Cyril Herrier
Research Subjects
Cyril Herrier has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
Thierry Livache
8 shared publications- Thierry Livache
Université Grenoble Alpes, Commissariat à l’Énergie Atomique (CEA), Centre National de la Recherche Scientifique (CNRS), Grenoble Institut d’Ingénierie et de Management (INP), Institut de Recherche Interdisciplinaire de Grenoble (IRIG), Systèmes Moléculaires et nanoMatériaux pour l’Énergie et la Santé (SyMMES), F-38000 Grenoble, France
5 shared publications - Arnaud Buhot
Grenoble Alpes University, CEA, CNRS, IRIG-SyMMES, 17 Rue des Martyrs, 38000 Grenoble, France
4 shared publications - Bruno Fabre
Univ Rennes CNRS ISCR (Institut des Sciences Chimiques de Rennes) – UMR 6226 Rennes France
4 shared publications - Yanxia Hou
Grenoble Alpes University, CEA, CNRS, Grenoble INP, IRIG-SyMMES, 17 Rue des Martyrs, Grenoble, 38000, France
4 shared publications - Dodzi Zigah
Univ. Bordeaux, ISM, UMR 5255, F-33400 Talence, France
2 shared publications
Latest Publications
- Open Access
- 28 July 2026
- Published by Elsevier in SSRN Electronic Journal
Eight-channel parallel CMUT array with onboard humidity correction and peptide-modulated VOC affinity for electronic nose applications
Capacitive micromachined ultrasonic transducers (CMUTs) are promising gravimetric platforms for volatile organic compound (VOC) detection in clinical environments, yet their deployment is critically hindered by humidity interference: in wound headspace or exhaled breath, rapid relative humidity fluctuations — rather than elevated humidity per se — generate frequency shifts that consistently overshadow ppb–ppm analyte signals. We present a multichannel CMUT sensor array combining peptide surface functionalization with an affinity-based linear humidity correction model. Four bare sensors (S1–S4) and four peptide-functionalized sensors (S5–S8) are operated simultaneously, enabling per-channel decoupling of water-induced and analyte-induced frequency contributions without architectural modification to the chip. Both external and internal humidity referencing strategies are validated against two model analytes — phenylethyl alcohol (PEA) and cis-3-hexenol (Cis3). Internal correction, which uses the bare CMUT sensors themselves as in-situ humidity probes, consistently reduces inter-replicate variability in the extracted VOC affinity coefficients α relative to external referencing, yielding mean values of -3.44 ± 0.52 kHz/ppm for PEA and -0.026 ± 0.003 kHz/ppm for Cis3 across functionalized sensors. The ratio of inter-cluster to intra-cluster distance in PCA space — a metric of analyte class separability — increases from 1.4 to 3.0 upon humidity correction of the full sensor array, confirming that compensation directly improves analyte discriminability. These results establish peptide functionalization coupled with on-chip humidity referencing as a scalable pathway toward miniaturized electronic nose platforms deployable in real-world humid environments.
- 28 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEight-channel parallel CMUT array with onboard humidity correction and peptide-modulated VOC affinity for electronic nose applications
Capacitive micromachined ultrasonic transducers (CMUTs) are promising gravimetric platforms for volatile organic compound (VOC) detection in clinical environments, yet their deployment is critically hindered by humidity interference: in wound headspace or exhaled breath, rapid relative humidity fluctuations — rather than elevated humidity per se — generate frequency shifts that consistently overshadow ppb–ppm analyte signals. We present a multichannel CMUT sensor array combining peptide surface functionalization with an affinity-based linear humidity correction model. Four bare sensors (S1–S4) and four peptide-functionalized sensors (S5–S8) are operated simultaneously, enabling per-channel decoupling of water-induced and analyte-induced frequency contributions without architectural modification to the chip. Both external and internal humidity referencing strategies are validated against two model analytes — phenylethyl alcohol (PEA) and cis-3-hexenol (Cis3). Internal correction, which uses the bare CMUT sensors themselves as in-situ humidity probes, consistently reduces inter-replicate variability in the extracted VOC affinity coefficients α relative to external referencing, yielding mean values of -3.44 ± 0.52 kHz/ppm for PEA and -0.026 ± 0.003 kHz/ppm for Cis3 across functionalized sensors. The ratio of inter-cluster to intra-cluster distance in PCA space — a metric of analyte class separability — increases from 1.4 to 3.0 upon humidity correction of the full sensor array, confirming that compensation directly improves analyte discriminability. These results establish peptide functionalization coupled with on-chip humidity referencing as a scalable pathway toward miniaturized electronic nose platforms deployable in real-world humid environments.
- Open Access
Proof-of-Concept Study on Supercritical Fluid Chromatography Hyphenated with a Fast Optoelectronic Nose for Online Monitoring of Odorant Molecules
In this study, we explored the use of surface plasmon resonance (SPR) and Mach–Zehnder interferometry for detecting compounds in complex mixtures separated by supercritical fluid chromatography. Each molecule was individually injected and analyzed by supercritical fluid chromatography (SFC) in a 10% alcoholic solution. The fingerprints obtained via the sensors were then compared to the fingerprints of the same molecules present in a lemon essential oil (EO) at the same dilution. The results show a remarkable correlation between UV sensors and electronic noses (e-nose), enabling compound detection. The obtained signals are normalized and presented as radar charts to visualize the specific olfactory signatures of each molecule. The olfactory profiles of monoterpenes C10H16 such as α-pinene and limonene show notable differences, as do the C10H16O isomers (citral, geranial, and neral). Mach–Zehnder interferometry also allows for the discrimination of limonene enantiomers, a challenging task for current chromatography techniques. Statistical analysis confirms the ability of these technologies to differentiate compounds, including isomers. Even if UV detection is more sensitive than SPR, e-noses (SPR and Mach–Zehnder interferometers) offer the unique advantage of providing specific signatures for each compound, facilitating real-time identification. This study demonstrates the effectiveness of combining e-noses with SFC for rapid, non-destructive detection of volatile compounds. This concept can be extended to other terpenoids and volatile compounds, and hybridization with gas chromatography could be a future potential development.
Open AccessProof-of-Concept Study on Supercritical Fluid Chromatography Hyphenated with a Fast Optoelectronic Nose for Online Monitoring of Odorant Molecules
In this study, we explored the use of surface plasmon resonance (SPR) and Mach–Zehnder interferometry for detecting compounds in complex mixtures separated by supercritical fluid chromatography. Each molecule was individually injected and analyzed by supercritical fluid chromatography (SFC) in a 10% alcoholic solution. The fingerprints obtained via the sensors were then compared to the fingerprints of the same molecules present in a lemon essential oil (EO) at the same dilution. The results show a remarkable correlation between UV sensors and electronic noses (e-nose), enabling compound detection. The obtained signals are normalized and presented as radar charts to visualize the specific olfactory signatures of each molecule. The olfactory profiles of monoterpenes C10H16 such as α-pinene and limonene show notable differences, as do the C10H16O isomers (citral, geranial, and neral). Mach–Zehnder interferometry also allows for the discrimination of limonene enantiomers, a challenging task for current chromatography techniques. Statistical analysis confirms the ability of these technologies to differentiate compounds, including isomers. Even if UV detection is more sensitive than SPR, e-noses (SPR and Mach–Zehnder interferometers) offer the unique advantage of providing specific signatures for each compound, facilitating real-time identification. This study demonstrates the effectiveness of combining e-noses with SFC for rapid, non-destructive detection of volatile compounds. This concept can be extended to other terpenoids and volatile compounds, and hybridization with gas chromatography could be a future potential development.
- Open Access
Correction of 2π Phase Jumps for Silicon Photonic Sensors Based on Mach Zehnder Interferometers with Application in Gas and Biosensing
Silicon photonic sensors based on Mach Zehnder Interferometers (MZIs) have applications spanning from biological and olfactory sensors to temperature and ultrasound sensors. Although a coherent detection scheme can solve the issues of sensitivity fading and ambiguity in phase direction, the measured phase remains 2 periodic. This implies that the acquisition frequency should ensure a phase shift lower than between each measurement point to prevent 2 phase jumps. Here, we describe and experimentally characterize two methods based on reference MZIs with lower sensitivities to alleviate this drawback. These solutions improve the measurement robustness and allow the lowering of the acquisition frequency. The first method is based on the phase derivative sign comparison. When a discrepancy is detected, the reference MZI is used to choose whether 2 should be added or removed from the nominal MZI. It can correct 2 phase jumps regardless of the sensitivity ratio, so that a single reference MZI can be used to correct multiple nominal MZIs. This first method relaxes the acquisition frequency requirement by a factor of almost two. However, it cannot correct phase jumps of 4, 6 or higher between two measurement points. The second method is based on the comparison between the measured phase from the nominal MZI and the phase expected from the reference MZI. It can correct multiple 2 phase jumps but requires at least one reference MZI per biofunctionalization. It will also constrain the corrected phase to lie in a limited interval of [, +] around the expected value, and might fail to correct phase shifts above a few tens of radians depending on the disparity of the nominal sensors responses. Nonetheless, for phase shift lower than typically 20 radians, this method allows the lowering of the acquisition frequency almost arbitrarily.Open AccessCorrection of 2π Phase Jumps for Silicon Photonic Sensors Based on Mach Zehnder Interferometers with Application in Gas and Biosensing
Silicon photonic sensors based on Mach Zehnder Interferometers (MZIs) have applications spanning from biological and olfactory sensors to temperature and ultrasound sensors. Although a coherent detection scheme can solve the issues of sensitivity fading and ambiguity in phase direction, the measured phase remains 2 periodic. This implies that the acquisition frequency should ensure a phase shift lower than between each measurement point to prevent 2 phase jumps. Here, we describe and experimentally characterize two methods based on reference MZIs with lower sensitivities to alleviate this drawback. These solutions improve the measurement robustness and allow the lowering of the acquisition frequency. The first method is based on the phase derivative sign comparison. When a discrepancy is detected, the reference MZI is used to choose whether 2 should be added or removed from the nominal MZI. It can correct 2 phase jumps regardless of the sensitivity ratio, so that a single reference MZI can be used to correct multiple nominal MZIs. This first method relaxes the acquisition frequency requirement by a factor of almost two. However, it cannot correct phase jumps of 4, 6 or higher between two measurement points. The second method is based on the comparison between the measured phase from the nominal MZI and the phase expected from the reference MZI. It can correct multiple 2 phase jumps but requires at least one reference MZI per biofunctionalization. It will also constrain the corrected phase to lie in a limited interval of [, +] around the expected value, and might fail to correct phase shifts above a few tens of radians depending on the disparity of the nominal sensors responses. Nonetheless, for phase shift lower than typically 20 radians, this method allows the lowering of the acquisition frequency almost arbitrarily. - 7 April 2022
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 225, 104549
A calibrant-free drift compensation method for gas sensor arrays
- 7 April 2022
- Published by Elsevier in Chemometrics and Intelligent Laboratory Systems
- Vol. 225, 104549
A calibrant-free drift compensation method for gas sensor arrays
- 1 January 2022
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 350
Using a bio-inspired surface resonance plasmon electronic nose for fundamental research on human olfaction
- 1 January 2022
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 350
Using a bio-inspired surface resonance plasmon electronic nose for fundamental research on human olfaction
- 1 October 2020
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 320, 128342
An experimental investigation comparing a surface plasmon resonance imaging-based artificial nose with natural olfaction
- 1 October 2020
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 320, 128342
An experimental investigation comparing a surface plasmon resonance imaging-based artificial nose with natural olfaction
- Open Access
- 31 July 2020
- Published by MDPI AG in Chemosensors
- Vol. 8 (3) , 60
Opto-Electronic Nose Coupled to a Silicon Micro Pre-Concentrator Device for Selective Sensing of Flavored Waters
Headspace analysis of highly humid samples remains a challenge for artificial olfaction. Based on surface plasmon resonance imaging and bio-based sensors, the NeOse Pro olfactive analyzer yields multivariate data and enhances the statistical discrimination capacity of odor patterns. However, the presence of a high background signal, such as water vapor from aqueous samples, may deteriorate its discriminant ability. Recently, miniaturized pre-concentrators packed with hydrophobic adsorbent have been developed to improve the detection limit of gas analysis methods and to enhance their selectivity by reducing the water’s background signal. This work presents, for the first time, the coupling of a miniaturized silicon micro pre-concentration unit (µPC) to a bio-based opto-electronic nose (NeOse Pro). The results showed that the coupling of a silicon µPC with the NeOse Pro led to an improvement in the detection limit of n-nonane by at least a factor of 125. Additionally, principal component analysis (PCA) of eight different flavored waters showed an enhanced discrimination ability of the coupled set-up in highly humid conditions.
- 31 July 2020
- Published by MDPI AG in Chemosensors
- Vol. 8 (3) , 60
Open AccessOpto-Electronic Nose Coupled to a Silicon Micro Pre-Concentrator Device for Selective Sensing of Flavored Waters
Headspace analysis of highly humid samples remains a challenge for artificial olfaction. Based on surface plasmon resonance imaging and bio-based sensors, the NeOse Pro olfactive analyzer yields multivariate data and enhances the statistical discrimination capacity of odor patterns. However, the presence of a high background signal, such as water vapor from aqueous samples, may deteriorate its discriminant ability. Recently, miniaturized pre-concentrators packed with hydrophobic adsorbent have been developed to improve the detection limit of gas analysis methods and to enhance their selectivity by reducing the water’s background signal. This work presents, for the first time, the coupling of a miniaturized silicon micro pre-concentration unit (µPC) to a bio-based opto-electronic nose (NeOse Pro). The results showed that the coupling of a silicon µPC with the NeOse Pro led to an improvement in the detection limit of n-nonane by at least a factor of 125. Additionally, principal component analysis (PCA) of eight different flavored waters showed an enhanced discrimination ability of the coupled set-up in highly humid conditions.
- 1 July 2020
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 159, 112183
Reliable chiral recognition with an optoelectronic nose
- 1 July 2020
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 159, 112183
Reliable chiral recognition with an optoelectronic nose
- 22 January 2020
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 124 (6) , 3756-3767
Optical Index Prism Sensitivity of Surface Plasmon Resonance Imaging in Gas Phase: Experiment versus Theory
- 22 January 2020
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 124 (6) , 3756-3767
Optical Index Prism Sensitivity of Surface Plasmon Resonance Imaging in Gas Phase: Experiment versus Theory