  • CAP waveform estimation from the measured electrical bioimpedance values: Patient's heart rate variability analysis

    by A. Krivoshei, H. Uuetoa, M. Min, P. Annus, T. Uuetoa, J. Lamp

    The paper presents analysis of the generic transfer function (TF) between Electrical Bioimpedance (EBI) measured non-invasively on the wrist and Central Aortic Pressure (CAP) invasively measured at the aortic root. Influence of the Heart Rate (HR) variations on the generic TF and on reconstructed CAP waveforms is investigated. The HR variation analysis is provided on a single patient data to exclude inter-patient influences at the current research stage. A new approach for the generic TF estimating from a data ensemble is presented as well. Moreover, an influence of the cardiac period beginning point selection is analyzed and empirically optimal solution for its selection is proposed.


  • A bio-impedance signal simulator (BISS) for research and training purposes

    by Yar M. Mughal, Yannick Le Moullec, Paul Annus, Andrei Krivoshei

    A Bio-Impedance Signal Simulator (BISS) is developed based on the models of the impedance cardiography (ICG) and impedance respirography (IRG) signals. With the aim of imitating the real ICG and IRG phenomena, the ICG and IRG signals are modelled and combined with motion artefacts and Gaussian noise. The simulator allows the user to load different predefined human activity states such as resting, standing, walking, and running. Moreover, and importantly, the user can also control the parameters as per his/her needs and generate Electrical Bio-Impedance (EBI) datasets for further processing. Possible applications of BISS include research (e.g. performance evaluation of cardiac and respiratory separation algorithms) as well as teaching and training in physiological courses. To the best of our knowledge, BISS is the first EBI signal simulator that imitates the real ICG and IRG signals phenomena.


  • Electrical Bio-Impedance based non-invasive method for the Central Aortic blood pressure waveform estimation

    by Andrei Krivoshei, Mart Min, Hasso Uuetoa, Jurgen Lamp, Paul Annus

    Non-invasive and safe method for estimation of the Central Aortic Pressure (CAP) waveform is presented. It is based on the measurement of Electrical Bio-Impedance (EBI) on radial artery. Reconstruction of the CAP curve from the EBI data is provided by an introduced spectral domain transfer function (TF). The TF estimation algorithm and the Augmentation Index (AI) evaluation method are described. Proposed approach is less dependent on the operator and more convenient than traditional tonometry based method. It allows continuous and long term monitoring of the AI and CAP variations. Feasibility and accuracy of the technique was evaluated in clinical surroundings by comparing invasively measured CAP and AI data with non-invasive EBI based estimates. Clinical experiments were conducted in the Heart Centre of the East-Tallinn Central Hospital during scheduled coronary angiography. Age of the patients varied randomly between 43 and 80.


  • Robust algorithm for the Augmentation Index estimation of the CAP using low order derivatives

    by Andrei Krivoshei, Mart Min, Jurgen Lamp, Paul Annus

    The paper presents a novel algorithm for the central Augmentation Index (AI) estimation and it is robust and suitable for long-term monitoring. To increase the robustness of the proposed method, only first and second order derivatives of the Central Aortic Pressure (CAP) pulse are used. Low-order Legendre polynomials approximation was applied for some intervals of the CAP waveform to find locations of special points on the CAP curve, which are participate in the AI evaluation. Continuous monitoring plots of the AI after administrating a tablet of 0.5 mg sublingual nitroglycerin are presented.


  • Open Access

    Separation of cardiac and respiratory components from the electrical bio-impedance signal using PCA and fast ICA

    by Yar M. Mughal, A. Krivoshei, P. Annus

    This paper is an attempt to separate cardiac and respiratory signals from an electrical bio-impedance (EBI) dataset. For this two well-known algorithms, namely Principal Component Analysis (PCA) and Independent Component Analysis (ICA), were used to accomplish the task. The ability of the PCA and the ICA methods first reduces the dimension and attempt to separate the useful components of the EBI, the cardiac and respiratory ones accordingly. It was investigated with an assumption, that no motion artefacts are present. To carry out this procedure the two channel complex EBI measurements were provided using classical Kelvin type four electrode configurations for the each complex channel. Thus four real signals were used as inputs for the PCA and fast ICA. The results showed, that neither PCA nor ICA nor combination of them can not accurately separate the components at least are used only two complex (four real valued) input components.


    • 1 January 2013
      • Vol. 189, 101-6

    Wearable system for non-invasive and continuous monitoring central aortic pressure curve and augmentation index.

    by Andrei Krivoshei, Jürgen Lamp, Mart Min, Tiina Uuetoa, Hasso Uuetoa, Paul Annus

    The paper presents a non-invasive method and system for a long-term and continuous monitoring of the central aortic pressure (CAP) waveform and the augmentation index (AI). The CAP curve is estimated from the measured radial electrical bio-impedance (EBI) using spectral domain transfer functions (TF), which are established on the basis of data analysis during clinical experiments. Experiments were carried out on 3 volunteers by now. During the experiment, a 0.5 mg sublingual nitroglycerin tablet was administrated to each volunteer. Both, the reconstructed CAP curve and the AI have very good correlation with the results obtained by the SphygmoCor system. But, in opposite to the traditional tonometry based CAP curve and AI estimation methods, the proposed one is more convenient to use and allows continuous and long-term personalized monitoring of the CAP curve and of the AI.

    • 1 January 2013
      • Vol. 189, 107-12

    Wearable data acquisition system of multimodal physiological signals for personal health care.

    by Paul Annus, Ali Samieipour, Marek Rist, Indrek Ruiso, Andrei Krivoshei, Raul Land, Toomas Parve, Mart Min

    The paper proposes a wearable multimodal data acquisition system for biological signals. The system enables logging of electrical bioimpedance signals from multiple electrodes, electrocardiographic signals (ECG), acceleration signals from multiple locations, and spirometric data from a moving object. Later it will be used to conduct field measurements for characterizing health of the object under investigation. Main goal is to acquire enough data for development, refinement, and simplification of signal processing algorithms. The system is center part of the new wearable compact data acquisition modules ZCardio. Those modules enable multichannel impedance spectroscopy by logging ECG signals and data from the spirometric sensor. Initial reference measurements were conducted. Alternatively, tests were performed using Plessey Semiconductors capacitive sensors. Acceleration signals are gathered.

  • Open Access

    Bio-impedance signal decomposer: enhanced accuracy and reduced latency solution; pp. 201–219

    by Andrei Krivoshei

    The paper presents an overview of the electrical bio-impedance (EBI) signal decomposi­tion into its cardiac and respiratory components. This problem mainly originates from the non­stationarity of the signal components and overlapping of their harmonic spectra. In the introductory part of the paper, an overview of the bio-impedance signal decomposer (BISD), as a solution of the problem, is accompanied with an introduction to a cardiac BI signal model, which is constructed from the components of the application-specific orthonormal basis. In the main part of the paper a semi-synchronous cardiac signal amplitude estimator, which is based on the cardiac signal model and on the proposed extrema searching algorithm, is proposed. After that, the cardiac signal lock-in detection algorithm is proposed. Finally, a conditioning of the estimated cardiac signal frequency is discussed. The proposed amplitude estimator, lock-in detector and frequency conditioning increase twice the reaction speed of the BISD to the input EBI signal. The proposed version of the BISD estimates the cardiac signal amplitude during only a few cardiac periods, even if very large difference between amplitudes exists in different conditions. As a result, the entire BISD becomes locked during 8 s (including 4 s of soft start). The proposed improvements allowed reducing the latency of the BISD from 2 to 1 s.


  • Decomposition method of an electrical bio-impedance signal into cardiac and respiratory components

    by A Krivoshei, V Kukk, M Min

    The paper presents a method for adaptive decomposition of an electrical bio-impedance (BI) signal into two components: cardiac and respiratory. The decomposition of a BI signal is not a trivial process because of the non-stationarity of the signal components and overlapping of their harmonic spectra. An application specific orthonormal basis (ASOB) was designed to solve the decomposition task using the Jacobi weighting function in the standard Gram-Schmidt process. The key element of the bio-impedance signal decomposer (BISD) is a model of the cardiac BI signal, which is constructed from the components of the ASOB and is intended for use in the BISD for on-line tracking of the cardiac BI signal. It makes it possible to separate the cardiac and respiratory components of the total BI signal in non-stationary conditions. In combination with the signal-shape locked loop (SSLL), the BISD allows us to decompose the BI signals with partially overlapping spectra. The proposed BISD based method is accomplished as a PC software digital system, but it is oriented towards applications in portable and stationary cardiac devices and in clinical settings.