Hee Dong Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hee Dong Lee has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Jae Chul Yoo
Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
2 shared publications - Jun-Gyu Moon
Department of Orthopedic Surgery, Korea University Guro Hospital, Seoul, Korea
2 shared publications - Woo Seung Lee
Department of Orthopedic Surgery, Veterans Health Service Medical Center, Seoul, Korea
2 shared publications - Chong Bum Chang
Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, Korea
1 shared publication - Chul-Hyun Cho
Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu, Republic of Korea
1 shared publication - Du-Han Kim
Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 29 April 2026
- Published by Wiley in Arthroscopy Techniques
- Vol. 15 (4) , e70045
Autologous Palmaris Longus Tendon Augmentation for Large to Massive Rotator Cuff Tears
This technical note describes an arthroscopic technique that utilizes the autologous palmaris longus (PL) tendon to augment large to massive rotator cuff tears when complete repair is not feasible. The PL tendon is harvested through a minimal wrist incision and delivered intramuscularly into the supraspinatus and/or infraspinatus using a shuttle relay technique. Subsequently, standard double‐row fixation is performed, incorporating the PL in a crossed suture bridge configuration. This method offers a biologically favorable and mechanically supportive alternative to dermal allografts, with minimal donor‐site morbidity. This technique may enhance graft integrity and healing potential and could be adapted using alternative tendons when PL is absent. Further studies are warranted to assess the long‐term clinical outcomes.
- 29 April 2026
- Published by Wiley in Arthroscopy Techniques
- Vol. 15 (4) , e70045
Open AccessAutologous Palmaris Longus Tendon Augmentation for Large to Massive Rotator Cuff Tears
This technical note describes an arthroscopic technique that utilizes the autologous palmaris longus (PL) tendon to augment large to massive rotator cuff tears when complete repair is not feasible. The PL tendon is harvested through a minimal wrist incision and delivered intramuscularly into the supraspinatus and/or infraspinatus using a shuttle relay technique. Subsequently, standard double‐row fixation is performed, incorporating the PL in a crossed suture bridge configuration. This method offers a biologically favorable and mechanically supportive alternative to dermal allografts, with minimal donor‐site morbidity. This technique may enhance graft integrity and healing potential and could be adapted using alternative tendons when PL is absent. Further studies are warranted to assess the long‐term clinical outcomes.
- Open Access
- 1 September 2025
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 28 (3) , 266-276
Ultrasound-assisted measurement of humeral version: a radiation-sparing alternative to whole-humerus computed tomography
Background: Humeral version is a key parameter in preoperative planning for reverse total shoulder arthroplasty (RTSA). Although computed tomography (CT) of the entire humerus is required to measure humeral version accurately, standard preoperative imaging typically includes only the scapula and proximal humerus, leading to additional radiation exposure. Ultrasound-assisted humeral torsion measurement using the bicipital groove has shown strong correlations with CT but lacks clinically applicable angle calculation methods. Methods: In this study, we evaluate whether humeral version can be accurately calculated using proximal humerus CT combined with ultrasound without additional imaging of the distal humerus. Thirty-nine patients who underwent RTSA between March 2021 and May 2022 were included. Preoperative whole-humerus CT and ultrasound-assisted version measurements were compared. Results: Intra- and inter-tester reliability of the ultrasound-assisted measurements showed intraclass correlation coefficients (ICCs) of 0.924 (95% CI, 0.857–0.960) and 0.872 (95% CI, 0.727–0.942), respectively. The mean humeral version measured by CT was 30.4°±15.1°, and 32.8°±14.5° by the ultrasound-assisted method. A strong correlation was observed between the two methods (Pearson’s r=0.915, P<0.001; concordance correlation coefficient=0.903). The ICC between the two methods was 0.905 (95% CI, 0.813–0.951). Bland-Altman analysis showed a mean difference of 2.38°, with 95% limits of agreement from –14.37° to 9.61°, indicating high agreement. Conclusions: These findings suggest that ultrasound-assisted measurement combined with proximal humerus CT is a reliable and accurate alternative to whole-humerus CT, reducing radiation exposure and cost.Level of evidence: III.
- 1 September 2025
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 28 (3) , 266-276
Open AccessUltrasound-assisted measurement of humeral version: a radiation-sparing alternative to whole-humerus computed tomography
Background: Humeral version is a key parameter in preoperative planning for reverse total shoulder arthroplasty (RTSA). Although computed tomography (CT) of the entire humerus is required to measure humeral version accurately, standard preoperative imaging typically includes only the scapula and proximal humerus, leading to additional radiation exposure. Ultrasound-assisted humeral torsion measurement using the bicipital groove has shown strong correlations with CT but lacks clinically applicable angle calculation methods. Methods: In this study, we evaluate whether humeral version can be accurately calculated using proximal humerus CT combined with ultrasound without additional imaging of the distal humerus. Thirty-nine patients who underwent RTSA between March 2021 and May 2022 were included. Preoperative whole-humerus CT and ultrasound-assisted version measurements were compared. Results: Intra- and inter-tester reliability of the ultrasound-assisted measurements showed intraclass correlation coefficients (ICCs) of 0.924 (95% CI, 0.857–0.960) and 0.872 (95% CI, 0.727–0.942), respectively. The mean humeral version measured by CT was 30.4°±15.1°, and 32.8°±14.5° by the ultrasound-assisted method. A strong correlation was observed between the two methods (Pearson’s r=0.915, P<0.001; concordance correlation coefficient=0.903). The ICC between the two methods was 0.905 (95% CI, 0.813–0.951). Bland-Altman analysis showed a mean difference of 2.38°, with 95% limits of agreement from –14.37° to 9.61°, indicating high agreement. Conclusions: These findings suggest that ultrasound-assisted measurement combined with proximal humerus CT is a reliable and accurate alternative to whole-humerus CT, reducing radiation exposure and cost.Level of evidence: III.
- Open Access
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (3) , 438-452
Surgical Outcomes of Weight-Bearing Shoulders: Arthroscopic Rotator Cuff Repair and Reverse Shoulder Arthroplasty
Kim SC, et al. Clin Orthop Surg. 2025 Jan;17:e17. https://doi.org/10.4055/cios24238
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (3) , 438-452
Open AccessSurgical Outcomes of Weight-Bearing Shoulders: Arthroscopic Rotator Cuff Repair and Reverse Shoulder Arthroplasty
Kim SC, et al. Clin Orthop Surg. 2025 Jan;17:e17. https://doi.org/10.4055/cios24238
- 24 November 2023
- Published by SAGE Publications in HAND
- Vol. 20 (2) , 203-207
Prospective Randomized Controlled Trial Comparing Absorbable and Nonabsorbable Sutures in A1 Pulley Release
Background: Both absorbable and nonabsorbable sutures are used to correct palmar incisions or lacerations. Nonabsorbable sutures have been used without complications but require removal at a follow-up appointment. Alternatively, the use of absorbable sutures has increased in popularity as postoperative suture removal is not required but is associated with local immunological and inflammatory responses. In this study, we compared the scar quality and outcomes of nonabsorbable and absorbable sutures in A1 pulley release. Methods: Patients who underwent A1 pulley release were randomized to 1 of 2 suture materials. The Patient Scar Assessment Scale, Observer Scar Assessment Scale, Visual Analogue Scale, and Disabilities of the Arm, Shoulder, and Hand scores were collected at 2, 6, and 12 weeks postoperatively. Among the 41 patients included in the study, 23 were randomized to the nonabsorbable suture group, and 18 to the absorbable suture group. Results: There were no significant differences between the two suture groups in the aforementioned assessments. Complication rates were higher in the nonabsorbable suture group, but the difference was not statistically significant. Notably, 1 case in the absorbable suture group had uncontrolled postoperative bleeding and required reoperation. Conclusion: We found no significant difference between the two materials in terms of the Patient or Observer Scar Assessment Scales, overall complication rates, symptom scores, or pain scores. Therefore, the choice using absorbable or nonabsorbable can be guided by other factors such as physician or patient preference, availability, and cost.
- 24 November 2023
- Published by SAGE Publications in HAND
- Vol. 20 (2) , 203-207
Prospective Randomized Controlled Trial Comparing Absorbable and Nonabsorbable Sutures in A1 Pulley Release
Background: Both absorbable and nonabsorbable sutures are used to correct palmar incisions or lacerations. Nonabsorbable sutures have been used without complications but require removal at a follow-up appointment. Alternatively, the use of absorbable sutures has increased in popularity as postoperative suture removal is not required but is associated with local immunological and inflammatory responses. In this study, we compared the scar quality and outcomes of nonabsorbable and absorbable sutures in A1 pulley release. Methods: Patients who underwent A1 pulley release were randomized to 1 of 2 suture materials. The Patient Scar Assessment Scale, Observer Scar Assessment Scale, Visual Analogue Scale, and Disabilities of the Arm, Shoulder, and Hand scores were collected at 2, 6, and 12 weeks postoperatively. Among the 41 patients included in the study, 23 were randomized to the nonabsorbable suture group, and 18 to the absorbable suture group. Results: There were no significant differences between the two suture groups in the aforementioned assessments. Complication rates were higher in the nonabsorbable suture group, but the difference was not statistically significant. Notably, 1 case in the absorbable suture group had uncontrolled postoperative bleeding and required reoperation. Conclusion: We found no significant difference between the two materials in terms of the Patient or Observer Scar Assessment Scales, overall complication rates, symptom scores, or pain scores. Therefore, the choice using absorbable or nonabsorbable can be guided by other factors such as physician or patient preference, availability, and cost.
- Open Access
Valgus Arthritic Knee Responds Better to Conservative Treatment than the Varus Arthritic Knee
Background and Objectives: Clinically, it is beneficial to determine the knee osteoarthritis (OA) subtype that responds well to conservative treatments. Therefore, this study aimed to determine the differences between varus and valgus arthritic knees in the response to conservative treatment. We hypothesized that valgus arthritic knees would respond better to conservative treatment than varus arthritic knees. Materials and Methods: Medical records of 834 patients who received knee OA treatment were retrospectively reviewed. Patients with Kellgren–Lawrence grades III and IV were divided into two groups according to knee alignment (varus arthritic knee, hip-knee-ankle angle [HKA] > 0° or valgus arthritic knee, HKA < 0°). The Kaplan–Meier curve with total knee arthroplasty (TKA) as an endpoint was used to compare the survival probability between varus and valgus arthritic knees at one, two, three, four, and five years after the first visit. A receiver operating characteristic (ROC) curve was used to compare the HKA thresholds for TKA between varus and valgus arthritic knees. Results: Valgus arthritic knees responded better to conservative treatment than varus arthritic knees. With TKA as an endpoint, the survival probabilities for varus and valgus arthritic knees were 24.2% and 61.4%, respectively, at the 5-year follow-up (p < 0.001). The thresholds of HKA for varus and valgus arthritic knees for TKA were 4.9° and −8.1°, respectively (varus: area under the ROC curve [AUC] = 0.704, 95% confidence interval [CI] 0.666–0.741, p < 0.001, sensitivity = 0.870, specificity = 0.524; valgus: AUC = 0.753, 95% CI 0.693–0.807, p < 0.001, sensitivity = 0.753, specificity = 0.786). Conclusions: Conservative treatment is more effective for valgus than for varus arthritic knees. This should be considered when explaining the prognosis of conservative treatment for knees with varus and valgus arthritis.
Open AccessValgus Arthritic Knee Responds Better to Conservative Treatment than the Varus Arthritic Knee
Background and Objectives: Clinically, it is beneficial to determine the knee osteoarthritis (OA) subtype that responds well to conservative treatments. Therefore, this study aimed to determine the differences between varus and valgus arthritic knees in the response to conservative treatment. We hypothesized that valgus arthritic knees would respond better to conservative treatment than varus arthritic knees. Materials and Methods: Medical records of 834 patients who received knee OA treatment were retrospectively reviewed. Patients with Kellgren–Lawrence grades III and IV were divided into two groups according to knee alignment (varus arthritic knee, hip-knee-ankle angle [HKA] > 0° or valgus arthritic knee, HKA < 0°). The Kaplan–Meier curve with total knee arthroplasty (TKA) as an endpoint was used to compare the survival probability between varus and valgus arthritic knees at one, two, three, four, and five years after the first visit. A receiver operating characteristic (ROC) curve was used to compare the HKA thresholds for TKA between varus and valgus arthritic knees. Results: Valgus arthritic knees responded better to conservative treatment than varus arthritic knees. With TKA as an endpoint, the survival probabilities for varus and valgus arthritic knees were 24.2% and 61.4%, respectively, at the 5-year follow-up (p < 0.001). The thresholds of HKA for varus and valgus arthritic knees for TKA were 4.9° and −8.1°, respectively (varus: area under the ROC curve [AUC] = 0.704, 95% confidence interval [CI] 0.666–0.741, p < 0.001, sensitivity = 0.870, specificity = 0.524; valgus: AUC = 0.753, 95% CI 0.693–0.807, p < 0.001, sensitivity = 0.753, specificity = 0.786). Conclusions: Conservative treatment is more effective for valgus than for varus arthritic knees. This should be considered when explaining the prognosis of conservative treatment for knees with varus and valgus arthritis.
- Open Access
- 31 March 2023
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 3 (3) , 376-381
Rotation of the eccentric glenosphere after reverse total shoulder arthroplasty: a case report
- 31 March 2023
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 3 (3) , 376-381
Open AccessRotation of the eccentric glenosphere after reverse total shoulder arthroplasty: a case report
- Open Access
- 1 January 2023
- Published by XMLink in Journal of the Korean Orthopaedic Association
- Vol. 58 (5) , 423-427
Huge Plexiform Schwannoma of the Ulnar Nerve
총상 신경초종은 주로 피부나 피하에 표재성으로 발생하고 총상 형태로 성장하는 것을 특징으로 하는 신경초종의 한 아형이다. 심부에 위치하거나 주요 말초신경에 발생하는 경우는 드물며, 이런 경우 악성 말초 신경초종과 구별이 어려워 절제 생검이 필요하나 아직 국내에서는 주요 말초 신경에서 시행한 수술적 치료의 장기 추시에 대한 보고가 없다. 저자들은 64세 남자 환자의 우측 척골신경에 발생한 거대 총상 신경초종을 절제 생검으로 확진하고 7년 이상 장기 추시한 경험을 보고하고자 한다. A plexiform schwannoma is a subtype of schwannoma characterized by a multinodular and plexiform pattern with a superficial occurrence, mainly under the skin or subcutaneous tissue. It is rarely located deep or occurs in the major peripheral nerves. In this case, it is difficult to distinguish a plexiform schwannoma from a malignant peripheral schwannoma, so an excisional biopsy is required. On the other hand, there are no reports on the long-term follow-up of surgical treatment performed on major peripheral nerves. The authors report the confirmation of a plexiform schwannoma on the right ulnar nerve in a 64-year-old male patient by excisional biopsy and long-term observations for seven years.
- 1 January 2023
- Published by XMLink in Journal of the Korean Orthopaedic Association
- Vol. 58 (5) , 423-427
Open AccessHuge Plexiform Schwannoma of the Ulnar Nerve
총상 신경초종은 주로 피부나 피하에 표재성으로 발생하고 총상 형태로 성장하는 것을 특징으로 하는 신경초종의 한 아형이다. 심부에 위치하거나 주요 말초신경에 발생하는 경우는 드물며, 이런 경우 악성 말초 신경초종과 구별이 어려워 절제 생검이 필요하나 아직 국내에서는 주요 말초 신경에서 시행한 수술적 치료의 장기 추시에 대한 보고가 없다. 저자들은 64세 남자 환자의 우측 척골신경에 발생한 거대 총상 신경초종을 절제 생검으로 확진하고 7년 이상 장기 추시한 경험을 보고하고자 한다. A plexiform schwannoma is a subtype of schwannoma characterized by a multinodular and plexiform pattern with a superficial occurrence, mainly under the skin or subcutaneous tissue. It is rarely located deep or occurs in the major peripheral nerves. In this case, it is difficult to distinguish a plexiform schwannoma from a malignant peripheral schwannoma, so an excisional biopsy is required. On the other hand, there are no reports on the long-term follow-up of surgical treatment performed on major peripheral nerves. The authors report the confirmation of a plexiform schwannoma on the right ulnar nerve in a 64-year-old male patient by excisional biopsy and long-term observations for seven years.
- 1 February 2022
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 31 (2) , 375-381
Radiologic evaluation and clinical effect of calcification in medial epicondylitis
- 1 February 2022
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 31 (2) , 375-381
Radiologic evaluation and clinical effect of calcification in medial epicondylitis
- Open Access
- 1 March 2020
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 23 (1) , 41-47
Comparison of Ulnar Collateral Ligament Reconstruction Techniques in the Elbow of Sports Players
Ulnar collateral ligament injuries have been increasingly common in overhead throwing athletes. Ulnar collateral ligament reconstruction is the current gold standard for managing ulnar collateral ligament insufficiency, and numerous reconstruction techniques have been described. Although good clinical outcomes have been reported regarding return to sports, there are still several technical issues including exposure, graft selection and fixation, and ulnar nerve management. This review article summarizes a variety of surgical techniques of ulnar collateral ligament reconstructions and compares clinical outcomes and biomechanics.
- 1 March 2020
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 23 (1) , 41-47
Open AccessComparison of Ulnar Collateral Ligament Reconstruction Techniques in the Elbow of Sports Players
Ulnar collateral ligament injuries have been increasingly common in overhead throwing athletes. Ulnar collateral ligament reconstruction is the current gold standard for managing ulnar collateral ligament insufficiency, and numerous reconstruction techniques have been described. Although good clinical outcomes have been reported regarding return to sports, there are still several technical issues including exposure, graft selection and fixation, and ulnar nerve management. This review article summarizes a variety of surgical techniques of ulnar collateral ligament reconstructions and compares clinical outcomes and biomechanics.
- Open Access
- 4 January 2020
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 54 (4) , 372-377
Relationship between the tilt angle of bipolar radial head prostheses and radiological radiocapitellar instability
Objective: This study aimed to radiologically assess the relationship between the tilt angle of the bipolar radial head prostheses and radiocapitellar instability. Methods: In this radiological study, 28 consecutive patients (13 females and 15 males: mean age=47 years and age range=23-77 years) who underwent cemented bipolar radial head arthroplasty (Judet CRF II) because of comminuted radial head fracture with elbow instability were retrospectively reviewed. Results: There was excellent intra- and interobserver reliability for the measurements of the tilt angle and the radiocapitellar distance. ICC for interobserver reliability of the tilt angle was 0.93, and ICC for intraobserver reliability for the 2 observers was 0.96 and 0.97, respectively. ICC for interobserver reliability of the radiocapitellar distance was 0.87, and ICC for intraobserver reliability for the 2 observers was 0.91 and 0.93, respectively. The mean tilt angle was 17.6° (range=1°-35°), and the mean radiocapitellar distance was 8 mm (range=1–17 mm). Pearson’s correlation revealed a strong significant positive correlation between the tilt angle and the radiocapitellar distance (r=0.77 and p<0.001). Conclusion: Evidence from this study has demonstrated a strong positive correlation between the tilt angle of bipolar radial head prostheses and radiocapitellar instability. The tilt angle can be used as an indicator of radiocapitellar joint instability following bipolar radial head prostheses. Level of Evidence: Level IV, Diagnostic study Cite this article as: Moon JG, Kim JH, Jung YJ, Lim MJ, Lee HD. Relationship between the tilt angle of bipolar radial head prostheses and radiological radiocapitellar instability. Acta Orthop Traumatol Turc 2020; 54(4): 372-7.
- 4 January 2020
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 54 (4) , 372-377
Open AccessRelationship between the tilt angle of bipolar radial head prostheses and radiological radiocapitellar instability
Objective: This study aimed to radiologically assess the relationship between the tilt angle of the bipolar radial head prostheses and radiocapitellar instability. Methods: In this radiological study, 28 consecutive patients (13 females and 15 males: mean age=47 years and age range=23-77 years) who underwent cemented bipolar radial head arthroplasty (Judet CRF II) because of comminuted radial head fracture with elbow instability were retrospectively reviewed. Results: There was excellent intra- and interobserver reliability for the measurements of the tilt angle and the radiocapitellar distance. ICC for interobserver reliability of the tilt angle was 0.93, and ICC for intraobserver reliability for the 2 observers was 0.96 and 0.97, respectively. ICC for interobserver reliability of the radiocapitellar distance was 0.87, and ICC for intraobserver reliability for the 2 observers was 0.91 and 0.93, respectively. The mean tilt angle was 17.6° (range=1°-35°), and the mean radiocapitellar distance was 8 mm (range=1–17 mm). Pearson’s correlation revealed a strong significant positive correlation between the tilt angle and the radiocapitellar distance (r=0.77 and p<0.001). Conclusion: Evidence from this study has demonstrated a strong positive correlation between the tilt angle of bipolar radial head prostheses and radiocapitellar instability. The tilt angle can be used as an indicator of radiocapitellar joint instability following bipolar radial head prostheses. Level of Evidence: Level IV, Diagnostic study Cite this article as: Moon JG, Kim JH, Jung YJ, Lim MJ, Lee HD. Relationship between the tilt angle of bipolar radial head prostheses and radiological radiocapitellar instability. Acta Orthop Traumatol Turc 2020; 54(4): 372-7.