HNHidehisa Nishi

Hidehisa Nishi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hidehisa Nishi has a total of 257 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Automated perfusion imaging did not improve reliability of ASPECTS or collateral score in late-window large vessel occlusion stroke

    by Anass Benomar, Robert Fahed, Abdelsimar Tan Omar, Christine Hawkes, Eef J Hendriks, Clare A Enriquez, Muneer Eesa, Grant Stotts, Hubert Lee, Shashank Nagendra, et al.

    Background: The Alberta Stroke Program Early CT Score (ASPECTS) and CT angiography (CTA) Collateral Score (CS) are routinely used to estimate ischemic core burden and collateral status in acute ischemic stroke due to large vessel occlusion, but suffer from limited reliability. Whether automated CT perfusion (CTP) maps improve scoring consistency remains unclear. Objectives: To assess the reliability of these scores on non-contrast computed tomography (NCCT) and CTA among numerous raters, with and without access to automated perfusion maps, and their correlations with endovascular thrombectomy (EVT) decisions. Methods: Twenty-nine clinicians independently rated 60 imaging cases from 30 late-window stroke patients with large vessel occlusion, each presented twice: once using NCCT and CTA alone (‘non-CTP cases’), and once with the addition of perfusion maps (‘CTP cases’). Twenty-eight raters (97%) completed the survey twice. Inter- and intra-reliability was assessed using Gwet’s AC1/2 coefficients (κ G ). Correlations with EVT decisions were evaluated using Cramer V. Results: Inter-rater reliability for ASPECTS was substantial and similar between non-CTP (κ G = 0.65, 95% CI: 0.53 to 0.78) and CTP cases (κ G = 0.64, 95% CI: 0.51 to 0.77). CS showed an almost perfect reliability in both scenarios (κ G = 0.82 and 0.83). Intra-rater agreement was at least substantial. Dichotomizing ASPECTS as 0-2/3-10 improved reliability to almost perfect. ASPECTS strongly correlated with EVT decisions (V=0.80), whereas CS showed moderate correlation (V=0.56), both remaining similar with the addition of CTP (V=0.75 and 0.54, respectively). Conclusion: Automated perfusion imaging did not improve the reliability of ASPECTS or CS. Strong reliability was achieved with NCCT and CTA alone.

  • Open Access

    Automated detection of hyperdense artery sign on non-contrast CT for rapid identification of large vessel occlusion: a multicenter validation study

    by Hirofumi Tsuji, Akira Ishii, Hidehisa Nishi, Yu Abekura, Takuya Fuchigami, Atsushi Tachibana, Hirotaka Ito, Yoshiki Arakawa

    Purpose: Computed tomography angiography (CTA) is the gold standard for detecting large vessel occlusion, but its acquisition and reconstruction delay time-critical workflow. The hyperdense artery sign (HAS) on non-contrast CT (NCCT) offers an immediate, albeit subtle, marker. We developed a fully automated deep-learning model for HAS detection and evaluated its utility as an adjunctive pre-CTA alert to support earlier workflow readiness while confirmatory vascular imaging is pending. Furthermore, we assessed the radiological validity of the model’s detections to ensure they correspond to genuine thrombi rather than artifacts. Methods: We trained a 3-step deep-learning pipeline (midline correction, ischemic core segmentation, HAS segmentation) on 690 NCCT scans. Clinical validation was performed in two complementary cohorts: Part 1A, a multicenter CSC triage cohort ( n = 159) representing a workflow-enriched high-acuity setting, and Part 1B, a single-center consecutive all-comer suspected-stroke cohort ( n = 226) representing a broader real-world population. The primary metric was the Positive Predictive Value (PPV) to assess the reliability of the alert as a workflow-support role. Technical validation was performed using a crossover multi-reader study ( n = 10 specialists and residents) to evaluate whether AI-detected regions were radiologically perceivable by human readers. Results: In Part 1A, the model achieved a sensitivity of 76.2% (80/105), specificity of 87.0% (47/54), accuracy of 79.9% (127/159), and PPV of 92.0% (80/87), indicating high reliability of positive alerts in a CSC triage setting. In Part 1B, the model achieved a sensitivity of 74.3% (26/35), specificity of 82.7% (158/191), PPV of 44.1% (26/59), NPV of 94.6% (158/167), and accuracy of 81.4% (184/226), reflecting preserved discrimination in a lower-prevalence, broader real-world population. In the reader study, model assistance significantly improved HAS-detection performance, increasing JAFROC Figure of Merit from 0.71 to 0.77 ( p < 0.01). Conclusion: The proposed model enables rapid HAS detection on NCCT and demonstrated complementary performance across two validation settings: high reliability of positive alerts in a workflow-enriched CSC triage cohort and preserved sensitivity/specificity in a broader consecutive cohort. These findings support its role as an adjunctive pre-CTA alert for earlier workflow readiness in high-probability settings, not as a stand-alone rule-out tool. The observer study further supports the radiological validity of the AI-highlighted regions.

  • Open Access

    Bioresorbable magnesium flow diverter promotes early aneurysm occlusion in rabbits

    by So Matsukawa, Akira Ishii, Ryo Akiyama, Natsuhi Sasaki, Hidehisa Nishi, Hideo Chihara, Tomoko Hayashi, Yoshihito Kawamura, Shinichi Yagi, Shin-Ichi Inoue, et al.

    Background: Bioresorbable flow diverters (BRFDs) may overcome the limitations of permanent flow diverters (FDs). We developed a long period stacking ordered-type magnesium (Mg) alloy with superior strength, processability, and corrosion resistance using rapidly solidified powder metallurgy. Thin Mg wires were coated with poly L-lactic acid (PLLA) by electrospinning to extend bioresorption, and braided into 48 wire Mg-BRFDs. Methods: We compared mechanical properties, angiographic outcomes, and biological responses of Mg-BRFDs with cobalt–chromium/platinum–tungsten FDs (CoCr-FDs) in a rabbit elastase induced aneurysm model and abdominal aorta. Assessments included angiography, optical coherence tomography, scanning electron microscopy, and histopathology at 0.5, 1, and 3 months. Results: Mg-BRFDs had a mean strut diameter of 56 µm (including a 10 µm PLLA coating), porosity of 53.9%, and pore density of 23 pores/mm². Complete occlusion rates in CoCr-FDs were 20% (1/5), 0% (0/7), and 57% (4/7) at 0.5, 1, and 3 months, respectively; corresponding rates with Mg-BRFDs were 50% (3/6), 75% (6/8), and 100% (8/8). Among cases with incomplete occlusion, neointimal coverage rate of the aneurysm neck was significantly greater with Mg-BRFDs (median 70.2% vs 26.1%, P=0.006). No occlusion of side branches covered by FDs occurred in either group. Neointimal ionized calcium binding adapter molecule 1 (Iba-1) positive cell counts were higher with Mg-BRFDs but declined over time (P=0.0003). Conclusions: Mg-BRFDs promoted early neointimal formation during bioresorption, leading to faster and more complete aneurysm occlusion than CoCr-FDs. These findings demonstrate the feasibility of Mg-BRFDs as a promising next generation therapeutic strategy.


  • Open Access

    Flow Diversion in Fetal-Type Posterior Communicating Artery Aneurysms: Anatomical Challenges and Treatment Strategy

    by Hidehisa Nishi, Akira Ishii

    Fetal-type posterior communicating artery (PcomA) aneurysms remain a difficult subgroup in the flow-diverter era. In these lesions, the PcomA supplies a substantial portion of the posterior cerebral artery territory because the ipsilateral P1 segment is absent, hypoplastic, or functionally insufficient. The branch therefore functions as a major outflow channel, and persistent distal demand may maintain circulation through the aneurysm–neck complex after flow diversion.

  • Human versus machine: are neurointerventionists more precise in manual or robotically assisted procedures?

    by Guillaume Charbonnier, Nicole M Cancelliere, Arturo Consoli, Hidehisa Nishi, Kevin Janot, Ze’EV Itsekson Hayosh, Ange Diouf, Aruma Jiménez-O’SHanahan, Zamir Merali, Thomas R Marotta, et al.

    Background Robotic neurointerventions have demonstrated promising initial clinical results. Claims of enhanced precision during robotic navigation have been reported, but objective quantification of such precision is limited. Precision during intracranial navigation and device deployment is crucial in neurovascular interventions, and lack of precision can lead to intraprocedural complications. This study compared quantitative metrics of precision in manual and robotic procedures using a virtual simulator. Methods Using three different simulated aneurysm procedures with different levels of difficulty (easy, medium, and hard), 12 operators with different levels of experience were assigned a defined task for each case. Each procedure was performed both manually and under robotic assistance. Precision was assessed using the length of translations and the total degree of rotations of the microwire and microcatheter needed to complete the assigned tasks, as well as recorded safety metrics. Results were compared between the manual and robotic groups. Results We analyzed 78 procedures (robotic, n=34; manual, n=34) performed by 12 operators with various levels of neurointerventional surgical experience (high, n=5; low, n=7). For the difficult case, operators used significantly less microwire translations when operating with robotic assistance (38.7 cm vs 108.4 cm, P=0.023). There were no significant differences for the easy and medium cases. Safety metrics and procedural times were not significant different. Conclusions Operators demonstrated increased precision during microwire navigation when using robotic assistance to navigate a difficult aneurysm in a controlled simulated experimental set-up compared with manual navigation.

  • Open Access

    Magnesium-based bioresorbable flow diverter for intracranial aneurysms: a pilot study of biocompatibility and bioresorption in a rabbit vascular model

    by Ryo Akiyama, Akira Ishii, Natsuhi Sasaki, So Matsukawa, Shinichi Yagi, Hideo Chihara, Hidehisa Nishi, Kiyotaka Iwasaki, Shinichi Sakurai, Yoshihito Kawamura, et al.

    Background: Bioresorbable flow diverters (BRFDs) have the potential to solve several problems associated with conventional permanent flow diverters. We have constructed bare and poly-L-lactic acid (PLLA)-coated magnesium BRFDs (MgBRFDs) using a high-strength corrosion-resistant magnesium alloy. This study aimed to compare bioresorption and biocompatibility between the two types in a rabbit vascular model to determine which is more clinically feasible in humans. Methods: Bare and PLLA-coated MgBRFDs were fabricated by braiding 48 thin magnesium alloy wires. Mechanical testing was conducted. Bare (n=13) and PLLA-coated (n=13) MgBRFDs were implanted into rabbit aortas and harvested 14, 30, and 90 days after implantation. The physical structure of the resolution process was examined using optical coherence tomography (OCT), micro-computed tomography, and scanning electron microscopy (SEM). The biological response of the vascular tissue was examined using SEM and histopathological analysis. Results: The porosity and pore density of the bare MgBRFD were 64% and 16 pores/mm 2 , respectively; corresponding values for the PLLA-coated MgBRFD were 63% and 12 pores/mm 2 , respectively. The OCT attenuation score was significantly higher for the PLLA-coated MgBRFD at all time points (14 days, P=0.01; 30 days, P=0.02; 90 days, P=0.004). OCT, micro-computed tomography, and SEM demonstrated better stent structure preservation with the PLLA-coated MgBRFD. Neointimal thickness did not significantly change over time in either type of MgBRFD (bare, P=0.93; PLLA-coated, P=0.34); however, the number of inflammatory and proliferative cells peaked at 14 days and then decreased. Conclusions: Both bare and PLLA-coated MgBRFDs had excellent biocompatibility. The PLLA-coated MgBRFD has greater clinical feasibility because of its delayed bioresorption.


  • Open Access

    Development and Validation of Automated Software for the Detection of Large Vessel Occlusion on Noncontrast CT

    by Hirofumi Tsuji, Akira Ishii, Yu Abekura, Hidehisa Nishi, Takuya Fuchigami, Atsushi Tachibana, Hirotaka Ito, Yoshiki Arakawa

    Background Reliable detection of large-vessel occlusion (LVO) via medical-image analysis has significant advantages in cases of acute ischemic stroke (AIS). In recent years, convolutional neural network (CNN)-based technologies for automated LVO detection have been developed. However, the pros and cons of CNN-based assistance in clinical practice remain poorly understood. The purpose of this study was to develop and validate a deep learning-based model to detect the hyperdense-artery sign (HAS) as a proxy for LVO and to investigate its impact on neurosurgeons’ diagnostic accuracy. Methods We conducted a multicenter, retrospective study of patients with LVO due to anterior-circulation AIS who underwent computed tomography angiography or magnetic resonance angiography on admission, as well as patients without LVO (patients with no indicative angiography features and patients with cerebral infarction without LVO), who were admitted from 2006 to 2022. A CNN algorithm for LVO detection was developed using data from four institutions (n=690), and model performance was validated using data from five institutions (n=129). For further investigation, five board-certified and five non-board-certified neurosurgeons performed two separate observer-performance studies with a 4-week interval, with and without the CNN for each image. Results The HAS was detected in the correct location with a sensitivity and specificity of 0.79 and 0.87 by the CNN, 0.61 and 0.60 by board-certified neurosurgeons, and 0.61 and 0.66 by non-board-certified neurosurgeons, respectively. With the CNN, the mean area under the curve and figure of merit significantly increased for all readers (from 0.72 to 0.81, pConclusions Our deep learning-based automated LVO-detection model for non-contrast-enhanced computed tomographic images significantly improved neurosurgeons’ diagnostic performance. Further studies are needed to clarify the usefulness of the CNN in clinical practice.

  • Volumetric microscopy of cerebral arteries with a miniaturized optical coherence tomography imaging probe

    by Vitor M. Pereira, Pedro Lylyk, Nicole Cancelliere, Pedro N. Lylyk, Ivan Lylyk, Vania Anagnostakou, Carlos Bleise, Hidehisa Nishi, Mark Epshtein, Robert M. King, et al.

    Endovascular interventions are increasingly becoming the preferred approach for treating strokes and cerebral artery diseases. These procedures rely on sophisticated angiographical imaging guidance, which encounters challenges because of limited contrast and spatial resolution. Achieving a more precise visualization of the underlying arterial pathology and neurovascular implants is crucial for accurate procedural decision-making. In a human study involving 32 patients, we introduced the clinical application of a miniaturized endovascular neuro optical coherence tomography ( n OCT) imaging probe. This technology was designed to navigate the tortuous paths of the cerebrovascular circulation and to offer high-resolution imaging in situ. The n OCT probe is compatible with standard neurovascular microcatheters, integrating with the procedural workflow used in clinical routine. Equipped with a miniaturized optical fiber and a distal lens, the probe illuminates the tissue and collects the backscattered, near-infrared light. While rotating the fiber and the lens at high speed, the probe is rapidly retracted, creating a spiral-shaped light pattern to comprehensively capture the arterial wall and implanted devices. Using n OCT, we demonstrated volumetric microscopy of cerebral arteries in patients undergoing endovascular procedures. We imaged the anterior and posterior circulation of the brain, including distal segments of the internal carotid and middle-cerebral arteries, as well as the vertebral, basilar, and posterior cerebral arteries. We captured a broad spectrum of neurovascular pathologies, such as brain aneurysms, ischemic stroke, arterial stenoses, dissections, and intracranial atherosclerotic disease. n OCT offered artifact-free, high-resolution visualizations of intracranial artery pathology and neurovascular devices.


  • Novel, braided, self-expandable stent designed for the treatment of pulsatile tinnitus caused by intracranial venous stenosis: first-in-human experience and long-term outcomes

    by Arturo Consoli, Nicole M Cancelliere, Guillaume Charbonnier, Hidehisa Nishi, Irene Vanek, Thomas R Marotta, Julian Spears, Vitor M Pereira

    Background Pulsatile tinnitus (PT) can be a disabling clinical condition, which may be caused by a sigmoid/transverse sinus stenosis (STSS). Intracranial venous stenting with off-label carotid or peripheral venous stents has been used successfully to treat this condition. We present the results of a cohort of patients presenting with PT treated with a novel, dedicated, braided stent for the endovascular treatment of STSS. Methods Twelve patients presenting with PT and associated STSS were treated at our institution (December 2022–June 2023). All clinical and procedural variables were prospectively collected. We used the Tinnitus Function Index (TFI) and the Tinnitus Handicap Inventory (THI) scores to assess the impact of PT on quality of life before and after the treatment (mean follow-up: 10.3 months). Results Twelve women (mean age: 44±16.5 years) presenting with PT and STSS were treated. Mean pretreatment TFI/THI scores were 78.8/77. The BosStent was successfully deployed in all patients. We experienced no intraprocedural/postoperative complications. Intra-stent angioplasty was performed in three cases. All patients reported a complete resolution of PT symptoms within 1 month and remained stable and PT-free at the last follow-up (mean posttreatment TFI/THI score: 7.1/5, pConclusions The BosStent was successfully used in a cohort of patients with PT without any intraprocedural complications. All the patients experienced a complete resolution of PT symptoms after 1 month, which was stable during the follow-up period. Further studies with larger populations will be necessary to investigate the safety and effectiveness of this novel stent for the treatment of PT with STSS.


  • Clinical uncertainty in large vessel occlusion ischemic stroke: does automated perfusion imaging make a difference? An intra-rater and inter-rater agreement study

    by Jose Danilo Bengzon Diestro, Robert Fahed, Abdelsimar Tan Omar, Christine Hawkes, Eef J Hendriks, Clare Enriquez, Muneer Eesa, Grant Stotts, Hubert Lee, Shashank Nagendra, et al.

    Background: Limited research exists regarding the impact of neuroimaging on endovascular thrombectomy (EVT) decisions for late-window cases of large vessel occlusion (LVO) stroke.Objective: T0 assess whether perfusion CT imaging: (1) alters the proportion of recommendations for EVT, and (2) enhances the reliability of EVT decision-making compared with non-contrast CT and CT angiography.Methods: We conducted a survey using 30 patients drawn from an institutional database of 3144 acute stroke cases. These were presented to 29 Canadian physicians with and without perfusion imaging. We used non-overlapping 95% confidence intervals and difference in agreement classification as criteria to suggest a difference between the Gwet AC1 statistics (κG).Results: The percentage of EVT recommendations differed by 1.1% with or without perfusion imaging. Individual decisions changed in 21.4% of cases (11.3% against EVT and 10.1% in favor). Inter-rater agreement (κG) among the 29 raters was similar between non-perfusion and perfusion CT neuroimaging (κG=0.487; 95% CI 0.327 to 0.647 and κG=0.552; 95% CI 0.430 to 0.675). The 95% CIs overlapped with moderate agreement in both. Intra-rater agreement exhibited overlapping 95% CIs for all 28 raters. κGwas either substantial or excellent (0.81–1) for 71.4% (20/28) of raters in both groups.Conclusions: Despite the minimal difference in overall EVT recommendations with either neuroimaging protocol one in five decisions changed with perfusion imaging. Regarding agreement we found that the use of automated CT perfusion images does not significantly impact the reliability of EVT decisions for patients with late-window LVO.