection by-product safety was confirmed. (2) The longest hydraulic retention time (HRT) in the pipe network was 5.12 h before the secondary chlorination. (3) The additional decay model by UV irradiation was established by subtracting the residual chlorine decay function with and without UV irradiation using the RSM's fitting results. (4) The calibration function value of the new model for two cases reached δ1win (C) = 0.18, δ1sum (C) = 0.16, δ2win (C) = 0.16 and δ2sum (C) = 0.14 in summer & autumn and spring & winter, respectively, which were less than the minimum (0.33) and standard values (0.25). (5) The residual chlorine concentration at the end of the water distribution network was less than 0.1 mg L−1 in summer & autumn, exhibiting the importance of secondary chlorination to provide a reference for this process's application in water distribution networks.
- 1 December 2022
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 9 (1) , 308-330
Improved VRC-3R− model for bulk water residual chlorine decay in the UV/Cl2 process for a water distribution network
The combination of UV irradiation and chlorine (UV/Cl2), as a new and efficient process, has been widely applied in drinking water disinfection. In this study, an improved VRC-3R− (variable rate coefficient – 3 reactants minus other reactants) residual chlorine decay model was proposed in the UV/Cl2 process in a water distribution network. Firstly, the single-factor experimental method was employed to assess the effects of initial residual chlorine concentration in the UV disinfection stage (C01) and pipe network decay stage (C02), UV intensity (F), inorganic nitrogen ([NO2 −]), ammonia nitrogen ([NH4 +]), and total organic carbon (TOC) on residual chlorine decay during the UV disinfection stage and pipe network decay stage. Next, the response surface method (RSM) was used to establish multivariate functions among the decay coefficients in the UV disinfection stage (k) and pipe network decay stage (K), C01, C02, temperature (T), and pH as correction coefficients. Finally, the model was calibrated using EPANET 2.0. In conclusion, (1) the optimal residual chlorine concentration and UV dose were 7.75 mg L−1 and 50.1 mJ cm−2, respectively; the pipe network disinfection by-product safety was confirmed. (2) The longest hydraulic retention time (HRT) in the pipe network was 5.12 h before the secondary chlorination. (3) The additional decay model by UV irradiation was established by subtracting the residual chlorine decay function with and without UV irradiation using the RSM's fitting results. (4) The calibration function value of the new model for two cases reached δ1win (C) = 0.18, δ1sum (C) = 0.16, δ2win (C) = 0.16 and δ2sum (C) = 0.14 in summer & autumn and spring & winter, respectively, which were less than the minimum (0.33) and standard values (0.25). (5) The residual chlorine concentration at the end of the water distribution network was less than 0.1 mg L−1 in summer & autumn, exhibiting the importance of secondary chlorination to provide a reference for this process's application in water distribution networks.
- 19 September 2022
- Published by HARD Publishing Company in Polish Journal of Environmental Studies
- Vol. 31 (6) , 5887-5894
Comparative Study on the Effectiveness of UV/Free Chlorine and UV/H2O2 in Degrading Trimethoprim in Water
Pharmaceuticals and personal care products (PPCPs) in drinking water have attracted increasing attention from domestic and international scholars, and Trimethoprim (TMP) is one of the common drugs in the aqueous environment. Since reactive substances such as HO• and Cl• and ClO• are generated in the UV/free chlorine oxidation system, it is considered as an emerging alternative to the UV/H2O2 process. However, since the background conditions of the water body and the oxidant concentration have an effect on the oxidation effect, a comparison of the UV/free chlorine and UV/H2O2 oxidation systems under different conditions was carried out in this paper. It was found that the removal efficiency of TMP by UV/free chlorine was 16% higher than that by UV/H2O2 at an oxidant concentration of 0.05mM, and the removal efficiency of TMP degradation by UV/free chlorine was 17% higher than that by UV/H2O2 at a HCO3 -/CO3 2- concentration of 1mM. The removal efficiency of TMP by UV/free chlorine was 17% higher than that by UV/H2O2. The UV/free chlorine oxidation system was superior to the UV/H2O2 oxidation system in degrading TMP. The main reason for this phenomenon is that the quantum yields of HClO and OCl- are higher than those of H2O2. Under the same UV intensity and concentration conditions, UV/free chlorine oxidation system can produce more free radicals in the same time, so UV/free chlorine oxidation effect is better and less costly.
- 19 September 2022
- Published by HARD Publishing Company in Polish Journal of Environmental Studies
- Vol. 31 (6) , 5887-5894
Comparative Study on the Effectiveness of UV/Free Chlorine and UV/H2O2 in Degrading Trimethoprim in Water
Pharmaceuticals and personal care products (PPCPs) in drinking water have attracted increasing attention from domestic and international scholars, and Trimethoprim (TMP) is one of the common drugs in the aqueous environment. Since reactive substances such as HO• and Cl• and ClO• are generated in the UV/free chlorine oxidation system, it is considered as an emerging alternative to the UV/H2O2 process. However, since the background conditions of the water body and the oxidant concentration have an effect on the oxidation effect, a comparison of the UV/free chlorine and UV/H2O2 oxidation systems under different conditions was carried out in this paper. It was found that the removal efficiency of TMP by UV/free chlorine was 16% higher than that by UV/H2O2 at an oxidant concentration of 0.05mM, and the removal efficiency of TMP degradation by UV/free chlorine was 17% higher than that by UV/H2O2 at a HCO3 -/CO3 2- concentration of 1mM. The removal efficiency of TMP by UV/free chlorine was 17% higher than that by UV/H2O2. The UV/free chlorine oxidation system was superior to the UV/H2O2 oxidation system in degrading TMP. The main reason for this phenomenon is that the quantum yields of HClO and OCl- are higher than those of H2O2. Under the same UV intensity and concentration conditions, UV/free chlorine oxidation system can produce more free radicals in the same time, so UV/free chlorine oxidation effect is better and less costly.
- 30 August 2022
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 127, 866-874
Screening ionic liquids for efficiently extracting perfluoroalkyl chemicals (PFACs) from wastewater
- 30 August 2022
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 127, 866-874
Screening ionic liquids for efficiently extracting perfluoroalkyl chemicals (PFACs) from wastewater
- Open Access
High Concentration Organic Wastewater with High Phosphorus Treatment by Facultative MBR
Phosphorus is one of the main factors causing water eutrophication, and the traditional phosphorus removal process causes phosphorus-rich sludge pollution. The facultative MBR process uses phosphate-reducing bacteria to convert phosphate into directly recyclable gaseous phosphine to solve this malpractice and make sewage become a new phosphorus resource. In order to investigate the phosphorus removal efficiency and the mechanism under facultative conditions, run the facultative MBR reactor for 30 days. The COD value, phosphate concentration, and phosphine yield were measured, and the changes of sludge metabolic pathway abundance and community composition in different periods were detected. According to the measurement, the maximum phosphorus removal efficiency is 43.11% and the maximum yield of phosphine is 320 μg/m3 (measured by the volume of sewage). Combined with thermodynamic analysis, the microbial mechanism of the reactor was proposed, and the possible transformation pathway of phosphorus was analyzed. At last, changes the phosphorus removal process from the ‘removal type’ to the ‘recycling type’.
Open AccessHigh Concentration Organic Wastewater with High Phosphorus Treatment by Facultative MBR
Phosphorus is one of the main factors causing water eutrophication, and the traditional phosphorus removal process causes phosphorus-rich sludge pollution. The facultative MBR process uses phosphate-reducing bacteria to convert phosphate into directly recyclable gaseous phosphine to solve this malpractice and make sewage become a new phosphorus resource. In order to investigate the phosphorus removal efficiency and the mechanism under facultative conditions, run the facultative MBR reactor for 30 days. The COD value, phosphate concentration, and phosphine yield were measured, and the changes of sludge metabolic pathway abundance and community composition in different periods were detected. According to the measurement, the maximum phosphorus removal efficiency is 43.11% and the maximum yield of phosphine is 320 μg/m3 (measured by the volume of sewage). Combined with thermodynamic analysis, the microbial mechanism of the reactor was proposed, and the possible transformation pathway of phosphorus was analyzed. At last, changes the phosphorus removal process from the ‘removal type’ to the ‘recycling type’.
- Open Access
Degradation of Trimethoprim Using the UV/Free Chlorine Process: Influencing Factors and Optimal Operating Conditions
Trimethoprim (TMP) is a pharmaceutical compound, which is commonly found in the water environment. The UV/chlorine process forms several reactive species, including hydroxyl radicals (HO•) and reactive chlorine species, to degrade contaminants. The influencing factors and the optimal operational conditions for the degradation of TMP by the UV/chlorine process were investigated. The degradation of TMP was much faster by the UV/chlorine process as compared to the UV alone or free chlorine alone process. A kinetic model was developed to simulate the degradation of TMP and determine the unknown rate constants. This study also predicted the relative contributions of each of the reactive species and photolysis using the developed kinetic model. It was found that the ClO• radical was the major reactant responsible for the degradation of TMP. Furthermore, the most important finding was the identification of the best operational conditions. The best operational conditions resulted in the lowest use of energy and electrical energy per order (EE/O), namely, (1) for the ultrapure water, the optimum intensity of the UV light and the free chlorine dosage were 2.56 Einstein/L·s and 0.064 mM, respectively, with a minimum EE/O of 0.136 kWh/m3; and (2) for the water matrix containing 3 mg/L NOM, the optimum intensity of the UV light and the free chlorine dosage were 3.45 Einstein/L s and 0.172 mM, respectively, with a minimum EE/O of 0.311 kWh/m3.
Open AccessDegradation of Trimethoprim Using the UV/Free Chlorine Process: Influencing Factors and Optimal Operating Conditions
Trimethoprim (TMP) is a pharmaceutical compound, which is commonly found in the water environment. The UV/chlorine process forms several reactive species, including hydroxyl radicals (HO•) and reactive chlorine species, to degrade contaminants. The influencing factors and the optimal operational conditions for the degradation of TMP by the UV/chlorine process were investigated. The degradation of TMP was much faster by the UV/chlorine process as compared to the UV alone or free chlorine alone process. A kinetic model was developed to simulate the degradation of TMP and determine the unknown rate constants. This study also predicted the relative contributions of each of the reactive species and photolysis using the developed kinetic model. It was found that the ClO• radical was the major reactant responsible for the degradation of TMP. Furthermore, the most important finding was the identification of the best operational conditions. The best operational conditions resulted in the lowest use of energy and electrical energy per order (EE/O), namely, (1) for the ultrapure water, the optimum intensity of the UV light and the free chlorine dosage were 2.56 Einstein/L·s and 0.064 mM, respectively, with a minimum EE/O of 0.136 kWh/m3; and (2) for the water matrix containing 3 mg/L NOM, the optimum intensity of the UV light and the free chlorine dosage were 3.45 Einstein/L s and 0.172 mM, respectively, with a minimum EE/O of 0.311 kWh/m3.