Mohamed Boudour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohamed Boudour has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Mohamed Menaa
Laboratoire des Systemes Electriques et Industriels, Faculte d’Informatique et d’Electronique Universite des Sciences et de la Technologie Houari Boumediene, Bab Ezzouar, Alger, Algerie
22 shared publications - Mourad Hasni
Laboratory of Electrical Industrial Systems (LSEI), University of Sciences and Technology Houari Boumediene, Bab Ezzouar, Algiers, Algeria
18 shared publications - Ahmed Amine Ladjici
Faculty of Electrical Engineering, University of Sciences and Technology Houari Boumediene, Algiers 16111, Algeria
16 shared publications - Youssouf Amrane
Laboratory of Electrical and Industrial Systems, University of Science and Technology Houari Boumediene, Algiers, Algeria
13 shared publications A. Hellal
7 shared publications- Ahmed Tiguercha
Electrical Engineering Department, University of Sciences and Technology Houari Boumedien, City Alia, Bab Ezzouar, Algiers, Algeria BP 16111
7 shared publications
Latest Publications
- Open Access
- 2 March 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 2,p. 59-66
Comparative analysis of numerical, evolutionary and metaheuristic methods for experimental implementation of selective harmonic elimination in a five-level emerging inverter
Introduction. Multilevel inverters (MLIs) are widely used in renewable energy conversion and high-performance power applications due to their ability to generate output voltages with low harmonic distortion and reduced switching stress. Selective harmonic elimination (SHE) remains one of the most effective modulation strategies for suppressing low-order harmonics; however, its practical implementation relies on solving nonlinear transcendental equations that often require robust and efficient computational methods. Problem. Determining optimal switching angles for SHE in MLIs remains a challenging optimization problem because of the nonlinear, non-convex nature of the governing equations and the need to simultaneously preserve the fundamental voltage component while eliminating selected harmonics. The choice of an appropriate numerical or optimization-based solution method directly affects computational efficiency, robustness, and practical implementability. The goal of the work is the reducing harmonic distortion of output voltage and determining optimal switching angles of a single-phase 5-level inverter using the Newton-Raphson (NR) method, particle swarm optimization (PSO) and genetic algorithm (GA). Methodology. The operating principle and harmonic model of the inverter are first established using Fourier series analysis. The SHE problem is formulated as a system of nonlinear equations subject to ordering constraints. The NR method is used as a fast numerical solver, while PSO and GA are employed as evolutionary and metaheuristic optimization techniques capable of handling non-convex search spaces. All algorithms are implemented in MATLAB/Simulink over a range of modulation indices. Experimental validation is carried out using an Arduino Mega 2560-based prototype, where the optimized switching patterns are executed in real time and the output voltage is analyzed using oscilloscope and harmonic measurement tools. Results. The three approaches converge to identical switching-angle solutions over the investigated modulation range, confirming the consistency of the formulation. Simulation results demonstrate effective elimination of the 3rd harmonic and its multiples, with the total harmonic distortion of the output voltage decreasing from 28.42 % at M = 0.55, f = 1 kHz to 14.88 % at M = 0.55, f = 10 kHz. In terms of computational efficiency, NR-SHE achieves the shortest execution time (0.516 s), while PSO-SHE (10.237 s) and GA-SHE (23.289 s) require longer computation. Experimental waveforms and harmonic spectra closely match the simulation results, validating the proposed approach. Scientific novelty. This work provides a unified comparative analysis of numerical, evolutionary and metaheuristic methods for SHE applied to a 5-level emerging inverter with a reduced switch count (6 switches instead of 8 in a conventional 5-level H-bridge). In addition, it demonstrates the feasibility of executing SHE-based modulation schemes on a low-cost Arduino microcontroller. Practical value. The presented results offer practical guidance for selecting suitable computational methods for SHE in MLIs and confirm that efficient harmonic control can be achieved using inexpensive embedded platforms. The findings are relevant for research, prototyping and educational applications in industrial electronics and power conversion systems. References 21, tables 5, figures 12.
- 2 March 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 2,p. 59-66
Open AccessComparative analysis of numerical, evolutionary and metaheuristic methods for experimental implementation of selective harmonic elimination in a five-level emerging inverter
Introduction. Multilevel inverters (MLIs) are widely used in renewable energy conversion and high-performance power applications due to their ability to generate output voltages with low harmonic distortion and reduced switching stress. Selective harmonic elimination (SHE) remains one of the most effective modulation strategies for suppressing low-order harmonics; however, its practical implementation relies on solving nonlinear transcendental equations that often require robust and efficient computational methods. Problem. Determining optimal switching angles for SHE in MLIs remains a challenging optimization problem because of the nonlinear, non-convex nature of the governing equations and the need to simultaneously preserve the fundamental voltage component while eliminating selected harmonics. The choice of an appropriate numerical or optimization-based solution method directly affects computational efficiency, robustness, and practical implementability. The goal of the work is the reducing harmonic distortion of output voltage and determining optimal switching angles of a single-phase 5-level inverter using the Newton-Raphson (NR) method, particle swarm optimization (PSO) and genetic algorithm (GA). Methodology. The operating principle and harmonic model of the inverter are first established using Fourier series analysis. The SHE problem is formulated as a system of nonlinear equations subject to ordering constraints. The NR method is used as a fast numerical solver, while PSO and GA are employed as evolutionary and metaheuristic optimization techniques capable of handling non-convex search spaces. All algorithms are implemented in MATLAB/Simulink over a range of modulation indices. Experimental validation is carried out using an Arduino Mega 2560-based prototype, where the optimized switching patterns are executed in real time and the output voltage is analyzed using oscilloscope and harmonic measurement tools. Results. The three approaches converge to identical switching-angle solutions over the investigated modulation range, confirming the consistency of the formulation. Simulation results demonstrate effective elimination of the 3rd harmonic and its multiples, with the total harmonic distortion of the output voltage decreasing from 28.42 % at M = 0.55, f = 1 kHz to 14.88 % at M = 0.55, f = 10 kHz. In terms of computational efficiency, NR-SHE achieves the shortest execution time (0.516 s), while PSO-SHE (10.237 s) and GA-SHE (23.289 s) require longer computation. Experimental waveforms and harmonic spectra closely match the simulation results, validating the proposed approach. Scientific novelty. This work provides a unified comparative analysis of numerical, evolutionary and metaheuristic methods for SHE applied to a 5-level emerging inverter with a reduced switch count (6 switches instead of 8 in a conventional 5-level H-bridge). In addition, it demonstrates the feasibility of executing SHE-based modulation schemes on a low-cost Arduino microcontroller. Practical value. The presented results offer practical guidance for selecting suitable computational methods for SHE in MLIs and confirm that efficient harmonic control can be achieved using inexpensive embedded platforms. The findings are relevant for research, prototyping and educational applications in industrial electronics and power conversion systems. References 21, tables 5, figures 12.
- 1 July 2024
- Published by AEDERMACP (European Association for the Development of Renewable Energies and Power Quality) in Energies and Quality Journal
- Vol. 2, 78-83
Enhancing Distribution Grid Resilience via Multi-Autonomous Microgrid Islanding
The ability of power systems to withstand and recover from natural events, like storms, earthquakes and floods is referred to as resilience. These events may not happen often. They can cause damage to infrastructure and disrupt the supply of electricity. That's why it's crucial to consider resilience when planning and operating networks. In this paper we present a method to enhance the resilience of distribution networks these are the parts of the system for delivering power to end users. Our approach involves dividing the distribution network into subnetworks called microgrids. Each microgrid operates independently. Includes sources of generation loads (consumers) and storage devices. These microgrids can function as part of the grid. Operate autonomously in what we call island mode during major disturbances. In situations they can isolate themselves from the grid and use their internal resources to continue providing electricity specifically for critical needs. To assess how well our approach performs we introduce a measure called a resilience indicator. This indicator evaluates how effectively users electricity demands are met during and after a disturbance occurs. It can be calculated individually for each microgrid or holistically, for the distribution network by considering how these microgrids interact with each other. Our research demonstrates that the method we propose can improve the reliability of the power distribution network. We achieved this by comparing the results obtained from our approach with those, from a network that does not use microgrids. Our paper adds to the existing knowledge, on the resilience of power systems by introducing a technique centered around creating multiple independent microgrids. Key words. Resilience, Electrical power systems, Microgrids, Islanding and Extreme natural events.
- 1 July 2024
- Published by AEDERMACP (European Association for the Development of Renewable Energies and Power Quality) in Energies and Quality Journal
- Vol. 2, 78-83
Enhancing Distribution Grid Resilience via Multi-Autonomous Microgrid Islanding
The ability of power systems to withstand and recover from natural events, like storms, earthquakes and floods is referred to as resilience. These events may not happen often. They can cause damage to infrastructure and disrupt the supply of electricity. That's why it's crucial to consider resilience when planning and operating networks. In this paper we present a method to enhance the resilience of distribution networks these are the parts of the system for delivering power to end users. Our approach involves dividing the distribution network into subnetworks called microgrids. Each microgrid operates independently. Includes sources of generation loads (consumers) and storage devices. These microgrids can function as part of the grid. Operate autonomously in what we call island mode during major disturbances. In situations they can isolate themselves from the grid and use their internal resources to continue providing electricity specifically for critical needs. To assess how well our approach performs we introduce a measure called a resilience indicator. This indicator evaluates how effectively users electricity demands are met during and after a disturbance occurs. It can be calculated individually for each microgrid or holistically, for the distribution network by considering how these microgrids interact with each other. Our research demonstrates that the method we propose can improve the reliability of the power distribution network. We achieved this by comparing the results obtained from our approach with those, from a network that does not use microgrids. Our paper adds to the existing knowledge, on the resilience of power systems by introducing a technique centered around creating multiple independent microgrids. Key words. Resilience, Electrical power systems, Microgrids, Islanding and Extreme natural events.
- 28 January 2023
- Published by Springer Nature in Journal of Failure Analysis and Prevention
- Vol. 23 (2) , 751-766
Reliability Evaluation of an NPP’s Emergency Power Supply System Considering Uncertainty, Sensitivity and Testing Interval Analyses
- 28 January 2023
- Published by Springer Nature in Journal of Failure Analysis and Prevention
- Vol. 23 (2) , 751-766
Reliability Evaluation of an NPP’s Emergency Power Supply System Considering Uncertainty, Sensitivity and Testing Interval Analyses
- Open Access
- 21 May 2020
- Published by Faculty of Engineering, University of Rijeka in Engineering review
- Vol. 40 (3) , 21-31
Harmonic interaction of a static Var compensator with AC power system containing multiple non-linear loads
In this paper a study of the impact of the harmonics generated by a static Var compensator (SVC) is presented. The SVC is modeled, in the harmonic domain, as a coupled current source by using the complex Fourier transforms. Then, this...
- 21 May 2020
- Published by Faculty of Engineering, University of Rijeka in Engineering review
- Vol. 40 (3) , 21-31
Open AccessHarmonic interaction of a static Var compensator with AC power system containing multiple non-linear loads
In this paper a study of the impact of the harmonics generated by a static Var compensator (SVC) is presented. The SVC is modeled, in the harmonic domain, as a coupled current source by using the complex Fourier transforms. Then, this...
- Open Access
- 1 July 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (14) , 2919-2929
Intelligent non‐linear dynamic equivalent approach applied to Algerian power system
Aggregate or reduced power systems are often needed by operators and engineers to minimise the interconnection complexity and time simulation, without neglecting the effect of the interconnected area on internal system transient or dynamic stability study. In this work, a non‐linear power system dynamic reduction is carried out by combining the diversity of solutions obtained with genetic algorithms and the accuracy of Newtonian methods when one is close to the solution. The network is divided into two parts; the first part called the study system, and the second is the external system, which is to be replaced by an equivalent. Using the proposed equivalent estimation procedure, the network model is kept non‐linear in both the study and the external systems; the obtained equivalent model is a non‐linear model with online possibility application. The proposed approach is tested with IEEE 10‐machine‐39Bus, IEEE 16‐machine‐68Bus and the Algerian power system with 90‐machine‐673Bus. The results prove that the designed equivalent represents faithfully the behaviour of the original system. The estimated equivalent system is ten times faster than real‐time dynamic simulation for the Algerian network.
- 1 July 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (14) , 2919-2929
Open AccessIntelligent non‐linear dynamic equivalent approach applied to Algerian power system
Aggregate or reduced power systems are often needed by operators and engineers to minimise the interconnection complexity and time simulation, without neglecting the effect of the interconnected area on internal system transient or dynamic stability study. In this work, a non‐linear power system dynamic reduction is carried out by combining the diversity of solutions obtained with genetic algorithms and the accuracy of Newtonian methods when one is close to the solution. The network is divided into two parts; the first part called the study system, and the second is the external system, which is to be replaced by an equivalent. Using the proposed equivalent estimation procedure, the network model is kept non‐linear in both the study and the external systems; the obtained equivalent model is a non‐linear model with online possibility application. The proposed approach is tested with IEEE 10‐machine‐39Bus, IEEE 16‐machine‐68Bus and the Algerian power system with 90‐machine‐673Bus. The results prove that the designed equivalent represents faithfully the behaviour of the original system. The estimated equivalent system is ten times faster than real‐time dynamic simulation for the Algerian network.
- 27 March 2019
- Published by Springer Nature in International Journal of Dynamics and Control
- Vol. 7 (3) , 1005-1014
Doubly fed induction wind generators model and field orientation vector control design and implementation on FPGA
- 27 March 2019
- Published by Springer Nature in International Journal of Dynamics and Control
- Vol. 7 (3) , 1005-1014
Doubly fed induction wind generators model and field orientation vector control design and implementation on FPGA
- 1 March 2019
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 8 (1) , 10-20
Wavelet energy moment and neural networks based particle swarm optimisation for transmission line protection
In this study, a combined approach of discrete wavelet transform analysis and a feed forward neural networks algorithm to detect and classify transmission line faults. The proposed algorithm uses a multi -resolution analysis decoposition of three-phasecurrents only to calculate the wavelet energy moment of detailed coefficients. In comparison with the energy spectrum, the energy moment could reveal the energy distribution features better, which is beneficial when extracting signal features. Theapproach use particle swarm optimization algorithm to train a feed forward neural network. The goal is the enhancement of the convergence rate, learning process and fill up the gap of local minimum point.The purposed scheme consists of two FNNs, one for detecting and another for classifying all the ten types of faults using Matlab/Simulink. The proposed algorithm have been extensively tested on a system 400 kV, 3 phases, 100 km line consideringvarious fault parameter variations.
- 1 March 2019
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 8 (1) , 10-20
Wavelet energy moment and neural networks based particle swarm optimisation for transmission line protection
In this study, a combined approach of discrete wavelet transform analysis and a feed forward neural networks algorithm to detect and classify transmission line faults. The proposed algorithm uses a multi -resolution analysis decoposition of three-phasecurrents only to calculate the wavelet energy moment of detailed coefficients. In comparison with the energy spectrum, the energy moment could reveal the energy distribution features better, which is beneficial when extracting signal features. Theapproach use particle swarm optimization algorithm to train a feed forward neural network. The goal is the enhancement of the convergence rate, learning process and fill up the gap of local minimum point.The purposed scheme consists of two FNNs, one for detecting and another for classifying all the ten types of faults using Matlab/Simulink. The proposed algorithm have been extensively tested on a system 400 kV, 3 phases, 100 km line consideringvarious fault parameter variations.
- 1 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Frequency Tracking for Accurate Synchrophasor Measurement Under Steady State and Dynamic Conditions
This paper focuses on the use of the three-point IpDFT algorithm to track the variation of the power system frequency and use this estimate as a sampling clock frequency of the Analog to Digital converter of the PMU (phasor measurement unit). This new approach improves the accuracy of the synchrophasor that is based on the joint application of the Modulated Sliding DFT and the Taylor's series expansion. The accuracy requirements of the IEEE Std C37.118.1™-2011 and its latest amendment IEEE Std C37.118.1a™-2014 under steady-state and dynamic environments are analyzed and discussed.
- 1 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Frequency Tracking for Accurate Synchrophasor Measurement Under Steady State and Dynamic Conditions
This paper focuses on the use of the three-point IpDFT algorithm to track the variation of the power system frequency and use this estimate as a sampling clock frequency of the Analog to Digital converter of the PMU (phasor measurement unit). This new approach improves the accuracy of the synchrophasor that is based on the joint application of the Modulated Sliding DFT and the Taylor's series expansion. The accuracy requirements of the IEEE Std C37.118.1™-2011 and its latest amendment IEEE Std C37.118.1a™-2014 under steady-state and dynamic environments are analyzed and discussed.
- 1 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Harmonic Impedance Response Of Electrical Algerian Network
This paper investigates the impedance behavior of the large electrical power system with consideration of the capacitor bank and multiple nonlinear loads. Two methods have been used to predict the harmonic problems under these non sinusoidal conditions, which are the harmonic power flow and frequency scan. Both methods have been applied to the Algerian 114 buses equivalent network. The obtained results show the robustness of these tools to give some information about the resonance conditions at any bus and to visualize the frequency response of the Algerian network as function of the capacitor sizing and placement as well as nonlinear load position.
- 1 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Harmonic Impedance Response Of Electrical Algerian Network
This paper investigates the impedance behavior of the large electrical power system with consideration of the capacitor bank and multiple nonlinear loads. Two methods have been used to predict the harmonic problems under these non sinusoidal conditions, which are the harmonic power flow and frequency scan. Both methods have been applied to the Algerian 114 buses equivalent network. The obtained results show the robustness of these tools to give some information about the resonance conditions at any bus and to visualize the frequency response of the Algerian network as function of the capacitor sizing and placement as well as nonlinear load position.