Alok K. Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alok K. Singh has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Vasant Natarajan
4 shared publications- Vasant Natarajan
Department of Physics, Indian Institute of Science, Indian Institute of Science, Bangalore, Karnataka, 560012, INDIA
4 shared publications Kanhaiya Pandey
Physics, Indian Institute of Technology Guwahati, Department of Physics, Kanhaiya Pandey, Guwahati, 781039, INDIA
3 shared publicationsK. D. Rathod
2 shared publicationsMarkus Gellesch
School of Physics and Astronomy, University of Birmingham, Birmingham, UK
2 shared publicationsAtanu K. Mohanty
Supercomputer Education and Research Centre, Indian Institute of Science, Bangalore 560 012, India
1 shared publication
Latest Publications
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
An Optical Lattice Clock Testbed System for the iqClock Project Demonstrator
We present our work on a compact and flexible Optical Lattice Clock Testbed System. This system helps realizing a compact and transportable strontium-based optical atomic clock demonstrator built from industry-developed subsystems – a deliverable of the iqClock project. The demonstrator will be integrated at the University of Birmingham. In order to facilitate the system integration of the demonstrator, we use the testbed system to assess the performance of the industry-built components and subsystems. The testbed is completed in its first phase, capable of realizing ultra-cold atoms. In a subsequent phase, we will transform the testbed system into a strontium-based frequency standard.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
An Optical Lattice Clock Testbed System for the iqClock Project Demonstrator
We present our work on a compact and flexible Optical Lattice Clock Testbed System. This system helps realizing a compact and transportable strontium-based optical atomic clock demonstrator built from industry-developed subsystems – a deliverable of the iqClock project. The demonstrator will be integrated at the University of Birmingham. In order to facilitate the system integration of the demonstrator, we use the testbed system to assess the performance of the industry-built components and subsystems. The testbed is completed in its first phase, capable of realizing ultra-cold atoms. In a subsequent phase, we will transform the testbed system into a strontium-based frequency standard.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Development of a Portable Optical Clock
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Development of a Portable Optical Clock
- 8 January 2018
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 51 (3) , 035502
Study of CPO resonances on the intercombination line in 173 Yb
We study coherent population oscillations in an odd isotope of the two-electron atom Yb. The experiments are done using magnetic sublevels of the F g = 5 / 2 → F e = 3 / 2 hyperfine transition in 173 Yb of the 1 S 0 → 3 P 1 intercombination line. The experiments are done both with and without an applied magnetic field. In the absence of an applied field, the complicated sublevel structure along with the saturated fluorescence effect causes the linewidth to be larger than the 190 kHz natural linewidth of the transition. In the presence of a field (of magnitude 330 mG), a well-defined quantization axis is present which results in the formation of two M-type systems. The total fluorescence is then limited by spin coherence among the ground sublevels. In addition, the pump beam gets detuned from resonance which results in a reduced scattering rate from the 3 P 1 state. Both of these effects result in a reduction of the linewidth to a subnatural value of about 100 kHz.
- 8 January 2018
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 51 (3) , 035502
Study of CPO resonances on the intercombination line in 173 Yb
We study coherent population oscillations in an odd isotope of the two-electron atom Yb. The experiments are done using magnetic sublevels of the F g = 5 / 2 → F e = 3 / 2 hyperfine transition in 173 Yb of the 1 S 0 → 3 P 1 intercombination line. The experiments are done both with and without an applied magnetic field. In the absence of an applied field, the complicated sublevel structure along with the saturated fluorescence effect causes the linewidth to be larger than the 190 kHz natural linewidth of the transition. In the presence of a field (of magnitude 330 mG), a well-defined quantization axis is present which results in the formation of two M-type systems. The total fluorescence is then limited by spin coherence among the ground sublevels. In addition, the pump beam gets detuned from resonance which results in a reduced scattering rate from the 3 P 1 state. Both of these effects result in a reduction of the linewidth to a subnatural value of about 100 kHz.
- Open Access
- 1 March 2015
- Published by IOP Publishing in New Journal of Physics
- Vol. 17 (3)
Observation of coherent population trapping in a V-type two-electron system
- 1 March 2015
- Published by IOP Publishing in New Journal of Physics
- Vol. 17 (3)
Open AccessObservation of coherent population trapping in a V-type two-electron system
- 1 May 2013
- Published by Oxford University Press (OUP) in Europhysics Letters
- Vol. 102 (4)
Continuous beam of laser-cooled Yb atoms
- 1 May 2013
- Published by Oxford University Press (OUP) in Europhysics Letters
- Vol. 102 (4)
Continuous beam of laser-cooled Yb atoms
- 31 January 2013
- Published by American Physical Society (APS) in Physical Review A
- Vol. 87 (1)
Observation of the nuclear magnetic octupole moment ofYb from precise measurements of the hyperfine structure in thestateWe measure hyperfine structure in the metastable state of Yb and extract the nuclear magnetic octupole moment. We populate the state using dipole-allowed transitions through the and states. We measure frequencies of hyperfine transitions of the line at 770 nm using a Rb-stabilized ring cavity resonator with a precision of 200 kHz. Second-order corrections due to perturbations from the nearby and states are below 30 kHz. We obtain the hyperfine coefficients as MHz and MHz, which represent a two orders-of-magnitude improvement in precision, and MHz. From atomic structure calculations, we obtain the nuclear moments quadrupole b and octupole . DOI: http://dx.doi.org/10.1103/PhysRevA.87.012512 ©2013 American Physical Society- 31 January 2013
- Published by American Physical Society (APS) in Physical Review A
- Vol. 87 (1)
Observation of the nuclear magnetic octupole moment ofYb from precise measurements of the hyperfine structure in thestateWe measure hyperfine structure in the metastable state of Yb and extract the nuclear magnetic octupole moment. We populate the state using dipole-allowed transitions through the and states. We measure frequencies of hyperfine transitions of the line at 770 nm using a Rb-stabilized ring cavity resonator with a precision of 200 kHz. Second-order corrections due to perturbations from the nearby and states are below 30 kHz. We obtain the hyperfine coefficients as MHz and MHz, which represent a two orders-of-magnitude improvement in precision, and MHz. From atomic structure calculations, we obtain the nuclear moments quadrupole b and octupole . DOI: http://dx.doi.org/10.1103/PhysRevA.87.012512 ©2013 American Physical Society- 12 September 2012
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 29 (10) , 2734-2740
Optical frequency metrology with an Rb-stabilized ring-cavity resonator—study of cavity-dispersion errors
We have developed a technique to measure the absolute frequencies of optical transitions by using an evacuated Rb-stabilized ring-cavity resonator as a transfer cavity. The absolute frequency of the Rb line (at 780 nm) used to stabilize the cavity is known and allows us to determine the absolute value of the unknown frequency. We study wavelength-dependent errors due to dispersion at the cavity mirrors by measuring the frequency of the same transition in the Cs line (at 852 nm) at three cavity lengths. The spread in the values shows that dispersion errors are below 30 kHz, corresponding to a relative precision of . We give an explanation for reduced dispersion errors in the ring-cavity geometry by calculating errors due to the lateral shift and the phase shift at the mirrors, and show that they are roughly equal but occur with opposite signs. We have earlier shown that diffraction errors (due to Guoy phase) are negligible in the ring-cavity geometry compared to a linear cavity; the reduced dispersion error is another advantage. Our values are consistent with measurements of the same transition using the more expensive frequency-comb technique. Our simpler method is ideally suited for measuring hyperfine structure, fine structure, and isotope shifts, up to several hundreds of gigahertz.- 12 September 2012
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 29 (10) , 2734-2740
Optical frequency metrology with an Rb-stabilized ring-cavity resonator—study of cavity-dispersion errors
We have developed a technique to measure the absolute frequencies of optical transitions by using an evacuated Rb-stabilized ring-cavity resonator as a transfer cavity. The absolute frequency of the Rb line (at 780 nm) used to stabilize the cavity is known and allows us to determine the absolute value of the unknown frequency. We study wavelength-dependent errors due to dispersion at the cavity mirrors by measuring the frequency of the same transition in the Cs line (at 852 nm) at three cavity lengths. The spread in the values shows that dispersion errors are below 30 kHz, corresponding to a relative precision of . We give an explanation for reduced dispersion errors in the ring-cavity geometry by calculating errors due to the lateral shift and the phase shift at the mirrors, and show that they are roughly equal but occur with opposite signs. We have earlier shown that diffraction errors (due to Guoy phase) are negligible in the ring-cavity geometry compared to a linear cavity; the reduced dispersion error is another advantage. Our values are consistent with measurements of the same transition using the more expensive frequency-comb technique. Our simpler method is ideally suited for measuring hyperfine structure, fine structure, and isotope shifts, up to several hundreds of gigahertz.- 1 September 2011
- Published by Elsevier in Optics Communications
- Vol. 284 (20) , 4957-4960
Subnatural linewidth in a strongly-driven degenerate two-level system
- 1 September 2011
- Published by Elsevier in Optics Communications
- Vol. 284 (20) , 4957-4960
Subnatural linewidth in a strongly-driven degenerate two-level system
- 25 October 2010
- Published by American Physical Society (APS) in Physical Review A
- Vol. 82 (4)
Atomic fountain of laser-cooled Yb atoms for precision measurements
We demonstrate launching of laser-cooled Yb atoms in a cold atomic fountain. Atoms in a collimated thermal beam are first cooled and captured in a magneto-optical trap (MOT) operating on the strongly allowed transition at 399 nm (blue line). They are then transferred to a MOT on the weakly allowed transition at 556 nm (green line). Cold atoms from the green MOT are launched against gravity at a velocity of around 2.5 m/s using a pair of green beams. We trap more than atoms in the blue MOT and transfer up to into the green MOT. The temperature for the odd isotope is in the blue MOT, and reduces by a factor of 40 in the green MOT. DOI: http://dx.doi.org/10.1103/PhysRevA.82.043429 © 2010 The American Physical Society- 25 October 2010
- Published by American Physical Society (APS) in Physical Review A
- Vol. 82 (4)
Atomic fountain of laser-cooled Yb atoms for precision measurements
We demonstrate launching of laser-cooled Yb atoms in a cold atomic fountain. Atoms in a collimated thermal beam are first cooled and captured in a magneto-optical trap (MOT) operating on the strongly allowed transition at 399 nm (blue line). They are then transferred to a MOT on the weakly allowed transition at 556 nm (green line). Cold atoms from the green MOT are launched against gravity at a velocity of around 2.5 m/s using a pair of green beams. We trap more than atoms in the blue MOT and transfer up to into the green MOT. The temperature for the odd isotope is in the blue MOT, and reduces by a factor of 40 in the green MOT. DOI: http://dx.doi.org/10.1103/PhysRevA.82.043429 © 2010 The American Physical Society- 31 August 2009
- Published by American Physical Society (APS) in Physical Review A
- Vol. 80 (2) , 022518
Isotope shifts and hyperfine structure in the 555.8-nmline of YbWe apply our technique of using a Rb-stabilized ring-cavity resonator to measure the frequencies of various spectral components in the 555.8-nm line of Yb. We determine the isotope shifts with 60 kHz precision, which is an order-of-magnitude improvement over the best previous measurement on this line. There are two overlapping transitions, and , which we resolve by applying a magnetic field. We thus obtain the hyperfine constants in the state of the odd isotopes with a significantly improved precision. Knowledge of isotope shifts and hyperfine structure should prove useful for high-precision calculations in Yb necessary to interpret ongoing experiments testing parity and time-reversal symmetry violation in the laws of physics.- 31 August 2009
- Published by American Physical Society (APS) in Physical Review A
- Vol. 80 (2) , 022518
Isotope shifts and hyperfine structure in the 555.8-nmline of YbWe apply our technique of using a Rb-stabilized ring-cavity resonator to measure the frequencies of various spectral components in the 555.8-nm line of Yb. We determine the isotope shifts with 60 kHz precision, which is an order-of-magnitude improvement over the best previous measurement on this line. There are two overlapping transitions, and , which we resolve by applying a magnetic field. We thus obtain the hyperfine constants in the state of the odd isotopes with a significantly improved precision. Knowledge of isotope shifts and hyperfine structure should prove useful for high-precision calculations in Yb necessary to interpret ongoing experiments testing parity and time-reversal symmetry violation in the laws of physics.