UEUgochukwu Elele

Ugochukwu Elele

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ugochukwu Elele has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Stability and Repeatability Analysis of a Phase-Modulated Optical Fibre Sensor for Transformer Oil Ageing Detection

    by Ugochukwu Elele, Youssouf Brahami, Issouf Fofana, Azam Nekahi, Arshad Arshad, Kate McAulay

    Transformer oil ageing alters key physicochemical properties, notably the refractive index (RI), due to physical, particulate, and chemical changes. As a result, refractometric fibre-optic sensors have gained attention for enabling real-time monitoring and overcoming the limitations of traditional offline diagnostics. This study explores the use of a Fabry–Pérot phase-modulated fibre optic sensor (FISO FRI RI Sensor) for in-situ ageing detection in four industrial transformer oils: natural ester, synthetic ester, Nytro Bio 300X (vegetable-based), and Polaris GX (mineral-based). The oils were thermally aged under controlled conditions following degassing and drying. The sensor performance was evaluated using key metrics, including repeatability, thermal response, settling time, and linearity. Results show high repeatability (with standard deviations below 7 × 10−5 RIU and repeatability coefficients under 2 × 10−4 RIU), stable thermal response (~0.0004 RIU/°C), and strong thermal linearity (R2 > 0.99) across all samples. Natural ester and Nytro Bio 300X exhibited the most stable and consistent sensor responses, while synthetic ester and mineral oils showed greater variability due to temperature-induced RI shifts. These findings demonstrate the reliability and precision of this Fabry–Pérot phase-modulated sensor for online transformer oil condition monitoring, with strong potential for integration into smart grid diagnostics.


  • Oil Quality Index Model Verification and Validation Using Total Acid Number and Interfacial Tension Experimental Data

    by Ugochukwu Elele, Azam Nekahi, Arshad Arshad, Issouf Fofana, Kate McAulay

    Transformers are indispensable components in any power networks, facilitating the delivery of generated electricity to consumers at the most secure voltage level. The insulation system of oil-filled transformers is critical for the safe operation of power transformers, although it undergoes consistent degradation over time. Similar to blood in a human body, the insulating fluid serves as condition monitoring medium. Most traditional oil ageing detection methodologies operate offline; thus they are most suitable for planned maintenance activities. However, these methods have their drawbacks including potential safety risks, contamination of samples, loss of productive hours, and the potential risk of overlooking early signs of ageing that could occur beyond the maintenance cycle window. The Myers Oil Quality Index Number (OQIN), derived from the quotient of interfacial tension (IFT) and total acid number (TAN) values, provides a tool for classifying transformer oil into seven distinct categories, expanding the potential for both offline and online oil applications. In this work, eighteen 750ml samples of natural ester oil (NEO) were procured, aged, and analysed using offline TAN and IFT techniques, and their respective values (IFT, TAN, and OQIN) were recorded. These experimental data sets were employed to verify and validate (V&V) an OQIN machine learning model. The model was further validated using existing mineral oil (MIN) data sets. The high-performance metrics, demonstrated in terms of accuracy, precision, sensitivity, specificity and F-Score, confirm the effectiveness of the model for online transformer oil ageing detection and classification. The bagged tree ensemble model showed the best performance for OQIN, NEO, MIN respectively in terms of accuracy (100%, 83.30%, 100%), precision (100%, 90%, 100%), sensitivity (100%, 88%, 100%), specificity (100%, 96%, 100%) and F-Score (100%, 84.76%, 100%). This development proposes the potential for a shift from traditional offline scheduled maintenance ageing detection methods to an online/Internet of Things (IoT) - based prescriptive ageing detection, thereby enhancing the reliability of transformer performance in situ.


  • Open Access

    Sensitivity Analysis of Intensity-Modulated Plastic Optical Fiber Sensors for Effective Aging Detection in Rapeseed Transformer Oil

    by Ugochukwu Elele, Azam Nekahi, Arshad Arshad, Kate McAulay, Issouf Fofana

    As the focus tilts toward online detection methodologies for transformer oil aging, bypassing challenges associated with traditional offline methods, such as sample contamination and misinterpretation, fiber optic sensors are gaining traction due to their compact nature, cost-effectiveness, and resilience to electromagnetic disturbances that are typical in high-voltage environments. This study delves into the sensitivity analysis of intensity-modulated plastic optical fiber sensors. The investigation encompasses key determinants such as the influence of optical source wavelengths, noise response dynamics, ramifications of varying sensing lengths, and repeatability assessments. Our findings highlight that elongating sensing length detrimentally affects both linearity response and repeatability, largely attributed to a diminished resistance to noise. Additionally, the choice of the optical source wavelength proved to be a critical variable in assessing sensor sensitivity.


  • Open Access

    Sensitivity Analysis of Intensity-Modulated Plastic Optical Fiber Sensors for Effective Ageing Detection in Rapeseed Transformer Oil

    by Ugochukwu Elele, Azam Nekahi, Arshad Arshad, Kate McAulay, Issouf Fofana

    In the realm of power delivery to end-users, transformers are indispensable, with their malfunctions leading to substantial economic, safety, and environmental repercussions. The need for persistent surveillance is accentuated for in-situ oil-filled transformers, given the potential degradation of oil and the emergence of related ageing by-products. As the focus tilts towards online detection methodologies for transformer oil ageing, bypassing challenges associated with traditional offline methods such as sample contamination and misinterpretation, fiber optic sensors are gaining trac-tion due to their compact nature, cost-effectiveness, and resilience to electromagnetic disturbances typical in high-voltage environments. This work delves into the sensitivity analysis of intensi-ty-modulated plastic optical fiber sensors. The investigation encompasses key determinants such as the influence of optical source wavelengths, noise response dynamics, ramifications of varying sensing lengths, and repeatability assessments. Findings underscore that elongating the sensing length detrimentally affects both the linearity response and repeatability, largely attributed to the diminished resistance to external noise. Additionally, the choice of the optical source wavelength proved to be a critical variable in assessing sensor sensitivity.


  • Open Access

    Towards Online Ageing Detection in Transformer Oil: A Review

    by Ugochukwu Elele, Azam Nekahi, Arshad Arshad, Issouf Fofana

    Transformers play an essential role in power networks, ensuring that generated power gets to consumers at the safest voltage level. However, they are prone to insulation failure from ageing, which has fatal and economic consequences if left undetected or unattended. Traditional detection methods are based on scheduled maintenance practices that often involve taking samples from in situ transformers and analysing them in laboratories using several techniques. This conventional method exposes the engineer performing the test to hazards, requires specialised training, and does not guarantee reliable results because samples can be contaminated during collection and transportation. This paper reviews the transformer oil types and some traditional ageing detection methods, including breakdown voltage (BDV), spectroscopy, dissolved gas analysis, total acid number, interfacial tension, and corresponding regulating standards. In addition, a review of sensors, technologies to improve the reliability of online ageing detection, and related online transformer ageing systems is covered in this work. A non-destructive online ageing detection method for in situ transformer oil is a better alternative to the traditional offline detection method. Moreover, when combined with the Internet of Things (IoT) and artificial intelligence, a prescriptive maintenance solution emerges, offering more advantages and robustness than offline preventive maintenance approaches.


  • Computerized Automatic Three Phase Data Logger for Power Stations

    by Nkolika O.Nwazor, Ugochukwu Elele

    Computerized Automatic Three Phase Data Logger for Power Stations