Gamal M. Hassan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gamal M. Hassan has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
M.A. Sharaf
9 shared publications- Eslam Aboelezz
Ionizing Radiation Metrology Department, National Institute of Standards (NIS), Giza, Egypt
8 shared publications A. El-Khodary
5 shared publicationsMotoji Ikeya
5 shared publicationsH.M. Eissa
3 shared publicationsN. Rabie
Department of Ionizing Radiation Metrology , National Institute for Standards , El-Haram El-Giza, PO Box 136 Giza, El-Giza Egypt
3 shared publications
Latest Publications
- 1 March 2020
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 59 (1) , 131-144
Assessment of absorbed dose of gamma rays using the simultaneous determination of inactive hemoglobin derivatives as a biological dosimeter
Biological dosimetry based on sulfhemoglobin (SHb), methemoglobin (MetHb), and carboxyhemoglobin (HbCO) levels was evaluated. SHb, MetHb and HbCO levels were estimated in erythrocytes of mice irradiated by gamma rays from a Co-60 source using the method of multi-component spectrophotometric analysis developed recently. In this method, absorption measurements of diluted aqueous Hb-solution were made at lambda = 500, 569, 577 and 620 nm, and using the mathematical formulas based on multi-component spectrophotometric analysis and the mathematical Gaussian elimination method for matrix calculation, the concentrations of various Hb-derivatives and total Hb in mice blood were estimated. The dose range of gamma rays was from 0.5 to 8 Gy and the dose rate was 0.5 Gy min(-1). Among all Hb-derivatives, MetHb, SHb and HbCO demonstrated an unambiguous dose-dependent response. For SHb and MetHb, the detection limits were about 0.5 Gy and 1 Gy, respectively. After irradiation, high levels of MetHb, SHb and HbCO persisted for at least 10 days, and the maximal increase of MetHb, SHb and HbCO occurred up to 24 h following gamma irradiation. The use of this "MetHb + SHb + HbCO"-derivatives-based absorbed dose relationship showed a high accuracy. It is concluded that simultaneous determination of MetHb, SHb and HbCO, by multi-component spectrophotometry provides a quick, simple, sensitive, accurate, stable and inexpensive biological indicator for the early assessment of the absorbed dose in mice.
- 1 March 2020
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 59 (1) , 131-144
Assessment of absorbed dose of gamma rays using the simultaneous determination of inactive hemoglobin derivatives as a biological dosimeter
Biological dosimetry based on sulfhemoglobin (SHb), methemoglobin (MetHb), and carboxyhemoglobin (HbCO) levels was evaluated. SHb, MetHb and HbCO levels were estimated in erythrocytes of mice irradiated by gamma rays from a Co-60 source using the method of multi-component spectrophotometric analysis developed recently. In this method, absorption measurements of diluted aqueous Hb-solution were made at lambda = 500, 569, 577 and 620 nm, and using the mathematical formulas based on multi-component spectrophotometric analysis and the mathematical Gaussian elimination method for matrix calculation, the concentrations of various Hb-derivatives and total Hb in mice blood were estimated. The dose range of gamma rays was from 0.5 to 8 Gy and the dose rate was 0.5 Gy min(-1). Among all Hb-derivatives, MetHb, SHb and HbCO demonstrated an unambiguous dose-dependent response. For SHb and MetHb, the detection limits were about 0.5 Gy and 1 Gy, respectively. After irradiation, high levels of MetHb, SHb and HbCO persisted for at least 10 days, and the maximal increase of MetHb, SHb and HbCO occurred up to 24 h following gamma irradiation. The use of this "MetHb + SHb + HbCO"-derivatives-based absorbed dose relationship showed a high accuracy. It is concluded that simultaneous determination of MetHb, SHb and HbCO, by multi-component spectrophotometry provides a quick, simple, sensitive, accurate, stable and inexpensive biological indicator for the early assessment of the absorbed dose in mice.
- 1 September 2019
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 162, 131-135
Evaluation of thermal neutron dose from Am-Be source using gelatinized boron fricke dosimeter
- 1 September 2019
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 162, 131-135
Evaluation of thermal neutron dose from Am-Be source using gelatinized boron fricke dosimeter
- 31 August 2018
- Published by Praise Worthy Prize in International Review of Aerospace Engineering (IREASE)
- Vol. 11 (4) , 155
Performance Evaluation of Selected Irradiated Space Structure Composites Manufactured by the Hand Lay-Up Method
Performance Evaluation of Selected Irradiated Space Structure Composites Manufactured by the Hand Lay-Up Method
- 31 August 2018
- Published by Praise Worthy Prize in International Review of Aerospace Engineering (IREASE)
- Vol. 11 (4) , 155
Performance Evaluation of Selected Irradiated Space Structure Composites Manufactured by the Hand Lay-Up Method
Performance Evaluation of Selected Irradiated Space Structure Composites Manufactured by the Hand Lay-Up Method
- 1 April 2018
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 145, 5-10
Resolving the limitations of using glycine as EPR dosimeter in the intermediate level of gamma dose
- 1 April 2018
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 145, 5-10
Resolving the limitations of using glycine as EPR dosimeter in the intermediate level of gamma dose
- 1 May 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 134, 14-18
Effect of γ-irradiation on the optical and electrical properties of fiber reinforced composites
- 1 May 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 134, 14-18
Effect of γ-irradiation on the optical and electrical properties of fiber reinforced composites
- 1 November 2016
- Published by Elsevier in Journal of Luminescence
- Vol. 179, 616-621
Glow curve deconvolution of nano barium strontium sulfate and thermoluminescence trap centers behavior with gamma doses
- 1 November 2016
- Published by Elsevier in Journal of Luminescence
- Vol. 179, 616-621
Glow curve deconvolution of nano barium strontium sulfate and thermoluminescence trap centers behavior with gamma doses
- 1 October 2015
- Published by Elsevier in Journal of Luminescence
- Vol. 166, 156-161
Nano-barium–strontium sulfate as a new thermoluminescence dosimeter
- 1 October 2015
- Published by Elsevier in Journal of Luminescence
- Vol. 166, 156-161
Nano-barium–strontium sulfate as a new thermoluminescence dosimeter
- 1 January 2015
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 106, 385-393
EPR dosimetric properties of nano-barium sulfate
- 1 January 2015
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 106, 385-393
EPR dosimetric properties of nano-barium sulfate
- 1 June 2014
- Published by Elsevier in Radiation Measurements
- Vol. 65, 29-35
Effect of strontium additive on thermoluminescence properties of (Ba1-xSrxSO4)99.8%: Eu0.2% nanophosphor
- 1 June 2014
- Published by Elsevier in Radiation Measurements
- Vol. 65, 29-35
Effect of strontium additive on thermoluminescence properties of (Ba1-xSrxSO4)99.8%: Eu0.2% nanophosphor
- 1 September 2012
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 167 (9) , 704-711
Study on the quality assurance of diagnostic X-ray machines and assessment of the absorbed dose to patients
Radiation exposure and image quality in X-ray diagnostic radiology provide a clear understanding of the relationship between the radiation dose delivered to a patient and image quality in optimizing medical diagnostic radiology. Because a certain amount of radiation is unavoidably delivered to patients, this should be as low as reasonably achievable. Several X-ray diagnostic machines were used at different medical diagnostic centers in Egypt for studying the beam quality and the dose delivered to the patient. This article studies the factors affecting the beam quality, such as the kilo-volt peak (kVp), exposure time (mSc), tube current (mAs) and the absorbed dose in (μGy) for different examinations. The maximum absorbed dose measured per mAs was 594±239 and 12.5±3.7 μGy for the abdomen and the chest, respectively, while the absorbed dose at the elbow was 18±6 μGy, which was the minimum dose recorded. The compound and expanded uncertainties accompanying these measurements were 4±0.35% and 8±0.7%, respectively. The measurements were done through quality control tests as acceptance procedures.
- 1 September 2012
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 167 (9) , 704-711
Study on the quality assurance of diagnostic X-ray machines and assessment of the absorbed dose to patients
Radiation exposure and image quality in X-ray diagnostic radiology provide a clear understanding of the relationship between the radiation dose delivered to a patient and image quality in optimizing medical diagnostic radiology. Because a certain amount of radiation is unavoidably delivered to patients, this should be as low as reasonably achievable. Several X-ray diagnostic machines were used at different medical diagnostic centers in Egypt for studying the beam quality and the dose delivered to the patient. This article studies the factors affecting the beam quality, such as the kilo-volt peak (kVp), exposure time (mSc), tube current (mAs) and the absorbed dose in (μGy) for different examinations. The maximum absorbed dose measured per mAs was 594±239 and 12.5±3.7 μGy for the abdomen and the chest, respectively, while the absorbed dose at the elbow was 18±6 μGy, which was the minimum dose recorded. The compound and expanded uncertainties accompanying these measurements were 4±0.35% and 8±0.7%, respectively. The measurements were done through quality control tests as acceptance procedures.