Leonid S. Prokhorenko
Research Subjects
Leonid S. Prokhorenko has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Daniil D. Klimov
Russian University of Medicine
9 shared publications - Dmitry Nikolayevich Panchenkov
Russian University of Medicine
6 shared publications - Yuri V. Poduraev
Fsbei He “Rosunimed” of Moh of Russia, Moscow 127473, Russia
5 shared publications - Denis Mishchenkov
FSBEI HE “RUSSIAN UNIVERSITY OF MEDICINE” OF MOH OF RUSSIA Moscow Russia
4 shared publications - Kirill A. Tupikin
Russian University of Medicine
4 shared publications - R. V. Liskevich
Russian University of Medicine
4 shared publications
Latest Publications
- 21 October 2026
- Published by Media Sphere Publishing Group in Endoscopic Surgery
- Vol. 32 (5)
Intraoperative navigation using augmented reality technology and artificial intelligence in surgery
Objective.To summarize the clinical experience of using augmented reality for preoperative planning and intraoperative navigation across several surgical specialties. Material and methods. From 2022 through 2025, 74 AR-assisted procedures were performed at the University Clinic of the Russian University of Medicine, Ministry of Health of the Russian Federation. The series included procedures in abdominal, interventional, maxillofacial, reconstructive, head and neck, and urologic surgery. Results. Intraoperative setup of the AR system required no more than 15 min and did not materially increase the overall procedure time. Among patients with head and neck tumors, mean operating time was 110±10 min with AR guidance, compared with 130±10 min for comparable procedures performed without AR. Three-dimensional visualization influenced the choice of surgical approach in 5 of 14 patients (35.7%). No perioperative complications were recorded in this group. During transarterial chemoembolization, AR facilitated spatial interpretation of the vascular anatomy. Procedure and fluoroscopy times tended to be shorter, although the differences between groups did not reach statistical significance. Post-procedure Likert-scale ratings provided by the surgical teams supported the system’s usability and its perceived contribution to improved visualization and navigational accuracy. Conclusion. These findings support the clinical feasibility of AR navigation and suggest that it may be particularly useful in anatomically complex regions, in the presence of variant vascular anatomy, and when deep structures are poorly visualized. However, the heterogeneity of the study population and the absence of standardized outcome measures preclude regarding this series as definitive evidence of effectiveness. Further advances will require more accurate segmentation and spatial registration, compensation for intraoperative tissue deformation, and automation of routine model-preparation steps. The authors’ approach to the real-time accumulation of spatially registered ultrasound data represents a promising avenue for addressing some of these limitations.
- 21 October 2026
- Published by Media Sphere Publishing Group in Endoscopic Surgery
- Vol. 32 (5)
Intraoperative navigation using augmented reality technology and artificial intelligence in surgery
Objective.To summarize the clinical experience of using augmented reality for preoperative planning and intraoperative navigation across several surgical specialties. Material and methods. From 2022 through 2025, 74 AR-assisted procedures were performed at the University Clinic of the Russian University of Medicine, Ministry of Health of the Russian Federation. The series included procedures in abdominal, interventional, maxillofacial, reconstructive, head and neck, and urologic surgery. Results. Intraoperative setup of the AR system required no more than 15 min and did not materially increase the overall procedure time. Among patients with head and neck tumors, mean operating time was 110±10 min with AR guidance, compared with 130±10 min for comparable procedures performed without AR. Three-dimensional visualization influenced the choice of surgical approach in 5 of 14 patients (35.7%). No perioperative complications were recorded in this group. During transarterial chemoembolization, AR facilitated spatial interpretation of the vascular anatomy. Procedure and fluoroscopy times tended to be shorter, although the differences between groups did not reach statistical significance. Post-procedure Likert-scale ratings provided by the surgical teams supported the system’s usability and its perceived contribution to improved visualization and navigational accuracy. Conclusion. These findings support the clinical feasibility of AR navigation and suggest that it may be particularly useful in anatomically complex regions, in the presence of variant vascular anatomy, and when deep structures are poorly visualized. However, the heterogeneity of the study population and the absence of standardized outcome measures preclude regarding this series as definitive evidence of effectiveness. Further advances will require more accurate segmentation and spatial registration, compensation for intraoperative tissue deformation, and automation of routine model-preparation steps. The authors’ approach to the real-time accumulation of spatially registered ultrasound data represents a promising avenue for addressing some of these limitations.
- 27 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1320-1325
Development of a Mechatronic End-Effector for Robot-Assisted Ultrasound Guided Tool Navigation in Local Destruction Procedures
The article is devoted to the development and analysis of the design of a mechatronic end-effector for a medical manipulator intended for ultrasound guided local destruction methods. A plane-parallel kinematic scheme of the end-effector, which has three controllable axis, was proposed, and it provides guidance and maintenance of the ablation tool insertion trajectory in the scanning plane of the ultrasonic transducer. A kinematic analysis of the design was conducted, including the forward and inverse kinematics problems, and a method for the coordinated motion planning of the end-effector and the medical manipulator was proposed. Design solutions are aimed at minimizing the positioning error of the system by shifting the center of mass and increasing its overall rigidity. The main provisions of the control algorithm are presented, which allows to keep the ablation tool in the visualization plane when the transducer position changes. The theoretical evaluation demonstrates the potential of the proposed end-effector to improve the accuracy and efficiency of minimally invasive interventions in clinical practice. In the future, it is planned to manufacture a prototype and integrate it into a medical manipulator for experimental evaluation.
- 27 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1320-1325
Development of a Mechatronic End-Effector for Robot-Assisted Ultrasound Guided Tool Navigation in Local Destruction Procedures
The article is devoted to the development and analysis of the design of a mechatronic end-effector for a medical manipulator intended for ultrasound guided local destruction methods. A plane-parallel kinematic scheme of the end-effector, which has three controllable axis, was proposed, and it provides guidance and maintenance of the ablation tool insertion trajectory in the scanning plane of the ultrasonic transducer. A kinematic analysis of the design was conducted, including the forward and inverse kinematics problems, and a method for the coordinated motion planning of the end-effector and the medical manipulator was proposed. Design solutions are aimed at minimizing the positioning error of the system by shifting the center of mass and increasing its overall rigidity. The main provisions of the control algorithm are presented, which allows to keep the ablation tool in the visualization plane when the transducer position changes. The theoretical evaluation demonstrates the potential of the proposed end-effector to improve the accuracy and efficiency of minimally invasive interventions in clinical practice. In the future, it is planned to manufacture a prototype and integrate it into a medical manipulator for experimental evaluation.
- Open Access
- 27 June 2025
- Published by Annals of Surgical Hepatology in Annaly khirurgicheskoy gepatologii = Annals of HPB surgery
- Vol. 30 (2) , 13-22
Augmented reality technology in hepatopancreatobiliary surgery
Aim. To summarize the experience of applying augmented reality technology in hepatopancreatobiliary surgery.Materials and methods. From November 2021 to January 2024, 43 patients underwent surgery using augmented reality technology. These procedures included pancreatoduodenectomy, distal pancreatectomy, irreversible electroporation of neoplasms, pancreatic pseudocyst removal, resection of the common bile duct with biliodigestive anastomosis formation, atypical liver resections, right hemihepatectomy, and transarterial chemoembolization of hepatic tumor arteries.Results. The use of augmented reality technology showed no significant increase in operative time. In minimally invasive liver procedures, augmented reality proved to be a convenient navigation tool, contributing to reduced fluoroscopy duration and overall operative time. Analysis of Likert scales completed as feedback forms for intraoperative use by the surgical team demonstrated that augmented reality technology was convenient and beneficial for enhancing visualization and navigation.Conclusion. Augmented reality has proven to be an effective, reliable, and promising tool for hepatopancreatobiliary surgery. However, further technological advancements are required to fully realize its potential. Enhancing the performance of augmented reality systems – including their accuracy, stability, and adaptability to various clinical scenarios – will make them more dependable and versatile for a wide range of surgical procedures.
- 27 June 2025
- Published by Annals of Surgical Hepatology in Annaly khirurgicheskoy gepatologii = Annals of HPB surgery
- Vol. 30 (2) , 13-22
Open AccessAugmented reality technology in hepatopancreatobiliary surgery
Aim. To summarize the experience of applying augmented reality technology in hepatopancreatobiliary surgery.Materials and methods. From November 2021 to January 2024, 43 patients underwent surgery using augmented reality technology. These procedures included pancreatoduodenectomy, distal pancreatectomy, irreversible electroporation of neoplasms, pancreatic pseudocyst removal, resection of the common bile duct with biliodigestive anastomosis formation, atypical liver resections, right hemihepatectomy, and transarterial chemoembolization of hepatic tumor arteries.Results. The use of augmented reality technology showed no significant increase in operative time. In minimally invasive liver procedures, augmented reality proved to be a convenient navigation tool, contributing to reduced fluoroscopy duration and overall operative time. Analysis of Likert scales completed as feedback forms for intraoperative use by the surgical team demonstrated that augmented reality technology was convenient and beneficial for enhancing visualization and navigation.Conclusion. Augmented reality has proven to be an effective, reliable, and promising tool for hepatopancreatobiliary surgery. However, further technological advancements are required to fully realize its potential. Enhancing the performance of augmented reality systems – including their accuracy, stability, and adaptability to various clinical scenarios – will make them more dependable and versatile for a wide range of surgical procedures.
- 23 December 2024
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 20 (6) , e70033
Computer‐Guided Navigation System Efficiency Evaluation Using Surgical Instruments for Spinal Fusion
Background: Navigation surgical systems have been widely used in spinal fusion to ensure accuracy and safety during pedicle screw insertion.Methods: The research was performed under laboratory conditions, using stereotactic navigation, surgical instruments for spinal fusion, development of additional devices and software. During the experiments, all stages of the computed tomography‐guided navigation system use were performed—preoperative preparation of patient data and planning to provide visual control of the navigation of surgical instruments during the insertion of screws.Results: The 20 screws were inserted into the vertebrae of the lumbar spine phantom with an average pedicle width of 12.6 ± 1.29 mm with 100% clinical accuracy. The 30 screws were inserted into cadaveric sheep vertebrae with an average pedicle width of 6.56 ± 0.58 mm with 96.67% efficiency.Conclusions: The proposed navigation technique of the CT‐guided navigation system is highly effective in the navigation process of surgical instruments and pedicle screws during spinal fusion.
- 23 December 2024
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 20 (6) , e70033
Computer‐Guided Navigation System Efficiency Evaluation Using Surgical Instruments for Spinal Fusion
Background: Navigation surgical systems have been widely used in spinal fusion to ensure accuracy and safety during pedicle screw insertion.Methods: The research was performed under laboratory conditions, using stereotactic navigation, surgical instruments for spinal fusion, development of additional devices and software. During the experiments, all stages of the computed tomography‐guided navigation system use were performed—preoperative preparation of patient data and planning to provide visual control of the navigation of surgical instruments during the insertion of screws.Results: The 20 screws were inserted into the vertebrae of the lumbar spine phantom with an average pedicle width of 12.6 ± 1.29 mm with 100% clinical accuracy. The 30 screws were inserted into cadaveric sheep vertebrae with an average pedicle width of 6.56 ± 0.58 mm with 96.67% efficiency.Conclusions: The proposed navigation technique of the CT‐guided navigation system is highly effective in the navigation process of surgical instruments and pedicle screws during spinal fusion.
- 18 December 2024
- Published by Media Sphere Publishing Group in Endoscopic Surgery
- Vol. 30 (6)
Experimental evaluation of a prototype robot-assisted system for minimally invasive abdominal surgery using radiofrequency ablation as an example
Objective. Improving the quality of robot-assisted surgeries performed by methods of local destruction of liver tumors, reducing trauma for the patient and the load on the operating personnel. Material and methods. A prototype of a robot-assisted complex was developed, and a method for simulating liver tumors on cadaver material was proposed. Preoperative planning, intraoperative preparation, execution of a robot-assisted operation of local destruction on cadaver material, and estimation of numerical results were carried out. Results. The distance between the position of the target area determined by CT examination and the actually detected position ranged from 3.8 mm to 4.9 mm. Conclusion. A set of software and hardware tools for using robot-assisted complexes during preoperative planning, intraoperative preparation, and surgery execution using local destruction methods was proposed and tested.
- 18 December 2024
- Published by Media Sphere Publishing Group in Endoscopic Surgery
- Vol. 30 (6)
Experimental evaluation of a prototype robot-assisted system for minimally invasive abdominal surgery using radiofrequency ablation as an example
Objective. Improving the quality of robot-assisted surgeries performed by methods of local destruction of liver tumors, reducing trauma for the patient and the load on the operating personnel. Material and methods. A prototype of a robot-assisted complex was developed, and a method for simulating liver tumors on cadaver material was proposed. Preoperative planning, intraoperative preparation, execution of a robot-assisted operation of local destruction on cadaver material, and estimation of numerical results were carried out. Results. The distance between the position of the target area determined by CT examination and the actually detected position ranged from 3.8 mm to 4.9 mm. Conclusion. A set of software and hardware tools for using robot-assisted complexes during preoperative planning, intraoperative preparation, and surgery execution using local destruction methods was proposed and tested.
- 4 July 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 09 (03n04)
Closed-Form Kinematics Solutions for Redundant Medical Robots with Joint Limits and Singularity Avoidance
Closed-form forward and inverse position, velocity and acceleration kinematics problems solutions are developed for a redundant medical robot family. Developed solutions allow one to choose a specific joint as a set one. Solutions work in constant time, suitable for real-time operation. Methods for joint limit and singularity avoidance are proposed. Simulation experiments are performed on simulated KUKA MED 14 r820 robot.
- 4 July 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 09 (03n04)
Closed-Form Kinematics Solutions for Redundant Medical Robots with Joint Limits and Singularity Avoidance
Closed-form forward and inverse position, velocity and acceleration kinematics problems solutions are developed for a redundant medical robot family. Developed solutions allow one to choose a specific joint as a set one. Solutions work in constant time, suitable for real-time operation. Methods for joint limit and singularity avoidance are proposed. Simulation experiments are performed on simulated KUKA MED 14 r820 robot.
- Open Access
- 11 June 2024
- Published by Annals of Surgical Hepatology in Annaly khirurgicheskoy gepatologii = Annals of HPB surgery
- Vol. 29 (2) , 123-133
Algorithms for planning the trajectories of electrode insertion for radiofrequency ablation in robotic surgery
Aim. To improve the efficiency of radiofrequency ablation for large tumors by computer-aided modeling and planning of robotic surgery. Materials and methods. A set of algorithms for planning robotic electrode insertion was developed. Results. The evaluation of the technique proved its potential for achieving complete tumor processing and trajectory building with all feasible constraints. Conclusion. The set of algorithms provides computer-aid planning for sequential placement of radiofrequency ablation needles during intervention.
- 11 June 2024
- Published by Annals of Surgical Hepatology in Annaly khirurgicheskoy gepatologii = Annals of HPB surgery
- Vol. 29 (2) , 123-133
Open AccessAlgorithms for planning the trajectories of electrode insertion for radiofrequency ablation in robotic surgery
Aim. To improve the efficiency of radiofrequency ablation for large tumors by computer-aided modeling and planning of robotic surgery. Materials and methods. A set of algorithms for planning robotic electrode insertion was developed. Results. The evaluation of the technique proved its potential for achieving complete tumor processing and trajectory building with all feasible constraints. Conclusion. The set of algorithms provides computer-aid planning for sequential placement of radiofrequency ablation needles during intervention.
- Open Access
- 19 March 2023
- Published by Annals of Surgical Hepatology in Annaly khirurgicheskoy gepatologii = Annals of HPB surgery
- Vol. 28 (1) , 62-70
First experience of using augmented reality technology in liver and pancreas laparoscopy
Aim. To describe the experience of using augmented reality system in abdominal surgery at one clinical center.Materials and methods. In 2021–2022, five patients underwent laparoscopy with augmented reality technology. The interventions included echinococcectomy with resection of IV, V, VI liver segments, pancreaticoduodenal resection for pancreatic head cancer, excision of mesostenium cyst, resection of pancreas body and tail for neuroendocrine tumor.Results. Application of 3D models requires putting on glasses, scaling and setting a model on the screen image, which sometimes prolonged surgery time to 25 minutes. In a number of operations the use of augmented reality navigated the surgeon when working near vascular structures. After looking through the AR model, a surgeon felt more confident in terms of individual anatomy.Conclusion. Augmented reality can become a reliable and promising tool in abdominal surgery. However, further technological development in augmented reality systems is needed to increase their performance.
- 19 March 2023
- Published by Annals of Surgical Hepatology in Annaly khirurgicheskoy gepatologii = Annals of HPB surgery
- Vol. 28 (1) , 62-70
Open AccessFirst experience of using augmented reality technology in liver and pancreas laparoscopy
Aim. To describe the experience of using augmented reality system in abdominal surgery at one clinical center.Materials and methods. In 2021–2022, five patients underwent laparoscopy with augmented reality technology. The interventions included echinococcectomy with resection of IV, V, VI liver segments, pancreaticoduodenal resection for pancreatic head cancer, excision of mesostenium cyst, resection of pancreas body and tail for neuroendocrine tumor.Results. Application of 3D models requires putting on glasses, scaling and setting a model on the screen image, which sometimes prolonged surgery time to 25 minutes. In a number of operations the use of augmented reality navigated the surgeon when working near vascular structures. After looking through the AR model, a surgeon felt more confident in terms of individual anatomy.Conclusion. Augmented reality can become a reliable and promising tool in abdominal surgery. However, further technological development in augmented reality systems is needed to increase their performance.
- 8 June 2021
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 16 (2) , 445-452
The concept of spatial motion restriction zones in a robot-assisted surgical system
The development of robotics and medicine in recent years leads to increasing mutual integration of these two disciplines. The use of specialized robotic solutions in medicine poses new challenges, including the issue of safety. The paper analyzes existing solutions aimed at improving safety in medical robotics. The concept of spatial motion restriction zones—areas of space affecting the process of robot-assisted surgery and designed to minimize risks for the patient is proposed. Various applications of such zones are considered, such as: creating an optimal medical tool path when planning an operation, an adaptive movement restriction during manual manipulator control, including limiting maximum velocity. An approach to adaptively changing the parameters of motion restriction zones is presented, and possible data sources for this change are considered. A technique is introduced for using a hybrid motion restriction zone, combining several zones into a single complex system with various types of interaction. Approaches to manual control of a collaborative robot, including the use of force–torque sensors, are considered.
- 8 June 2021
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 16 (2) , 445-452
The concept of spatial motion restriction zones in a robot-assisted surgical system
The development of robotics and medicine in recent years leads to increasing mutual integration of these two disciplines. The use of specialized robotic solutions in medicine poses new challenges, including the issue of safety. The paper analyzes existing solutions aimed at improving safety in medical robotics. The concept of spatial motion restriction zones—areas of space affecting the process of robot-assisted surgery and designed to minimize risks for the patient is proposed. Various applications of such zones are considered, such as: creating an optimal medical tool path when planning an operation, an adaptive movement restriction during manual manipulator control, including limiting maximum velocity. An approach to adaptively changing the parameters of motion restriction zones is presented, and possible data sources for this change are considered. A technique is introduced for using a hybrid motion restriction zone, combining several zones into a single complex system with various types of interaction. Approaches to manual control of a collaborative robot, including the use of force–torque sensors, are considered.