Sebastian Shaner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sebastian Shaner has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Maria Asplund
Chalmers University of Technology
8 shared publications - José Leal
Department of Microsystems Engineering University of Freiburg Georges‐Köhler‐Allee 201 79110 Freiburg Germany
5 shared publications Nicole Jedrusik
Department of Microsystems Engineering (IMTEK), University of Freiburg
4 shared publications- Andreas Vlachos
Department of Neuroanatomy, Institute of Anatomy and Cell Biology, Faculty of Medicine, University of Freiburg, 79104 Freiburg, Germany
3 shared publications Anna Savelyeva
Department of Microsystems Engineering (IMTEK), University of Freiburg
3 shared publicationsMaria Asplund
3 shared publications
Latest Publications
- Open Access
- 9 March 2024
- Published by Wiley in Advanced Science
- Vol. 11 (27) , e2306244
Bioelectronic Direct Current Stimulation at the Transition Between Reversible and Irreversible Charge Transfer
Many biological processes rely on endogenous electric fields (EFs), including tissue regeneration, cell development, wound healing, and cancer metastasis. Mimicking these biological EFs by applying external direct current stimulation (DCS) is therefore the key to many new therapeutic strategies. During DCS, the charge transfer from electrode to tissue relies on a combination of reversible and irreversible electrochemical processes, which may generate toxic or bio‐altering substances, including metal ions and reactive oxygen species (ROS). Poly(3,4‐ethylenedioxythiophene) (PEDOT) based electrodes are emerging as suitable candidates for DCS to improve biocompatibility compared to metals. This work addresses whether PEDOT electrodes can be tailored to favor reversible biocompatible charge transfer. To this end, different PEDOT formulations and their respective back electrodes are studied using cyclic voltammetry, chronopotentiometry, and direct measurements of H2O2and O2. This combination of electrochemical methods sheds light on the time dynamics of reversible and irreversible charge transfer and the relationship between capacitance and ROS generation. The results presented here show that although all electrode materials investigated generate ROS, the onset of ROS can be delayed by increasing the electrode's capacitance via PEDOT coating, which has implications for future bioelectronic devices that allow longer reversibly driven pulse durations during DCS.
- 9 March 2024
- Published by Wiley in Advanced Science
- Vol. 11 (27) , e2306244
Open AccessBioelectronic Direct Current Stimulation at the Transition Between Reversible and Irreversible Charge Transfer
Many biological processes rely on endogenous electric fields (EFs), including tissue regeneration, cell development, wound healing, and cancer metastasis. Mimicking these biological EFs by applying external direct current stimulation (DCS) is therefore the key to many new therapeutic strategies. During DCS, the charge transfer from electrode to tissue relies on a combination of reversible and irreversible electrochemical processes, which may generate toxic or bio‐altering substances, including metal ions and reactive oxygen species (ROS). Poly(3,4‐ethylenedioxythiophene) (PEDOT) based electrodes are emerging as suitable candidates for DCS to improve biocompatibility compared to metals. This work addresses whether PEDOT electrodes can be tailored to favor reversible biocompatible charge transfer. To this end, different PEDOT formulations and their respective back electrodes are studied using cyclic voltammetry, chronopotentiometry, and direct measurements of H2O2and O2. This combination of electrochemical methods sheds light on the time dynamics of reversible and irreversible charge transfer and the relationship between capacitance and ROS generation. The results presented here show that although all electrode materials investigated generate ROS, the onset of ROS can be delayed by increasing the electrode's capacitance via PEDOT coating, which has implications for future bioelectronic devices that allow longer reversibly driven pulse durations during DCS.
- Open Access
- 30 October 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (23) , 4967-4985
Brain stimulation-on-a-chip: a neuromodulation platform for brain slices
Electrical stimulation of ex vivo brain tissue slices has been a method used to understand mechanisms imparted by transcranial direct current stimulation (tDCS), but there are significant direct current electric field (dcEF) dosage and electrochemical by-product concerns in conventional experimental setups that may impact translational findings. Therefore, we developed an on-chip platform with fluidic, electrochemical, and magnetically-induced spatial control. Fluidically, the chamber geometrically confines precise dcEF delivery to the enclosed brain slice and allows for tissue recovery in order to monitor post-stimulation effects. Electrochemically, conducting hydrogel electrodes mitigate stimulation-induced faradaic reactions typical of commonly-used metal electrodes. Magnetically, we applied ferromagnetic substrates beneath the tissue and used an external permanent magnet to enable in situ rotational control in relation to the dcEF. By combining the microfluidic chamber with live-cell calcium imaging and electrophysiological recordings, we showcased the potential to study the acute and lasting effects of dcEFs with the potential of providing multi-session stimulation. This on-chip bioelectronic platform presents a modernized yet simple solution to electrically stimulate explanted tissue by offering more environmental control to users, which unlocks new opportunities to conduct thorough brain stimulation mechanistic investigations.
- 30 October 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (23) , 4967-4985
Open AccessBrain stimulation-on-a-chip: a neuromodulation platform for brain slices
Electrical stimulation of ex vivo brain tissue slices has been a method used to understand mechanisms imparted by transcranial direct current stimulation (tDCS), but there are significant direct current electric field (dcEF) dosage and electrochemical by-product concerns in conventional experimental setups that may impact translational findings. Therefore, we developed an on-chip platform with fluidic, electrochemical, and magnetically-induced spatial control. Fluidically, the chamber geometrically confines precise dcEF delivery to the enclosed brain slice and allows for tissue recovery in order to monitor post-stimulation effects. Electrochemically, conducting hydrogel electrodes mitigate stimulation-induced faradaic reactions typical of commonly-used metal electrodes. Magnetically, we applied ferromagnetic substrates beneath the tissue and used an external permanent magnet to enable in situ rotational control in relation to the dcEF. By combining the microfluidic chamber with live-cell calcium imaging and electrophysiological recordings, we showcased the potential to study the acute and lasting effects of dcEFs with the potential of providing multi-session stimulation. This on-chip bioelectronic platform presents a modernized yet simple solution to electrically stimulate explanted tissue by offering more environmental control to users, which unlocks new opportunities to conduct thorough brain stimulation mechanistic investigations.
- Open Access
- 27 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Bioelectronic direct current stimulation at the transition between reversible and irreversible charge injection
Many biological processes rely on endogenous electric fields (EFs), including tissue regeneration, cell development, wound healing and cancer metastasis. Mimicking these biological EFs by applying external direct current stimulation (DCS) is therefore the key to many new therapeutic strategies. During DCS, the charge transfer from electrode to tissue relies on a combination of reversible and irreversible electrochemical processes, which may generate toxic or bio-altering substances, including metal ions and reactive oxygen species (ROS). Poly(3,4-ethylenedioxythophene) (PEDOT) based electrodes are emerging as suitable candidates for DCS to improve the biocompatibility compared to metals. This work addresses whether PEDOT electrodes can be tailored to favor reversible biocompatible charge injection. To this end, different PEDOT formulations and their respective back electrodes are studied using cyclic voltammetry, chronopotentiometry, and direct measurements of H2O2 and O2. This combination of electrochemical methods sheds light on the time dynamics of reversible and irreversible charge transfer and the relationship between capacitance and ROS generation. The results presented here show that although all electrode materials investigated generate ROS, the onset of ROS can be delayed by increasing the electrode’s capacitance, which has implications for future bioelectronic devices that allow longer reversibly driven pulse durations during DCS.
- 27 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessBioelectronic direct current stimulation at the transition between reversible and irreversible charge injection
Many biological processes rely on endogenous electric fields (EFs), including tissue regeneration, cell development, wound healing and cancer metastasis. Mimicking these biological EFs by applying external direct current stimulation (DCS) is therefore the key to many new therapeutic strategies. During DCS, the charge transfer from electrode to tissue relies on a combination of reversible and irreversible electrochemical processes, which may generate toxic or bio-altering substances, including metal ions and reactive oxygen species (ROS). Poly(3,4-ethylenedioxythophene) (PEDOT) based electrodes are emerging as suitable candidates for DCS to improve the biocompatibility compared to metals. This work addresses whether PEDOT electrodes can be tailored to favor reversible biocompatible charge injection. To this end, different PEDOT formulations and their respective back electrodes are studied using cyclic voltammetry, chronopotentiometry, and direct measurements of H2O2 and O2. This combination of electrochemical methods sheds light on the time dynamics of reversible and irreversible charge transfer and the relationship between capacitance and ROS generation. The results presented here show that although all electrode materials investigated generate ROS, the onset of ROS can be delayed by increasing the electrode’s capacitance, which has implications for future bioelectronic devices that allow longer reversibly driven pulse durations during DCS.
- Open Access
On-chip brain slice stimulation: precise control of electric fields and tissue orientation
Non-invasive brain stimulation modalities, including transcranial direct current stimulation (tDCS), are widely used in neuroscience and clinical practice to modulate brain function and treat neuropsychiatric diseases. DC stimulation of ex vivo brain tissue slices has been a method used to understand mechanisms imparted by tDCS. However, delivering spatiotemporally uniform direct current electric fields (dcEFs) that have precisely engineered magnitudes and are also exempt from toxic electrochemical by-products are both significant limitations in conventional experimental setups. As a consequence, bioelectronic dose-response interrelations, the role of EF orientation, and the biomechanisms of prolonged or repeated stimulation over several days all remain not well understood. Here we developed a platform with fluidic, electrochemical, and magnetically-induced spatial control. Fluidically, the chamber geometrically confines precise dcEF delivery to the enclosed brain slice and allows for tissue recovery in order to monitor post-stimulation effects. Electrochemically, conducting hydrogel electrodes mitigate stimulation-induced faradaic reactions typical of commonly-used metal electrodes. Magnetically, we applied ferromagnetic substrates beneath the tissue and used an external permanent magnet to enable in situ rotational control in relation to the dcEF. By combining the microfluidic chamber with live-cell calcium imaging and electrophysiological recordings, we showcased the potential to study the acute and lasting effects of dcEFs with the potential of providing multi-session stimulation. This on-chip bioelectronic platform presents a modernized yet simple solution to electrically stimulate explanted tissue by offering more environmental control to users, which unlocks new opportunities to conduct thorough brain stimulation mechanistic investigations. Graphical
Open AccessOn-chip brain slice stimulation: precise control of electric fields and tissue orientation
Non-invasive brain stimulation modalities, including transcranial direct current stimulation (tDCS), are widely used in neuroscience and clinical practice to modulate brain function and treat neuropsychiatric diseases. DC stimulation of ex vivo brain tissue slices has been a method used to understand mechanisms imparted by tDCS. However, delivering spatiotemporally uniform direct current electric fields (dcEFs) that have precisely engineered magnitudes and are also exempt from toxic electrochemical by-products are both significant limitations in conventional experimental setups. As a consequence, bioelectronic dose-response interrelations, the role of EF orientation, and the biomechanisms of prolonged or repeated stimulation over several days all remain not well understood. Here we developed a platform with fluidic, electrochemical, and magnetically-induced spatial control. Fluidically, the chamber geometrically confines precise dcEF delivery to the enclosed brain slice and allows for tissue recovery in order to monitor post-stimulation effects. Electrochemically, conducting hydrogel electrodes mitigate stimulation-induced faradaic reactions typical of commonly-used metal electrodes. Magnetically, we applied ferromagnetic substrates beneath the tissue and used an external permanent magnet to enable in situ rotational control in relation to the dcEF. By combining the microfluidic chamber with live-cell calcium imaging and electrophysiological recordings, we showcased the potential to study the acute and lasting effects of dcEFs with the potential of providing multi-session stimulation. This on-chip bioelectronic platform presents a modernized yet simple solution to electrically stimulate explanted tissue by offering more environmental control to users, which unlocks new opportunities to conduct thorough brain stimulation mechanistic investigations. Graphical
- Open Access
Parting the cellular sea: electrotaxis evoked directional separation of co-cultured keratinocytes and fibroblasts
Bioelectric communication plays a significant role in several cellular processes and biological mechanisms, such as division, differentiation, migration, cancer metastasis, or wound healing. The flow of ions through cellular walls and the gradients generated thereby evoke this signaling as electric fields (EFs) form across membranes, and their changes act as cues for cells. An EF is natively generated towards the wound center during epithelial wound healing, aiming to align and guide cell migration, particularly of keratinocytes, fibroblasts, and macrophages. While this phenomenon, known as electrotaxis, has been extensively investigated across many cell types, it is typically explored one cell type at a time, which does not accurately represent cellular interactions during complex biological processes. Here we show the co-cultured electrotaxis of epithelial keratinocytes and fibroblasts with a salt-bridgeless microfluidic approach for the first time. The electrotactic response of these cells was first assessed in mono-culture to establish a baseline, resulting in a characteristic anodic migration for keratinocytes and cathodic for fibroblasts. Both cell types retained their electrotactic properties in co-culture leading to clear cellular partition. The methods leveraged herein can pave the way for future co-culture electrotaxis experiments where the concurrent influence of cell lines can be thoroughly investigated.
Open AccessParting the cellular sea: electrotaxis evoked directional separation of co-cultured keratinocytes and fibroblasts
Bioelectric communication plays a significant role in several cellular processes and biological mechanisms, such as division, differentiation, migration, cancer metastasis, or wound healing. The flow of ions through cellular walls and the gradients generated thereby evoke this signaling as electric fields (EFs) form across membranes, and their changes act as cues for cells. An EF is natively generated towards the wound center during epithelial wound healing, aiming to align and guide cell migration, particularly of keratinocytes, fibroblasts, and macrophages. While this phenomenon, known as electrotaxis, has been extensively investigated across many cell types, it is typically explored one cell type at a time, which does not accurately represent cellular interactions during complex biological processes. Here we show the co-cultured electrotaxis of epithelial keratinocytes and fibroblasts with a salt-bridgeless microfluidic approach for the first time. The electrotactic response of these cells was first assessed in mono-culture to establish a baseline, resulting in a characteristic anodic migration for keratinocytes and cathodic for fibroblasts. Both cell types retained their electrotactic properties in co-culture leading to clear cellular partition. The methods leveraged herein can pave the way for future co-culture electrotaxis experiments where the concurrent influence of cell lines can be thoroughly investigated.
- Open Access
- 12 February 2023
- Published by Wiley in Advanced Materials Interfaces
- Vol. 10 (8)
Guide to Leveraging Conducting Polymers and Hydrogels for Direct Current Stimulation
The tunable electrical properties of conducting polymers (CPs), their biocompatibility, fabrication versatility, and cost‐efficiency make them an ideal coating material for stimulation electrodes in biomedical applications. Several biological processes like wound healing, neuronal regrowth, and cancer metastasis, which rely on constant electric fields, demand electrodes capable of delivering direct current stimulation (DCs) for long times without developing toxic electrochemical reactions. Recently, CPs such as poly(3,4‐ethylenedioxythiophene) polystyrene sulfonate (PEDOT/PSS) have demonstrated outstanding capability for delivering DCs without damaging cells in culture while not requiring intermediate buffers, contrary to the current research setups relying on noble‐metals and buffering bridges. However, clear understanding of how electrode design and CP synthesis influence DCs properties of these materials has not been provided until now. This study demonstrates that various PEDOT‐based CP coatings and hydrogels on rough electrodes can deliver DCs without substantial changes to the electrode and the noticeable development of chemical by‐products depending on the electrode area and polymer thickness. A comprehensive analysis of the tested coatings is provided according to the desired application and available resources, alongside a proposed explanation for the observed electrochemical behavior. The CPs tested herein can pave the way toward the widespread implementation of DCs as a therapeutic stimulation paradigm.
- 12 February 2023
- Published by Wiley in Advanced Materials Interfaces
- Vol. 10 (8)
Open AccessGuide to Leveraging Conducting Polymers and Hydrogels for Direct Current Stimulation
The tunable electrical properties of conducting polymers (CPs), their biocompatibility, fabrication versatility, and cost‐efficiency make them an ideal coating material for stimulation electrodes in biomedical applications. Several biological processes like wound healing, neuronal regrowth, and cancer metastasis, which rely on constant electric fields, demand electrodes capable of delivering direct current stimulation (DCs) for long times without developing toxic electrochemical reactions. Recently, CPs such as poly(3,4‐ethylenedioxythiophene) polystyrene sulfonate (PEDOT/PSS) have demonstrated outstanding capability for delivering DCs without damaging cells in culture while not requiring intermediate buffers, contrary to the current research setups relying on noble‐metals and buffering bridges. However, clear understanding of how electrode design and CP synthesis influence DCs properties of these materials has not been provided until now. This study demonstrates that various PEDOT‐based CP coatings and hydrogels on rough electrodes can deliver DCs without substantial changes to the electrode and the noticeable development of chemical by‐products depending on the electrode area and polymer thickness. A comprehensive analysis of the tested coatings is provided according to the desired application and available resources, alongside a proposed explanation for the observed electrochemical behavior. The CPs tested herein can pave the way toward the widespread implementation of DCs as a therapeutic stimulation paradigm.
- Open Access
- 18 January 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (6) , 1531-1546
Bioelectronic microfluidic wound healing: a platform for investigating direct current stimulation of injured cell collectives
An on-chip bioelectronic platform for exploring precise direct current electric field stimulation of injured keratinocytes with salt-bridgeless electrodes.
- 18 January 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (6) , 1531-1546
Open AccessBioelectronic microfluidic wound healing: a platform for investigating direct current stimulation of injured cell collectives
An on-chip bioelectronic platform for exploring precise direct current electric field stimulation of injured keratinocytes with salt-bridgeless electrodes.
- Open Access
- 5 December 2022
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 385, 109761
A microfluidic perspective on conventional in vitro transcranial direct current stimulation methods
- 5 December 2022
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 385, 109761
Open AccessA microfluidic perspective on conventional in vitro transcranial direct current stimulation methods
- Open Access
Bioelectronic microfluidic wound healing
This work delves into the impact of direct current (DC) stimulation on both healthy and diabetic in vitro wound healing models of keratinocytes, the most prevalent cell type of the skin. The augmentation of non-metal electrode materials and prudent microfluidic design allowed for a platform to study the effects of different sustained (12 hours DC) electric field configurations on wound closure dynamics. We found that electric guidance cues (≃ 200mVmm −1 ) enhance wound closure rate by nearly 3X for both healthy and diabetic-like keratinocyte sheets, compared to their respective controls. The motility-inhibited keratinocytes regained wound closure rates with stimulation (increase from 1.0 to 2.8% hr −1 ) comparable to healthy non-stimulated keratinocyte collectives (3.5% hr −1 ). Our results bring hope that electrical stimulation is a viable pathway to accelerate wound repair.
Open AccessBioelectronic microfluidic wound healing
This work delves into the impact of direct current (DC) stimulation on both healthy and diabetic in vitro wound healing models of keratinocytes, the most prevalent cell type of the skin. The augmentation of non-metal electrode materials and prudent microfluidic design allowed for a platform to study the effects of different sustained (12 hours DC) electric field configurations on wound closure dynamics. We found that electric guidance cues (≃ 200mVmm −1 ) enhance wound closure rate by nearly 3X for both healthy and diabetic-like keratinocyte sheets, compared to their respective controls. The motility-inhibited keratinocytes regained wound closure rates with stimulation (increase from 1.0 to 2.8% hr −1 ) comparable to healthy non-stimulated keratinocyte collectives (3.5% hr −1 ). Our results bring hope that electrical stimulation is a viable pathway to accelerate wound repair.
- Open Access
- 13 April 2022
- Published by Elsevier in Biosensors and Bioelectronics: X
- Vol. 11
Skin stimulation and recording: Moving towards metal-free electrodes
- 13 April 2022
- Published by Elsevier in Biosensors and Bioelectronics: X
- Vol. 11
Open AccessSkin stimulation and recording: Moving towards metal-free electrodes