Stefano Vandi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stefano Vandi has a total of 226 co-authors. Here are the top co-authors by number of shared publications:
- Giuseppe Plazzi
Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Italy; IRCCS Istituto Delle Scienze Neurologiche di Bologna, Bologna, Italy
53 shared publications - Fabio Pizza
IRCCS Istituto delle Scienze Neurologiche di Bologna, 40139 Bologna, Italy
21 shared publications Fabio Pizza
Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy; IRCCS, Istituto delle Scienze Neurologiche di Bologna, Bologna, Italy
18 shared publications- Christian Franceschini
Department of Medicine and Surgery, University of Parma, Parma, Italy
17 shared publications - Elena Antelmi
Department of Surgery, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40133 Bologna, Italy
17 shared publications Pasquale Montagna
IRCCS, Istituto delle Scienze Neurologiche, University of Bologna, Bologna, Italy
16 shared publications
Latest Publications
- 8 April 2025
- Published by Wolters Kluwer Health in Neurology
- Vol. 104 (7) , e213473
Use of Portable 24-Hour Polysomnography as Alternative Diagnostic Tool for Narcolepsy Type 1 in Adults and Children
The diagnosis of narcolepsy type 1 (NT1) currently requires the multiple sleep latency test (MSLT), or a nocturnal sleep-onset REM period (SOREMP) combined with typical cataplexy, or alternatively the determination of CSF hypocretin-1 (CSF-hcrt-1) deficiency. We evaluated the 24-hour polysomnography (PSG) recordings in adult and pediatric patients as an alternative diagnostic tool. Patients of any age, referred to the narcolepsy center of a university hospital for suspected central disorder of hypersomnolence (CDH), were consecutively recruited between 2013 and 2022. Participants underwent 2 days (day1-night1-day2-night2) of continuous dynamic PSG followed by MSLT. When consent was given, CSF-hcrt-1 was measured. The accuracy of 24-hour PSG variables from night1 and day2 (index test) was assessed with receiver operating characteristic (ROC) curve analysis in identifying NT1 based on current criteria (applied to night2-PSG, MSLT, and CSF-hcrt1). The markers with area under the curve (AUC) ≥0.75 were then tested in adults and children, separately, and to diagnose NT1 and narcolepsy type 2 (NT2) in different scenarios. Eight hundred seven patients (30.1% pediatric, 52.4% male) were included, and 709 had CSF-hcrt-1 measured. According to the standard criteria, 322 were diagnosed with NT1 (mean age 26.7 ± 17.1 years, 40.4% pediatric, 54.0% male) and 484 with non-NT1 (mean age 32.7 ± 16.5 years, 23.3% pediatric, 51.3% male), encompassing 31 with NT2, 163 with idiopathic hypersomnia, and 281 with other diagnoses. Detecting SOREMP ≥1 during daytime resulted in AUC = 0.84 (95% CI 0.82-0.87), with 84.4% sensitivity and 84.5% specificity for NT1. Performance was superior to all nighttime-PSG measures (p < 0.001) including nighttime-SOREMP (AUC = 0.77, 95% CI 0.74-0.80; sensitivity = 62.1%, specificity = 91.7%) and did not differ from 24-hour SOREMP ≥1 (AUC = 0.85, 95% CI 0.82-0.87; sensitivity = 89.7%, specificity = 80.2%). The combination of daytime-SOREMP ≥1 with cataplexy showed AUC = 0.89 (95% CI 0.86-0.91) for NT1, superior to the combination of nighttime-SOREMP with cataplexy (AUC = 0.78, 95% CI 0.76-0.81, p < 0.001) and similar to MSLT criteria for narcolepsy (AUC = 0.90, 95% CI 0.88-0.92, p = 0.36). Performances were similar in adults and children. Daytime-SOREMP ≥1 identified NT1 and NT2 combined within all CDH with a sensitivity of 80.8% and specificity of 88.0%. The detection of daytime-SOREMP during dynamic 24-hour PSG is more accurate than nighttime-SOREMP for diagnosing narcolepsy and, combined with cataplexy, is comparable with MSLT criteria for the identification of NT1. These results offer the prospect of 24-hour PSG diagnostics for NT1 in the home setting. This study provides Class II evidence that daytime SOREMP during a 24-hour PSG accurately distinguishes NT1 in patients with a clinical history of possible cataplexy from those who do not have NT1.
- 8 April 2025
- Published by Wolters Kluwer Health in Neurology
- Vol. 104 (7) , e213473
Use of Portable 24-Hour Polysomnography as Alternative Diagnostic Tool for Narcolepsy Type 1 in Adults and Children
The diagnosis of narcolepsy type 1 (NT1) currently requires the multiple sleep latency test (MSLT), or a nocturnal sleep-onset REM period (SOREMP) combined with typical cataplexy, or alternatively the determination of CSF hypocretin-1 (CSF-hcrt-1) deficiency. We evaluated the 24-hour polysomnography (PSG) recordings in adult and pediatric patients as an alternative diagnostic tool. Patients of any age, referred to the narcolepsy center of a university hospital for suspected central disorder of hypersomnolence (CDH), were consecutively recruited between 2013 and 2022. Participants underwent 2 days (day1-night1-day2-night2) of continuous dynamic PSG followed by MSLT. When consent was given, CSF-hcrt-1 was measured. The accuracy of 24-hour PSG variables from night1 and day2 (index test) was assessed with receiver operating characteristic (ROC) curve analysis in identifying NT1 based on current criteria (applied to night2-PSG, MSLT, and CSF-hcrt1). The markers with area under the curve (AUC) ≥0.75 were then tested in adults and children, separately, and to diagnose NT1 and narcolepsy type 2 (NT2) in different scenarios. Eight hundred seven patients (30.1% pediatric, 52.4% male) were included, and 709 had CSF-hcrt-1 measured. According to the standard criteria, 322 were diagnosed with NT1 (mean age 26.7 ± 17.1 years, 40.4% pediatric, 54.0% male) and 484 with non-NT1 (mean age 32.7 ± 16.5 years, 23.3% pediatric, 51.3% male), encompassing 31 with NT2, 163 with idiopathic hypersomnia, and 281 with other diagnoses. Detecting SOREMP ≥1 during daytime resulted in AUC = 0.84 (95% CI 0.82-0.87), with 84.4% sensitivity and 84.5% specificity for NT1. Performance was superior to all nighttime-PSG measures (p < 0.001) including nighttime-SOREMP (AUC = 0.77, 95% CI 0.74-0.80; sensitivity = 62.1%, specificity = 91.7%) and did not differ from 24-hour SOREMP ≥1 (AUC = 0.85, 95% CI 0.82-0.87; sensitivity = 89.7%, specificity = 80.2%). The combination of daytime-SOREMP ≥1 with cataplexy showed AUC = 0.89 (95% CI 0.86-0.91) for NT1, superior to the combination of nighttime-SOREMP with cataplexy (AUC = 0.78, 95% CI 0.76-0.81, p < 0.001) and similar to MSLT criteria for narcolepsy (AUC = 0.90, 95% CI 0.88-0.92, p = 0.36). Performances were similar in adults and children. Daytime-SOREMP ≥1 identified NT1 and NT2 combined within all CDH with a sensitivity of 80.8% and specificity of 88.0%. The detection of daytime-SOREMP during dynamic 24-hour PSG is more accurate than nighttime-SOREMP for diagnosing narcolepsy and, combined with cataplexy, is comparable with MSLT criteria for the identification of NT1. These results offer the prospect of 24-hour PSG diagnostics for NT1 in the home setting. This study provides Class II evidence that daytime SOREMP during a 24-hour PSG accurately distinguishes NT1 in patients with a clinical history of possible cataplexy from those who do not have NT1.
- 1 January 2020
- Published by Elsevier in Sleep Medicine
- Vol. 65, 8-12
Prevalence and neurophysiological correlates of sleep disordered breathing in pediatric type 1 narcolepsy
- 1 January 2020
- Published by Elsevier in Sleep Medicine
- Vol. 65, 8-12
Prevalence and neurophysiological correlates of sleep disordered breathing in pediatric type 1 narcolepsy
- 31 October 2019
- Published by Wiley in Journal of Sleep Research
- Vol. 29 (1) , e12935
(Not so) Smart sleep tracking through the phone: Findings from a polysomnography study testing the reliability of four sleep applications
An increasing number of sleep applications are currently available and are being widely used for in‐home sleep tracking. The present study assessed four smartphone applications (Sleep Cycle‐Accelerometer, SCa; Sleep Cycle‐Microphone, SCm; Sense, Se; Smart Alarm, SA) designed for sleep−wake detection through sound and movement sensors, by comparing their performance with polysomnography. Twenty‐one healthy participants (six males, 15 females) used the four sleep applications running on iPhone (provided by the experimenter) simultaneously with portable polysomnography recording at home, while sleeping alone for two consecutive nights. Whereas all apps showed a significant correlation with polysomnography‐time in bed, only SA offered significant correlations for sleep efficacy. Furthermore, SA seemed to be quite effective in reliable detection of total sleep time and also light sleep; however, it underestimated wake and partially overestimated deep sleep. None of the apps resulted capable of detecting and scoring rapid eye movement sleep. To sum up, SC (functioning through both accelerometer and microphone) and Se did not result sufficiently reliable in sleep−wake detection compared with polysomnography. SA, the only application offering the possibility of an epoch‐by‐epoch analysis, showed higher accuracy than the other apps in comparison with polysomnography, but it still shows some limitations, particularly regarding wake and deep sleep detection. Developing scoring algorithms specific for smartphone sleep detection and adding external sensors to record other physiological parameters may overcome the present limits of sleep tracking through smart phone apps.
- 31 October 2019
- Published by Wiley in Journal of Sleep Research
- Vol. 29 (1) , e12935
(Not so) Smart sleep tracking through the phone: Findings from a polysomnography study testing the reliability of four sleep applications
An increasing number of sleep applications are currently available and are being widely used for in‐home sleep tracking. The present study assessed four smartphone applications (Sleep Cycle‐Accelerometer, SCa; Sleep Cycle‐Microphone, SCm; Sense, Se; Smart Alarm, SA) designed for sleep−wake detection through sound and movement sensors, by comparing their performance with polysomnography. Twenty‐one healthy participants (six males, 15 females) used the four sleep applications running on iPhone (provided by the experimenter) simultaneously with portable polysomnography recording at home, while sleeping alone for two consecutive nights. Whereas all apps showed a significant correlation with polysomnography‐time in bed, only SA offered significant correlations for sleep efficacy. Furthermore, SA seemed to be quite effective in reliable detection of total sleep time and also light sleep; however, it underestimated wake and partially overestimated deep sleep. None of the apps resulted capable of detecting and scoring rapid eye movement sleep. To sum up, SC (functioning through both accelerometer and microphone) and Se did not result sufficiently reliable in sleep−wake detection compared with polysomnography. SA, the only application offering the possibility of an epoch‐by‐epoch analysis, showed higher accuracy than the other apps in comparison with polysomnography, but it still shows some limitations, particularly regarding wake and deep sleep detection. Developing scoring algorithms specific for smartphone sleep detection and adding external sensors to record other physiological parameters may overcome the present limits of sleep tracking through smart phone apps.
- 10 September 2019
- Published by Wolters Kluwer Health in Neurology
- Vol. 93 (11) , E1034-E1044
Validation of Multiple Sleep Latency Test for the diagnosis of pediatric narcolepsy type 1
To validate polysomnographic markers (sleep latency and sleep-onset REM periods [SOREMPs] at the Multiple Sleep Latency Test [MSLT] and nocturnal polysomnography [PSG]) for pediatric narcolepsy type 1 (NT1) against CSF hypocretin-1 (hcrt-1) deficiency and presence of cataplexy, as no criteria are currently validated in children. Clinical, neurophysiologic, and, when available, biological data (HLA-DQB1*06:02 positivity, CSF hcrt-1 levels) of 357 consecutive children below 18 years of age evaluated for suspected narcolepsy were collected. Best MSLT cutoffs were obtained by receiver operating characteristic (ROC) curve analysis by contrasting among patients with available CSF hcrt-1 assay (n = 228) with vs without CSF hcrt-1 deficiency, and further validated in patients without available CSF hcrt-1 against cataplexy (n = 129). Patients with CSF hcrt-1 deficiency were best recognized using a mean MSLT sleep latency ≤8.2 minutes (area under the ROC curve of 0.985), or by at least 2 SOREMPs at the MSLT (area under the ROC curve of 0.975), or the combined PSG + MSLT (area under the ROC curve of 0.977). Although specificity and sensitivity of reference MSLT sleep latency ≤8 minutes and ≥2 SOREMPs (nocturnal SOREMP included) was 100% and 94.87%, the combination of MSLT sleep latency and SOREMP counts did not improve diagnostic accuracy. Age or sex also did not significantly influence these results in our pediatric population. At least 2 SOREMPs or a mean sleep latency ≤8.2 minutes at the MSLT are valid and reliable markers for pediatric NT1 diagnosis, a result contrasting with adult NT1 criteria. This study provides Class III evidence that for children with suspected narcolepsy, polysomnographic and MSLT markers accurately identify those with narcolepsy type 1.
- 10 September 2019
- Published by Wolters Kluwer Health in Neurology
- Vol. 93 (11) , E1034-E1044
Validation of Multiple Sleep Latency Test for the diagnosis of pediatric narcolepsy type 1
To validate polysomnographic markers (sleep latency and sleep-onset REM periods [SOREMPs] at the Multiple Sleep Latency Test [MSLT] and nocturnal polysomnography [PSG]) for pediatric narcolepsy type 1 (NT1) against CSF hypocretin-1 (hcrt-1) deficiency and presence of cataplexy, as no criteria are currently validated in children. Clinical, neurophysiologic, and, when available, biological data (HLA-DQB1*06:02 positivity, CSF hcrt-1 levels) of 357 consecutive children below 18 years of age evaluated for suspected narcolepsy were collected. Best MSLT cutoffs were obtained by receiver operating characteristic (ROC) curve analysis by contrasting among patients with available CSF hcrt-1 assay (n = 228) with vs without CSF hcrt-1 deficiency, and further validated in patients without available CSF hcrt-1 against cataplexy (n = 129). Patients with CSF hcrt-1 deficiency were best recognized using a mean MSLT sleep latency ≤8.2 minutes (area under the ROC curve of 0.985), or by at least 2 SOREMPs at the MSLT (area under the ROC curve of 0.975), or the combined PSG + MSLT (area under the ROC curve of 0.977). Although specificity and sensitivity of reference MSLT sleep latency ≤8 minutes and ≥2 SOREMPs (nocturnal SOREMP included) was 100% and 94.87%, the combination of MSLT sleep latency and SOREMP counts did not improve diagnostic accuracy. Age or sex also did not significantly influence these results in our pediatric population. At least 2 SOREMPs or a mean sleep latency ≤8.2 minutes at the MSLT are valid and reliable markers for pediatric NT1 diagnosis, a result contrasting with adult NT1 criteria. This study provides Class III evidence that for children with suspected narcolepsy, polysomnographic and MSLT markers accurately identify those with narcolepsy type 1.
- Open Access
- 6 August 2019
- Published by Wiley in Annals of Clinical and Translational Neurology
- Vol. 6 (9) , 1872-1876
Biomarkers for REM sleep behavior disorder in idiopathic and narcoleptic patients
To search for discriminating biomarkers, 30 patients with idiopathic rapid‐eye‐movements sleep behavior disorder (iRBD) were compared with 17 patients with RBD within narcolepsy type 1. Both groups underwent extensive examinations, including skin biopsy searching for phosphorylated α‐synuclein deposits and whole‐night video‐polysomnography. Skin biopsy was positive for phosphorylated α‐synuclein deposits in 86.7% of iRBD patients and in none of narcoleptic patients. The analysis of video‐polysomnographic motor events showed differences in their occurrence throughout the night in the two groups. iRBD and RBD due to narcolepsy do have different clinical and pathological findings, confirming a different pathophysiology.
- 6 August 2019
- Published by Wiley in Annals of Clinical and Translational Neurology
- Vol. 6 (9) , 1872-1876
Open AccessBiomarkers for REM sleep behavior disorder in idiopathic and narcoleptic patients
To search for discriminating biomarkers, 30 patients with idiopathic rapid‐eye‐movements sleep behavior disorder (iRBD) were compared with 17 patients with RBD within narcolepsy type 1. Both groups underwent extensive examinations, including skin biopsy searching for phosphorylated α‐synuclein deposits and whole‐night video‐polysomnography. Skin biopsy was positive for phosphorylated α‐synuclein deposits in 86.7% of iRBD patients and in none of narcoleptic patients. The analysis of video‐polysomnographic motor events showed differences in their occurrence throughout the night in the two groups. iRBD and RBD due to narcolepsy do have different clinical and pathological findings, confirming a different pathophysiology.
- 29 July 2019
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 42 (12)
Cardiovascular autonomic dysfunction, altered sleep architecture, and muscle overactivity during nocturnal sleep in pediatric patients with narcolepsy type 1
Study Objectives: Arterial blood pressure (ABP) decreases during sleep compared with wakefulness and this change is blunted in mouse models of and adult patients with narcolepsy type 1 (NT1). We tested whether: (1) pediatric patients with NT1 have similar cardiovascular autonomic abnormalities during nocturnal sleep; and (2) these abnormalities can be linked to hypocretin-1 cerebrospinal fluid concentration (CSF HCRT-1), sleep architecture, or muscle activity.Methods: Laboratory polysomnographic studies were performed in 27 consecutive drug-naïve NT1 children or adolescents and in 19 matched controls. Nocturnal sleep architecture and submentalis (SM), tibialis anterior (TA), and hand extensor (HE) electromyographic (EMG) activity were analyzed. Cardiovascular autonomic function was assessed through the analysis of pulse transit time (PTT) and heart period (HP).Results: PTT showed reduced lengthening during total sleep and REM sleep compared with nocturnal wakefulness in NT1 patients than in controls, whereas HP did not. NT1 patients had altered sleep architecture, higher SM EMG during REM sleep, and higher TA and HE EMG during N1–N3 and REM sleep when compared with controls. PTT alterations found in NT1 patients were more severe in subjects with lower CSF HRCT-1, but did not cluster or correlate with sleep architecture alterations or muscle overactivity during sleep.Conclusion: Our results suggest that pediatric NT1 patients close to disease onset have impaired capability to modulate ABP as a function of nocturnal wake–sleep transitions, possibly as a direct consequence of hypocretin neuron loss. The relevance of this finding for cardiovascular risk later in life remains to be determined.
- 29 July 2019
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 42 (12)
Cardiovascular autonomic dysfunction, altered sleep architecture, and muscle overactivity during nocturnal sleep in pediatric patients with narcolepsy type 1
Study Objectives: Arterial blood pressure (ABP) decreases during sleep compared with wakefulness and this change is blunted in mouse models of and adult patients with narcolepsy type 1 (NT1). We tested whether: (1) pediatric patients with NT1 have similar cardiovascular autonomic abnormalities during nocturnal sleep; and (2) these abnormalities can be linked to hypocretin-1 cerebrospinal fluid concentration (CSF HCRT-1), sleep architecture, or muscle activity.Methods: Laboratory polysomnographic studies were performed in 27 consecutive drug-naïve NT1 children or adolescents and in 19 matched controls. Nocturnal sleep architecture and submentalis (SM), tibialis anterior (TA), and hand extensor (HE) electromyographic (EMG) activity were analyzed. Cardiovascular autonomic function was assessed through the analysis of pulse transit time (PTT) and heart period (HP).Results: PTT showed reduced lengthening during total sleep and REM sleep compared with nocturnal wakefulness in NT1 patients than in controls, whereas HP did not. NT1 patients had altered sleep architecture, higher SM EMG during REM sleep, and higher TA and HE EMG during N1–N3 and REM sleep when compared with controls. PTT alterations found in NT1 patients were more severe in subjects with lower CSF HRCT-1, but did not cluster or correlate with sleep architecture alterations or muscle overactivity during sleep.Conclusion: Our results suggest that pediatric NT1 patients close to disease onset have impaired capability to modulate ABP as a function of nocturnal wake–sleep transitions, possibly as a direct consequence of hypocretin neuron loss. The relevance of this finding for cardiovascular risk later in life remains to be determined.
- 1 June 2019
- Published by Springer Nature in Sleep and Breathing
- Vol. 24 (2) , 605-614
Excessive daytime sleepiness in narcolepsy and central nervous system hypersomnias
Excessive daytime sleepiness (EDS) is the core complaint of central nervous system (CNS) hypersomnias. In this mini-review, we summarized EDS features in CNS hypersomnias to provide a guide for differential diagnosis purposes.
- 1 June 2019
- Published by Springer Nature in Sleep and Breathing
- Vol. 24 (2) , 605-614
Excessive daytime sleepiness in narcolepsy and central nervous system hypersomnias
Excessive daytime sleepiness (EDS) is the core complaint of central nervous system (CNS) hypersomnias. In this mini-review, we summarized EDS features in CNS hypersomnias to provide a guide for differential diagnosis purposes.
- Open Access
- 1 February 2019
- Published by Wiley in Annals of Clinical and Translational Neurology
- Vol. 6 (3) , 445-455
Cortical activation during sleep predicts dream experience in narcolepsy
Objective: Narcolepsy type 1 widely affects the architecture of sleep with frequent fast transition to REM sleep at both nighttime and daytime sleep onset. The occurrence of repeated sleep onset REM periods over the Multiple Sleep Latency Test offers a unique opportunity to identify EEG patterns predictive of successful dream recall after short periods composed of only REM or NREM sleep. It also permits to disentangle state‐ from trait‐like differences in dream recall, by using a within‐subjects design.Methods: A consecutive series of 115 first‐diagnosed drug‐free adult narcolepsy‐type 1 patients underwent Multiple Sleep Latency Tests and were asked after each nap opportunity if they had or had not a dream experience. Scalp EEG power and a specific index of cortical activation (delta/beta power ratio), obtained from naps of 43 patients with both presence and absence of dream recall in the same sleep stage, were compared separately for REM and NREM sleep.Results: Successful dream recall was associated with an increased EEG desynchronization in both REM and NREM over partially overlapping cortical areas. Compared to unsuccessful recall, it showed (1) lower delta power over centro‐parietal areas during both stages, (2) higher beta power in the same cortical areas during NREM, and (3) lower values in the delta/beta ratio during NREM in most scalp locations.Interpretation: A more activated electrophysiological milieu in both REM and NREM sleep promotes dream recall, strengthening the notion that the parietal areas are crucial not only in generating dream experience, as shown in brain‐damaged patients, but also in the memory processing leading to recall.
- 1 February 2019
- Published by Wiley in Annals of Clinical and Translational Neurology
- Vol. 6 (3) , 445-455
Open AccessCortical activation during sleep predicts dream experience in narcolepsy
Objective: Narcolepsy type 1 widely affects the architecture of sleep with frequent fast transition to REM sleep at both nighttime and daytime sleep onset. The occurrence of repeated sleep onset REM periods over the Multiple Sleep Latency Test offers a unique opportunity to identify EEG patterns predictive of successful dream recall after short periods composed of only REM or NREM sleep. It also permits to disentangle state‐ from trait‐like differences in dream recall, by using a within‐subjects design.Methods: A consecutive series of 115 first‐diagnosed drug‐free adult narcolepsy‐type 1 patients underwent Multiple Sleep Latency Tests and were asked after each nap opportunity if they had or had not a dream experience. Scalp EEG power and a specific index of cortical activation (delta/beta power ratio), obtained from naps of 43 patients with both presence and absence of dream recall in the same sleep stage, were compared separately for REM and NREM sleep.Results: Successful dream recall was associated with an increased EEG desynchronization in both REM and NREM over partially overlapping cortical areas. Compared to unsuccessful recall, it showed (1) lower delta power over centro‐parietal areas during both stages, (2) higher beta power in the same cortical areas during NREM, and (3) lower values in the delta/beta ratio during NREM in most scalp locations.Interpretation: A more activated electrophysiological milieu in both REM and NREM sleep promotes dream recall, strengthening the notion that the parietal areas are crucial not only in generating dream experience, as shown in brain‐damaged patients, but also in the memory processing leading to recall.
- 1 January 2019
- Published by Elsevier in Sleep Medicine
- Vol. 53, 197-204
A standardized test to document cataplexy
- 1 January 2019
- Published by Elsevier in Sleep Medicine
- Vol. 53, 197-204
A standardized test to document cataplexy
- Top Cited PapersOpen Access
- 6 December 2018
- Published by Springer Nature in Nature Communications
- Vol. 9 (1) , 1-15
Neural network analysis of sleep stages enables efficient diagnosis of narcolepsy
Analysis of sleep for the diagnosis of sleep disorders such as Type-1 Narcolepsy (T1N) currently requires visual inspection of polysomnography records by trained scoring technicians. Here, we used neural networks in approximately 3,000 normal and abnormal sleep recordings to automate sleep stage scoring, producing a hypnodensity graph—a probability distribution conveying more information than classical hypnograms. Accuracy of sleep stage scoring was validated in 70 subjects assessed by six scorers. The best model performed better than any individual scorer (87% versus consensus). It also reliably scores sleep down to 5 s instead of 30 s scoring epochs. A T1N marker based on unusual sleep stage overlaps achieved a specificity of 96% and a sensitivity of 91%, validated in independent datasets. Addition of HLA-DQB1*06:02 typing increased specificity to 99%. Our method can reduce time spent in sleep clinics and automates T1N diagnosis. It also opens the possibility of diagnosing T1N using home sleep studies.
- 6 December 2018
- Published by Springer Nature in Nature Communications
- Vol. 9 (1) , 1-15
Top Cited PapersOpen AccessNeural network analysis of sleep stages enables efficient diagnosis of narcolepsy
Analysis of sleep for the diagnosis of sleep disorders such as Type-1 Narcolepsy (T1N) currently requires visual inspection of polysomnography records by trained scoring technicians. Here, we used neural networks in approximately 3,000 normal and abnormal sleep recordings to automate sleep stage scoring, producing a hypnodensity graph—a probability distribution conveying more information than classical hypnograms. Accuracy of sleep stage scoring was validated in 70 subjects assessed by six scorers. The best model performed better than any individual scorer (87% versus consensus). It also reliably scores sleep down to 5 s instead of 30 s scoring epochs. A T1N marker based on unusual sleep stage overlaps achieved a specificity of 96% and a sensitivity of 91%, validated in independent datasets. Addition of HLA-DQB1*06:02 typing increased specificity to 99%. Our method can reduce time spent in sleep clinics and automates T1N diagnosis. It also opens the possibility of diagnosing T1N using home sleep studies.