Diep Nguyen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Diep Nguyen has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Bobby Carroll
Department of Physics, Syracuse University, Syracuse, New York, USA
1 shared publication- Cécile Rumeau
Service d'ORL-Chirurgie Cervico-Faciale, Université de Lorraine, CHRU Nancy, Service ORL, 54000 Nancy, France
1 shared publication Elisabeth Dubus
INSERM, CNRS, Institut de la Vision, Sorbonne Université, Paris, France
1 shared publication- Gaelle Lissorgues
ESYCOM‐ESIEE University Gustave Eiffel 77420 Champs‐sur‐Marne France
1 shared publication J. Rebois
Université de Lorraine, CHRU-Nancy, service ORL, 54000 Nancy, France
1 shared publicationJulie Dégardin
INSERM, CNRS, Institut de la Vision, Sorbonne Université, Paris, France
1 shared publication
Latest Publications
- 7 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Carbon based materials for recording and stimulating the visual pathway
Electrodes en carbone pour la stimulation et l'enregistrement de la voie visuelle: Les interfaces cerveau-machine (ICM) offrent des possibilités non seulement de réhabilitation des déficiences motrices et sensorielles, mais également de contrôle des logiciels informatiques. Elles nécessitent une profonde compréhension des activités cérébrales ainsi que de l’activation du système nerveux central par stimulation électrique. Les ICMs, et notamment les prothèses visuelles, sont fortement dépendantes de la performance et de la durabilité des microélectrodes. Les progrès en termes de matériaux de fabrication des électrodes permettront d’accroître leur résolution spatiale, avec une plus grande densité d’électrodes pour élargir la qualité du signal, comme l’acuité visuelle. Les matériaux à base de carbone suscitent de plus en plus d’intérêt en raison de leurs propriétés semi-conductrices, leur synthèse simple et leurs surfaces modulables qui les rendent polyvalents et adaptés à de nombreuses applications d’ICM.Cette thèse explore l’utilisation de graphène et de diamant dopé au bore (BDD, de l’anglais boron-doped diamond) comme microélectrodes d’interface neurale. Le graphène a été utilisé pour enregistrer les potentiels de champs locaux sur l’œil, représentés par électrorétinogrammes, ainsi que les pics d’activité sur la rétine. La stimulation électrique, quant à elle, a été appliquée aux neurones rétiniens pour développer des prothèses rétiniennes. En parallèle, la biocompatibilité du graphène avec ces interfaces neurales a été étudiée à travers la caractérisation des réactions de la rétine lors de l’implantation chronique de dispositifs recouverts de graphène dans l’œil. Enfin, l’utilisation de diamant dopé au bore a été étudiée à travers la microfabrication d’implants fonctionnels, leur caractérisation, ainsi que leur capacité à enregistrer des potentiels visuels sur la surface cérébrale. Cette étude fournit de nouveaux éléments qui confirment les nombreuses possibilités offertes par les matériaux à base de carbone. Leur usage pour des applications d’ICMs d’enregistrement et de stimulation de circuits neurologiques a été démontré, et leur biocompatibilité pour la pose d’implants de longue durée a été prouvée.
- 7 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Carbon based materials for recording and stimulating the visual pathway
Electrodes en carbone pour la stimulation et l'enregistrement de la voie visuelle: Les interfaces cerveau-machine (ICM) offrent des possibilités non seulement de réhabilitation des déficiences motrices et sensorielles, mais également de contrôle des logiciels informatiques. Elles nécessitent une profonde compréhension des activités cérébrales ainsi que de l’activation du système nerveux central par stimulation électrique. Les ICMs, et notamment les prothèses visuelles, sont fortement dépendantes de la performance et de la durabilité des microélectrodes. Les progrès en termes de matériaux de fabrication des électrodes permettront d’accroître leur résolution spatiale, avec une plus grande densité d’électrodes pour élargir la qualité du signal, comme l’acuité visuelle. Les matériaux à base de carbone suscitent de plus en plus d’intérêt en raison de leurs propriétés semi-conductrices, leur synthèse simple et leurs surfaces modulables qui les rendent polyvalents et adaptés à de nombreuses applications d’ICM.Cette thèse explore l’utilisation de graphène et de diamant dopé au bore (BDD, de l’anglais boron-doped diamond) comme microélectrodes d’interface neurale. Le graphène a été utilisé pour enregistrer les potentiels de champs locaux sur l’œil, représentés par électrorétinogrammes, ainsi que les pics d’activité sur la rétine. La stimulation électrique, quant à elle, a été appliquée aux neurones rétiniens pour développer des prothèses rétiniennes. En parallèle, la biocompatibilité du graphène avec ces interfaces neurales a été étudiée à travers la caractérisation des réactions de la rétine lors de l’implantation chronique de dispositifs recouverts de graphène dans l’œil. Enfin, l’utilisation de diamant dopé au bore a été étudiée à travers la microfabrication d’implants fonctionnels, leur caractérisation, ainsi que leur capacité à enregistrer des potentiels visuels sur la surface cérébrale. Cette étude fournit de nouveaux éléments qui confirment les nombreuses possibilités offertes par les matériaux à base de carbone. Leur usage pour des applications d’ICMs d’enregistrement et de stimulation de circuits neurologiques a été démontré, et leur biocompatibilité pour la pose d’implants de longue durée a été prouvée.
- 1 February 2021
- Published by Elsevier in Annales françaises d'Oto-rhino-laryngologie et de Pathologie Cervico-faciale
- Vol. 138 (1) , 28-34
Formation basée sur la simulation en chirurgie endoscopique endonasale : évaluation du simulateur Cyrano
- 1 February 2021
- Published by Elsevier in Annales françaises d'Oto-rhino-laryngologie et de Pathologie Cervico-faciale
- Vol. 138 (1) , 28-34
Formation basée sur la simulation en chirurgie endoscopique endonasale : évaluation du simulateur Cyrano
- Open Access
- 1 March 2020
- Published by Wolters Kluwer Health in Clinical and Translational Gastroenterology
- Vol. 11 (3) , e00119
Theranostic Gastrointestinal Endoscopy: Bringing Healing Light to the Lumen
Current conventional endoscopes have restricted the accuracy of treatment delivery and monitoring. Over the past decade, there have been major developments in nanotechnology and light triggered therapy, potentially allowing a better detection of challenging lesions and targeted treatment of malignancies in the gastrointestinal tract. Theranostics is a developing form of personalized medicine because it combines diagnosis and targeted treatment delivered in one step using advances in nanotechnology. This review describes the light-triggered therapies (including photodynamic, photothermal, and photoimmunotherapies), nanotechnological advances with nanopowder, nanostent, nanogels, and nanoparticles, enhancements brought to endoscopic ultrasound, in addition to experimental endoscopic techniques, combining both enhanced diagnoses and therapies, including a developed prototype of a “smart” multifunctional endoscope for localized colorectal cancer, near-infrared laser endoscope targeting the gastrointestinal stromal tumors, the concept of endocapsule for obscure gastrointestinal bleed, and a proof-of-concept therapeutic capsule using ultrasound-mediated targeted drug delivery. Hence, the following term has been proposed encompassing these technologies: “Theranostic gastrointestinal endoscopy.” Future efforts for integration of these technologies into clinical practice would be directed toward translational and clinical trials translating into a more personalized and interdisciplinary diagnosis and treatment, shorter procedural time, higher precision, higher cost-effectiveness, and less need for repetitive procedures.
- 1 March 2020
- Published by Wolters Kluwer Health in Clinical and Translational Gastroenterology
- Vol. 11 (3) , e00119
Open AccessTheranostic Gastrointestinal Endoscopy: Bringing Healing Light to the Lumen
Current conventional endoscopes have restricted the accuracy of treatment delivery and monitoring. Over the past decade, there have been major developments in nanotechnology and light triggered therapy, potentially allowing a better detection of challenging lesions and targeted treatment of malignancies in the gastrointestinal tract. Theranostics is a developing form of personalized medicine because it combines diagnosis and targeted treatment delivered in one step using advances in nanotechnology. This review describes the light-triggered therapies (including photodynamic, photothermal, and photoimmunotherapies), nanotechnological advances with nanopowder, nanostent, nanogels, and nanoparticles, enhancements brought to endoscopic ultrasound, in addition to experimental endoscopic techniques, combining both enhanced diagnoses and therapies, including a developed prototype of a “smart” multifunctional endoscope for localized colorectal cancer, near-infrared laser endoscope targeting the gastrointestinal stromal tumors, the concept of endocapsule for obscure gastrointestinal bleed, and a proof-of-concept therapeutic capsule using ultrasound-mediated targeted drug delivery. Hence, the following term has been proposed encompassing these technologies: “Theranostic gastrointestinal endoscopy.” Future efforts for integration of these technologies into clinical practice would be directed toward translational and clinical trials translating into a more personalized and interdisciplinary diagnosis and treatment, shorter procedural time, higher precision, higher cost-effectiveness, and less need for repetitive procedures.
- Open Access
- 27 August 2019
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 13, 885
Protuberant Electrode Structures for Subretinal Electrical Stimulation: Modeling, Fabrication and in vivo Evaluation
Many neural interfaces used for therapeutic applications are based on extracellular electrical stimulation to control cell polarization and thus functional activity. Amongst them, retinal implants have been designed to restore visual perception in blind patients affected by photoreceptor degeneration diseases, such as age-related macular degeneration (AMD) or retinitis pigmentosa (RP). While designing such a neural interface, several aspects must be taken into account, like the stimulation efficiency related to the current distribution within the tissue, the bio-interface optimization to improve resolution and tissue integration, and the material biocompatibility associated to long-term ageing. In this study, we investigate the use of original microelectrode geometries for subretinal stimulation. The proposed structures combine the use of 3D wells with protuberant mushroom shaped electrode structures in their bottom implemented on a flexible substrate that allows the in vivo implantation of the devices. These 3D microelectrode structures were first modelled using finite element analysis. Then a specific microfabrication process compatible with flexible implants was developed to create the 3D microelectrode structures. These structures were tested in-vivo in order to check the adaptation of the retinal tissue to them. Finally, preliminary in-vivo stimulation experiments were performed.
- 27 August 2019
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 13, 885
Open AccessProtuberant Electrode Structures for Subretinal Electrical Stimulation: Modeling, Fabrication and in vivo Evaluation
Many neural interfaces used for therapeutic applications are based on extracellular electrical stimulation to control cell polarization and thus functional activity. Amongst them, retinal implants have been designed to restore visual perception in blind patients affected by photoreceptor degeneration diseases, such as age-related macular degeneration (AMD) or retinitis pigmentosa (RP). While designing such a neural interface, several aspects must be taken into account, like the stimulation efficiency related to the current distribution within the tissue, the bio-interface optimization to improve resolution and tissue integration, and the material biocompatibility associated to long-term ageing. In this study, we investigate the use of original microelectrode geometries for subretinal stimulation. The proposed structures combine the use of 3D wells with protuberant mushroom shaped electrode structures in their bottom implemented on a flexible substrate that allows the in vivo implantation of the devices. These 3D microelectrode structures were first modelled using finite element analysis. Then a specific microfabrication process compatible with flexible implants was developed to create the 3D microelectrode structures. These structures were tested in-vivo in order to check the adaptation of the retinal tissue to them. Finally, preliminary in-vivo stimulation experiments were performed.