MDMartin Donoval

Martin Donoval

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Martin Donoval has a total of 112 co-authors. Here are the top co-authors by number of shared publications:

  • Martin Weis

    Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Ilkovičova 3, 841 04 Bratislava, Slovakia

    12 shared publications
  • Erik Vavrinsky

    Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovičova 3, 81219 Bratislava, Slovakia

    11 shared publications
  • Martin Daricek

    8 shared publications
  • Helena Kosnacova

    Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovičova 3, 81219 Bratislava, Slovakia

    7 shared publications
  • Peter Telek

    7 shared publications
  • Daniel Donoval

    Institute of Electronics and Photonics, Slovak University of Technology in Bratislava, Bratislava, Slovakia

    6 shared publications

Latest Publications

  • Top Cited Papers
    Open Access

    Advances in Respiratory Monitoring: A Comprehensive Review of Wearable and Remote Technologies

    by Diana Vitazkova, Erik Foltan, Helena Kosnacova, Michal Micjan, Martin Donoval, Anton Kuzma, Martin Kopani, Erik Vavrinsky

    This article explores the importance of wearable and remote technologies in healthcare. The focus highlights its potential in continuous monitoring, examines the specificity of the issue, and offers a view of proactive healthcare. Our research describes a wide range of device types and scientific methodologies, starting from traditional chest belts to their modern alternatives and cutting-edge bioamplifiers that distinguish breathing from chest impedance variations. We also investigated innovative technologies such as the monitoring of thorax micromovements based on the principles of seismocardiography, ballistocardiography, remote camera recordings, deployment of integrated optical fibers, or extraction of respiration from cardiovascular variables. Our review is extended to include acoustic methods and breath and blood gas analysis, providing a comprehensive overview of different approaches to respiratory monitoring. The topic of monitoring respiration with wearable and remote electronics is currently the center of attention of researchers, which is also reflected by the growing number of publications. In our manuscript, we offer an overview of the most interesting ones.


  • Open Access

    Charge Trap States of SiC Power TrenchMOS Transistor under Repetitive Unclamped Inductive Switching Stress

    by Juraj Marek, Jozef Kozarik, Michal Minarik, Aleš Chvála, Matej Matus, Martin Donoval, Lubica Stuchlikova, Martin Weis

    Silicon carbide (SiC) has been envisioned as an almost ideal material for power electronic devices; however, device reliability is still a great challenge. Here we investigate the reliability of commercial 1.2-kV 4H-SiC MOSFETs under repetitive unclamped inductive switching (UIS). The stress invoked degradation of the device characteristics, including the output and transfer characteristics, drain leakage current, and capacitance characteristics. Besides the shift of steady-state electrical characteristics, a significant change in switching times points out the charge trapping phenomenon. Transient capacitance spectroscopy was applied to investigate charge traps in the virgin device as well as after UIS stress. The intrinsic traps due to metal impurities or Z1,2 transitions were recognized in the virgin device. The UIS stress caused suppression of the second stage of the Z1,2  transition, and only the first stage, Z10, was observed. Hence, the UIS stress is causing the reduction of multiple charging of carbon vacancies in SiC-based devices.


  • Open Access

    Evaluation of Effective Mass in InGaAsN/GaAs Quantum Wells Using Transient Spectroscopy

    by Lubica Stuchlikova, Beata Sciana, Arpad Kosa, Matej Matus, Peter Benko, Juraj Marek, Martin Donoval, Wojciech Dawidowski, Damian Radziewicz, Martin Weis

    Transient spectroscopies are sensitive to charge carriers released from trapping centres in semiconducting devices. Even though these spectroscopies are mostly applied to reveal defects causing states that are localised in the energy gap, these methods also sense-charge from quantum wells in heterostructures. However, proper evaluation of material response to external stimuli requires knowledge of material properties such as electron effective mass in complex structures. Here we propose a method for precise evaluation of effective mass in quantum well heterostructures. The infinite well model is successfully applied to the InGaAsN/GaAs quantum well structure and used to evaluate electron effective mass in the conduction and valence bands. The effective mass m/m0 of charges from the conduction band was 0.093 ± 0.006, while the charges from the valence band exhibited an effective mass of 0.122 ± 0.018.


  • Open Access

    Dimensionality of photogenerated charges transport in the organic phototransistor

    by Anton Kuzma, Tomas Vincze, Michal Micjan, Juraj Nevrela, Martin Donoval, Martin Weis

    SPIE Digital Library Proceedings

  • Open Access

    The Current State of Optical Sensors in Medical Wearables

    by Erik Vavrinsky, Niloofar Ebrahimzadeh Esfahani, Michal Hausner, Anton Kuzma, Vratislav Rezo, Martin Donoval, Helena Kosnacova

    Optical sensors play an increasingly important role in the development of medical diagnostic devices. They can be very widely used to measure the physiology of the human body. Optical methods include PPG, radiation, biochemical, and optical fiber sensors. Optical sensors offer excellent metrological properties, immunity to electromagnetic interference, electrical safety, simple miniaturization, the ability to capture volumes of nanometers, and non-invasive examination. In addition, they are cheap and resistant to water and corrosion. The use of optical sensors can bring better methods of continuous diagnostics in the comfort of the home and the development of telemedicine in the 21st century. This article offers a large overview of optical wearable methods and their modern use with an insight into the future years of technology in this field.


  • Open Access

    Research and Development of a COVID-19 Tracking System in Order to Implement Analytical Tools to Reduce the Infection Risk

    by Erik Vavrinsky, Tomas Zavodnik, Tomas Debnar, Lubos Cernaj, Jozef Kozarik, Michal Micjan, Juraj Nevrela, Martin Donoval, Martin Kopani, Helena Kosnacova

    The whole world is currently focused on COVID-19, which causes considerable economic and social damage. The disease is spreading rapidly through the population, and the effort to stop the spread is entirely still failing. In our article, we want to contribute to the improvement of the situation. We propose a tracking system that would identify affected people with greater accuracy than medical staff can. The main goal was to design hardware and construct a device that would track anonymous risky contacts in areas with a highly concentrated population, such as schools, hospitals, large social events, and companies. We have chosen a 2.4 GHz proprietary protocol for contact monitoring and mutual communication of individual devices. The 2.4 GHz proprietary protocol has many advantages such as a low price and higher resistance to interference and thus offers benefits. We conducted a pilot experiment to catch bugs in the system. The device is in the form of a bracelet and captures signals from other bracelets worn at a particular location. In case of contact with an infected person, the alarm is activated. This article describes the concept of the tracking system, the design of the devices, initial tests, and plans for future use.


  • Open Access

    Photoresponse Dimensionality of Organic Field-Effect Transistor

    by Tomas Vincze, Michal Micjan, Juraj Nevrela, Martin Donoval, Martin Weis

    Organic field-effect transistors have been envisioned for advanced photodetectors because the organic semiconductors provide unique absorption characteristics, low-cost fabrication, or compatibility with flexible substrates. However, the response time of organic phototransistors still does not reach the required application level. Here, we report the photoresponse of copper phthalocyanine phototransistor in a steady state and under pulsed illumination. The detailed analysis based on the random walk among a field of traps was used to evaluate the dimensionality of electron transport in a device.


  • Open Access

    Application of Modern Multi-Sensor Holter in Diagnosis and Treatment

    by Erik Vavrinsky, Jan Subjak, Martin Donoval, Alexandra Wagner, Tomas Zavodnik, Helena Svobodova

    Modern Holter devices are very trendy tools used in medicine, research, or sport. They monitor a variety of human physiological or pathophysiological signals. Nowadays, Holter devices have been developing very fast. New innovative products come to the market every day. They have become smaller, smarter, cheaper, have ultra-low power consumption, do not limit everyday life, and allow comfortable measurements of humans to be accomplished in a familiar and natural environment, without extreme fear from doctors. People can be informed about their health and 24/7 monitoring can sometimes easily detect specific diseases, which are normally passed during routine ambulance operation. However, there is a problem with the reliability, quality, and quantity of the collected data. In normal life, there may be a loss of signal recording, abnormal growth of artifacts, etc. At this point, there is a need for multiple sensors capturing single variables in parallel by different sensing methods to complement these methods and diminish the level of artifacts. We can also sense multiple different signals that are complementary and give us a coherent picture. In this article, we describe actual interesting multi-sensor principles on the grounds of our own long-year experiences and many experiments.


  • Open Access

    Advanced Wireless Sensors Used to Monitor the Impact of Environment Design on Human Physiology

    by Erik Vavrinsky, Veronika Kotradyova, Helena Svobodova, Martin Kopani, Martin Donoval, Samuel Sedlak, Jan Subjak, Tomas Zavodnik

    Advanced Wireless Sensors Used to Monitor the Impact of Environment Design on Human Physiology


  • Hunting down the ohmic contact of organic field-effect transistor*

    by M. Micjan, M. Novota, P. Telek, M. Donoval, M. Weis

    We report properties of contact resistances observed on pentacene organic field-effect transistors (OFET) with four different source/drain electrodes, namely, copper (Cu), gold (Au), silver (Ag), and germanium (Ge). The metals were selected to provide a wide range of energy barriers for charge injection, from blocking contact to smooth injection. All OFETs exhibited strong voltage dependence of the contact resistance, even for devices with smooth injection, which is in strong disagreement with the definition of ohmic contacts. A comparison with current crowding, resistive network, Fowler–Nordheim tunneling, and electric field enhanced thermionic injection (Schottky emission) pointed to importance of local electric fields and/or electrostatic field charges.