JWJeffrey Wensman

Jeffrey Wensman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jeffrey Wensman has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effects of adjustable‐volume transfemoral prosthetic sockets on balance and falls: A randomized clinical trial

    by Deanna H. Gates, Jeffrey Wensman, Anthony R. Gutierrez, Jordan Kartes, Marco A. Avalos, Jenevieve A.W. Surkin, Noah J. Rosenblatt

    Background: Adjustable‐volume prosthetic sockets have been developed to allow users to accommodate volume fluctuations throughout the day. Improvement in socket fit is thought to enhance the connection between the user's residual limb and prosthesis and may therefore improve postural control and balance. However, no studies have assessed balance‐related outcomes or falls between different adjustable socket designs. Objective: To compare balance‐related outcomes for people with transfemoral limb loss using three styles of adjustable‐volume sockets and a laminated socket. Design: Randomized clinical trial. Setting: Prosthetics clinics and research laboratories. Participants: A convenience sample of 29 individuals with unilateral transfemoral amputation were recruited, of whom 23 completed testing in at least one adjustable‐volume socket and were included. Intervention: Participants completed four 4‐week trials with each of three adjustable‐volume prosthetic sockets and a laminated socket, in random order. Adjustable‐volume sockets included Infinite (LIM Innovations, San Francisco, CA, USA), CJ (CJ Sockets Technologies, Beverly, MA, USA), and Quatro (Quorum, Windsor, CO, USA). Main Outcome Measures: The primary outcomes were self‐reported balance, number of falls and stumbles, and balance confidence. Secondary outcomes included the Narrow Beam Walk Test (NBWT) and Timed Up and Go Test (TUG). Surveys were conducted after at least 3 weeks of use of each socket, and functional measures were collected after 4 weeks. Results: There were no main effects of socket type on self‐reported balance ( p = .316), balance confidence ( p = .963), NBWT ( p = .159), or TUG ( p = .581). Eighteen participants (78%) reported falling or stumbling at least once in a 3‐week period in at least one socket condition. There were no differences in the proportion of fallers (1+ falls) or stumblers (1+ stumbles) between the laminated condition and any adjustable‐socket condition ( p > .210). Conclusions: The adjustable‐volume prosthetic sockets tested demonstrated comparable performance to laminated sockets for balance and fall‐related outcomes. The high number of falls and stumbles reported suggests that future studies should focus on balance and falls training, acknowledging that changes to the socket may be insufficient to address this issue.

  • Open Access

    The clinical effects of the Össur Power Knee with phase-based and default control during sitting, standing, and walking

    by T. Kevin Best, C. Andrew Seelhoff, Jeffrey Wensman, Robert D. Gregg

    Background: A lack of evidence of compelling clinical benefits is a key factor limiting the adoption of commercialized powered robotic knee prostheses into mainstream clinical practice. Previous studies have demonstrated mixed results, potentially due to a combination of limitations in prosthetic hardware, control algorithms, and testing methodologies. Methods: We investigated the clinical effects of a commercialized robotic knee prosthesis (the latest generation Össur Power KneeTM) with n=7 above-knee amputee participants. Participants with both higher (K4) and lower mobility (K3) completed a series of experiments including repeated sitting and standing, a stand, walk, sit shuttle test, and fast walking on a treadmill. We tested both standard (ÖSSR) and novel (HKIC) control policies and compared the resulting clinical metrics to those found with the users’ prescribed passive prostheses. Our experiments were physically demanding, which could help elucidate the potential benefits of powered knees. Results: The clinical effects of the Power Knee varied with mobility level and the control policy used. The phase-based controller often produced stronger walking and sit/stand improvements for the higher mobility group compared to the default controller, though it also presented a steeper learning curve and reduced walk-to-sit transition speed. Conversely, the default control policy was perceived as easier to master but was less assistive to the higher mobility group and produced slower sit/stand cycles. Lower mobility participants experienced improvements in standing speed (HKIC: $$36.7\pm 15.1$$ % faster, $$p<0.001$$ ; ÖSSR: $$28.8\pm 15.1$$ % faster, $$p=0.001$$ ), inter-limb ground reaction force symmetry (HKIC: $$-0.214\pm 0.068$$ , $$p<0.001$$ ; ÖSSR: $$-0.199\pm 0.068$$ , $$p<0.001$$ ), and inter-limb peak knee moment symmetry (HKIC: $$-0.290\pm 0.126$$ , $$p<0.001$$ ; ÖSSR: $$-0.284\pm 0.126$$ , $$p<0.001$$ ) during sit-to-stand tasks relative to their passive prostheses. In contrast, higher mobility participants benefited less in sit/stand but showed improvements while walking including increased toe clearance (HKIC: $$25.4\pm 12.2$$ mm, $$p<0.001$$ ; ÖSSR: $$13.4\pm 12.2$$ mm, $$p=0.033$$ ), greater early stance knee flexion (HKIC: $$7.1\pm 2.9^\circ $$ , $$p<0.001$$ ; ÖSSR: $$4.5\pm 2.9^\circ $$ , $$p=0.005$$ ), and, for the HKIC policy, a reduced swing-phase peak hip flexion moment (HKIC: $$-0.18\pm 0.11$$ Nm/kg/(m/s), $$p=0.003$$ ). Despite these biomechanical improvements and qualitative reports of reduced effort, neither control policy produced significant benefits in endurance or repeated task performance compared to the passive condition. Sit-to-stand cycle count in the lower mobility group was unchanged (HKIC: $$p=0.268$$ , ÖSSR: $$p=0.848$$ ), and it was reduced in the higher mobility group with the ÖSSR condition ( $$2.0\pm 1.4$$ fewer, $$p=0.007$$ ). In the shuttle walk test, laps completed by higher mobility users decreased with HKIC ( $$157.3\pm 46.3$$ fewer, $$p<0.001$$ ), and no significant differences were found for lower mobility users. No significant changes in fast walking distance or speed were observed across conditions. Conclusions: The latest generation Power Knee can create clinical improvements in walking and sit/stand behaviors compared to passive (microprocessor) knees, though the effects are sensitive to the user’s mobility level and the Power Knee’s control policy. However, these improvements did not directly translate to improved functional performance or endurance. Some negative effects of the Power Knee were also observed including reduced agility, slower transitions, and thermal limitations, though some of these limitations could potentially be addressed through future control innovations or with more thorough acclimation. The observed benefits motivate future longitudinal studies to investigate the clinical effects of robotic knees compared to passive (microprocessor) knees in real-world settings and to elucidate how they could be best utilized in clinical practice. Trial Registration: The experimental protocol was approved by the University of Michigan Institutional Review Board (HUM00230065) on February 9th, 2024. The trial is registered with the National Institutes of Health under ClinicalTrials.gov ID NCT06138977.


  • Design of a segmented custom ankle foot orthosis with custom-made metal strut and 3D-printed footplate and calf shell

    by Miguel A. Funes-Lora, Ryan Posh, Jeffrey Wensman, Albert J. Shih

    Background: 3D-printing is a potential manufacturing process for optimizing the design and manufacture of ankle foot orthosis (AFOs). The feasibility of an AFO with interchangeable strut that is suitable for 3D-printing is created and evaluated. Objective: A segmented AFO with 3D-printed custom footplate and calf shell connected by a custom-made strut is studied. Study design: The duration of a healthy subject wearing the 3D-printed segmented AFO in daily activities is used to evaluate the feasibility and durability to integrate 3D-printed AFOs into orthotics practice. Technique: The 3D-scanning of a patient's leg is first conducted. The scanned 3D surface is modified by creating the clearance around bony prominences and trimlines for the footplate and calf shell. The footplate has a custom-shaped inside to match with the foot and a standard shape outside at the top to match and connect with the strut. For the calf shell, the inside shape is custom fit with the shank and the outside shape is standard to connect with the strut. Material extrusion is the 3D-printing process selected. Tree-like support structures are used to avoid the use of soluble support material and to eliminate the risk of residual chemical solvent in the orthosis. Results: The segmented AFO with material extrusion footplate and calf shell was tested in a healthy subject with an active lifestyle, offering comfort, and stability for over 4 months without breakage. Conclusions: This segmented AFO is durable, requires short 3D-printing time, and enables the quick adjustment of bending stiffness via an interchangeable strut design.


  • A controlled clinical trial of a clinically-tuned powered ankle prosthesis in people with transtibial amputation

    by Emily S Gardinier, Brian M Kelly, Jeffrey Wensman, Deanna H Gates

    To determine whether there are changes in level walking performance for people using a powered ankle prosthesis that was tuned by an independent, manufacturer-certified prosthetist in accordance with device recommendations. Intervention study with cross-over design. Laboratory. Convenience sample of 10 individuals with unilateral, transtibial amputation, and 10 age- and gender-matched control participants. Powered ankle prosthesis (BiOM T2 Ankle System). Metabolic costs of walking, preferred walking speed. There were no significant differences in oxygen consumption (2.9% difference; P = 0.606, d = 0.26), cost of transport (~1% difference; P = 0.652, d = 0.23), or preferred walking speed (~1% difference; P = 0.147, d = 0.76) when using the powered ankle compared to unpowered prostheses. Secondary analyses of user characteristics revealed that participants who were classified as having the highest function (K4 on Medicare’s 5-point scale from K0 to K4) were significantly more likely to exhibit energy cost savings than those classified as having lower function (K3; P = 0.014, d = 2.36). Participants did not demonstrate significant improvements in energetics or preferred speed when wearing a clinically tuned powered ankle prosthesis compared to their non-powered prostheses. Prescribers of powered devices should understand that not all users will show an immediate reduction in energy expenditure.


  • Open Access

    Locomotor Adaptation by Transtibial Amputees Walking With an Experimental Powered Prosthesis Under Continuous Myoelectric Control

    by Stephanie Huang, Jeffrey P. Wensman, Daniel P. Ferris

    Lower limb amputees can use electrical activity from their residual muscles for myoelectric control of a powered prosthesis. The most common approach for myoelectric control is a finite state controller that identifies behavioral states and discrete changes in motor tasks. An alternative approach to state-based myoelectric control is continuous proportional myoelectric control where ongoing electrical activity has a proportional relationship to the prosthetic joint torque or power. To test the potential of continuous proportional myoelectric control for powered lower limb prostheses, we recruited five unilateral transtibial amputees to walk on a treadmill with an experimental powered prosthesis. Subjects walked using the powered prosthesis with and without visual feedback of their control signal in real time. Amputee subjects were able to adapt their residual muscle activation patterns to alter prosthetic ankle mechanics when we provided visual feedback of their myoelectric control signal in real time. During walking with visual feedback, subjects significantly increased their peak prosthetic ankle power ( p = 0.02, ANOVA) and positive work ( p = 0.02, ANOVA) during gait above their prescribed prosthesis values. However, without visual feedback, the subjects did not increase their peak ankle power during push off. These results show that amputee users were able to volitionally alter their prosthesis mechanics during walking, but only when given an explicit goal for their residual muscle motor commands. Future studies that examine the motor and learning capabilities of lower limb amputees using their residual muscles for continuous proportional myoelectric control are needed to determine the viability of integrating continuous high-level control with existing finite state prosthetic controllers.


  • Open Access

    A Novel Shear Reduction Insole Effect on the Thermal Response to Walking Stress, Balance, and Gait

    by James S. Wrobel, Peethambaran Ammanath, Tima Le, Christopher Luring, Jeffrey Wensman, Gurtej S. Grewal, Bijan Najafi, Rodica Pop-Busui

    Shear stresses have been implicated in the formation of diabetes-related foot ulcers. The aim of this study was to evaluate the effect of a novel shear-reducing insole on the thermal response to walking, balance, and gait. Twenty-seven diabetes peripheral neuropathy patients were enrolled and asked to take 200 steps in both intervention and standard insoles. Thermal foot images of the feet were taken at baseline (1) following a 5-minute temperature acclimatization and (2) after walking. Testing order was randomized, and a 5-minute washout period was used between testing each insole condition. Sudomotor function was also assessed. Gait and balance were measured under single and dual task conditions using a validated body worn sensor system. The mean age was 65.1 years, height was 67.3 inches, weight was 218 pounds, and body mass index was 33.9, 48% were female, and 82% had type 2 diabetes. After walking in both insole conditions, foot temperatures increased significantly in standard insoles. The intervention insole significantly reduced forefoot and midfoot temperature increases (64.1%, P = .008; 48%, P = .046) compared to standard insoles. There were significant negative correlations with sudomotor function and baseline temperatures (r = .53-.57). The intervention demonstrated 10.4% less gait initiation double support time compared to standard insoles (P = .05). There were no differences in static balance measures. We found significantly lower forefoot and midfoot temperature increases following walking with shear-reducing insoles compared to standard insoles. We also found improvements in gait. These findings merit future study for the prevention of foot ulcer.


  • An Experimental Powered Lower Limb Prosthesis Using Proportional Myoelectric Control

    by Stephanie Huang, Jeffrey P. Wensman, Daniel P. Ferris

    One way to provide powered lower limb prostheses with greater adaptability to a wearer's intent is to use a neural signal to provide feedforward control of prosthesis mechanics. We designed and tested the feasibility of an experimental powered ankle-foot prosthesis that uses pneumatic artificial muscles and proportional myoelectric control to vary ankle mechanics during walking. The force output of the artificial plantar flexor muscles was directly proportional to the subject's residual gastrocnemius muscle activity. The maximum force generated by a pair of artificial muscles fixed at nominal length was 3513 N. The maximum planter flexion torque that could be generated during walking was 176 Nm. The force bandwidth of the pneumatic artificial muscles was 2 Hz. The electromechanical delay was 33 ms, the time to peak tension was 48 ms, and the half relaxation time was 50 ms. We used two artificial muscles as dorsiflexors and two artificial muscles as plantar flexors. The prosthetic ankle had 25 deg of dorsiflexion and 35 deg of plantar flexion with the artificial muscles uninflated. The intent of the device was not to create a commercially viable prosthesis but to have a laboratory prototype to test principles of locomotor adaptation and biomechanics. We recruited one unilateral transtibial amputee to walk on a treadmill at 1.0 m/s while wearing the powered prosthesis. We recorded muscle activity within the subject's prescribed prosthetic socket using surface electrodes. The controller was active throughout the entire gait cycle and did not rely on detection of gait phases. The amputee subject quickly adapted to the powered prosthesis and walked with a functional gait. The subject generated peak ankle power at push off that was similar between amputated and prosthetic sides. Our results suggest that amputees can use their residual muscles for proportional myoelectric control to alter prosthetic mechanics during walking.