Xin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Xin Zhang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bo Tang
College of Food and Bioengineering, Bengbu University, Bengbu 233030, China
1 shared publication - Chengbin Liu
School of Life Science and Agricultural Engineering, Nanyang Normal University, Nanyang 473061, China
1 shared publication - Pengfei Jiao
School of Life Science and Agricultural Engineering, Nanyang Normal University, Nanyang 473061, China
1 shared publication - Yansong Li
School of Life Science and Agricultural Engineering, Nanyang Normal University, Nanyang 473061, China
1 shared publication - Yuping Wei
School of Life Science and Agricultural Engineering, Nanyang Normal University, Nanyang 473061, China
1 shared publication
Latest Publications
- Open Access
- 15 June 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (6) , 1575
Molecularly Imprinted Magnetic Fluorescent Nanocomposite-Based Sensor for Selective Detection of Lysozyme
A new strategy for the design and construction of molecularly imprinted magnetic fluorescent nanocomposite-based-sensor is proposed. This multifunctional nanocomposite exhibits the necessary optics, magnetism and biocompatibility for use in the selective fluorescence detection of lysozyme. The magnetic fluorescent nanocomposites are prepared by combining carboxyl- functionalized Fe3O4 magnetic nanoparticles with l-cysteine-modified zinc sulfide quantum dots (MNP/QDs). Surface molecular imprinting technology was employed to coat the lysozyme molecularly imprinted polymer (MIP) layer on the MNP/QDs to form a core-shell structure. The molecularly imprinted MNP/QDs (MNP/QD@MIPs) can rapidly separate the target protein and then use fluorescence sensing to detect the protein; this reduces the background interference, and the selectivity and sensitivity of the detection are improved. The molecularly imprinted MNP/QDs sensor presented good linearity over a lysozyme concentration range from 0.2 to 2.0 μM and a detection limit of 4.53 × 10−3 μM for lysozyme. The imprinting factor of the MNP/QD@MIPs was 4.12, and the selectivity coefficient ranged from 3.19 to 3.85. Furthermore, the MNP/QD@MIPs sensor was applied to detect of lysozyme in human urine and egg white samples with recoveries of 95.40–103.33%. Experimental results showed that the prepared MNP/QD@MIPs has potential for selective magnetic separation and fluorescence sensing of target proteins in biological samples.
- 15 June 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (6) , 1575
Open AccessMolecularly Imprinted Magnetic Fluorescent Nanocomposite-Based Sensor for Selective Detection of Lysozyme
A new strategy for the design and construction of molecularly imprinted magnetic fluorescent nanocomposite-based-sensor is proposed. This multifunctional nanocomposite exhibits the necessary optics, magnetism and biocompatibility for use in the selective fluorescence detection of lysozyme. The magnetic fluorescent nanocomposites are prepared by combining carboxyl- functionalized Fe3O4 magnetic nanoparticles with l-cysteine-modified zinc sulfide quantum dots (MNP/QDs). Surface molecular imprinting technology was employed to coat the lysozyme molecularly imprinted polymer (MIP) layer on the MNP/QDs to form a core-shell structure. The molecularly imprinted MNP/QDs (MNP/QD@MIPs) can rapidly separate the target protein and then use fluorescence sensing to detect the protein; this reduces the background interference, and the selectivity and sensitivity of the detection are improved. The molecularly imprinted MNP/QDs sensor presented good linearity over a lysozyme concentration range from 0.2 to 2.0 μM and a detection limit of 4.53 × 10−3 μM for lysozyme. The imprinting factor of the MNP/QD@MIPs was 4.12, and the selectivity coefficient ranged from 3.19 to 3.85. Furthermore, the MNP/QD@MIPs sensor was applied to detect of lysozyme in human urine and egg white samples with recoveries of 95.40–103.33%. Experimental results showed that the prepared MNP/QD@MIPs has potential for selective magnetic separation and fluorescence sensing of target proteins in biological samples.