AKAlexander Karaskov

Alexander Karaskov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alexander Karaskov has a total of 253 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    FLEXIBLE RINGS IN COMPARISON WITH RIGID RINGS IN THE TREATMENT OF FUNCTIONAL TRICUSPID INSUFFICIENCY: TWO DIFFERENT MODELS OF REVERSE REMODELING OF THE RIGHT HEART

    by M. A. Ovcharov, A. V. Bogachev-Prokofiev, D. A. Astapov, A. N. Pivkin, K. S. Malozemov, T. N. Podsosnikova, O. Yu. Malakhova, A. M. Karaskov

    Objective. To compare the models of reverse remodeling of the right heart after the tricuspid valve repair with rigid or flexible rings.Material and Methods. During the period from September, 2016 to February, 2018, 308 patients who had indications for intervention on the mitral valve and concomitant tricuspid insufficiency without significant differences in clinical status were randomized into two groups. Patients of both groups underwent intervention on the mitral valve with concomitant tricuspid valve repair by a rigid ring (Rigid group, n=154) or a flexible ring (Flex group, n=154)Results. The perioperative mortality rates were 2.0% in the Rigid group and 2.5% in the Flex group (p=0.504). There was no difference in the pacemaker implantation rate (5.1% vs. 2.6%, p=0.238). Freedom from tricuspid insufficiency recurrence at 12 months follow-up was comparable (96.7% in the Rigid group vs 96.1% in the Flex group, p=0.521). The global systolic function of the right ventricle (fractional change in area, FAC; ejection fraction, EF) significantly increased in both groups (pConclusion. Both types of the devises had low rates of recurrence of tricuspid insufficiency at the midterm follow-up and contributed to the restoration of the global systolic function of the right ventricle. However, the rigid rings due to their design fix the tricuspid valve annulus, which inevitably affects the regional systolic function. In perspective, the flexible rings can function without interfering with the restoration of the natural shape of the tricuspid valve annulus and its uniform contraction during the cardiac cycle, thus ensuring a significant increase in regional systolic function.

  • Open Access

    Tissue Engineering in Cardiovascular Surgery: Evolution and Contemporary Condition of the Problem

    by Ilya Alexandrovich Soynov, Irina Yurievna Zhuravleva, Yuriy Yurievich Kulyabin, Nataliya Romanova Nichay, Tatyana Pavlovna Timchenko, Alexey Victorovich Zubritskiy, Alexander Vladimirovich Bogachev-Prokophiev, Alexander Mihaylovich Karaskov, Сойнов Илья Александрович, Кулябин Юрий Юрьевич, et al.

    The “ideal” graft for forming outflow ways is a big issue in reconstructive heart valve surgery. For today, this question is a field of interest especially in pediatric cardiac surgery, because the existing prosthesis are exposed to aggressive degenerative processes due to metabolic features, and also do not have the growth potential. Therefore, repetitive graft reimplantation gradually increases risk of surgery and greatly reduce the quality of patient’s life. Tissue engineering is a new perspective approach in surgery of congenital and heart valve diseases, which may help overcome limitations of existing and provide the new opportunities for surgical correction. This review highlights current trends in development of tissue-engineered heart valves and grafts, and existing limitations and potential solutions are discussed.


  • Open Access

    Efficiency of transcatheter aortic valve implantation in patients with high surgical risk: long-term results of a single-center prospective study

    by O. V. Kamenskaya, I. Yu. Loginova, E. I. Kretov, A. A. Prokhorikhin, A. R. Tarkova, V. I. Baystrukov, V. V. Lomivorotov, А. М. Караськов

    Эффективность транскатетерной имплантации аортального клапана у пациентов высокого хирургического риска: отдаленные результаты одноцентрового проспективного исследования


  • Open Access

    Results of endovascular treatment of aortic valve disease in patients with intermediate surgical risk

    by I. Yu. Loginova, O. V. Kamenskaya, A. A. Prokhorikhin, A. R. Tarkova, E. I. Kretov, V. V. Lomivorotov, А. М. Караськов

    Aim. To assess the results of a one­year follow­up after transcatheter aortic valve implantation (TAVI) in patients with intermediate surgical risk with severe aortic stenosis.Material and methods. The study included 42 patients with hemodynamically significant aortic stenosis and intermediate surgical risk. We assess the incidence of prosthesis­associated complications, one­year survival, clinical and hemodynamic characteristics, as well as the dynamics of the quality of life and social adaptation in the early postoperative period and one year after the intervention.Results. In patients with intermediate surgical risk prosthesis­associated complications were not registered in the early postoperative period and one year after TAVI, the survival rate was 97,6% and 88%, respectively. The hemodynamic effect of the operation according to the results of echocardiography persisted a year after the intervention with the positive dynamics of the myocardial contractile function. The quality of life a year after the TAVI increased on the scale of the physical health of the SF­36 questionnaire from 25 (22;29) to 42 (28;46) points (p=0,031), on the mental health from 42 (33;50) up to 53 (48;57) points (p=0,025). The level of social adaptation has increased significantly; score of the Holmes and Rahe scale decreased from 250 (198;300) to 200 (180;220) (p=0,027). Conclusion. The hemodynamic efficacy of TAVI in patients with intermediate surgical risk with severe aortic stenosis is associated with a significant improvement of life quality and the level of social adaptation one year after the endovascular correction of valve defect.


  • Open Access

    The results of transcatheter mitral valve replacement

    by R. M. Sharifulin, A. V. Bogachev-­pRokofiev, I. Yu. Zhuravleva, T. P. Timchenko, S. I. Zheleznev, А. М. Караськов

    Mitral insufficiency is one of the most common valvular pathology. In almost half of the patients, standard mitral valve replacement using extracorporeal circulation cannot be used due to the high risk of complications. In recent years, for this category of patients a method for transcatheter mitral valve replacement has been proposed. Now it is known about a few transcatheter prostheses for implantation into the native mitral valve that are at the stage of preclinical or clinical trials. This article analyzes the results of the clinical use of prostheses for transcatheter mitral valve replacement.


  • Open Access

    Факторы влияющие на динамику качества жизни после хирургического лечения расслоения восходящего отдела и дуги аорты

    by O. V. Kamenskaya, A. S. Klinkova, I. Yu. Loginova, A. M. Chernyavsky, V. V. Lomivorotov, А. М. Караськов

    Aim.To assess the impact of clinical and intraoperative factors on the dynamics of quality of life (QOL) after aortic prosthetics in patients with chronic dissection of ascending aorta and aortic arch.Material and methods. The study included 56 patients (mean age 50 years) with chronic DeBakey type I aortic dissection. With the help of the SF­36 questionnaire, QOL was examined before and later (12 months) after aortic prosthetics. The method of multivariate linear regression analysis was used to evaluate factors that influence the dynamics of various parameters of QOL in the late postoperative period.Results.Before the operation, patients scored from 52 points and below almost in all parameters of the questionnaire, which indicates a very low initial level of QOL. In the long­term period after aortic prosthetics, a statistically significant improvement in the following physical and psycho­emotional indicators was noted: role functioning (p=0,004); bodily pain (p=0,0001); vitality (p=0,009); social role functioning (p=0,002); emotional role functioning (p=0,009); physical health (p=0,02); mental health (p=0,03). At the same time, there was no positive change in the initial low parameters of general health and psychiatric health perceptions.According to multivariate regression analysis, the dynamics of QOL parameters in the long­term period after surgical treatment of the dissection of ascending aorta and aortic arch are affected by both intraoperative conditions (cerebral protection method) and the early postoperative period (neurological complications, cardiopulmonary failure, atrial fibrillation). Indicators such as gender, age, body weight, comorbidity, type of prosthesis of the ascending aorta, time spent in the intensive care unit, duration of artificial pulmonary ventilation do not have a significant effect on QOL in the long­term postoperative period.Conclusion.Clinical and intraoperative factors that adversely affect the dynamics of various indicators of QOL in long­term periods after prosthetics of the ascending aorta and aortic arch were: cerebral protection in conditions of deep hypothermia and craniocerebral hypothermia against the background of systemic circulatory arrest; development of neurological complications, as well as atrial fibrillation and cardiopulmonary failure in the early postoperative period.


  • Open Access

    The first experience of implantation of the transcatheter aortal valve prosthesis “MedLab-KT”

    by A. V. Bogachev-­pRokofiev, R. M. Sharifulin, D. D. Zubarev, А. М. Караськов

    Aim.Transcatheter aortic valve replacement in patients with high and extremely high risk has become a routine procedure in many cardiac surgery clinics. Until recently, there were no transcatheter prostheses produced within Russia. This article analyzes the results of applying the first domestic transcatheter aortic valve prosthesis MedLab­KT.Material and methods.In the period from June 2018 to October 2018, 7 operations of transcatheter aortic valve replacement were made using the MedLabKT prosthesis. In all cases, implantation was performed by transapical access.Results.We noted one death. In all cases, paraprosthetic regurgitation was not registrated or was not significant. There are no cases of dislocation of the prosthesis. There were no complications associated with access. In one case, implantation was complicated by myocardial infarction.Conclusion.The first experience of implantation demonstrated the efficacy and safety of using the MedLab­LT prosthesis for transcatheter aortic valve replacement. The analysis of long­term results is required.

  • Open Access

    Cardiac surgery in Siberia: present and perspectives

    by A. V. Bogachev-Prokophiev, A. V. Sapegin, A. M. Karaskov

    Cardiovascular surgery, like any science, is continually evolving. The main characteristics of its development are the availability of care to the population and decreasing of morbidity and mortality. To this end, Russia has established a system of reporting, which is implemented through the activities of the chief experts. According to the Ministry of Health of the Russian Federation, the Siberian Federal District in terms of reducing the incidence of cardiovascular disease is one of the best in Russia. The review presents data from the annual report of the chief cardio-vascular surgeon of the Siberian Federal District.Received 1 December 2017. Accepted 4 December 2017.Funding: The study did not have sponsorship.Conflict of interest: Authors declare no conflict of interest.


  • Open Access

    Deformational dynamics of the aortic root in elderly patients after aortic valve replacement with biological prostheses

    by D. P. Demidov, D. A. Astaspov, A. V. Bogachev-Prokophiev, S. I. Zheleznev, A. M. Karaskov

    Aim. The study was designed to comparatively assess dynamic changes of the aortic root structures depending on a phase of the cardiac cycle in patients with degenerative aortic stenosis, who underwent aortic valve replacement with different types of biological prostheses.Methods. This prospective parallel controlled randomized trial study was performed at Meshalkin National Medical Research Center over a period from 2011 to 2015. The inclusion criteria were severe aortic stenosis and patients’ age older than 65 years. 114 patients were randomized 1:1 in two groups: group I included 57 patients with stentless biological prostheses, while group II (control one) consisted of 57 patients with stented xenopericardial prostheses. The average age was 71 [66; 74] and 72 [69; 77] for the first and second groups, respectively (p = 0.054). All patients underwent aortic valve replacement. The operation was performed under standard normothermic cardiopulmonary bypass. The diameter of the implanted prostheses was 25 mm [24; 26] and 23 mm [21; 23] for the first and second groups, respectively (p = 0.375). An ECG-synchronized CT study of the aortic root was carried out in the postoperative period.Results. An intergroup systolic/diastolic difference in the values of the cross-sectional area of the aortic root at all levels was observed in patients with stentless bioprostheses, while the control group patients (with stented bioprostheses) had no such difference at the levels of the left ventricle output tract and the fibrous ring of the aortic valve.Conclusion. A stentless design of bioprostheses retains the deformational and elastic properties of the aortic root in elderly patients with aortic valve stenosis after surgical treatment.Received 5 December 2017. Revised 12 December 2017. Accepted 15 December 2017.Funding: The study did not have sponsorship.Conflict of interest: The authors declare no conflict of interest.Author contributionsConception and study design: D.P. Demidov, D.A. Astapov, A.V. Bogachev-ProkophievData collection and analysis: D.P. DemidovDrafting the article: D.P. DemidovCritical revision of the article: D.A. Astapov, A.V. Bogachev-ProkophievFinal approval of the version to be published: D.A. Astapov, A.V. Bogachev-Prokophiev, S.I. Zheleznev, A.M. Karaskov

  • Postcardiotomy refractory ventricular fibrillation: rescue using veno-arterial extracorporeal membrane oxygenation

    by Ilya Soynov, Igor Kornilov, Alexey Zubritskiy, Dmitriy Ponomarev, Nataliya Nichay, Artem Gorbatykh, Alexey Voitov, Alexander Karaskov

    We present a case of 7-hour ventricular fibrillation with successful use of veno-arterial extracorporeal membrane oxygenation as a bridge to recovery in a 30-year-old patient with grown-up congenital heart disease who underwent pulmonary valve replacement.