Fumiaki Ichihashi
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Fumiaki Ichihashi has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Toshiaki Tanigaki
Research & Development Group, Hitachi, Ltd., Hatoyama, 350-0395, Japan
5 shared publications - Yoshio Takahashi
Research and Development Group, Hitachi, Ltd., Hatoyama, Saitama 350-0395, Japan
5 shared publications Hiroyuki Shinada
Research and Development Group, Hitachi, Ltd., Hatoyama, Saitama 350-0395, Japan
3 shared publicationsTetsuya Akashi
Research and Development Group, Hitachi, Ltd., Hatoyama, Saitama 350-0395, Japan
2 shared publicationsYasukazu Murakami
Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University 2 , Fukuoka 819-0395, Japan
2 shared publicationsAkira Koyama
Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University 2 , Fukuoka 819-0395, Japan
1 shared publication
Latest Publications
- 24 June 2025
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 75 (1) , 21-28
Reduction of membrane-derived noise using beam-tilt measurement and deep learning in observation using environmental cell
Electron microscopy using an environmental cell is a powerful tool for observing catalysts and other nanomaterials in gases and liquids. An environmental cell must contain amorphous silicon-nitride membranes because they protect the sample environment from the vacuum of the electron microscope and enable the electron beam to pass through the cell. However, the membranes superimpose non-uniform contrast on the projected image, degrading image quality. We propose a method for removing the noise derived from the membranes using Noise2Noise, a deep-learning method, for a series of transmission-electron-microscope images with slight electron-beam tilt and evaluated its effectiveness. We succeeded in removing the membrane-derived noise while retaining the information of the sample in the cell. We also succeeded in efficiently removing Poisson noise. We believe this method will enable measurements requiring high signal-to-noise ratios, which could previously only be observed in a vacuum, to be conducted in an environmental cell.
- 24 June 2025
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 75 (1) , 21-28
Reduction of membrane-derived noise using beam-tilt measurement and deep learning in observation using environmental cell
Electron microscopy using an environmental cell is a powerful tool for observing catalysts and other nanomaterials in gases and liquids. An environmental cell must contain amorphous silicon-nitride membranes because they protect the sample environment from the vacuum of the electron microscope and enable the electron beam to pass through the cell. However, the membranes superimpose non-uniform contrast on the projected image, degrading image quality. We propose a method for removing the noise derived from the membranes using Noise2Noise, a deep-learning method, for a series of transmission-electron-microscope images with slight electron-beam tilt and evaluated its effectiveness. We succeeded in removing the membrane-derived noise while retaining the information of the sample in the cell. We also succeeded in efficiently removing Poisson noise. We believe this method will enable measurements requiring high signal-to-noise ratios, which could previously only be observed in a vacuum, to be conducted in an environmental cell.
- 16 October 2024
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 74 (2) , 92-97
Resolution improvement of differential phase-contrast microscopy via tilt-series acquisition for environmental cell application
A simple method that improves the resolution of phase measurement in differential phase-contrast scanning transmission electron microscopy for closed-type environmental cell applications was developed and tested using a model sample simulating environmental cell observations. Because the top and bottom membranes of an environmental cell are typically far apart, the images from these membranes are shifted widely by tilt-series acquisition, and averaging the images after alignment can effectively eliminate undesired signals from the membranes while improving the signal from the object of interest. It was demonstrated that a phase precision of 2π/100 rad is well achievable using the proposed method for the sample in an environmental cell.
- 16 October 2024
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 74 (2) , 92-97
Resolution improvement of differential phase-contrast microscopy via tilt-series acquisition for environmental cell application
A simple method that improves the resolution of phase measurement in differential phase-contrast scanning transmission electron microscopy for closed-type environmental cell applications was developed and tested using a model sample simulating environmental cell observations. Because the top and bottom membranes of an environmental cell are typically far apart, the images from these membranes are shifted widely by tilt-series acquisition, and averaging the images after alignment can effectively eliminate undesired signals from the membranes while improving the signal from the object of interest. It was demonstrated that a phase precision of 2π/100 rad is well achievable using the proposed method for the sample in an environmental cell.
- 14 October 2022
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 378 (6616) , 202-206
Direct identification of the charge state in a single platinum nanoparticle on titanium oxide
A goal in the characterization of supported metal catalysts is to achieve particle-by-particle analysis of the charge state strongly correlated with the catalytic activity. Here, we demonstrate the direct identification of the charge state of individual platinum nanoparticles (NPs) supported on titanium dioxide using ultrahigh sensitivity and precision electron holography. Sophisticated phase-shift analysis for the part of the NPs protruding into the vacuum visualized slight potential changes around individual platinum NPs. The analysis revealed the number (only one to six electrons) and sense (positive or negative) of the charge per platinum NP. The underlying mechanism of platinum charging is explained by the work function differences between platinum and titanium dioxide (depending on the orientation relationship and lattice distortion) and by first-principles calculations in terms of the charge transfer processes.
- 14 October 2022
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 378 (6616) , 202-206
Direct identification of the charge state in a single platinum nanoparticle on titanium oxide
A goal in the characterization of supported metal catalysts is to achieve particle-by-particle analysis of the charge state strongly correlated with the catalytic activity. Here, we demonstrate the direct identification of the charge state of individual platinum nanoparticles (NPs) supported on titanium dioxide using ultrahigh sensitivity and precision electron holography. Sophisticated phase-shift analysis for the part of the NPs protruding into the vacuum visualized slight potential changes around individual platinum NPs. The analysis revealed the number (only one to six electrons) and sense (positive or negative) of the charge per platinum NP. The underlying mechanism of platinum charging is explained by the work function differences between platinum and titanium dioxide (depending on the orientation relationship and lattice distortion) and by first-principles calculations in terms of the charge transfer processes.
- Open Access
- 7 February 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (6) , 064103
Automatic electron hologram acquisition of catalyst nanoparticles using particle detection with image processing and machine learning
To enable better statistical analysis of catalyst nanoparticles by high-resolution electron holography, we improved the particle detection accuracy of our previously developed automated hologram acquisition system by using an image classifier trained with machine learning. The detection accuracy of 83% was achieved with the small training data of just 232 images showing nanoparticles by utilizing transfer learning based on VGG16 to train the image classifier. Although the construction of training data generally requires much effort, the time needed to select the training data candidates was significantly shortened by utilizing a pattern matching technique. Experimental results showed that the high-resolution hologram acquisition efficiency was improved by factors of about 100 and 6 compared to a scan method and a pattern-matching-only method, respectively.
- 7 February 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (6) , 064103
Open AccessAutomatic electron hologram acquisition of catalyst nanoparticles using particle detection with image processing and machine learning
To enable better statistical analysis of catalyst nanoparticles by high-resolution electron holography, we improved the particle detection accuracy of our previously developed automated hologram acquisition system by using an image classifier trained with machine learning. The detection accuracy of 83% was achieved with the small training data of just 232 images showing nanoparticles by utilizing transfer learning based on VGG16 to train the image classifier. Although the construction of training data generally requires much effort, the time needed to select the training data candidates was significantly shortened by utilizing a pattern matching technique. Experimental results showed that the high-resolution hologram acquisition efficiency was improved by factors of about 100 and 6 compared to a scan method and a pattern-matching-only method, respectively.
- 25 June 2021
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 70 (6) , 510-518
Improved efficiency in automated acquisition of ultra-high-resolution electron holograms using automated target detection
An automated hologram acquisition system for big-data analysis and for improving the statistical precision of phase analysis has been upgraded with automated particle detection technology. The coordinates of objects in low-magnification images are automatically detected using zero-mean normalized cross-correlation with preselected reference images. In contrast with the conventional scanning acquisitions from the whole area of a microgrid and/or a thin specimen, the new method allows efficient data collections only from the desired fields of view including the particles. The acquisition time of the cubic/triangular nanoparticles that were observed was shortened by about one-fifty eighth that of the conventional scanning acquisition method because of efficient data collections. The developed technology can improve statistical precision in electron holography with shorter acquisition time and is applicable to the analysis of electromagnetic fields for various kinds of nanoparticles.
- 25 June 2021
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 70 (6) , 510-518
Improved efficiency in automated acquisition of ultra-high-resolution electron holograms using automated target detection
An automated hologram acquisition system for big-data analysis and for improving the statistical precision of phase analysis has been upgraded with automated particle detection technology. The coordinates of objects in low-magnification images are automatically detected using zero-mean normalized cross-correlation with preselected reference images. In contrast with the conventional scanning acquisitions from the whole area of a microgrid and/or a thin specimen, the new method allows efficient data collections only from the desired fields of view including the particles. The acquisition time of the cubic/triangular nanoparticles that were observed was shortened by about one-fifty eighth that of the conventional scanning acquisition method because of efficient data collections. The developed technology can improve statistical precision in electron holography with shorter acquisition time and is applicable to the analysis of electromagnetic fields for various kinds of nanoparticles.
- Open Access
- 1 July 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (7) , 073103
Development of angle-resolved spectroscopy system of electrons emitted from a surface with negative electron affinity state
We developed an angle-resolved photoemission spectroscopy system for the analysis of conduction-band electrons. By forming a negative electron affinity surface on a semiconductor surface, electrons in conduction bands are emitted into a vacuum and measured by using an analyzer. This method enables us to determine the energy and momentum of the conduction electrons. Furthermore, it can be used to determine unoccupied conduction band structures. The main challenges of this method are that the energies of the emitted electrons are extremely low and the trajectories of the electrons change due to various influences. We overcame these problems by placing the shielding mesh close to the sample and parallel to the sample surface. The entire chambers, including the shielding mesh, were grounded, and a negative bias voltage was applied only to the sample. This configuration realizes the acceleration of electrons while preserving the momentum component parallel to the sample surface. Another problem is the establishment of a method for converting a detected angle into the corresponding wavevector. We focused on the emission angle of electrons emitted from a sample and their minimum energy and then established an analytical method for converting detected angles into corresponding wavevectors on the basis of the minimum energy.
- 1 July 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (7) , 073103
Open AccessDevelopment of angle-resolved spectroscopy system of electrons emitted from a surface with negative electron affinity state
We developed an angle-resolved photoemission spectroscopy system for the analysis of conduction-band electrons. By forming a negative electron affinity surface on a semiconductor surface, electrons in conduction bands are emitted into a vacuum and measured by using an analyzer. This method enables us to determine the energy and momentum of the conduction electrons. Furthermore, it can be used to determine unoccupied conduction band structures. The main challenges of this method are that the energies of the emitted electrons are extremely low and the trajectories of the electrons change due to various influences. We overcame these problems by placing the shielding mesh close to the sample and parallel to the sample surface. The entire chambers, including the shielding mesh, were grounded, and a negative bias voltage was applied only to the sample. This configuration realizes the acceleration of electrons while preserving the momentum component parallel to the sample surface. Another problem is the establishment of a method for converting a detected angle into the corresponding wavevector. We focused on the emission angle of electrons emitted from a sample and their minimum energy and then established an analytical method for converting detected angles into corresponding wavevectors on the basis of the minimum energy.