YMYanhe Ma

Yanhe Ma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yanhe Ma has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Error-Constraint Deep Learning Scheme for Electrical Impedance Tomography (EIT)

    by Qi Wang, Hanyu Zhang, Xiuyan Li, Xiaojie Duan, Jianming Wang, Ronghua Zhang, Hong Zhang, Yanhe Ma, Huaxiang Wang, Jiabin Jia

    As a new generation of noninvasiveness imaging modality, electrical impedance tomography (EIT) has broad application prospects to perform functional evaluation for human tissues and organs. Deep learning makes great breakthrough in recent years, and many different neural networks (NNs) have been applied to EIT image reconstruction for obtaining high resolution reconstruction images. However, the NN is hard to interpret, and the robustness and generalization ability of the network model cannot be guaranteed. In this study, a deep learning scheme namely error-constraint network (Ec-Net) is designed to remove the error of reconstruction images obtained by traditional reconstruction algorithm. By establishing the residual mapping between image and error, Ec-Net achieves more robust reconstruction performance and faster learning. Feature fusion module, dilated convolution block, and the structure of residual in residual are used to further improve the reconstruction accuracy for the inclusion boundary. The reconstruction results show that the proposed method can accurately reconstruct the irregular and sharp boundary of inclusions while showing good anti-noise ability for measurement noise higher than 30 dB. Even effective reconstruction can be obtained for new inclusions that have size/shape variations, which proves the generalization ability of Ec-Net model.


  • Exploring Respiratory Motion Tracking Through Electrical Impedance Tomography

    by Qi Wang, Jianming Wang, Xiuyan Li, Xiaojie Duan, Ronghua Zhang, Hong Zhang, Yanhe Ma, Huaxiang Wang, Jiabin Jia

    Motion tracking is an effective approach for the management of respiratory motion during the medical imaging process, which has always been a major concern in diagnostic imaging, interventional, and noninvasive therapy. However, the low imaging speed of traditional medical imaging techniques limits the practical application of real-time motion tracking. Electrical impedance tomography (EIT) is proved to be an effective tool for continuous monitoring of lung activity/status. However, the respiratory motion has never been studied in the medical EIT field before. In this article, preliminary research of lung movement during the respiratory process is first studied based on EIT. Multiring electrode thorax models under different respiratory statuses were constructed to obtain simulation data of EIT. A modified TV algorithm is used for the estimation of lung volume and movement based on 3-D EIT images, which improve the quality of reconstruction by approximately 30% and 20% compared with the traditional Tikhonov method and the total variation (TV) method, respectively. Both simulations and experiments were conducted to show the potential of respiratory motion tracking through 3-D EIT reconstruction.


  • Interactive Labeling System for Lung Nodules with CT Images

    by Sota Chatani, Yanhe Ma, Hong Zhang, Ying Chen, Weiwei Du

    Survival rate of lung cancer is up to 70%~90% in 5 years, if malignant lung nodules are found early. The lung nodules are malignant or benign based on size changes in a short time such as two or three months. Therefore, the volumes of lung nodules need be known. Until now, radiologists use some software to measure the volumes of lung nodules such as ImageJ, Label me and so on. These software are difficult to precisely draw the contour of a lung nodule as radiologists' thinking. Especially to the solid part of Ground-Glass Opacity nodule, the software are difficult to measure its volume. In this study, an interactive labeling system is developed for lung nodules with CT images. The proposed interactive labeling system provides three ways to draw the contour of a lung nodule: \bigcirc1. To draw the contour of a lung nodule manually. \bigcirc2. To draw the contour of a lung nodule with a semi-automatic way. \bigcirc3. To draw the contour of a lung nodule with a semiautomatic way and then modify the contour of the lung nodule manually. Moreover, radiologists can label the lung nodule based on its malignancy or benign and give some comments to the lung nodule by using the proposed labeling system. The annotation of the lung nodule by radiologists can be saved as JavaScript Object Notation (JSON) format. Therefore, there are two meanings on `label' of interactive labeling system. One is to draw the contour of a lung nodule, and the other is to give a label on malignancy or benign of a lung nodule. Practicality and effectiveness of the interactive labeling system are verified by the questionnaire.