Xianchang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xianchang Li has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
Shiding Zhang
Henan Joint International Research Laboratory of Nanocomposite Sensing Materials Anyang Institute of Technology Anyang China
7 shared publicationsHaijun Yang
The Affiliated Anyang Tumor Hospital Henan University of Science and Technology Anyang China
4 shared publicationsQianqian Gao
Henan Joint International Research Laboratory of Nanocomposite Sensing Materials, Anyang Institute of Technology, Anyang 455000, Henan Province, China
4 shared publicationsChaojun Cui
Henan Joint International Research Laboratory of Nanocomposite Sensing Materials, Anyang Institute of Technology, Anyang, China
3 shared publications- Fuyou Zhou
Anyang Tumor Hospital, The Affiliated Anyang Tumor Hospital of Henan University of Science and Technology, Henan key medical laboratory of precise prevention and treatment of esophageal cancer, Anyang 455001, Henan Province, China
3 shared publications Chengbo Li
Henan Joint International Research Laboratory of Nanocomposite Sensing Materials, Anyang Institute of Technology, Anyang, China
2 shared publications
Latest Publications
- 9 October 2026
- Published by Wiley in Journal of Biophotonics
- Vol. 19 (10) , e70373
Machine Learning‐Enhanced Fiber‐Optic Raman Spectroscopy for In Situ Oral Cancer Classification
A portable Raman spectroscopy system was developed for in vivo diagnosis of oral squamous cell carcinoma (OSCC) in clinical settings. 46 patients with histopathologically confirmed OSCC were involved. The preprocessed dataset was used to train four supervised machine learning classifiers, support vector machine (SVM), k‐nearest neighbors (KNN), ensemble algorithms (EA), and linear discriminant analysis (LDA), under a stratified ten‐fold cross‐validation scheme. Comparative evaluation demonstrated that SVM achieved perfect classification accuracy (100%), outperforming LDA (96.6%), EA (90.7%), and KNN (83.3%). SVM performance was evaluated against retained PC count to assess robustness and generalizability. The area under the receiver operating characteristic curve (AUC‐ROC) remained above 80% with two PCs and increased to 96% when eight PCs were retained. These findings underscore the clinical translational potential of machine learning driven Raman spectroscopy, with high discriminative power and generalizability for oral cancer.
- 9 October 2026
- Published by Wiley in Journal of Biophotonics
- Vol. 19 (10) , e70373
Machine Learning‐Enhanced Fiber‐Optic Raman Spectroscopy for In Situ Oral Cancer Classification
A portable Raman spectroscopy system was developed for in vivo diagnosis of oral squamous cell carcinoma (OSCC) in clinical settings. 46 patients with histopathologically confirmed OSCC were involved. The preprocessed dataset was used to train four supervised machine learning classifiers, support vector machine (SVM), k‐nearest neighbors (KNN), ensemble algorithms (EA), and linear discriminant analysis (LDA), under a stratified ten‐fold cross‐validation scheme. Comparative evaluation demonstrated that SVM achieved perfect classification accuracy (100%), outperforming LDA (96.6%), EA (90.7%), and KNN (83.3%). SVM performance was evaluated against retained PC count to assess robustness and generalizability. The area under the receiver operating characteristic curve (AUC‐ROC) remained above 80% with two PCs and increased to 96% when eight PCs were retained. These findings underscore the clinical translational potential of machine learning driven Raman spectroscopy, with high discriminative power and generalizability for oral cancer.
- Open Access
Awareness-Guided Self-Supervised Visual Odometry via Fusion of Pseudo-Depth and Residual-Flow Cues
Self-supervised monocular visual odometry (VO) commonly relies on photometric consistency and rigid-scene assumptions to learn camera motion, making pose estimation vulnerable to unreliable cross-frame observations caused by limited geometric observability and independently moving objects. To address this problem, we propose an awareness-guided self-supervised visual odometry framework that emphasizes reliable cross-frame observations for pose learning. Pseudo-depth is exploited to characterize geometric observability and identify regions that are unreliable for cross-frame reconstruction, while residual flow is employed to capture motion inconsistency introduced by independently moving objects. The resulting observable static regions are incorporated into pose estimation at both the input and loss levels, enabling unreliable observations to be suppressed before feature extraction and during optimization. Qualitative experiments on KITTI and Cityscapes verify the effectiveness of pseudo-depth and residual flow in extracting geometric observability and dynamic-motion information across different driving scenes. Quantitative experiments on the KITTI Odometry dataset show that the proposed method achieves average relative translation and rotation errors of 6.04% and 2.42°/100 m, together with an ATE of 0.88 m and an ARE of 0.20°, demonstrating improved ego-motion and trajectory estimation.
Open AccessAwareness-Guided Self-Supervised Visual Odometry via Fusion of Pseudo-Depth and Residual-Flow Cues
Self-supervised monocular visual odometry (VO) commonly relies on photometric consistency and rigid-scene assumptions to learn camera motion, making pose estimation vulnerable to unreliable cross-frame observations caused by limited geometric observability and independently moving objects. To address this problem, we propose an awareness-guided self-supervised visual odometry framework that emphasizes reliable cross-frame observations for pose learning. Pseudo-depth is exploited to characterize geometric observability and identify regions that are unreliable for cross-frame reconstruction, while residual flow is employed to capture motion inconsistency introduced by independently moving objects. The resulting observable static regions are incorporated into pose estimation at both the input and loss levels, enabling unreliable observations to be suppressed before feature extraction and during optimization. Qualitative experiments on KITTI and Cityscapes verify the effectiveness of pseudo-depth and residual flow in extracting geometric observability and dynamic-motion information across different driving scenes. Quantitative experiments on the KITTI Odometry dataset show that the proposed method achieves average relative translation and rotation errors of 6.04% and 2.42°/100 m, together with an ATE of 0.88 m and an ARE of 0.20°, demonstrating improved ego-motion and trajectory estimation.
- Open Access
- 4 August 2026
- Published by Elsevier in Chemico-Biological Interactions
- Vol. 438, 112277
Colorectal cancer organoid co-culture systems and their applications in drug screening
- 4 August 2026
- Published by Elsevier in Chemico-Biological Interactions
- Vol. 438, 112277
Open AccessColorectal cancer organoid co-culture systems and their applications in drug screening
- Open Access
- 1 August 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (8)
Anisotropy in elastic modulus of fault materials: Insights from the discrete element method
The potential for earthquakes triggered by modulus softening in fault cores has been extensively documented, with a particular emphasis on calculating and characterizing the modulus within fault gouges. Traditionally, the modulus is treated as an average parameter of the entire assembly, and its anisotropic nature is often overlooked. This study derives and verifies formulae to calculate the anisotropy of the elastic modulus of fault material in ellipsoidal assemblies of different shapes using the discrete element method. It defines the anisotropy of the elastic modulus on an irreducible tensor basis in the normal direction of contact forces between particles. The findings indicate that shape-induced anisotropy significantly affects the elastic modulus. Given the consistency between the elastic modulus and wave velocity, the process of elastic wave propagation is simulated. The wave velocity is estimated using the time-of-flight method, which validates the accuracy of the anisotropic decomposition. The relationship between velocity and shape, ascertained by the time-of-flight method, is consistent with that derived from the anisotropic decomposition of the elastic modulus. In contrast, the global average modulus, which disregards anisotropy, fails to acknowledge this relationship. This study highlights the critical importance of considering modulus anisotropy in fault gouges. It evidences the efficacy and universality of this approach, which can be readily applied to other physical properties with orientation dependencies, such as polarization, magnetization, principal axes of stress or strain, and crystallographic axes, among others.
- 1 August 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (8)
Open AccessAnisotropy in elastic modulus of fault materials: Insights from the discrete element method
The potential for earthquakes triggered by modulus softening in fault cores has been extensively documented, with a particular emphasis on calculating and characterizing the modulus within fault gouges. Traditionally, the modulus is treated as an average parameter of the entire assembly, and its anisotropic nature is often overlooked. This study derives and verifies formulae to calculate the anisotropy of the elastic modulus of fault material in ellipsoidal assemblies of different shapes using the discrete element method. It defines the anisotropy of the elastic modulus on an irreducible tensor basis in the normal direction of contact forces between particles. The findings indicate that shape-induced anisotropy significantly affects the elastic modulus. Given the consistency between the elastic modulus and wave velocity, the process of elastic wave propagation is simulated. The wave velocity is estimated using the time-of-flight method, which validates the accuracy of the anisotropic decomposition. The relationship between velocity and shape, ascertained by the time-of-flight method, is consistent with that derived from the anisotropic decomposition of the elastic modulus. In contrast, the global average modulus, which disregards anisotropy, fails to acknowledge this relationship. This study highlights the critical importance of considering modulus anisotropy in fault gouges. It evidences the efficacy and universality of this approach, which can be readily applied to other physical properties with orientation dependencies, such as polarization, magnetization, principal axes of stress or strain, and crystallographic axes, among others.
- 12 September 2024
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 325, 125127
Detection of Verticillium infection in cotton leaves using ATR-FTIR spectroscopy coupled with machine learning algorithms
- 12 September 2024
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 325, 125127
Detection of Verticillium infection in cotton leaves using ATR-FTIR spectroscopy coupled with machine learning algorithms
- 5 December 2022
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 289, 122210
A one-dimensional convolutional neural network based deep learning for high accuracy classification of transformation stages in esophageal squamous cell carcinoma tissue using micro-FTIR
- 5 December 2022
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 289, 122210
A one-dimensional convolutional neural network based deep learning for high accuracy classification of transformation stages in esophageal squamous cell carcinoma tissue using micro-FTIR
- 28 October 2022
- Published by Elsevier in Photodiagnosis and Photodynamic Therapy
- Vol. 40, 103177
Rapid and sensitive detection of esophageal cancer by FTIR spectroscopy of serum and plasma
- 28 October 2022
- Published by Elsevier in Photodiagnosis and Photodynamic Therapy
- Vol. 40, 103177
Rapid and sensitive detection of esophageal cancer by FTIR spectroscopy of serum and plasma
- Open Access
- 31 August 2022
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2022, 1-15
A Study of Contact Detection between Noncircular Particles in Discrete Element Method
One of the key points of modeling noncircular particles in the discrete element method is the contact detection of particles. In this study, a general contact detection algorithm of two-dimensional particles with analytic shape functions is provided. The contact detection of particles with strictly convex shape function, such as ellipses and superellipses, is solved by Newton–Raphson method, and a grid method is provided to deal with heart-shaped particles. The grid method can be generalized into a particle system, in which the shape function is not convex. The accuracy and stability of the algorithm are verified by a series of tests. For the collision of a pair of ellipses with an aspect ratio of = = 1000, the efficiency is not worse than the Newton–Raphson method. For random packing under gravity, no residual kinetic energy is observed, and the force that acts on the bottom is equal to the gravity, that is, the system reaches a mechanical equilibrium state. After equilibrium, the process of hopper discharge is also simulated. The present method is suitable for arbitrarily shaped particles with analytic shape functions in two-dimensional cases. In addition to superellipses, the method can also be applied to other particle systems as long as the shape functions are given.
- 31 August 2022
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2022, 1-15
Open AccessA Study of Contact Detection between Noncircular Particles in Discrete Element Method
One of the key points of modeling noncircular particles in the discrete element method is the contact detection of particles. In this study, a general contact detection algorithm of two-dimensional particles with analytic shape functions is provided. The contact detection of particles with strictly convex shape function, such as ellipses and superellipses, is solved by Newton–Raphson method, and a grid method is provided to deal with heart-shaped particles. The grid method can be generalized into a particle system, in which the shape function is not convex. The accuracy and stability of the algorithm are verified by a series of tests. For the collision of a pair of ellipses with an aspect ratio of = = 1000, the efficiency is not worse than the Newton–Raphson method. For random packing under gravity, no residual kinetic energy is observed, and the force that acts on the bottom is equal to the gravity, that is, the system reaches a mechanical equilibrium state. After equilibrium, the process of hopper discharge is also simulated. The present method is suitable for arbitrarily shaped particles with analytic shape functions in two-dimensional cases. In addition to superellipses, the method can also be applied to other particle systems as long as the shape functions are given.
- 21 July 2021
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 413 (23) , 5725-5731
Simple and fast colorimetric and electrochemical methods for the ultrasensitive detection of glucose
Developing ultrasensitive and user-friendly methods for the detection glucose has attracted more and more attention. By virtue of high selectivity and sensitivity, enzyme-based glucose sensor plays a key role in point-of-care sensing technology for detecting glucose concentration. In this study, Amplex Red (AR), as both indicator and mediator, was investigated to detect glucose in presence of glucose oxidase (GOx) enzymes using colorimetric and electrochemical methods. Without using any advanced techniques and sophisticated nanomaterials, 1 μM glucose can be easily detected through simply detecting the solution color with a visual colorimetric method. On the other hand, the electrochemical method can provide much higher sensitivity for the detection of glucose, which achieves a linear range spanning from 20 nM to 3.56 μM with a limit of 7.3 nM (signal-to-noise ratio SNR = 3). It is also found that the presence of other sugars such as fructose, lactose, and maltose have very limited interference effects on the detection of glucose. More importantly, a bare GC electrode was used in all these electrochemical measurements without any electrode surface modification, guaranteeing a simple and fast operation. The analytical platforms for the detection of glucose presented here not only provide simple, fast, and ultrasensitive methods, but also have the potential to advance the sensing technology in the application of other health diagnostic research areas. Graphical abstract Amplex Red (AR) was reported as both an indicator and mediator for the sensitive and specific determination of glucose using the colorimetric and electrochemical methods. The detection limit was 1 μM glucose by the visual colorimetric methods. A bare glassy carbon electrode without any functional modification was employed for the detection as low as 20 nM glucose with LOD of 7.3 nm (SNR = 3) in the electrochemical method.
- 21 July 2021
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 413 (23) , 5725-5731
Simple and fast colorimetric and electrochemical methods for the ultrasensitive detection of glucose
Developing ultrasensitive and user-friendly methods for the detection glucose has attracted more and more attention. By virtue of high selectivity and sensitivity, enzyme-based glucose sensor plays a key role in point-of-care sensing technology for detecting glucose concentration. In this study, Amplex Red (AR), as both indicator and mediator, was investigated to detect glucose in presence of glucose oxidase (GOx) enzymes using colorimetric and electrochemical methods. Without using any advanced techniques and sophisticated nanomaterials, 1 μM glucose can be easily detected through simply detecting the solution color with a visual colorimetric method. On the other hand, the electrochemical method can provide much higher sensitivity for the detection of glucose, which achieves a linear range spanning from 20 nM to 3.56 μM with a limit of 7.3 nM (signal-to-noise ratio SNR = 3). It is also found that the presence of other sugars such as fructose, lactose, and maltose have very limited interference effects on the detection of glucose. More importantly, a bare GC electrode was used in all these electrochemical measurements without any electrode surface modification, guaranteeing a simple and fast operation. The analytical platforms for the detection of glucose presented here not only provide simple, fast, and ultrasensitive methods, but also have the potential to advance the sensing technology in the application of other health diagnostic research areas. Graphical abstract Amplex Red (AR) was reported as both an indicator and mediator for the sensitive and specific determination of glucose using the colorimetric and electrochemical methods. The detection limit was 1 μM glucose by the visual colorimetric methods. A bare glassy carbon electrode without any functional modification was employed for the detection as low as 20 nM glucose with LOD of 7.3 nm (SNR = 3) in the electrochemical method.
- 5 June 2021
- Published by Wiley in Journal of Biophotonics
- Vol. 14 (9) , e202100010
Blood plasma resonance Raman spectroscopy combined with multivariate analysis for esophageal cancer detection
We herein report a novel, reliable and inexpensive method for detecting esophageal cancer using blood plasma resonance Raman spectroscopy combined with multivariate analysis methods. The blood plasma samples were divided into late stage cancer group (n = 164), early stage cancer group (n = 35) and normal group (n = 135) based on clinical pathological diagnosis. Using a specially designed quartz capillary tube as sample holder, we obtained higher quality resonance Raman spectra of blood plasma than existing method. The study demonstrated that the carotenoids levels in blood plasma were reduced in esophageal cancer patients. The area under the receiver operating characteristic curve (and 95% confidence interval) calculated by wavenumber selection and principal component analysis combined with linear discriminant analysis (PC‐LDA) algorithm were 0.894 (0.858‐0.929), 0.901 (0.841‐0.960) and 0.871 (0.799‐0.942) for differentiating late cancer from normal, late cancer from early cancer, and early cancer from normal respectively. The contribution from the two carotenoids wavenumber regions of 1155 and 1515 cm−1 were more than 84.2%. The results show that the plasma carotenoids could be a potential biomarker for screening esophageal cancer using resonance Raman spectroscopy combined with wavenumber selection and PC‐LDA algorithms.
- 5 June 2021
- Published by Wiley in Journal of Biophotonics
- Vol. 14 (9) , e202100010
Blood plasma resonance Raman spectroscopy combined with multivariate analysis for esophageal cancer detection
We herein report a novel, reliable and inexpensive method for detecting esophageal cancer using blood plasma resonance Raman spectroscopy combined with multivariate analysis methods. The blood plasma samples were divided into late stage cancer group (n = 164), early stage cancer group (n = 35) and normal group (n = 135) based on clinical pathological diagnosis. Using a specially designed quartz capillary tube as sample holder, we obtained higher quality resonance Raman spectra of blood plasma than existing method. The study demonstrated that the carotenoids levels in blood plasma were reduced in esophageal cancer patients. The area under the receiver operating characteristic curve (and 95% confidence interval) calculated by wavenumber selection and principal component analysis combined with linear discriminant analysis (PC‐LDA) algorithm were 0.894 (0.858‐0.929), 0.901 (0.841‐0.960) and 0.871 (0.799‐0.942) for differentiating late cancer from normal, late cancer from early cancer, and early cancer from normal respectively. The contribution from the two carotenoids wavenumber regions of 1155 and 1515 cm−1 were more than 84.2%. The results show that the plasma carotenoids could be a potential biomarker for screening esophageal cancer using resonance Raman spectroscopy combined with wavenumber selection and PC‐LDA algorithms.