JSJussiane Souza Silva

Jussiane Souza Silva

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jussiane Souza Silva has a total of 79 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Signal-Analytics Modeling of Fluorescence Maximum Time-to-Detection (TTD+) for E. coli in Treated Wastewater: A Joint Censoring and Sensor Model Approach Part II

    by Charles Andre Haab, Jussiane Souza Silva, Thiago Alexandro Nascimento de Andrade, Frank Gomes-Silva, Adriano Marques Jaime, MaírA Casali Malonn, Vandré Sonza Pinto, Darliana Mello Souza, Leandro Michels

    Water security is a global priority and relies on reliable microbiological monitoring in treated effluents. In this work, we investigate a sensor-analytics component of Escherichia coli (E. coli) monitoring in treated wastewater through fluorescence time courses acquired with a miniaturized, Internet of Things-enabled incubation platform, named the Optical Bacterial Growth Sensor–Fluorescence Detector. The signal arises from hydrolysis of a β-d-glucuronide substrate mediated by E. coli-expressed β-glucuronidase activity, yielding characteristic kinetic profiles over time. Our primary target is the extraction and probabilistic modeling of the upper time-to-detection, TTD+, an operational timing feature of the recorded fluorescence response. In practical terms, TTD+ retrospectively identifies the onset of the upper stable signal region under the adopted criterion, providing a timing summary for assay duration planning. To model this time-domain boundary, we adopt the Joint Censoring and Sensor Model Approach (JCSMA) and further extend it by deriving analytical expressions for ordinary moments and entropy measures, including Rényi and Shannon entropies. The empirical comparison favors JCSMA within the evaluated model set, while simulation characterizes the sampling behavior of selected statistics under the fitted model. The resulting probabilities and quantiles provide summaries for assay duration planning under the adopted conditions. The study does not evaluate analytical figures of merit for E. coli quantification or the association between TTD+ and reference most probable number values.

  • Open Access

    Signal-Analytics Modeling of Fluorescence Time-to-Detection for E. coli in Treated Wastewater: A Joint Censoring and Sensor Model Approach

    by Charles Andre Haab, Jussiane Souza Silva, Thiago Alexandro Nascimento de Andrade, Maria Clara Bohn Silva, Geovana Mussato Mello, Darliana Mello Souza, Adriano Marques Jaime, Vandré Sonza Pinto, Caroline Pinto Rangel, Tiago Batista Tonon, et al.


  • Feasibility of rare earth element determination in edible insects by USN-ICP-MS after microwave-assisted UV digestion using diluted acids

    by João L. K. Rocha, Gustavo Gohlke, Thiago C. Pereira, Alessandra S. Henn, Fabio A. Duarte, Jussiane S. Silva, Erico M. M. Flores

    A microwave-assisted ultraviolet digestion method with diluted acids was proposed for the subsequent determination of rare earth elements in edible crickets by inductively coupled plasma mass spectrometry with ultrasonic nebulization.


  • Open Access

    Feasibility for Real-Time Monitoring of Bacterial Growth in Raw Milk Using a New Contactless Sensor

    by Charles A. Haab, Jussiane S. Silva, Adriano M. Jaime, Vandré S. Pinto, Geovana M. Mello, Darliana M. Souza, Juliano S. Barin, Cristiano R. Menezes, Leandro Michels

    A novel method was developed for real-time quantification of the total bacterial count in raw milk using an electrical bacterial growth sensor based on a capacitively coupled contactless resonance frequency detector. The proposed method continuously monitors changes in the resonance frequency induced by bacterial metabolic activity, allowing for the construction of growth curves without requiring sample pretreatment or reagent addition. Growth curve analysis was performed using the Gompertz model, and the inflection point (β) was used to construct a predictive model for determining the total bacterial count. A total of 55 raw milk samples were used for the predictive model and application of the proposed method, which were compared to the standard plate count reference method. The predictive model demonstrated a good coefficient of determination (R2 = 0.75). A comparative analysis between the proposed and reference methods showed no significant difference (t-test, 95% confidence level). The proposed method presented a limit of detection of 2.40 log CFU mL-1. The results also demonstrate that the proposed method presents a higher greenness score (score = 0.75) compared to the reference method (score = 0.39) and that the analysis time could be reduced from 48 to 8 h to classify the raw milk according to Normative Instruction No. 55/2020. These findings highlight the feasibility of the proposed method for rapid, green, and real-time monitoring of bacterial growth, allowing a promising alternative to microbiological quality control in the dairy industry.


  • Mercury Determination at Ultra-trace Level in Eye Shadow by a New Electrothermal Vaporization System Coupled to ICP-MS

    by Jussiane Silva, Alessandra Henn, Geovana Mello, Valderi Dressler, Erico Flores

    Solid sampling-electrothermal vaporization inductively coupled plasma mass spectrometry (SS-ETV-ICP-MS) was proposed for ultra-trace determination of Hg in eye shadow samples. The ETV system was optimized using a heating program, consisting of drying at 80 °C for 20 s and vaporization at 800 °C for 10 s, followed by cooling for 120 s, without a pyrolysis step. The carrier gas flow rate was set to 1.10 L min-1, and sample mass up to 4 mg was analyzed. An alternative external calibration strategy using a standard solution of Hg and magnesium silicate for matrix matching demonstrated good linearity (R2 0.9983) in the range of 5 to 100 pg of Hg. Magnesium silicate enhances analyte transport and acts as a modifier, enabling calibration with aqueous standard solutions and presenting an alternative to certified reference material (CRM). Despite the differences in signal profiles for Hg observed in the eye shadow samples, CRM MESS-3 (Marine Sediment), and the standard solution, the method has good accuracy when the signal was integrated using peak area. Compared to cold vapor inductively coupled plasma mass spectrometry, which needs acid digestion and a ten-fold dilution with a limit of quantification (LOQ) of 0.1 µg g-1 Hg, the SS-ETV-ICP-MS provided a significantly lower LOQ (0.001 µg g-1) and a simplified analytical approach for Hg determination. This approach presents a practical alternative for determining Hg in eye shadows at ultra-trace levels.


  • Contactless Electrical Sensor Based on Resonance Frequency for Real-Time Monitoring of Bacterial Growth

    by Charles A. Haab, Adriano M. Jaime, Jussiane S. Silva, Thaiane M. Silva, Vandré S. Pinto, Juliano S. Barin, Cristiano R. Menezes, Julio Viégas, Leandro Michels

    An electrical sensor based on a capacitively coupled contactless resonance frequency detector (RFD) was developed for real-time monitoring of bacterial growth. The electrical bacterial growth sensor (EBGS) uses capacitively coupled electrodes to a glass tube containing the sample. This configuration makes it possible to detect variations in the resonance frequency caused by biochemical changes in the sample. The circuit induces an oscillation at the resonant frequency of an inductor-capacitor circuit coupled to the sample. The frequency is measured using a simple digital frequency meter without requiring an analog-to-digital converter. The proposed EBGS-RFD sensor presented a high gain in signal magnitude by operating at a resonance frequency compared to the EBGS sensor, which used a fixed frequency. Thus, a better signal-to-noise ratio was obtained and allowed the acquisition of high-quality electrical data. Furthermore, the proposed EBGS-RFD presented a straightforward electronic design compared to other EBGS. The proposed sensor requires fewer electronic components and eliminates the use of high-bandwidth components, such as operational amplifiers. The EBGS-RFD was evaluated for total bacterial count (TBC) using fifty-six raw milk samples. The β value representing the inflection points on the characteristic bacterial growth curves was obtained by the EBGS-RFD. From the significant correlation between β and TBC, obtained by the standard plate count (SPC), it was possible to cheaply and simply determine the TBC at various contamination levels in only 8 hours. Therefore, EBGS-RFD is suitable for TBC and real-time monitoring of bacterial growth in raw milk samples.


  • Mercury determination in bioresorbable calcium phosphate using a new electrothermal vaporization system coupled to ICP-MS

    by Jussiane S. Silva, Graciela M. Heidrich, Bruno O. Poletto, Jose N. G. Paniz, Valderi L. Dressler, Erico M. M. Flores

    A direct solid sampling method was developed for determining mercury in bioresorbable calcium phosphate-based materials by electrothermal vaporization (ETV) coupled to an inductively coupled plasma mass spectrometry (ICP-MS) instrument. The ETV system is based on fast sample heating using a halogen lamp enclosed in a glass chamber. The heating program comprises only a vaporization step (10 s) followed by a cooling step (120 s) when a solid sample was analyzed. An additional step of 20 s at 80 °C was necessary when aqueous solutions were used for calibration. Mercury was vaporized at a relatively low temperature (650 °C) without co-vaporizing the main matrix (more than 95% of the matrix remains in the lamp dimpled cavity). External calibration with aqueous reference solutions deposited on the sample residue was used for Hg quantification. The accuracy of the proposed method was evaluated by certified reference material analysis (MESS-3) and by pneumatic nebulization ICP-MS (NEB-ICP-MS), and no statistical difference was observed between the results. Relatively high masses (up to 10 mg) can be analyzed without interferences. The limit of quantification (0.2 ng g−1) by ETV-ICP-MS was lower than that by NEB-ICP-MS (60 ng g−1), the precision was better than 15% and the sample throughput was 20 per hour. Therefore, the proposed low-cost ETV system is attractive for determining Hg at the ultra-trace level in biomaterials and can be used for routine analyses.


  • A solid sampling approach for direct determination of Cl and S in flour by an elemental analyzer

    by Jussiane S. Silva, Lisarb O. Diehl, Rochele S. Picoloto, Erico M.M. Flores, Marcia F. Mesko, Juliano S. Barin, Fabio A. Duarte


  • Development of an electrothermal vaporizer for direct mercury determination in soil by inductively-coupled plasma mass spectrometry

    by Wilian Wohlmann, Vinicius M. Neves, Graciela M. Heidrich, Jussiane S. Silva, Adilson Ben da Costa, Jose N.G. Paniz, Valderi L. Dressler