Ting Gong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ting Gong has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
- Hongjiang Wei
School of Physics, Zhejiang University, Hangzhou, China
7 shared publications - Jianhui Zhong
Center for Brain Imaging Science and Technology, Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrumental Science, Zhejiang University, Hangzhou, Zhejiang, China; Department of Imaging Sciences, University of Rochester, Rochester, NY, USA
4 shared publications Qiqi Tong
Center for Brain Imaging Science and Technology, College of Biomedical Engineering and Instrumental Science, Zhejiang University, Hangzhou, China
3 shared publicationsYi Sun
MR Collaboration, Siemens Healthcare, Shanghai, China
3 shared publicationsAnastasia Yendiki
Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, United States
2 shared publicationsChen Li
Center for Brain Imaging Science and Technology, Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrumental Science, Zhejiang University, Hangzhou, Zhejiang, China
2 shared publications
Latest Publications
- Open Access
Hierarchical X-ray microscopy and mesoscopic diffusion MRI in the same brain reveal the human connectome across scales
We present a multimodal pipeline for 3D imaging of cerebral white-matter archi-tecture across scales, from whole-brain axonal projections down to individual myelinated axons. After diffusion MRI, an adult ex vivo human hemisphere undergoes label-free imaging with Hierarchical Phase-Contrast Tomography (HiP-CT) from 20 µm/voxel in the whole hemisphere to 2 µm/voxel in areas of interest, with intrinsic cross-scale alignment. A 4 cm tissue block extracted from the hemisphere is reimaged with HiP-CT at 0.857 µm/voxel, enabling direct visualisation of single myelinated axons. After osmium staining, micro-CT at 0.364 µm/voxel and electron microscopy at 4 nm/voxel are acquired in biop-sies from the tissue block to validate the presence of myelinated axons in the label-free HiP-CT contrast. Spanning three orders of magnitude in resolution, these co-registered multimodal datasets bridge microscopic wiring and macro-scopic brain organisation, providing a foundation for anatomically grounded whole-brain connectomics.
Open AccessHierarchical X-ray microscopy and mesoscopic diffusion MRI in the same brain reveal the human connectome across scales
We present a multimodal pipeline for 3D imaging of cerebral white-matter archi-tecture across scales, from whole-brain axonal projections down to individual myelinated axons. After diffusion MRI, an adult ex vivo human hemisphere undergoes label-free imaging with Hierarchical Phase-Contrast Tomography (HiP-CT) from 20 µm/voxel in the whole hemisphere to 2 µm/voxel in areas of interest, with intrinsic cross-scale alignment. A 4 cm tissue block extracted from the hemisphere is reimaged with HiP-CT at 0.857 µm/voxel, enabling direct visualisation of single myelinated axons. After osmium staining, micro-CT at 0.364 µm/voxel and electron microscopy at 4 nm/voxel are acquired in biop-sies from the tissue block to validate the presence of myelinated axons in the label-free HiP-CT contrast. Spanning three orders of magnitude in resolution, these co-registered multimodal datasets bridge microscopic wiring and macro-scopic brain organisation, providing a foundation for anatomically grounded whole-brain connectomics.
- Open Access
- 22 January 2026
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
Microstructure.jl: A Julia package for probabilistic microstructure model fitting with diffusion MRI
Microstructure.jl is a Julia package designed for probabilistic estimation of tissue microstructural parameters from diffusion or combined diffusion–relaxometry MRI data. It provides a flexible and extensible framework for defining compartment models and includes robust and unified estimators for parameter fitting and uncertainty quantification. The package incorporates several established models from the literature, such as the spherical mean technique (SMT), standard model imaging (SMI), and soma and neurite density imaging (SANDI), along with their extensions for analyzing combined diffusion and T2 mapping data acquired at multiple echo times. For parameter estimation, it features methods such as Markov Chain Monte Carlo (MCMC) sampling and Monte Carlo dropout with neural networks, which provide probabilistic estimates by approximating the posterior distributions of model parameters. In this study, we introduce the major modules, functionality, and design of this package. We demonstrate its usage in optimizing acquisition protocols and evaluating fitting performance with synthesized ex vivo datasets for estimating the axon diameter index. We also demonstrate its practical applications for parameter estimation and uncertainty quantification with publicly available in vivo datasets: (1) SMT on 3 b-shell and 1.25-mm isotropic resolution data from the human connectome project, (2) SANDI on 2.0-mm isotropic resolution microstructure data from the high-gradient Connectome 1.0 scanner, and (3) SMI with a free water compartment on 2 b-shell, multi-echo-time, 2.5-mm isotropic resolution data from a Prisma scanner. Microstructure.jl is applicable to in vivo and ex vivo imaging data acquired with typical research, high-performance, or pre-clinical scanners.
- 22 January 2026
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
Open AccessMicrostructure.jl: A Julia package for probabilistic microstructure model fitting with diffusion MRI
Microstructure.jl is a Julia package designed for probabilistic estimation of tissue microstructural parameters from diffusion or combined diffusion–relaxometry MRI data. It provides a flexible and extensible framework for defining compartment models and includes robust and unified estimators for parameter fitting and uncertainty quantification. The package incorporates several established models from the literature, such as the spherical mean technique (SMT), standard model imaging (SMI), and soma and neurite density imaging (SANDI), along with their extensions for analyzing combined diffusion and T2 mapping data acquired at multiple echo times. For parameter estimation, it features methods such as Markov Chain Monte Carlo (MCMC) sampling and Monte Carlo dropout with neural networks, which provide probabilistic estimates by approximating the posterior distributions of model parameters. In this study, we introduce the major modules, functionality, and design of this package. We demonstrate its usage in optimizing acquisition protocols and evaluating fitting performance with synthesized ex vivo datasets for estimating the axon diameter index. We also demonstrate its practical applications for parameter estimation and uncertainty quantification with publicly available in vivo datasets: (1) SMT on 3 b-shell and 1.25-mm isotropic resolution data from the human connectome project, (2) SANDI on 2.0-mm isotropic resolution microstructure data from the high-gradient Connectome 1.0 scanner, and (3) SMI with a free water compartment on 2 b-shell, multi-echo-time, 2.5-mm isotropic resolution data from a Prisma scanner. Microstructure.jl is applicable to in vivo and ex vivo imaging data acquired with typical research, high-performance, or pre-clinical scanners.
- Open Access
- 12 May 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Interplay between MRI-based axon diameter and myelination estimates in macaque and human brain
Axon diameter and myelin thickness affect the conduction velocity of action potentials in the nervous system. Imaging them non-invasively with MRI-based methods is, thus, valuable for studying brain microstructure and function. Electron microscopy studies suggest that axon diameter and myelin thickness are closely related to each other. However, the relationship between MRI-based estimates of these microstructural measures, known to be relative indices, has not been investigated across the brain mainly due to methodological limitations. In recent years, studies using ultra-high-gradient strength diffusion MRI (dMRI) have demonstrated improved estimation of axon diameter index across white-matter (WM) tracts in the human brain, making such investigations feasible. In this study, we aim to investigate relationships between tissue microstructure properties across white-matter tracts, as estimated with MRI-based methods. We collected dMRI with ultra-high-gradient strength and multi-echo spin-echo MRI on ex vivo macaque and human brain samples on a preclinical scanner. From these data, we estimated axon diameter index, intra-axonal signal fraction, myelin water fraction (MWF), and aggregate g-ratio and investigated their correlations. We found that the correlations between axon diameter index and other microstructural imaging parameters were weak but consistent across WM tracts in samples estimated with sufficient signal-to-noise ratio. In well-myelinated regions, tissue voxels with larger axon diameter indices were associated with lower packing density, lower MWF, and a tendency of higher g-ratio. We also found that intra-axonal signal fractions and MWF were not consistently correlated when assessed in different samples. Overall, the findings suggest that MRI-based axon geometry and myelination measures can provide complementary information about fiber morphology, and the relationships between these measures agree with prior electron microscopy studies in smaller field of views. Combining these advanced measures to characterize tissue morphology may help differentiate tissue changes during disease processes such as demyelination versus axonal damage. The regional variations and relationships of microstructural measures in control samples as reported in this study may serve as a point of reference for investigating such tissue changes in disease.
- 12 May 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Open AccessInterplay between MRI-based axon diameter and myelination estimates in macaque and human brain
Axon diameter and myelin thickness affect the conduction velocity of action potentials in the nervous system. Imaging them non-invasively with MRI-based methods is, thus, valuable for studying brain microstructure and function. Electron microscopy studies suggest that axon diameter and myelin thickness are closely related to each other. However, the relationship between MRI-based estimates of these microstructural measures, known to be relative indices, has not been investigated across the brain mainly due to methodological limitations. In recent years, studies using ultra-high-gradient strength diffusion MRI (dMRI) have demonstrated improved estimation of axon diameter index across white-matter (WM) tracts in the human brain, making such investigations feasible. In this study, we aim to investigate relationships between tissue microstructure properties across white-matter tracts, as estimated with MRI-based methods. We collected dMRI with ultra-high-gradient strength and multi-echo spin-echo MRI on ex vivo macaque and human brain samples on a preclinical scanner. From these data, we estimated axon diameter index, intra-axonal signal fraction, myelin water fraction (MWF), and aggregate g-ratio and investigated their correlations. We found that the correlations between axon diameter index and other microstructural imaging parameters were weak but consistent across WM tracts in samples estimated with sufficient signal-to-noise ratio. In well-myelinated regions, tissue voxels with larger axon diameter indices were associated with lower packing density, lower MWF, and a tendency of higher g-ratio. We also found that intra-axonal signal fractions and MWF were not consistently correlated when assessed in different samples. Overall, the findings suggest that MRI-based axon geometry and myelination measures can provide complementary information about fiber morphology, and the relationships between these measures agree with prior electron microscopy studies in smaller field of views. Combining these advanced measures to characterize tissue morphology may help differentiate tissue changes during disease processes such as demyelination versus axonal damage. The regional variations and relationships of microstructural measures in control samples as reported in this study may serve as a point of reference for investigating such tissue changes in disease.
- 29 December 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (6) , 2278-2293
High‐resolution myelin‐water fraction and quantitative relaxation mapping using 3D ViSTa‐MR fingerprinting
Purpose: This study aims to develop a high‐resolution whole‐brain multi‐parametric quantitative MRI approach for simultaneous mapping of myelin‐water fraction (MWF), T1, T2, and proton‐density (PD), all within a clinically feasible scan time.Methods: We developed 3D visualization of short transverse relaxation time component (ViSTa)‐MRF, which combined ViSTa technique with MR fingerprinting (MRF), to achieve high‐fidelity whole‐brain MWF and T1/T2/PD mapping on a clinical 3T scanner. To achieve fast acquisition and memory‐efficient reconstruction, the ViSTa‐MRF sequence leverages an optimized 3D tiny‐golden‐angle‐shuffling spiral‐projection acquisition and joint spatial–temporal subspace reconstruction with optimized preconditioning algorithm. With the proposed ViSTa‐MRF approach, high‐fidelity direct MWF mapping was achieved without a need for multicompartment fitting that could introduce bias and/or noise from additional assumptions or priors.Results: The in vivo results demonstrate the effectiveness of the proposed acquisition and reconstruction framework to provide fast multi‐parametric mapping with high SNR and good quality. The in vivo results of 1 mm‐ and 0.66 mm‐isotropic resolution datasets indicate that the MWF values measured by the proposed method are consistent with standard ViSTa results that are 30× slower with lower SNR. Furthermore, we applied the proposed method to enable 5‐min whole‐brain 1 mm‐iso assessment of MWF and T1/T2/PD mappings for infant brain development and for post‐mortem brain samples.Conclusions: In this work, we have developed a 3D ViSTa‐MRF technique that enables the acquisition of whole‐brain MWF, quantitative T1, T2, and PD maps at 1 and 0.66 mm isotropic resolution in 5 and 15 min, respectively. This advancement allows for quantitative investigations of myelination changes in the brain.
- 29 December 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (6) , 2278-2293
High‐resolution myelin‐water fraction and quantitative relaxation mapping using 3D ViSTa‐MR fingerprinting
Purpose: This study aims to develop a high‐resolution whole‐brain multi‐parametric quantitative MRI approach for simultaneous mapping of myelin‐water fraction (MWF), T1, T2, and proton‐density (PD), all within a clinically feasible scan time.Methods: We developed 3D visualization of short transverse relaxation time component (ViSTa)‐MRF, which combined ViSTa technique with MR fingerprinting (MRF), to achieve high‐fidelity whole‐brain MWF and T1/T2/PD mapping on a clinical 3T scanner. To achieve fast acquisition and memory‐efficient reconstruction, the ViSTa‐MRF sequence leverages an optimized 3D tiny‐golden‐angle‐shuffling spiral‐projection acquisition and joint spatial–temporal subspace reconstruction with optimized preconditioning algorithm. With the proposed ViSTa‐MRF approach, high‐fidelity direct MWF mapping was achieved without a need for multicompartment fitting that could introduce bias and/or noise from additional assumptions or priors.Results: The in vivo results demonstrate the effectiveness of the proposed acquisition and reconstruction framework to provide fast multi‐parametric mapping with high SNR and good quality. The in vivo results of 1 mm‐ and 0.66 mm‐isotropic resolution datasets indicate that the MWF values measured by the proposed method are consistent with standard ViSTa results that are 30× slower with lower SNR. Furthermore, we applied the proposed method to enable 5‐min whole‐brain 1 mm‐iso assessment of MWF and T1/T2/PD mappings for infant brain development and for post‐mortem brain samples.Conclusions: In this work, we have developed a 3D ViSTa‐MRF technique that enables the acquisition of whole‐brain MWF, quantitative T1, T2, and PD maps at 1 and 0.66 mm isotropic resolution in 5 and 15 min, respectively. This advancement allows for quantitative investigations of myelination changes in the brain.
- 1 November 2020
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 73, 31-44
A deep learning–based method for improving reliability of multicenter diffusion kurtosis imaging with varied acquisition protocols
- 1 November 2020
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 73, 31-44
A deep learning–based method for improving reliability of multicenter diffusion kurtosis imaging with varied acquisition protocols
- Open Access
- 1 August 2020
- Published by Elsevier in NeuroImage
- Vol. 217, 116906
MTE-NODDI: Multi-TE NODDI for disentangling non-T2-weighted signal fractions from compartment-specific T2 relaxation times
- 1 August 2020
- Published by Elsevier in NeuroImage
- Vol. 217, 116906
Open AccessMTE-NODDI: Multi-TE NODDI for disentangling non-T2-weighted signal fractions from compartment-specific T2 relaxation times
- Open Access
- 27 May 2020
- Published by Springer Nature in Scientific Data
- Vol. 7 (1) , 1-7
Multicenter dataset of multi-shell diffusion MRI in healthy traveling adults with identical settings
Multicenter diffusion magnetic resonance imaging (MRI) has drawn great attention recently due to the expanding need for large-scale brain imaging studies, whereas the variability in MRI scanners and data acquisition tends to confound reliable individual-based analysis of diffusion measures. In addition, a growing number of multi-shell diffusion models have been shown with the potential to generate various estimates of physio-pathological information, yet their reliability and reproducibility in multicenter studies remain to be assessed. In this article, we describe a multi-shell diffusion dataset collected from three traveling subjects with identical acquisition settings in ten imaging centers. Both the scanner type and imaging protocol for anatomical and diffusion imaging were well controlled. This dataset is expected to replenish individual reproducible studies via multicenter collaboration by providing an open resource for advanced and novel microstructural and tractography modelling and quantification.
- 27 May 2020
- Published by Springer Nature in Scientific Data
- Vol. 7 (1) , 1-7
Open AccessMulticenter dataset of multi-shell diffusion MRI in healthy traveling adults with identical settings
Multicenter diffusion magnetic resonance imaging (MRI) has drawn great attention recently due to the expanding need for large-scale brain imaging studies, whereas the variability in MRI scanners and data acquisition tends to confound reliable individual-based analysis of diffusion measures. In addition, a growing number of multi-shell diffusion models have been shown with the potential to generate various estimates of physio-pathological information, yet their reliability and reproducibility in multicenter studies remain to be assessed. In this article, we describe a multi-shell diffusion dataset collected from three traveling subjects with identical acquisition settings in ten imaging centers. Both the scanner type and imaging protocol for anatomical and diffusion imaging were well controlled. This dataset is expected to replenish individual reproducible studies via multicenter collaboration by providing an open resource for advanced and novel microstructural and tractography modelling and quantification.
- 1 June 2019
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 59, 1-9
Reproducibility of multi-shell diffusion tractography on traveling subjects: A multicenter study prospective
- 1 June 2019
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 59, 1-9
Reproducibility of multi-shell diffusion tractography on traveling subjects: A multicenter study prospective
- Open Access
- 27 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 71398-71411
Fast and Robust Diffusion Kurtosis Parametric Mapping Using a Three-Dimensional Convolutional Neural Network
Diffusion kurtosis imaging (DKI) is an advanced diffusion imaging method that captures complex brain microstructural properties; however, it often has a lengthy acquisition time compared to conventional diffusion tensor imaging (DTI). Recently, a deep learning-based method has shown potential for reducing the number of diffusion-weighted images (DWIs) required to compute the rotationally invariant scalar measures to twelve. In this study, we propose a three-dimensional (3D) convolutional neural network (CNN) to estimate the scalar measures. This network further improves the performance of the deep learning-based method with a largely reduced number of required DWIs. In our approach, all the DTI and DKI measures were estimated using a single network, and a hierarchical structure was introduced to customize the outputs based on their computational complexities and to learn the commonalities of the measures. Moreover, 3×3×3 convolution kernels were introduced to extract features from the 3D input patches and utilize the spatial context from adjacent neighborhoods, which also strengthened the network’s robustness against noise. The proposed method was evaluated with two datasets. The results showed that, compared with the previous method that used an artificial neural network, our proposed hierarchical CNN provided enhanced efficiency for estimating all eight diffusion measures. It also improved the robustness against noise and retained the fine structures with only a few DWIs (as few as eight). This result suggests that it is possible to achieve kurtosis mapping in most clinical scanners within one minute, which could significantly extend the clinical utility of DKI.
- 27 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 71398-71411
Open AccessFast and Robust Diffusion Kurtosis Parametric Mapping Using a Three-Dimensional Convolutional Neural Network
Diffusion kurtosis imaging (DKI) is an advanced diffusion imaging method that captures complex brain microstructural properties; however, it often has a lengthy acquisition time compared to conventional diffusion tensor imaging (DTI). Recently, a deep learning-based method has shown potential for reducing the number of diffusion-weighted images (DWIs) required to compute the rotationally invariant scalar measures to twelve. In this study, we propose a three-dimensional (3D) convolutional neural network (CNN) to estimate the scalar measures. This network further improves the performance of the deep learning-based method with a largely reduced number of required DWIs. In our approach, all the DTI and DKI measures were estimated using a single network, and a hierarchical structure was introduced to customize the outputs based on their computational complexities and to learn the commonalities of the measures. Moreover, 3×3×3 convolution kernels were introduced to extract features from the 3D input patches and utilize the spatial context from adjacent neighborhoods, which also strengthened the network’s robustness against noise. The proposed method was evaluated with two datasets. The results showed that, compared with the previous method that used an artificial neural network, our proposed hierarchical CNN provided enhanced efficiency for estimating all eight diffusion measures. It also improved the robustness against noise and retained the fine structures with only a few DWIs (as few as eight). This result suggests that it is possible to achieve kurtosis mapping in most clinical scanners within one minute, which could significantly extend the clinical utility of DKI.
- 22 April 2019
- Published by Wiley in Medical Physics
- Vol. 46 (7) , 3101-3116
Fast learning of fiber orientation distribution function for MR tractography using convolutional neural network
Purpose: In diffusion‐weighted magnetic resonance imaging (DW‐MRI), the fiber orientation distribution function (fODF) is of great importance for solving complex fiber configurations to achieve reliable tractography throughout the brain, which ultimately facilitates the understanding of brain connectivity and exploration of neurological dysfunction. Recently, multi‐shell multi‐tissue constrained spherical deconvolution (MSMT‐CSD) method has been explored for reconstructing full fODFs. To achieve a reliable fitting, similar to other model‐based approaches, a large number of diffusion measurements is typically required for MSMT‐CSD method. The prolonged acquisition is, however, not feasible in practical clinical routine and is prone to motion artifacts. To accelerate the acquisition, we proposed a method to reconstruct the fODF from downsampled diffusion‐weighted images (DWIs) by leveraging the strong inference ability of the deep convolutional neural network (CNN).Methods: The method treats spherical harmonics (SH)‐represented DWI signals and fODF coefficients as inputs and outputs, respectively. To compensate for the reduced gradient directions with reduced number of DWIs in acquisition in each voxel, its surrounding voxels are incorporated by the network for exploiting their spatial continuity. The resulting fODF coefficients are fitted with applying the CNN in a multi‐target regression model. The network is composed of two convolutional layers and three fully connected layers. To obtain an initial evaluation of the method, we quantitatively measured its performance on a simulated dataset. Then, for in vivo tests, we employed data from 24 subjects from the Human Connectome Project (HCP) as training set and six subjects as test set. The performance of the proposed method was primarily compared to the super‐resolved MSMT‐CSD with the decreasing number of DWIs. The fODFs reconstructed by MSMT‐CSD from all available 288 DWIs were used as training labels and the reference standard. The performance was quantitatively measured by the angular correlation coefficient (ACC) and the mean angular error (MAE).Results: For the simulated dataset, the proposed method exhibited the potential advantage over the model reconstruction. For the in vivo dataset, it achieved superior results over the MSMT‐CSD in all the investigated cases, with its advantage more obvious when a limited number of DWIs were used. As the number of DWIs was reduced from 95 to 25, the median ACC ranged from 0.96 to 0.91 for the CNN, but 0.93 to 0.77 for the MSMT‐CSD (with perfect score of 1). The angular error in the typical regions of interest (ROIs) was also much lower, especially in multi‐fiber regions. The average MAE for the CNN method in regions containing one, two, three fibers was, respectively, 1.09°, 2.75°, and 8.35° smaller than the MSMT‐CSD method. The visual inception of the fODF further confirmed this superiority. Moreover, the tractography results validated the effectiveness of the learned fODF, in preserving known major branching fibers with only 25 DWIs.Conclusion: Experiments on HCP datasets demonstrated the feasibility of the proposed method in recovering fODFs from up to 11‐fold reduced number of DWIs. The proposed method offers a new streamlined reconstruction procedure and exhibits promising potential in acquisition acceleration for the reconstruction of fODFs with good accuracy.
- 22 April 2019
- Published by Wiley in Medical Physics
- Vol. 46 (7) , 3101-3116
Fast learning of fiber orientation distribution function for MR tractography using convolutional neural network
Purpose: In diffusion‐weighted magnetic resonance imaging (DW‐MRI), the fiber orientation distribution function (fODF) is of great importance for solving complex fiber configurations to achieve reliable tractography throughout the brain, which ultimately facilitates the understanding of brain connectivity and exploration of neurological dysfunction. Recently, multi‐shell multi‐tissue constrained spherical deconvolution (MSMT‐CSD) method has been explored for reconstructing full fODFs. To achieve a reliable fitting, similar to other model‐based approaches, a large number of diffusion measurements is typically required for MSMT‐CSD method. The prolonged acquisition is, however, not feasible in practical clinical routine and is prone to motion artifacts. To accelerate the acquisition, we proposed a method to reconstruct the fODF from downsampled diffusion‐weighted images (DWIs) by leveraging the strong inference ability of the deep convolutional neural network (CNN).Methods: The method treats spherical harmonics (SH)‐represented DWI signals and fODF coefficients as inputs and outputs, respectively. To compensate for the reduced gradient directions with reduced number of DWIs in acquisition in each voxel, its surrounding voxels are incorporated by the network for exploiting their spatial continuity. The resulting fODF coefficients are fitted with applying the CNN in a multi‐target regression model. The network is composed of two convolutional layers and three fully connected layers. To obtain an initial evaluation of the method, we quantitatively measured its performance on a simulated dataset. Then, for in vivo tests, we employed data from 24 subjects from the Human Connectome Project (HCP) as training set and six subjects as test set. The performance of the proposed method was primarily compared to the super‐resolved MSMT‐CSD with the decreasing number of DWIs. The fODFs reconstructed by MSMT‐CSD from all available 288 DWIs were used as training labels and the reference standard. The performance was quantitatively measured by the angular correlation coefficient (ACC) and the mean angular error (MAE).Results: For the simulated dataset, the proposed method exhibited the potential advantage over the model reconstruction. For the in vivo dataset, it achieved superior results over the MSMT‐CSD in all the investigated cases, with its advantage more obvious when a limited number of DWIs were used. As the number of DWIs was reduced from 95 to 25, the median ACC ranged from 0.96 to 0.91 for the CNN, but 0.93 to 0.77 for the MSMT‐CSD (with perfect score of 1). The angular error in the typical regions of interest (ROIs) was also much lower, especially in multi‐fiber regions. The average MAE for the CNN method in regions containing one, two, three fibers was, respectively, 1.09°, 2.75°, and 8.35° smaller than the MSMT‐CSD method. The visual inception of the fODF further confirmed this superiority. Moreover, the tractography results validated the effectiveness of the learned fODF, in preserving known major branching fibers with only 25 DWIs.Conclusion: Experiments on HCP datasets demonstrated the feasibility of the proposed method in recovering fODFs from up to 11‐fold reduced number of DWIs. The proposed method offers a new streamlined reconstruction procedure and exhibits promising potential in acquisition acceleration for the reconstruction of fODFs with good accuracy.