Víctor M. Rodríguez-Montaño
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Víctor M. Rodríguez-Montaño has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Juan Luis Beira-Jiménez
Acoustic Engineering Laboratory, Puerto Real Campus, Universidad de Cádiz, 11510 Puerto Real, Spain
2 shared publications - Ricardo Hernández-Molina
Department of Mechanical Engineering & Industrial Design, Faculty of Engineering, University of Cadiz, Av. University of Cadiz 10, 11519 Puerto Real, Spain
2 shared publications - Virginia Puyana-Romero
Departamento de Ingeniería en Sonido y Acústica, Universidad de Las Américas, Quito 17513, Ecuador
2 shared publications - David Bienvenido-Huertas
Department of Building Construction, University of Granada, 18071 Granada, Spain
1 shared publication F. Fernández Zacarías
1 shared publicationJ.L. Beira Jiménez
1 shared publication
Latest Publications
- Open Access
The Noise: A Silent Threat to the Recovery of Patients in Neonatal Intensive Care Units
The architectural configuration of the space plays a crucial role in the acoustics of neonatal intensive care units (NICUs). The design of the environment, the materials used in construction, and the organisation of noise sources within the room significantly influence the noise levels present in these critical areas. For this research, the noise levels found in two hospitals, with different architectural configurations and sizes but similar construction materials, have been analysed. Data were recorded at 1 s intervals over a period of more than 24 h. The data collected in these hospitals confirm the magnitude of the noise problem in NICUs, highlighting the urgent need to address it effectively to ensure an appropriate and safe environment for the recovery of neonates. Good architectural planning can help mitigate noise, while poor configuration can exacerbate acoustic problems, negatively affecting both patients and healthcare staff. It is crucial to involve architects, acoustic engineers, and healthcare staff in the design and renovation of NICUs to create spaces that not only meet medical needs but also consider the auditory well-being of neonates.
Open AccessThe Noise: A Silent Threat to the Recovery of Patients in Neonatal Intensive Care Units
The architectural configuration of the space plays a crucial role in the acoustics of neonatal intensive care units (NICUs). The design of the environment, the materials used in construction, and the organisation of noise sources within the room significantly influence the noise levels present in these critical areas. For this research, the noise levels found in two hospitals, with different architectural configurations and sizes but similar construction materials, have been analysed. Data were recorded at 1 s intervals over a period of more than 24 h. The data collected in these hospitals confirm the magnitude of the noise problem in NICUs, highlighting the urgent need to address it effectively to ensure an appropriate and safe environment for the recovery of neonates. Good architectural planning can help mitigate noise, while poor configuration can exacerbate acoustic problems, negatively affecting both patients and healthcare staff. It is crucial to involve architects, acoustic engineers, and healthcare staff in the design and renovation of NICUs to create spaces that not only meet medical needs but also consider the auditory well-being of neonates.
- Open Access
- 3 July 2024
- Published by MDPI AG in Preprints.org
The noise: a silent threat to the recovery of patients in Neonatal Intensive Care Units
The architectural configuration of the space plays a crucial role in the acoustics of Neonatal Intensive Care Units (NICUs). The design of the environment, the materials used in construction, and the organisation of noise sources within the room significantly influence the noise levels present in these critical areas. For this research, noise levels found in two hospitals, with different architectural configurations and sizes but similar construction materials, have been analyzed. Data were recorded at 1-second intervals over a period of more than 24 hours. The data collected in these hospitals confirm the magnitude of the noise problem in NICUs, highlighting the urgent need to address it effectively to ensure an appropriate and safe environment for the recovery of neonates. Good architectural planning can help mitigate noise, while poor configuration can exacerbate acoustic problems, negatively affecting both patients and healthcare staff. It is crucial to involve architects, acoustic engineers, and healthcare staff in the design and renovation of NICUs to create spaces that not only meet medical needs but also consider the auditory well-being of neonates.
- 3 July 2024
- Published by MDPI AG in Preprints.org
Open AccessThe noise: a silent threat to the recovery of patients in Neonatal Intensive Care Units
The architectural configuration of the space plays a crucial role in the acoustics of Neonatal Intensive Care Units (NICUs). The design of the environment, the materials used in construction, and the organisation of noise sources within the room significantly influence the noise levels present in these critical areas. For this research, noise levels found in two hospitals, with different architectural configurations and sizes but similar construction materials, have been analyzed. Data were recorded at 1-second intervals over a period of more than 24 hours. The data collected in these hospitals confirm the magnitude of the noise problem in NICUs, highlighting the urgent need to address it effectively to ensure an appropriate and safe environment for the recovery of neonates. Good architectural planning can help mitigate noise, while poor configuration can exacerbate acoustic problems, negatively affecting both patients and healthcare staff. It is crucial to involve architects, acoustic engineers, and healthcare staff in the design and renovation of NICUs to create spaces that not only meet medical needs but also consider the auditory well-being of neonates.
- 1 August 2020
- Published by Elsevier in Applied Acoustics
- Vol. 165
Characterizing the acoustic environment in a Neonatal Intensive Care Unit
- 1 August 2020
- Published by Elsevier in Applied Acoustics
- Vol. 165
Characterizing the acoustic environment in a Neonatal Intensive Care Unit