Sandipan Dhar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sandipan Dhar has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Madhuchhanda Mitra
Department of Applied Physics, University of Calcutta, Kolkata, India
5 shared publications - Sourav Kumar Mukhopadhyay
Department of Applied Physics, University of Calcutta 92, A.P.C. Road, Kolkata 700009, India
3 shared publications - Deboleena Sadhukhan
Department of Applied Physics, University of Calcutta, Kolkata, India
2 shared publications M. M. Baig
Department of Electrical and Electronics Engineering, Auckland University of Technology Auckland, 1142, New Zealand
2 shared publicationsS. Mitra
Netaji Nagar Day College, University of Calcutta 170/436, N.S.C. Bose Road, Kolkata 700092, India
2 shared publications- Saurabh Pal
University of Calcutta
2 shared publications
Latest Publications
- Open Access
- 9 May 2024
- Published by Qeios Ltd
Review of: "Efficacy of the Electrocardiographic P-Wave Indices (PWIs) in Predicting Atrial High-Rate Episodes (AHREs) With Cardiac Implantable Electronic Devices (CIEDs)"
Since it is a review paper, it should be more informative and technical. We all related to this field are well aware of the significance of P-wave characteristics as a diagnostic marker. Therefore, the information should be more compact and to the po...
- 9 May 2024
- Published by Qeios Ltd
Open AccessReview of: "Efficacy of the Electrocardiographic P-Wave Indices (PWIs) in Predicting Atrial High-Rate Episodes (AHREs) With Cardiac Implantable Electronic Devices (CIEDs)"
Since it is a review paper, it should be more informative and technical. We all related to this field are well aware of the significance of P-wave characteristics as a diagnostic marker. Therefore, the information should be more compact and to the po...
- 14 January 2024
- Published by Springer Nature in Journal of Ambient Intelligence and Humanized Computing
- Vol. 15 (4) , 2169-2180
Efficient detection of cardiac abnormalities via a simplified score-based analysis of the ECG signal
- 14 January 2024
- Published by Springer Nature in Journal of Ambient Intelligence and Humanized Computing
- Vol. 15 (4) , 2169-2180
Efficient detection of cardiac abnormalities via a simplified score-based analysis of the ECG signal
- 27 January 2022
- Published by Springer Nature in Sādhanā
- Vol. 47 (1) , 1-11
Effortless detection of premature ventricular contraction using computerized analysis of photoplethysmography signal
- 27 January 2022
- Published by Springer Nature in Sādhanā
- Vol. 47 (1) , 1-11
Effortless detection of premature ventricular contraction using computerized analysis of photoplethysmography signal
- 28 January 2020
- Published by Elsevier in Journal of Crystal Growth
- Vol. 535, 125532
Growth of dilute quaternary alloy InPNBi and its′ characterization
- 28 January 2020
- Published by Elsevier in Journal of Crystal Growth
- Vol. 535, 125532
Growth of dilute quaternary alloy InPNBi and its′ characterization
- 22 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (6) , 2881-2890
Automated Screening of Myocardial Infarction Based on Statistical Analysis of Photoplethysmographic Data
Integration of automated cardiac analysis techniques with the personal healthcare devices can aid in the timely diagnosis of myocardial infarction (MI) to reduce the risk of mortality. The use of electrocardiogram (ECG) along with advanced signal processing tools limits the application of the available techniques for such portable devices having limited processing ability. Here we propose a novel MI screening technique based on photoplethysmographic (PPG) data, which is the most widely monitored signal in everyday health monitoring. Two simple statistical features ideally reflecting the MI induced variability in the PPG data are identified. To combat with the noise sensitivity of the PPG acquisition process the same statistical parameters are employed for eliminating the noise corrupted data segments. Classification of MI data is then performed using simple threshold based binary classification approach. The technique is evaluated with PPG records collected from 62 hospitalized MI patients and 65 healthy subjects. The robustness of the algorithm is cross validated with both MI and non-MI records collected from the MIMIC II database. The algorithm achieves an average detection accuracy of 96.25sensitivity and specificity of 96.36% and 96.15%, respectively. The promising results establish the utility of PPG as an alternate MI diagnosing tool. Apart from using the less obtrusive PPG signal, the proposed technique relies on simple feature extraction and classification tools; thus, making it a promising alternative to the ECG based techniques for implementation on the personal healthcare devices.
- 22 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (6) , 2881-2890
Automated Screening of Myocardial Infarction Based on Statistical Analysis of Photoplethysmographic Data
Integration of automated cardiac analysis techniques with the personal healthcare devices can aid in the timely diagnosis of myocardial infarction (MI) to reduce the risk of mortality. The use of electrocardiogram (ECG) along with advanced signal processing tools limits the application of the available techniques for such portable devices having limited processing ability. Here we propose a novel MI screening technique based on photoplethysmographic (PPG) data, which is the most widely monitored signal in everyday health monitoring. Two simple statistical features ideally reflecting the MI induced variability in the PPG data are identified. To combat with the noise sensitivity of the PPG acquisition process the same statistical parameters are employed for eliminating the noise corrupted data segments. Classification of MI data is then performed using simple threshold based binary classification approach. The technique is evaluated with PPG records collected from 62 hospitalized MI patients and 65 healthy subjects. The robustness of the algorithm is cross validated with both MI and non-MI records collected from the MIMIC II database. The algorithm achieves an average detection accuracy of 96.25sensitivity and specificity of 96.36% and 96.15%, respectively. The promising results establish the utility of PPG as an alternate MI diagnosing tool. Apart from using the less obtrusive PPG signal, the proposed technique relies on simple feature extraction and classification tools; thus, making it a promising alternative to the ECG based techniques for implementation on the personal healthcare devices.
- 1 February 2019
- Published by Springer Nature
- p. 505-509
Study of Thermally Annealed GaSbBi Quantum Dots Grown on GaAs by Liquid Phase Epitaxy
- 1 February 2019
- Published by Springer Nature
- p. 505-509
Study of Thermally Annealed GaSbBi Quantum Dots Grown on GaAs by Liquid Phase Epitaxy
- 1 February 2018
- Published by Elsevier in Measurement
- Vol. 116, 533-542
An efficient data compression and encryption technique for PPG signal
- 1 February 2018
- Published by Elsevier in Measurement
- Vol. 116, 533-542
An efficient data compression and encryption technique for PPG signal
- 1 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 232-236
Noise reduction and ECG feature extraction using interpolation and Hilbert transform
An effective and reliable noise reduction and Electrocardiogram (ECG) feature extraction algorithm is proposed in this paper. Contaminated ECG samples are de-noised using a Butterworth lowpass and IIR notch filter. First derivative using Lagrange Five Point Interpolation formula and Hilbert Transform of those ECG samples are computed. Sample having maximum amplitude is found out from the transformed data and those samples having amplitude within a lead wise specific threshold of that maximum are selected. The point where those selected samples undergo slope alteration in the original time domain ECG signal is marked as R peak. After successful identification of R peak points, base line modulation correction is implemented using an empirically determined formula. Q and S points are identified by finding minimum amplitude on the either side of the most recently detected R peak. QRS onset and offset points are also detected. After detecting all these characteristic points, Heart Rate, R, Q and S peak heights and QRS duration are measured. Errors in these extracted ECG features are also calculated. The algorithm offers a good level of Sensitivity (99.84%), Positive Predictivity (99.84%) and Detection Accuracy (99.84%) of R peak. Different types of ECG data of all the 12 leads taken from PTB diagnostic ECG database (PTB-DB) is used for testing the performance of the proposed module.
- 1 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 232-236
Noise reduction and ECG feature extraction using interpolation and Hilbert transform
An effective and reliable noise reduction and Electrocardiogram (ECG) feature extraction algorithm is proposed in this paper. Contaminated ECG samples are de-noised using a Butterworth lowpass and IIR notch filter. First derivative using Lagrange Five Point Interpolation formula and Hilbert Transform of those ECG samples are computed. Sample having maximum amplitude is found out from the transformed data and those samples having amplitude within a lead wise specific threshold of that maximum are selected. The point where those selected samples undergo slope alteration in the original time domain ECG signal is marked as R peak. After successful identification of R peak points, base line modulation correction is implemented using an empirically determined formula. Q and S points are identified by finding minimum amplitude on the either side of the most recently detected R peak. QRS onset and offset points are also detected. After detecting all these characteristic points, Heart Rate, R, Q and S peak heights and QRS duration are measured. Errors in these extracted ECG features are also calculated. The algorithm offers a good level of Sensitivity (99.84%), Positive Predictivity (99.84%) and Detection Accuracy (99.84%) of R peak. Different types of ECG data of all the 12 leads taken from PTB diagnostic ECG database (PTB-DB) is used for testing the performance of the proposed module.
- 1 January 2014
- Published by Springer Nature
- p. 783-785
Transport of Nitrogen Atoms During the Liquid Phase Epitaxial Growth of InGaAsN
- 1 January 2014
- Published by Springer Nature
- p. 783-785
Transport of Nitrogen Atoms During the Liquid Phase Epitaxial Growth of InGaAsN
- 1 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 210-213
Noise reduction and lossless ECG encoding
This paper proposes an efficient technique to eliminate high frequency and power line interference noise from digitized Electrocardiogram (ECG) signal and compression of that enhanced signal in a lossless manner. ECG data of different diseases taken from PTB diagnostic ECG database (PTB-DB) is used to test the performance of the module. At first, contaminated ECG signal is passed through a Butterworth lowpass filter to remove high frequency noises whose order is chosen on experimental basis. To remove power line interference noise, an IIR notch filter is designed properly. Enhanced signal is compressed using a strict lossless technique. The proposed module can reduce noise as well as ECG data file size efficiently.
- 1 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 210-213
Noise reduction and lossless ECG encoding
This paper proposes an efficient technique to eliminate high frequency and power line interference noise from digitized Electrocardiogram (ECG) signal and compression of that enhanced signal in a lossless manner. ECG data of different diseases taken from PTB diagnostic ECG database (PTB-DB) is used to test the performance of the module. At first, contaminated ECG signal is passed through a Butterworth lowpass filter to remove high frequency noises whose order is chosen on experimental basis. To remove power line interference noise, an IIR notch filter is designed properly. Enhanced signal is compressed using a strict lossless technique. The proposed module can reduce noise as well as ECG data file size efficiently.