Malcolm A. Lawn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Malcolm A. Lawn has a total of 120 co-authors. Here are the top co-authors by number of shared publications:
P.T.H. Fisk
8 shared publications- Michael J. Wouters
National Measurement Institute, Sydney, NSW 2070, Australia
6 shared publications C. Coles
5 shared publicationsJan Herrmann
National Measurement Institute , 36 Bradfield Road, West Lindfield, New South Wales 2070, Australia
4 shared publications- Matthew J. Sellars
Australian National University
4 shared publications R.B. Warrington
4 shared publications
Latest Publications
- Open Access
- 12 July 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (10) , 105018
Step height measurement of monoatomic silicon crystal lattice steps with a commercial atomic force microscope
Precise control of advanced materials relies on accurate dimensional metrology at the sub-nanometre scale. At this scale, the accuracy of scanning probe microscopy (SPM) has been limited by the lack of traceable transfer standard artefacts with calibration structures of suitable dimensions. With the adoption in 2019 of the silicon crystal lattice spacing as a secondary realization of the metre in the International System of Units (SI), SPM users have direct access to a realization of the SI metre at the sub-nanometre level by means of the step height of self-assembled monatomic lattice steps that can form on the surface of silicon crystals. A key challenge of successfully adopting this pathway is establishing protocols to minimize measurement errors and artefacts in routine laboratory use. In this study, step height measurements of monoatomic lattice steps in an ordinal/staircase structure on a Si(111) crystal surface have been derived from images acquired with a commercially available, research-level atomic force microscope (AFM). Measurement results derived from AFM images using three different SPM image processing and analysis software packages are compared. Significant sources of measurement uncertainty are identified, principally the contribution from the dependence on scan direction. The calibration of the AFM derived from this measurement was used to traceably measure the sub-nanometre lattice steps on a silicon carbide crystal surface to demonstrate the viability of this calibration pathway.
- 12 July 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (10) , 105018
Open AccessStep height measurement of monoatomic silicon crystal lattice steps with a commercial atomic force microscope
Precise control of advanced materials relies on accurate dimensional metrology at the sub-nanometre scale. At this scale, the accuracy of scanning probe microscopy (SPM) has been limited by the lack of traceable transfer standard artefacts with calibration structures of suitable dimensions. With the adoption in 2019 of the silicon crystal lattice spacing as a secondary realization of the metre in the International System of Units (SI), SPM users have direct access to a realization of the SI metre at the sub-nanometre level by means of the step height of self-assembled monatomic lattice steps that can form on the surface of silicon crystals. A key challenge of successfully adopting this pathway is establishing protocols to minimize measurement errors and artefacts in routine laboratory use. In this study, step height measurements of monoatomic lattice steps in an ordinal/staircase structure on a Si(111) crystal surface have been derived from images acquired with a commercially available, research-level atomic force microscope (AFM). Measurement results derived from AFM images using three different SPM image processing and analysis software packages are compared. Significant sources of measurement uncertainty are identified, principally the contribution from the dependence on scan direction. The calibration of the AFM derived from this measurement was used to traceably measure the sub-nanometre lattice steps on a silicon carbide crystal surface to demonstrate the viability of this calibration pathway.
- Open Access
- 14 February 2018
- Published by Springer Nature in Nature Communications
- Vol. 9 (1) , 1-12
Anti-fouling graphene-based membranes for effective water desalination
The inability of membranes to handle a wide spectrum of pollutants is an important unsolved problem for water treatment. Here we demonstrate water desalination via a membrane distillation process using a graphene membrane where water permeation is enabled by nanochannels of multilayer, mismatched, partially overlapping graphene grains. Graphene films derived from renewable oil exhibit significantly superior retention of water vapour flux and salt rejection rates, and a superior antifouling capability under a mixture of saline water containing contaminants such as oils and surfactants, compared to commercial distillation membranes. Moreover, real-world applicability of our membrane is demonstrated by processing sea water from Sydney Harbour over 72 h with macroscale membrane size of 4 cm2, processing ~0.5 L per day. Numerical simulations show that the channels between the mismatched grains serve as an effective water permeation route. Our research will pave the way for large-scale graphene-based antifouling membranes for diverse water treatment applications.
- 14 February 2018
- Published by Springer Nature in Nature Communications
- Vol. 9 (1) , 1-12
Open AccessAnti-fouling graphene-based membranes for effective water desalination
The inability of membranes to handle a wide spectrum of pollutants is an important unsolved problem for water treatment. Here we demonstrate water desalination via a membrane distillation process using a graphene membrane where water permeation is enabled by nanochannels of multilayer, mismatched, partially overlapping graphene grains. Graphene films derived from renewable oil exhibit significantly superior retention of water vapour flux and salt rejection rates, and a superior antifouling capability under a mixture of saline water containing contaminants such as oils and surfactants, compared to commercial distillation membranes. Moreover, real-world applicability of our membrane is demonstrated by processing sea water from Sydney Harbour over 72 h with macroscale membrane size of 4 cm2, processing ~0.5 L per day. Numerical simulations show that the channels between the mismatched grains serve as an effective water permeation route. Our research will pave the way for large-scale graphene-based antifouling membranes for diverse water treatment applications.
- 6 June 2016
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 119 (21) , 214307
Minimising the effect of nanoparticle deformation in intermittent contact amplitude modulation atomic force microscopy measurements
The results of systematic height measurements of polystyrene (PS) nanoparticles using intermittent contact amplitude modulation atomic force microscopy (IC-AM-AFM) are presented. The experimental findings demonstrate that PS nanoparticles deform during AFM imaging, as indicated by a reduction in the measured particle height. This deformation depends on the IC-AM-AFM imaging parameters, material composition, and dimensional properties of the nanoparticles. A model for nanoparticle deformation occurring during IC-AM-AFM imaging is developed as a function of the peak force which can be calculated for a particular set of experimental conditions. The undeformed nanoparticle height can be estimated from the model by extrapolation to zero peak force. A procedure is proposed to quantify and minimise nanoparticle deformation during IC-AM-AFM imaging, based on appropriate adjustments of the experimental control parameters.
- 6 June 2016
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 119 (21) , 214307
Minimising the effect of nanoparticle deformation in intermittent contact amplitude modulation atomic force microscopy measurements
The results of systematic height measurements of polystyrene (PS) nanoparticles using intermittent contact amplitude modulation atomic force microscopy (IC-AM-AFM) are presented. The experimental findings demonstrate that PS nanoparticles deform during AFM imaging, as indicated by a reduction in the measured particle height. This deformation depends on the IC-AM-AFM imaging parameters, material composition, and dimensional properties of the nanoparticles. A model for nanoparticle deformation occurring during IC-AM-AFM imaging is developed as a function of the peak force which can be calculated for a particular set of experimental conditions. The undeformed nanoparticle height can be estimated from the model by extrapolation to zero peak force. A procedure is proposed to quantify and minimise nanoparticle deformation during IC-AM-AFM imaging, based on appropriate adjustments of the experimental control parameters.
- 15 September 2013
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 15 (10) , 1919
Size characterization of airborne SiO2 nanoparticles with on-line and off-line measurement techniques: an interlaboratory comparison study
- 15 September 2013
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 15 (10) , 1919
Size characterization of airborne SiO2 nanoparticles with on-line and off-line measurement techniques: an interlaboratory comparison study
- Open Access
- 1 January 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Micro/Nanolithography, MEMS, and MOEMS
- Vol. 11 (1) , 011003-7
Metrological scanning probe microscope based on a quartz tuning fork detector
The National Measurement Institute Australia (NMIA) is establishing a capability in measurement at the nanometer scale with the aims of supporting research, development, and commercial application of nanotechnology in Australia and to assist in ensuring the safety of applications of nanotechnology for Australian consumers, workplaces, and the environment. To achieve these aims, NMIA is creating two new facilities—a scanning probe microscopy (SPM) metrology laboratory and a nanoparticle characterization laboratory.
- 1 January 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Micro/Nanolithography, MEMS, and MOEMS
- Vol. 11 (1) , 011003-7
Open AccessMetrological scanning probe microscope based on a quartz tuning fork detector
The National Measurement Institute Australia (NMIA) is establishing a capability in measurement at the nanometer scale with the aims of supporting research, development, and commercial application of nanotechnology in Australia and to assist in ensuring the safety of applications of nanotechnology for Australian consumers, workplaces, and the environment. To achieve these aims, NMIA is creating two new facilities—a scanning probe microscopy (SPM) metrology laboratory and a nanoparticle characterization laboratory.
- 1 January 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Micro/Nanolithography, MEMS, and MOEMS
- Vol. 11 (1) , 011007-1-011007-6
Particle number density gradient samples for nanoparticle metrology with atomic force microscopy
Nanoparticle metrology with atomic force microscope (AFM) aims to determine an average particle size from measurements of individual nanoparticles derived by image analysis. This constrains the statistical relevance of the measurement due to the limited number of particles which can be practically imaged and analyzed. Consequently, the number density of particles on samples prepared for particle measurement is an important parameter of sample preparation. A number density that is too low makes it difficult to obtain sufficient measurement statistics, whereas a number density that is too high can result in particle agglomeration on the substrate and limit the area of uncovered substrate that is required to obtain a reliable reference for measuring the particle height. Abstract. We present imaging and measurement results of a particle number density gradient of 16 nm gold nanoparticles deposited using a gradual immersion process. Results demonstrate how samples with particle number density gradients can facilitate identification of an area on a sample with optimal particle number density for AFM particle metrology and thereby improve measurement efficiency and reliability.
- 1 January 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Micro/Nanolithography, MEMS, and MOEMS
- Vol. 11 (1) , 011007-1-011007-6
Particle number density gradient samples for nanoparticle metrology with atomic force microscopy
Nanoparticle metrology with atomic force microscope (AFM) aims to determine an average particle size from measurements of individual nanoparticles derived by image analysis. This constrains the statistical relevance of the measurement due to the limited number of particles which can be practically imaged and analyzed. Consequently, the number density of particles on samples prepared for particle measurement is an important parameter of sample preparation. A number density that is too low makes it difficult to obtain sufficient measurement statistics, whereas a number density that is too high can result in particle agglomeration on the substrate and limit the area of uncovered substrate that is required to obtain a reliable reference for measuring the particle height. Abstract. We present imaging and measurement results of a particle number density gradient of 16 nm gold nanoparticles deposited using a gradual immersion process. Results demonstrate how samples with particle number density gradients can facilitate identification of an area on a sample with optimal particle number density for AFM particle metrology and thereby improve measurement efficiency and reliability.
- 1 March 2011
- Published by Elsevier in Advanced Powder Technology
- Vol. 22 (2) , 290-293
Systematic study of bimodal suspensions of latex nanoparticles using dynamic light scattering
- 1 March 2011
- Published by Elsevier in Advanced Powder Technology
- Vol. 22 (2) , 290-293
Systematic study of bimodal suspensions of latex nanoparticles using dynamic light scattering
- 2 June 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7729, 77290
Physico-chemical characterization of engineered metal oxide nanoparticles: the critical role of microscopy
Three different methods for extracting zinc oxide (ZnO) and titanium dioxide (TiO2) nanoparticles from commercially available sunscreen were investigated to determine the most appropriate route for producing a sample suitable for measuring the primary particle size. Direct dilution of the formulation, centrifugal methods and chemical washing were trialed in combination with ultrasonic processing and surfactant addition to generate samples that are suitable for particle size analysis. Transmission electron microscopy (TEM) and dynamic light scattering (DLS) were used to monitor the extraction and re-dispersion process. Washing with hexane, methanol and water to remove the formulation, in combination with pulsed high-powered ultrasonication and the addition of a charge-stabilizing surfactant was found to be the most efficient way of producing de-agglomerated samples. DLS measurements gave average hydrodynamic particle diameters of 87 nm for ZnO and 76 nm for TiO2, compared to equivalent spherical particle diameters of 21 ± 12 nm for ZnO (81 particles) and 19 ± 14 nm for TiO2 (81 particles) obtained from TEM analysis.
- 2 June 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7729, 77290
Physico-chemical characterization of engineered metal oxide nanoparticles: the critical role of microscopy
Three different methods for extracting zinc oxide (ZnO) and titanium dioxide (TiO2) nanoparticles from commercially available sunscreen were investigated to determine the most appropriate route for producing a sample suitable for measuring the primary particle size. Direct dilution of the formulation, centrifugal methods and chemical washing were trialed in combination with ultrasonic processing and surfactant addition to generate samples that are suitable for particle size analysis. Transmission electron microscopy (TEM) and dynamic light scattering (DLS) were used to monitor the extraction and re-dispersion process. Washing with hexane, methanol and water to remove the formulation, in combination with pulsed high-powered ultrasonication and the addition of a charge-stabilizing surfactant was found to be the most efficient way of producing de-agglomerated samples. DLS measurements gave average hydrodynamic particle diameters of 87 nm for ZnO and 76 nm for TiO2, compared to equivalent spherical particle diameters of 21 ± 12 nm for ZnO (81 particles) and 19 ± 14 nm for TiO2 (81 particles) obtained from TEM analysis.
- 2 June 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7729
Traceable nanoscale length metrology using a metrological Scanning Probe Microscope
We give an overview of the design and planned operation of the metrological Scanning Probe Microscope (mSPM) currently under development at the National Measurement Institute Australia (NMIA) and highlight the metrological principles guiding the design of the instrument. The mSPM facility is being established as part of the nanometrology program at NMIA and will provide the link in the traceability chain between dimensional measurements made at the nanometer scale and the realization of the SI meter at NMIA. The instrument will provide a measurement volume of 100 μm × 100 μm × 25 μm with a target uncertainty of 1 nm for the position measurement.
- 2 June 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7729
Traceable nanoscale length metrology using a metrological Scanning Probe Microscope
We give an overview of the design and planned operation of the metrological Scanning Probe Microscope (mSPM) currently under development at the National Measurement Institute Australia (NMIA) and highlight the metrological principles guiding the design of the instrument. The mSPM facility is being established as part of the nanometrology program at NMIA and will provide the link in the traceability chain between dimensional measurements made at the nanometer scale and the realization of the SI meter at NMIA. The instrument will provide a measurement volume of 100 μm × 100 μm × 25 μm with a target uncertainty of 1 nm for the position measurement.