Katsuhiro Dobashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Katsuhiro Dobashi has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jian Yang
Department of Nuclear Engineering and Management, School of Engineering, The University of Tokyo, Tokyo 113-8654, Japan
2 shared publications - Joichi Kusano
Accuthera Inc., Kanagawa 215-0033, Japan
2 shared publications - Yuki Mitsuya
The University of Tokyo
2 shared publications - Mitsuru Uesaka
Nuclear Engineering Research Laboratory, Graduate School of Engineering, The University of Tokyo, 22-2 Shirane-shirakata, Tokai, Naka, Ibaraki 319-1188, Japan
1 shared publication - Mitsuru Uesaka
The University of Tokyo
1 shared publication - Yoshiyuki Iizuka
Atox Co., LTD., Tokyo 108-0014, Japan
1 shared publication
Latest Publications
- Open Access
- 25 August 2021
- Published by IntechOpen
Highway PC Bridge Inspection by 3.95 MeV X-Ray/Neutron Source
We have developed portable 950 keV/3.95 MeV X-ray/neutron sources and applied them to inspection of PC concrete thicker than 200 mm within reasonable measuring time of seconds - minutes. T-girder-, Box- and slab- bridges are considered. Now we are to start X-ray transmission inspection for highway PC bridge (box) by using 3.95 MeV X-ray sources in Japan in 2020. By obtaining X-ray transmission images of no-grout-filling in PC sheath and thinning of PC wires, we plan to carry out numerical structural analysis to evaluate the degradation of strength. Finally, we are going to propose a technical guideline of nondestructive evaluation (NDE) of PC bridges by taking account of both X-ray inspection and structural analysis. Further, we are trying to detect rainwater detection in PC sheath, and asphalt and floor slab by the 3.95 MeV neutron source. This is expected to be an early degradation inspection. We have done preliminary experiments on X-ray transmission imaging of PC wires and on-grout-filling in the same height PCs in 450–750 mm thick concretes. Moreover, neutron back scattering detection of water in PC sheath is also explained.
- 25 August 2021
- Published by IntechOpen
Open AccessHighway PC Bridge Inspection by 3.95 MeV X-Ray/Neutron Source
We have developed portable 950 keV/3.95 MeV X-ray/neutron sources and applied them to inspection of PC concrete thicker than 200 mm within reasonable measuring time of seconds - minutes. T-girder-, Box- and slab- bridges are considered. Now we are to start X-ray transmission inspection for highway PC bridge (box) by using 3.95 MeV X-ray sources in Japan in 2020. By obtaining X-ray transmission images of no-grout-filling in PC sheath and thinning of PC wires, we plan to carry out numerical structural analysis to evaluate the degradation of strength. Finally, we are going to propose a technical guideline of nondestructive evaluation (NDE) of PC bridges by taking account of both X-ray inspection and structural analysis. Further, we are trying to detect rainwater detection in PC sheath, and asphalt and floor slab by the 3.95 MeV neutron source. This is expected to be an early degradation inspection. We have done preliminary experiments on X-ray transmission imaging of PC wires and on-grout-filling in the same height PCs in 450–750 mm thick concretes. Moreover, neutron back scattering detection of water in PC sheath is also explained.
- Open Access
- 15 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (12) , 5525
Quantitative Evaluation of Unfilled Grout in Tendons of Prestressed Concrete Girder Bridges by Portable 950 keV/3.95 MeV X-ray Sources
We have developed porTable 950 keV/3.95 MeV X-band (9.3 GHz) electron linear accelerator (LINAC)-based X-ray sources and conducted onsite prestressed concrete (PC) bridge inspection in the last 10 years. A T-shaped PC girder bridge with a thickness of 200–400 mm and a box-shaped PC girder bridge with a thickness of 200–800 mm were tested. X-ray transmission images of flaws such as thinning, fray, and disconnection caused by corrosion of PC wires and unfilled grout were observed. A three-dimensional structural analysis was performed to estimate the reduction in the yield stress of the bridge. In this study, we attempted to evaluate the unfilled grout quantitatively because it is the main flaw that results in water filling and corrosion. In the measured X-ray images, we obtained gray values, which correspond to the X-ray attenuation coefficients of filled/unfilled grouts, PC wires (steel) in a sheath, and concrete. Then, we compared the ratio of the gray values of the filled/unfilled grouts and PC wires to determine the stage of the unfilled grout. We examined this quantitative evaluation using the data obtained from a real T-shaped PC girder bridge and model samples to simulate thick box-shaped PC girder bridges. We obtained a clear quantitative difference in the ratios for unfilled and filled grouts, which coincided with our visual perception. We synthesized the experience and data and proposed a quantitative analysis for evaluating the unfilled grout for subsequent steps such as structural analysis and destructive evaluation by boring surveys.
- 15 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (12) , 5525
Open AccessQuantitative Evaluation of Unfilled Grout in Tendons of Prestressed Concrete Girder Bridges by Portable 950 keV/3.95 MeV X-ray Sources
We have developed porTable 950 keV/3.95 MeV X-band (9.3 GHz) electron linear accelerator (LINAC)-based X-ray sources and conducted onsite prestressed concrete (PC) bridge inspection in the last 10 years. A T-shaped PC girder bridge with a thickness of 200–400 mm and a box-shaped PC girder bridge with a thickness of 200–800 mm were tested. X-ray transmission images of flaws such as thinning, fray, and disconnection caused by corrosion of PC wires and unfilled grout were observed. A three-dimensional structural analysis was performed to estimate the reduction in the yield stress of the bridge. In this study, we attempted to evaluate the unfilled grout quantitatively because it is the main flaw that results in water filling and corrosion. In the measured X-ray images, we obtained gray values, which correspond to the X-ray attenuation coefficients of filled/unfilled grouts, PC wires (steel) in a sheath, and concrete. Then, we compared the ratio of the gray values of the filled/unfilled grouts and PC wires to determine the stage of the unfilled grout. We examined this quantitative evaluation using the data obtained from a real T-shaped PC girder bridge and model samples to simulate thick box-shaped PC girder bridges. We obtained a clear quantitative difference in the ratios for unfilled and filled grouts, which coincided with our visual perception. We synthesized the experience and data and proposed a quantitative analysis for evaluating the unfilled grout for subsequent steps such as structural analysis and destructive evaluation by boring surveys.