Xiaojuan Bian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiaojuan Bian has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Xiangchen Yang
Institute of High Energy Physics, Chinese Academy of Sciences
6 shared publications - Fusan Chen
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
4 shared publications - Ran Liang
Institute of High Energy Physics
3 shared publications - Xiangzhen Zhang
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
3 shared publications - Yuhui Li
Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 10049, P. R. China
3 shared publications - Chuang Shen
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
2 shared publications
Latest Publications
- 2 September 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics A
Design of superconducting quadrupole magnets in CEPC interaction region
High-gradient quadrupole magnets are required in the interaction region of the proposed circular electron positron collider (CEPC) to achieve high luminosity. On each side of the interaction point, there are three sets of dual-aperture superconducting quadrupole magnets, namely Q1a, Q1b and Q2. The angle between the two aperture centerlines is 33 mrad, and the required field gradient of the first quadrupole Q1a is as high as 142.3 T/m. The local dipole field in each quadrupole aperture is required to be smaller than 300 Gs. In view of the updated design requirements, an iron-free canted cosine theta (CCT) quadrupole coil design is selected. Two CCT technical routes are studied: the coil in groove of the skeleton scheme and the direct winding CCT coil scheme. Coil structure adjustment is employed to mitigate the magnetic field crosstalk between the two apertures. In this paper, the magnet design, field simulation, crosstalk compensation and design parameters of the three CCT quadrupole magnets are presented, and the two technical routes are compared and discussed.
- 2 September 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics A
Design of superconducting quadrupole magnets in CEPC interaction region
High-gradient quadrupole magnets are required in the interaction region of the proposed circular electron positron collider (CEPC) to achieve high luminosity. On each side of the interaction point, there are three sets of dual-aperture superconducting quadrupole magnets, namely Q1a, Q1b and Q2. The angle between the two aperture centerlines is 33 mrad, and the required field gradient of the first quadrupole Q1a is as high as 142.3 T/m. The local dipole field in each quadrupole aperture is required to be smaller than 300 Gs. In view of the updated design requirements, an iron-free canted cosine theta (CCT) quadrupole coil design is selected. Two CCT technical routes are studied: the coil in groove of the skeleton scheme and the direct winding CCT coil scheme. Coil structure adjustment is employed to mitigate the magnetic field crosstalk between the two apertures. In this paper, the magnet design, field simulation, crosstalk compensation and design parameters of the three CCT quadrupole magnets are presented, and the two technical routes are compared and discussed.
- 1 January 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (01) , P01011
Development of a high gradient superconducting quadrupole experimental magnet in CEPC interaction region
Compact high-gradient quadrupole magnets are required on both sides of the interaction points (IP) in the Circular Electron Positron Collider (CEPC) interaction region (IR). The dual-aperture superconducting quadrupole magnet Q1a is positioned closest to the IP with a crossing angle of 33 mrad between the two apertures. The electromagnetic design and development of Q1a faces great challenges due to the difficulties associated with the small aperture, high gradient and the magnetic field interference. This paper presents the electromagnetic design scheme of CEPC IR quadrupole magnets and the development of a high gradient superconducting quadrupole experimental magnet. Firstly, by comparing the electromagnetic properties and technological characteristics of three commonly used quadrupole superconducting coils, the design scheme of the superconducting quadrupole magnet for the CEPC final focusing system is determined. Then, the electromagnetic design and optimization of a cos 2θ experimental magnet is presented, the manufacturing process of the experimental magnet is introduced. Finally, the cryogenic excitation test of the experimental magnet is described and the physical design scheme of the high-gradient superconducting magnet for final focusing system in CEPC IR is verified.
- 1 January 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (01) , P01011
Development of a high gradient superconducting quadrupole experimental magnet in CEPC interaction region
Compact high-gradient quadrupole magnets are required on both sides of the interaction points (IP) in the Circular Electron Positron Collider (CEPC) interaction region (IR). The dual-aperture superconducting quadrupole magnet Q1a is positioned closest to the IP with a crossing angle of 33 mrad between the two apertures. The electromagnetic design and development of Q1a faces great challenges due to the difficulties associated with the small aperture, high gradient and the magnetic field interference. This paper presents the electromagnetic design scheme of CEPC IR quadrupole magnets and the development of a high gradient superconducting quadrupole experimental magnet. Firstly, by comparing the electromagnetic properties and technological characteristics of three commonly used quadrupole superconducting coils, the design scheme of the superconducting quadrupole magnet for the CEPC final focusing system is determined. Then, the electromagnetic design and optimization of a cos 2θ experimental magnet is presented, the manufacturing process of the experimental magnet is introduced. Finally, the cryogenic excitation test of the experimental magnet is described and the physical design scheme of the high-gradient superconducting magnet for final focusing system in CEPC IR is verified.
- 6 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Fabrication and Cryogenic Test of a 1.5-M-Long Planar Superconducting Undulator at IHEP
An R&D project aiming to develop superconducting undulators (SCUs) is in progress at the Institute of High Energy Physics (IHEP) in China. The insertion device group has produced a 1.5-m-long NbTi planar superconducting undulator prototype recently. This SCU prototype has a period length of 15 mm and a magnetic gap of 9.5 mm. The SCU was fabricated in a frame to be trained vertically in a Dewar submerged by liquid helium. After dozens of quenches, the maximum current in the superconducting coils reached 450 A. The magnetic field along the axis at different currents were obtained by a measurement system to characterize the local magnetic field distribution. We applied a gap adjustment method to improve the magnetic field quality. A cryostat has been specially designed for this 1.5-m-long SCU prototype. The SCU was installed in the cryostat to be cooled to 4.2 K successfully. A series of cryogenic tests for the SCU prototype in the cryostat are in progress.
- 6 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Fabrication and Cryogenic Test of a 1.5-M-Long Planar Superconducting Undulator at IHEP
An R&D project aiming to develop superconducting undulators (SCUs) is in progress at the Institute of High Energy Physics (IHEP) in China. The insertion device group has produced a 1.5-m-long NbTi planar superconducting undulator prototype recently. This SCU prototype has a period length of 15 mm and a magnetic gap of 9.5 mm. The SCU was fabricated in a frame to be trained vertically in a Dewar submerged by liquid helium. After dozens of quenches, the maximum current in the superconducting coils reached 450 A. The magnetic field along the axis at different currents were obtained by a measurement system to characterize the local magnetic field distribution. We applied a gap adjustment method to improve the magnetic field quality. A cryostat has been specially designed for this 1.5-m-long SCU prototype. The SCU was installed in the cryostat to be cooled to 4.2 K successfully. A series of cryogenic tests for the SCU prototype in the cryostat are in progress.
- Open Access
- 23 June 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (4) , 997-1003
Development and magnetic field measurement of a 0.5-m-long superconducting undulator at IHEP
Undulators are important devices for accelerator-based light sources whose magnetic field quality determines the photon beam performance. Superconducting-type undulators have been developing rapidly in recent years around the world. The insertion device group at the Institute of High Energy Physics (IHEP) in China started an R&D project to develop prototypes of superconducting undulators (SCUs). A half-meter-long planar SCU has been produced recently. The SCU was designed based on the simulation program OPERA-3D giving a period length of 15 mm and a gap of 7 mm. This prototype was manufactured and fabricated precisely, and was then tested by vertically submerging in liquid helium in a Dewar. After quench training several times, the maximum current in the main coils reached 480 A. The magnetic field was measured by Hall probes mounted on a sledge in the middle of the undulator gap. The peak magnetic field reached 1 T. The measurement results indicate that correction coils with suitable current can not only optimize the magnetic first and second integrals but also reduce the phase error, which is expected by design.
- 23 June 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (4) , 997-1003
Open AccessDevelopment and magnetic field measurement of a 0.5-m-long superconducting undulator at IHEP
Undulators are important devices for accelerator-based light sources whose magnetic field quality determines the photon beam performance. Superconducting-type undulators have been developing rapidly in recent years around the world. The insertion device group at the Institute of High Energy Physics (IHEP) in China started an R&D project to develop prototypes of superconducting undulators (SCUs). A half-meter-long planar SCU has been produced recently. The SCU was designed based on the simulation program OPERA-3D giving a period length of 15 mm and a gap of 7 mm. This prototype was manufactured and fabricated precisely, and was then tested by vertically submerging in liquid helium in a Dewar. After quench training several times, the maximum current in the main coils reached 480 A. The magnetic field was measured by Hall probes mounted on a sledge in the middle of the undulator gap. The peak magnetic field reached 1 T. The measurement results indicate that correction coils with suitable current can not only optimize the magnetic first and second integrals but also reduce the phase error, which is expected by design.
- 23 February 2022
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 33 (2) , 1-9
Superconducting multipole wiggler with large magnetic gap for HEPS-TF
- 23 February 2022
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 33 (2) , 1-9
Superconducting multipole wiggler with large magnetic gap for HEPS-TF
- 24 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Electromagnetic Design and Fabrication of LPF2: A 12-T Hybrid Common-Coil Dipole Magnet With Inserted IBS Coil
High field dipole magnets with common-coil configuration are under development at IHEP (the Institute of High Energy Physics, Chinese Academy of Sciences) for key technology pre-study of high energy colliders. A model magnet named LPF1 has been fabricated and tested in 2018, which was made up of 4 flat racetrack NbTi coils and 2 flat racetrack $\text{Nb}_3 \text{Sn}$ coils, and a main dipole field of 10.2 T has been reached in the two apertures at 4.2 K. A new model magnet LPF2 is being designed and fabricated in 2019, with 4 new $\text{Nb}_3 \text{Sn}$ coils included comparing with LPF1, and the magnet is expected to reach a much higher field. To reduce the field enhancement at the coil ends, the newly fabricated $\text{Nb}_3 \text{Sn}$ coils are designed with different straight lengths and bending radii. This hybrid dipole magnet is designed to provide a 12-T main field in the two apertures with an operating current of 5300 A, corresponding to a load line ratio of 78 % at 4.2 K. A single-pancake racetrack IBS (Iron-based superconducting) coil wound with a 100-m IBS tape would be inserted into the middle of the magnet (between the inner-most two $\text{Nb}_3 \text{Sn}$ coils). This magnet is also used to test the IBS coil performance under high field and high stress. The main design parameters, fabrication process of the magnet will be presented.- 24 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Electromagnetic Design and Fabrication of LPF2: A 12-T Hybrid Common-Coil Dipole Magnet With Inserted IBS Coil
High field dipole magnets with common-coil configuration are under development at IHEP (the Institute of High Energy Physics, Chinese Academy of Sciences) for key technology pre-study of high energy colliders. A model magnet named LPF1 has been fabricated and tested in 2018, which was made up of 4 flat racetrack NbTi coils and 2 flat racetrack $\text{Nb}_3 \text{Sn}$ coils, and a main dipole field of 10.2 T has been reached in the two apertures at 4.2 K. A new model magnet LPF2 is being designed and fabricated in 2019, with 4 new $\text{Nb}_3 \text{Sn}$ coils included comparing with LPF1, and the magnet is expected to reach a much higher field. To reduce the field enhancement at the coil ends, the newly fabricated $\text{Nb}_3 \text{Sn}$ coils are designed with different straight lengths and bending radii. This hybrid dipole magnet is designed to provide a 12-T main field in the two apertures with an operating current of 5300 A, corresponding to a load line ratio of 78 % at 4.2 K. A single-pancake racetrack IBS (Iron-based superconducting) coil wound with a 100-m IBS tape would be inserted into the middle of the magnet (between the inner-most two $\text{Nb}_3 \text{Sn}$ coils). This magnet is also used to test the IBS coil performance under high field and high stress. The main design parameters, fabrication process of the magnet will be presented.- Open Access
- 1 November 2013
- Published by IOP Publishing in Chinese Physics C
- Vol. 37 (11) , 117003
Classical and modern power spectrum estimation for tune measurement in CSNS RCS
- 1 November 2013
- Published by IOP Publishing in Chinese Physics C
- Vol. 37 (11) , 117003
Open AccessClassical and modern power spectrum estimation for tune measurement in CSNS RCS