VNValentina Novati

Valentina Novati

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Valentina Novati has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Characterization of aluminum microwave SQUID multiplexers for CE ν NS detection

    by J Amidei, A Armatol, C Augier, L Bailly-Salins, G Baulieu, L Bergé, J Billard, J Blé, G Brenot, G Bres, et al.

    We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ( μ MUX) prototype for transition-edge sensor readout in the Ricochet experiment. The device consists of aluminum coplanar-waveguide resonators and RF superconducting quantum interference devices with Dolan-style Al/AlO x /Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1–1.5 μ Φ 0 / Hz . With flux-ramp modulation, low-frequency 1 / f noise is suppressed, and the flux sensitivity is around 3–4 μ Φ 0 / Hz , corresponding to a current sensitivity of 24–33 pA / Hz at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier between the μ MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3–0.6 μ Φ 0 / Hz and an effective system noise temperature below 1K. These results establish aluminum μ MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

  • Performance of a SuperCDMS HVeV detector with Sub-eV energy resolution and single charge-sensitivity

    by Kyle Kennard, Aditi Pradeep, Mason Buchanan, Hope Fu, Aviv Simchony, Qihua Wang, Emanuele Michielin, Taylor Aralis, Elspeth Cudmore, Priscilla Cushman, et al.

  • Sensitivity enhancement of the CUORE experiment via the development of Cherenkov hybrid TeO₂ bolometers

    by Valentina Novati

    Amélioration de la sensibilité de l'expérience CUORE par le développement de bolomètres de TeO₂ hybrides à “lumière Cherenkov: CUORE est la plus grande expérience qui recherche la double désintégration bêta sans neutrino avec des bolomètres de TeO₂. La découverte de cette transition nucléaire aurait des conséquences décisives sur la scène actuelle de la physique. Les questions suivantes trouveraient une réponse : pourquoi la matière est-elle dominante dans l’Univers? Quelle est la masse du neutrino? Le neutrino est il un particule de Majorana ou de Dirac? Ce travail présente deux approches différentes pour l’amélioration de la sensibilité de CUORE en vue de sa prochaine phase : CUPID. Dans la première partie de ce travail, une étude du modèle thermique pour les bolomètres équipés avec des NTDs est présentée dans le but de mieux comprendre la réponse des détecteurs de CUORE. Les bolomètres sont des détecteurs extraordinaires utilisés pour un grand nombre d’applications en raison de leurs performances remarquables, mais leur modélisation et leur simulation sont loin d’être complètement comprises. Deux mesures ont été effectuées pour évaluer expérimentalement deux paramètres du modèle thermique : la conductance de la colle et celle entre les électrons et les phonons. Dans la deuxième partie de ce travail, la possibilité de détecter la faible lumière Cherenkov émise par le TeO₂ est étudiée à fin de rejeter des événements alpha, le fond principal de l’expérience CUORE. Le défi consiste dans la détection d’un signal de lumière de 100 eV à moyen d’un détecteur équipé avec un NTD qui a normalement un bruit de l’ordre de 100 eV. Cette question peut être résolue grâce à l’effet Neganov-Trofimov-Luke (NTL) qui a permis de baisser le seuil du détecteur de lumière et d'améliorer son rapport signal-sur-bruit. Cet effet exploite la présence d’un champ électrique pour amplifier les signaux thermiques des bolomètres. Le rejet complet du fond alpha a été prouvé avec un photo-bolomètre amélioré par l’effet NTL et couplé à un bolomètre de TeO₂ comme ceux utilisés par CUORE. Une solution convaincante pour le rejet de fond alpha a été démontrée en vue de l’expérience CUPID.

  • Open Access

    Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV detector

    by M. F. Albakry, I. Alkhatib, D. Alonso-González, J. Anczarski, T. Aralis, T. Aramaki, I. Ataee Langroudy, C. Bathurst, R. Bhattacharyya, A. J. Biffl, et al.

    We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of 6.1 g · days of exposure produces exclusion limits for dark matter-electron scattering cross sections for masses as low as 1 MeV / c 2 , as well as on the photon-dark photon mixing parameter and the coupling constant between axionlike particles and electrons for particles with masses > 1.2 eV / c 2 probed via absorption processes.


  • Open Access

    Performance of a SuperCDMS HVeV Detector with Sub-eV Energy Resolution and Single Charge-sensitivity

    by Kyle Kennard, Aditi Pradeep, Mason Buchanan, Hope Fu, Aviv Simchony, Qihua Wang, Emanuele Michielin, Taylor Aralis, Elspeth Cudmore, Priscilla Cushman, et al.

    We present a detailed characterization of a new generation of athermal-phonon single-charge sensitive Si HVeV detectors, the best of which achieved 612 meV $\pm$ 4 meV baseline resolution. Our sub-eV energy resolution enables precise measurements of single-photon events and reveal consistent energy losses of 0.81 eV $\pm$ 0.03 eV per charge excitation across two facilities. We demonstrate that the noise for these detectors is well described using a standard Transition Edge Sensor noise model. We also place upper bounds on the nominal phonon collection efficiency of 45\%, establishing these detectors as the most efficient athermal phonon detectors to date, limited only by intrinsic limitations of quasiparticle generation.

  • Open Access

    Characterization of mini-CryoCube detectors from the RICOCHET experiment commissioning at the Institut Laue-Langevin

    by A. Armatol, C. Augier, L. Bailly-Salins, G. Baulieu, L. Bergé, J. Billard, J. Blé, G. Bres, J-.L. Bret, A. Broniatowski, et al.

    The experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-g germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 14 ( 3 ) events / ( kg day keV ) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% confidence level limit on the nuclear recoil background of < 9 events / ( kg day keV ) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events / ( kg day keV ) . The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Collaboration with upgraded detectors.


  • Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps

    by M. F. Albakry, I. Alkhatib, D. Alonso-González, D. W. P. Amaral, J. Anczarski, T. Aralis, T. Aramaki, I. Ataee Langroudy, C. Bathurst, R. Bhattacharyya, et al.


  • Improved modeling of detector response effects in phonon-based crystal detectors used for dark matter searches

    by M. J. Wilson, A. Zaytsev, B. von Krosigk, I. Alkhatib, M. Buchanan, R. Chen, M. D. Diamond, E. Figueroa-Feliciano, S. A. S. Harms, Z. Hong, et al.

    Various dark matter search experiments employ phonon-based crystal detectors operated at cryogenic temperatures. Some of these detectors, including certain silicon detectors used by the SuperCDMS Collaboration, are able to achieve single-charge sensitivity when a voltage bias is applied across the detector. The total amount of phonon energy measured by such a detector is proportional to the number of electron-hole pairs created by the interaction. However, crystal impurities and surface effects can cause propagating charges to either become trapped inside the crystal or create additional unpaired charges, producing nonquantized measured energy as a result. A new analytical model for describing these detector response effects in phonon-based crystal detectors is presented. This model improves upon previous versions by demonstrating how the detector response, and thus the measured energy spectrum, is expected to differ depending on the source of events. We use this model to extract detector response parameters for SuperCDMS HVeV detectors, and illustrate how this robust modeling can help statistically discriminate between sources of events in order to improve the sensitivity of dark matter search experiments.


  • Top Cited Papers

    G4CMP: Condensed matter physics simulation using the Geant4 toolkit

    by M.H. Kelsey, R. Agnese, Y.F. Alam, I. Ataee Langroudy, E. Azadbakht, D. Brandt, R. Bunker, B. Cabrera, Y.-Y. Chang, H. Coombes, et al.