Amine Lilane
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Amine Lilane has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Dennoun Saifaoui
Laboratory of Renewable Energies and Dynamics of Systems, Faculty of Science Ain Chock, Hassan II University, Casablanca, Morocco
4 shared publications - Ahmed Ghadhy
Renewable Energies and Systems Dynamics Laboratory, Faculty of Sciences Aîn Chock, Hassan II University, El-Jadida Road Km9, Maarif, Casablanca P.O. Box 5366, Morocco
2 shared publications D. Saifaoui
2 shared publicationsH. Jenkal
2 shared publications- Hicham Karmouni
National School of Applied Sciences, Cadi Ayyad University, Marrakech, Morocco
2 shared publications - Karim Benkirane
Laboratory of Renewable Energies and Dynamics of Systems, Royal Navy School, Hassan II University, Casablanca, Morocco
2 shared publications
Latest Publications
- Open Access
Performance Analysis of Seawater Desalination Using Reverse Osmosis and Energy Recovery Devices in Nouadhibou
Arid zones, such as the MENA regions and the Sahara countries, are experiencing significant water stress. To address this global challenge, desalination technologies provide a crucial solution, particularly the reverse osmosis (RO) technique, which is widely used to treat Seawater or Brackish water. Mauritania is among the countries facing a scarcity of potable water resources and relies on desalination technologies to meet its water demand. In this work, a numerical and experimental study was carried out on the functional and productive parameters of the Nouadhibou desalination plant in Mauritania using MATLAB/Simulink (R2016a). The study considered two operating scenarios: with and without the energy recovery unit. The objective of this paper is to perform an analytical study of the operating procedures of the Nouadhibou RO desalination plant by varying several parameters, such as the pressure exchanger, and the feed water mixing ratio in the pressure exchanger unit, etc., in order to determine the system’s optimal operating point. This paper analyzes the system’s performance under different conditions, including recovery rate, feed water temperature, and PEX splitter ratio. In Case No. 1 (without a pressure recovery unit), and with a recovery rate of 20%, doubling the plant’s productivity from 400 to 800 m3/d requires 400 kW of power. In contrast, in Case No. 2 (with a pressure recovery unit), achieving the same productivity requires only 100 kW, with a 75% of energy saving. When the desalination plant operates at a productivity of 400 m3/d@40%, the SPC decreases from 6 kWh/m3 (Case No. 1) to 2.7 kWh/m3 (Case No. 2), resulting in a 55% specific power consumption saving. The results also indicate that power consumption increases with both feed water temperature and PEX splitter ratio, while variations in these parameters have a negligible effect on permeate salinity.
Open AccessPerformance Analysis of Seawater Desalination Using Reverse Osmosis and Energy Recovery Devices in Nouadhibou
Arid zones, such as the MENA regions and the Sahara countries, are experiencing significant water stress. To address this global challenge, desalination technologies provide a crucial solution, particularly the reverse osmosis (RO) technique, which is widely used to treat Seawater or Brackish water. Mauritania is among the countries facing a scarcity of potable water resources and relies on desalination technologies to meet its water demand. In this work, a numerical and experimental study was carried out on the functional and productive parameters of the Nouadhibou desalination plant in Mauritania using MATLAB/Simulink (R2016a). The study considered two operating scenarios: with and without the energy recovery unit. The objective of this paper is to perform an analytical study of the operating procedures of the Nouadhibou RO desalination plant by varying several parameters, such as the pressure exchanger, and the feed water mixing ratio in the pressure exchanger unit, etc., in order to determine the system’s optimal operating point. This paper analyzes the system’s performance under different conditions, including recovery rate, feed water temperature, and PEX splitter ratio. In Case No. 1 (without a pressure recovery unit), and with a recovery rate of 20%, doubling the plant’s productivity from 400 to 800 m3/d requires 400 kW of power. In contrast, in Case No. 2 (with a pressure recovery unit), achieving the same productivity requires only 100 kW, with a 75% of energy saving. When the desalination plant operates at a productivity of 400 m3/d@40%, the SPC decreases from 6 kWh/m3 (Case No. 1) to 2.7 kWh/m3 (Case No. 2), resulting in a 55% specific power consumption saving. The results also indicate that power consumption increases with both feed water temperature and PEX splitter ratio, while variations in these parameters have a negligible effect on permeate salinity.
- 25 April 2025
- Published by Springer Nature in Energy Systems
- Vol. 17 (4) , 1-19
MPPT control based on the H-ABC-P&O hybrid algorithm for a photovoltaic pumping system: a case study in Casablanca
- 25 April 2025
- Published by Springer Nature in Energy Systems
- Vol. 17 (4) , 1-19
MPPT control based on the H-ABC-P&O hybrid algorithm for a photovoltaic pumping system: a case study in Casablanca
- Open Access
- 25 December 2024
- Published by Universal Wiser Publisher Pte. Ltd in Engineering Science & Technology
- p. 99-119
The Numerical Simulation and Performance Analysis of Seawater Desalination Unit: The Case of SWRO Station with Energy Recovery Devices (ERDs)
The demand for good quality drinking water is experiencing strong growth on a global scale, particularly in emerging countries, such as the BASIC countries (Brazil, South Africa, India, and China). For this reason, sea or brackish water desalination technology using membrane filtration technique is a very effective and sustainable method for dealing with this problem. In this work, the performance study of the reverse osmosis desalination plant of Nouadhibou-Mauritania coupled or not to an energy recovery unit was carried out using the Matlab/Simulink software. The objective of this work is to study the functional and productive performance of the reverse osmosis unit by examining the importance of the pressure exchanger in such systems, by acting on the mixing rate of feed water with the flow of water delivered by the pressure exchanger. This study shows that the exploited Energy Recovery devices (ERDs) have a very favorable economic and energetic profitability of 75% reduction, which reduces the specific power consumption by 5 instead of 14.5 kWh/m3 in the case of a system without and with the ERDs, for productivity of 800 m3/d and a recovery rate of 20%.
- 25 December 2024
- Published by Universal Wiser Publisher Pte. Ltd in Engineering Science & Technology
- p. 99-119
Open AccessThe Numerical Simulation and Performance Analysis of Seawater Desalination Unit: The Case of SWRO Station with Energy Recovery Devices (ERDs)
The demand for good quality drinking water is experiencing strong growth on a global scale, particularly in emerging countries, such as the BASIC countries (Brazil, South Africa, India, and China). For this reason, sea or brackish water desalination technology using membrane filtration technique is a very effective and sustainable method for dealing with this problem. In this work, the performance study of the reverse osmosis desalination plant of Nouadhibou-Mauritania coupled or not to an energy recovery unit was carried out using the Matlab/Simulink software. The objective of this work is to study the functional and productive performance of the reverse osmosis unit by examining the importance of the pressure exchanger in such systems, by acting on the mixing rate of feed water with the flow of water delivered by the pressure exchanger. This study shows that the exploited Energy Recovery devices (ERDs) have a very favorable economic and energetic profitability of 75% reduction, which reduces the specific power consumption by 5 instead of 14.5 kWh/m3 in the case of a system without and with the ERDs, for productivity of 800 m3/d and a recovery rate of 20%.
- 12 April 2022
- Published by Springer Nature in Technology and Economics of Smart Grids and Sustainable Energy
- Vol. 7 (1) , 1-16
Control of a Photovoltaic Pumping System Using the ABC Algorithm in EL Jadida Climate
- 12 April 2022
- Published by Springer Nature in Technology and Economics of Smart Grids and Sustainable Energy
- Vol. 7 (1) , 1-16
Control of a Photovoltaic Pumping System Using the ABC Algorithm in EL Jadida Climate
- Open Access
- 1 September 2021
- Published by Elsevier in Desalination and Water Treatment
- Vol. 235, 26-38
Exergetic and thermo-economic analysis of different multi-effect configurations powered by solar power plants
- 1 September 2021
- Published by Elsevier in Desalination and Water Treatment
- Vol. 235, 26-38
Open AccessExergetic and thermo-economic analysis of different multi-effect configurations powered by solar power plants
- 1 January 2020
- Published by Elsevier in Materials Today: Proceedings
- Vol. 24, 42-45
Study of the currentology of Moroccan facades and assessment of the marine energy potential for the fight against the impact of climate changes
- 1 January 2020
- Published by Elsevier in Materials Today: Proceedings
- Vol. 24, 42-45
Study of the currentology of Moroccan facades and assessment of the marine energy potential for the fight against the impact of climate changes
- 1 January 2020
- Published by Elsevier in Materials Today: Proceedings
- Vol. 24, 114-118
Modeling and simulation of the performances of the reverse osmosis membrane
- 1 January 2020
- Published by Elsevier in Materials Today: Proceedings
- Vol. 24, 114-118
Modeling and simulation of the performances of the reverse osmosis membrane