Søren Helbo Skaarup
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Søren Helbo Skaarup has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Aage Kristian Olsen Alstrup
Department of Nuclear Medicine, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200 Aarhus, Denmark
1 shared publication - Allan Bach
Prehospital Emergency Medical Services, Central Denmark Region, Aarhus N, Denmark
1 shared publication - Anne Heltborg
Department of Emergency Medicine, University Hospital of Southern Denmark, 6200 Aabenraa, Denmark
1 shared publication - Camilla Stræde Spile
Department of Radiology, Odense University Hospital, 5000 Odense, Denmark
1 shared publication - Casper Falster
Odense Respiratory Research Unit (ODIN), Department of Clinical Research, University of Southern Denmark, Odense University Hospital, 5000 Odense, Denmark
1 shared publication - Christian Backer Mogensen
Department of Emergency Medicine, University hospital of Southern Denmark, Aabenraa, Denmark
1 shared publication
Latest Publications
- Open Access
- 28 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (17) , 2759
Diaphragmatic Ultrasound in Fibrosing Interstitial Lung Disease: A Systematic Review of Current Evidence
Background/Objectives: Fibrosing interstitial lung disease (F-ILD) is associated with progressive respiratory impairment and substantial symptom burden. Diaphragmatic ultrasound (DUS) is a non-invasive method for assessing diaphragmatic structure and function, but its clinical role in F-ILD remains uncertain. This systematic review evaluated the available evidence on DUS in adults with F-ILD. Methods: This systematic review was conducted and reported according to the PRISMA guidelines. MEDLINE, Embase, CINAHL, and the Cochrane Library were searched and observational studies evaluating DUS in adults with F-ILD were included. Risk of bias was assessed using the QUADAS-2, and outcome-level certainty of evidence was evaluated by GRADE framework. Results: Six cross-sectional observational studies involving 232 participants were included. Diaphragmatic excursion (DE) was assessed in all six studies, while diaphragm thickness (DT) and thickening fraction (TF) were evaluated in four. Some studies reported abnormalities in DUS parameters during deep breathing and cross-sectional associations with pulmonary function, exercise capacity, dyspnoea, or radiological severity. Substantial heterogeneity in study populations, ultrasound protocols, and outcome reporting precluded meta-analysis. The certainty of evidence was very low. Conclusions: Current evidence suggests that DUS may detect diaphragmatic abnormalities in patients with F-ILD and may have future complementary value alongside established clinical assessments. However, the evidence is limited, heterogeneous, and of very low certainty and does not establish diagnostic accuracy, prognostic value, or usefulness for longitudinal monitoring. Accordingly, DUS cannot currently be recommended for routine clinical implementation in F-ILD, and prospective longitudinal validation is required.
- 28 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (17) , 2759
Open AccessDiaphragmatic Ultrasound in Fibrosing Interstitial Lung Disease: A Systematic Review of Current Evidence
Background/Objectives: Fibrosing interstitial lung disease (F-ILD) is associated with progressive respiratory impairment and substantial symptom burden. Diaphragmatic ultrasound (DUS) is a non-invasive method for assessing diaphragmatic structure and function, but its clinical role in F-ILD remains uncertain. This systematic review evaluated the available evidence on DUS in adults with F-ILD. Methods: This systematic review was conducted and reported according to the PRISMA guidelines. MEDLINE, Embase, CINAHL, and the Cochrane Library were searched and observational studies evaluating DUS in adults with F-ILD were included. Risk of bias was assessed using the QUADAS-2, and outcome-level certainty of evidence was evaluated by GRADE framework. Results: Six cross-sectional observational studies involving 232 participants were included. Diaphragmatic excursion (DE) was assessed in all six studies, while diaphragm thickness (DT) and thickening fraction (TF) were evaluated in four. Some studies reported abnormalities in DUS parameters during deep breathing and cross-sectional associations with pulmonary function, exercise capacity, dyspnoea, or radiological severity. Substantial heterogeneity in study populations, ultrasound protocols, and outcome reporting precluded meta-analysis. The certainty of evidence was very low. Conclusions: Current evidence suggests that DUS may detect diaphragmatic abnormalities in patients with F-ILD and may have future complementary value alongside established clinical assessments. However, the evidence is limited, heterogeneous, and of very low certainty and does not establish diagnostic accuracy, prognostic value, or usefulness for longitudinal monitoring. Accordingly, DUS cannot currently be recommended for routine clinical implementation in F-ILD, and prospective longitudinal validation is required.
- Open Access
- 30 August 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (17) , 1921
Handheld Ultrasound Devices Used by Newly Certified Operators for Pneumonia in the Emergency Department—A Diagnostic Accuracy Study
The diagnostic accuracy of handheld ultrasound (HHUS) devices operated by newly certified operators for pneumonia is unknown. This multicenter diagnostic accuracy study included patients prospectively suspected of pneumonia from February 2021 to February 2022 in four emergency departments. The index test was a 14-zone focused lung ultrasound (FLUS) examination, with consolidation with air bronchograms as diagnostic criteria for pneumonia. FLUS examinations were performed by newly certified operators using HHUS. The reference standard was computed tomography (CT) and expert diagnosis using all medical records. The sensitivity and specificity of FLUS and chest X-ray (CXR) were compared using McNemar’s test. Of the 324 scanned patients, 212 (65%) had pneumonia, according to the expert diagnosis. FLUS had a sensitivity of 31% (95% CI 26–36) and a specificity of 82% (95% CI 78–86) compared with the experts’ diagnosis. Compared with CT, FLUS had a sensitivity of 32% (95% CI 27–37) and specificity of 81% (95% CI 77–85). CXR had a sensitivity of 66% (95% CI 61–72) and a specificity of 76% (95% CI 71–81) compared with the experts’ diagnosis. Compared with CT, CXR had a sensitivity of 69% (95% CI 63–74) and a specificity of 68% (95% CI 62–72). Compared with the experts’ diagnosis and CT diagnosis, FLUS performed by newly certified operators using HHUS devices had a significantly lower sensitivity for pneumonia when compared to CXR (p < 0.001). FLUS had a significantly higher specificity than CXR using CT diagnosis as a reference standard (p = 0.02). HHUS exhibited low sensitivity for pneumonia when used by newly certified operators.
- 30 August 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (17) , 1921
Open AccessHandheld Ultrasound Devices Used by Newly Certified Operators for Pneumonia in the Emergency Department—A Diagnostic Accuracy Study
The diagnostic accuracy of handheld ultrasound (HHUS) devices operated by newly certified operators for pneumonia is unknown. This multicenter diagnostic accuracy study included patients prospectively suspected of pneumonia from February 2021 to February 2022 in four emergency departments. The index test was a 14-zone focused lung ultrasound (FLUS) examination, with consolidation with air bronchograms as diagnostic criteria for pneumonia. FLUS examinations were performed by newly certified operators using HHUS. The reference standard was computed tomography (CT) and expert diagnosis using all medical records. The sensitivity and specificity of FLUS and chest X-ray (CXR) were compared using McNemar’s test. Of the 324 scanned patients, 212 (65%) had pneumonia, according to the expert diagnosis. FLUS had a sensitivity of 31% (95% CI 26–36) and a specificity of 82% (95% CI 78–86) compared with the experts’ diagnosis. Compared with CT, FLUS had a sensitivity of 32% (95% CI 27–37) and specificity of 81% (95% CI 77–85). CXR had a sensitivity of 66% (95% CI 61–72) and a specificity of 76% (95% CI 71–81) compared with the experts’ diagnosis. Compared with CT, CXR had a sensitivity of 69% (95% CI 63–74) and a specificity of 68% (95% CI 62–72). Compared with the experts’ diagnosis and CT diagnosis, FLUS performed by newly certified operators using HHUS devices had a significantly lower sensitivity for pneumonia when compared to CXR (p < 0.001). FLUS had a significantly higher specificity than CXR using CT diagnosis as a reference standard (p = 0.02). HHUS exhibited low sensitivity for pneumonia when used by newly certified operators.
- Open Access
- 31 March 2022
- Published by Springer Nature in BMC Emergency Medicine
- Vol. 22 (1) , 1-7
Implementation and findings on a one-minute sit-stand test for prehospital triage in patients with suspected COVID-19—a pilot project
During the initial Coronavirus Disease 2019 (COVID-19) pandemic wave, sparse personal protection equipment made telephone triage of suscpeted COVID-19 patients for ambulance transport necessary. To spare resources, stable patients were often treated and released on-scene, but reports from Italy suggested that some later detoriated. We implemented a prehospital sit-stand test to identify patients in risk for detoriation. The test was implemented as part of a new guideline in stable suspected COVID-19 patients younger than 70 years with no risk factors for serious disease triaged by general practitioners to ambulance response in the Central Denmark Region. Data were collected from April 6th to July 6th 2020. The primary outcome for this study was the proportion of patients treated with oxygen within 7 days among patients decompensating vs patients not decompensating during the test. Data on 156 patients triaged to ambulance response by general practioners were analysed. In total 86/156 (55%) were tested with the sit-stand test. Due to off-guideline use of the test, 30/86 (34.8%) were either older than 70 or had risk factors for serious disease. 10/156 (6%) of patients had a positive COVID-19-test. In total, 17/86 (20%) decompensated during the test and of these, 9/17 (53%) were treated with oxygen compared to 2/69 (3%) in patients who did not decompensate (p < 0.001). In a population suspected of COVID-19 but with a low COVD-19 prevalence, decompensation with the sit-stand test was observed in 20% of patients and was associated with oxygen treatment within 7 days. These findings are hypotheses-generating and suggest that physical exercise testing may be usefull for decision making in emergency settings.
- 31 March 2022
- Published by Springer Nature in BMC Emergency Medicine
- Vol. 22 (1) , 1-7
Open AccessImplementation and findings on a one-minute sit-stand test for prehospital triage in patients with suspected COVID-19—a pilot project
During the initial Coronavirus Disease 2019 (COVID-19) pandemic wave, sparse personal protection equipment made telephone triage of suscpeted COVID-19 patients for ambulance transport necessary. To spare resources, stable patients were often treated and released on-scene, but reports from Italy suggested that some later detoriated. We implemented a prehospital sit-stand test to identify patients in risk for detoriation. The test was implemented as part of a new guideline in stable suspected COVID-19 patients younger than 70 years with no risk factors for serious disease triaged by general practitioners to ambulance response in the Central Denmark Region. Data were collected from April 6th to July 6th 2020. The primary outcome for this study was the proportion of patients treated with oxygen within 7 days among patients decompensating vs patients not decompensating during the test. Data on 156 patients triaged to ambulance response by general practioners were analysed. In total 86/156 (55%) were tested with the sit-stand test. Due to off-guideline use of the test, 30/86 (34.8%) were either older than 70 or had risk factors for serious disease. 10/156 (6%) of patients had a positive COVID-19-test. In total, 17/86 (20%) decompensated during the test and of these, 9/17 (53%) were treated with oxygen compared to 2/69 (3%) in patients who did not decompensate (p < 0.001). In a population suspected of COVID-19 but with a low COVD-19 prevalence, decompensation with the sit-stand test was observed in 20% of patients and was associated with oxygen treatment within 7 days. These findings are hypotheses-generating and suggest that physical exercise testing may be usefull for decision making in emergency settings.
- Open Access
The CRISPR/Cas9 Minipig—A Transgenic Minipig to Produce Specific Mutations in Designated Tissues
The generation of large transgenic animals is impeded by complex cloning, long maturation and gastrulation times. An introduction of multiple gene alterations increases the complexity. We have cloned a transgenic Cas9 minipig to introduce multiple mutations by CRISPR in somatic cells. Transgenic Cas9 pigs were generated by somatic cell nuclear transfer and were backcrossed to Göttingen Minipigs for two generations. Cas9 expression was controlled by FlpO-mediated recombination and was visualized by translation from red to yellow fluorescent protein. In vitro analyses in primary fibroblasts, keratinocytes and lung epithelial cells confirmed the genetic alterations executed by the viral delivery of single guide RNAs (sgRNA) to the target cells. Moreover, multiple gene alterations could be introduced simultaneously in a cell by viral delivery of sgRNAs. Cells with loss of TP53, PTEN and gain-of-function mutation in KRASG12D showed increased proliferation, confirming a transformation of the primary cells. An in vivo activation of Cas9 expression could be induced by viral delivery to the skin. Overall, we have generated a minipig with conditional expression of Cas9, where multiple gene alterations can be introduced to somatic cells by viral delivery of sgRNA. The development of a transgenic Cas9 minipig facilitates the creation of complex pre-clinical models for cancer research.
Open AccessThe CRISPR/Cas9 Minipig—A Transgenic Minipig to Produce Specific Mutations in Designated Tissues
The generation of large transgenic animals is impeded by complex cloning, long maturation and gastrulation times. An introduction of multiple gene alterations increases the complexity. We have cloned a transgenic Cas9 minipig to introduce multiple mutations by CRISPR in somatic cells. Transgenic Cas9 pigs were generated by somatic cell nuclear transfer and were backcrossed to Göttingen Minipigs for two generations. Cas9 expression was controlled by FlpO-mediated recombination and was visualized by translation from red to yellow fluorescent protein. In vitro analyses in primary fibroblasts, keratinocytes and lung epithelial cells confirmed the genetic alterations executed by the viral delivery of single guide RNAs (sgRNA) to the target cells. Moreover, multiple gene alterations could be introduced simultaneously in a cell by viral delivery of sgRNAs. Cells with loss of TP53, PTEN and gain-of-function mutation in KRASG12D showed increased proliferation, confirming a transformation of the primary cells. An in vivo activation of Cas9 expression could be induced by viral delivery to the skin. Overall, we have generated a minipig with conditional expression of Cas9, where multiple gene alterations can be introduced to somatic cells by viral delivery of sgRNA. The development of a transgenic Cas9 minipig facilitates the creation of complex pre-clinical models for cancer research.