ATAhamd Tahmasebi

Ahamd Tahmasebi

*This is an algorithmically generated author record based on publicly available information.

Ahamd Tahmasebi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effects of Different Target Solar Fractions on Providing Heat Required for Space Heating, Sanitary Hot Water, and Swimming Pool in Iran: A Case Study in Cold Climate

    by Nastaran Saberi Shahmarvandi, Fateme Shahrokh Ghahfarokhi, Zahra Delshad Chermahini, Atefeh Faramarzi, Alireza Raisi, Reza Alayi, Ahmad Tahmasebi

    Due to limited fossil fuel resources, population growth, and the need to save energy and prevent the emission of pollutants, solar heating is of great importance as a strategic solution. Due to these cases, in the present work, for the first time, the use of flat plate solar water heaters (SWHs) in Shahrekord located in the cold climate of Iran has been studied. The aim is to supply heating for space, sanitary hot water, and swimming pool of a residential apartment. Also, technical-economic-energy-environmental analyses have been done. Three low, medium, and high solar fraction scenarios have been selected for evaluations, and one-year dynamic analysis has been performed by TSOL 2018 commercial software. The required climatic data have been extracted by Meteonorm 7.3 software. The results showed that in most cases of heat supply, i.e., high solar fraction scenario, the percentage of solar heat supply for sanitary hot water, space heating, and swimming pool is 97.8, 22.3, and 44.3, respectively, and the total solar fraction is 41. Also, in this case, the release of more than 4 tons of CO2 pollutants has been prevented. Energy balance diagrams for different scenarios showed that 60 of losses are optical and thermal and also the highest rate of losses was related to the swimming pool. The lowest cost of heat generated and the lowest payback time were $ 0.028/kWh and 11.4 years, respectively, which were related to the high solar fraction scenario.


  • Open Access

    Natural Convection and Entropy Generation of MgO/Water Nanofluids in the Enclosure under a Magnetic Field and Radiation Effects

    by Yacine Khetib, Ahmad Aziz Alahmadi, Ali Alzaed, Ahamd Tahmasebi, Mohsen Sharifpur, Goshtasp Cheraghian

    The authors of the present paper sought to conduct a numerical study on the convection heat transfer, along with the radiation and entropy generation (EGE) of a nanofluids (NFs) in a two and three-dimensional square enclosure, by using the FVM. The enclosure contained a high-temperature blade in the form of a vertical elliptical quadrant in the lower corner of the enclosure. The right edge of the enclosure was kept at low temperature, while the other edges were insulated. The enclosure was subjected to a magnetic field (MGF) and could be adjusted to different angles. In this research, two laboratory relationships dependent on temperature and volume fraction were used to simulate thermal conductivity and viscosity. The variables of this problem were Ra, Ha, RAP, nanoparticle (NP) volume fraction, blade aspect ratio, enclosure angles, and MGF. Evaluating the effects of these variables on heat transfer rate (HTR), EGE, and Be revealed that increasing the Ra and reducing the Ha could increase the HTR and EGE. On the other hand, adding radiation HTR to the enclosure increased the overall HTR. Moreover, an augmentation of the volume fraction of magnesium oxide NPs led to an increased amount of HTR and EGE. Furthermore, any changes to the MGF and the enclosure angle imposed various effects on the HTR. The results indicated that an augmentation of the size of the blade increased and then decreased the HTR and the generated entropy. Finally, increasing the blade always increased the Be.


  • Open Access

    Effects of Different Wall Shapes on Thermal-Hydraulic Characteristics of Different Channels Filled with Water Based Graphite-SiO2 Hybrid Nanofluid

    by Yacine Khetib, Ahmad Alahmadi, Ali Alzaed, Ahamd Tahmasebi, Mohsen Sharifpur, Goshtasp Cheraghian

    In the current numerical study, various wall shape effects are investigated on the thermal-hydraulic characteristics of different channels filled with water-based graphite-SiO2 hybrid nanofluid. In this work, the performance evaluation criteria (PEC) index is employed as the target parameter to attain optimum geometry. Six different cases are studied in this research, and each case has different geometrical dimensions. The inlet temperature for the fluids in the channel is 300 K, over a range of different flow velocities. According to the obtained results, an increase in the volume fraction of nanoparticles results in higher PEC values. In addition, an increase in Reynolds number to Re = leads to an increase in the PEC index. The results clearly show that increasing the Reynolds number has two consequences: on the one hand, it increases the pressure drop penalty; on the other hand, it improves heat transfer. Therefore, the maximum value of the PEC index occurs at Re = 15,000.


  • Open Access

    Comprehensive Investigation of Solar-Based Hydrogen and Electricity Production in Iran

    by Rasool Kalbasi, Mehdi Jahangiri, Ahmad Tahmasebi

    Hydrogen is a clean and environmentally friendly energy vector that can play an important role in meeting the world’s future energy needs. Therefore, a comprehensive study of the potential for hydrogen production from solar energy could greatly facilitate the transition to a hydrogen economy. Because by knowing the exact amount of potential for solar hydrogen production, the cost-effectiveness of its production can be compared with other methods of hydrogen production. Considering the above, it can be seen that so far no comprehensive study has been done on finding the exact potential of solar hydrogen production in different stations of Iran and finding the most suitable station. Therefore, in the present work, for the first time, using the HOMER and ArcGIS softwares, the technical-economic study of solar hydrogen production at home-scale was done. The results showed that Jask station with a levelized cost of energy equal to $ 0.172 and annual production of 83.8 kg of hydrogen is the best station and Darab station with a levelized cost of energy equal to $ 0.286 and annual production of 50.4 kg of hydrogen is the worst station. According to the results, other suitable stations were Bushehr and Deyr, and other unsuitable stations were Anzali and Khalkhal. Also, in 102 under study stations, 380 MW of solar electricity equivalent to 70.2 tons of hydrogen was produced annually. Based on the geographic information system map, it is clear that the southern half of Iran, especially the coasts of the Persian Gulf and the sea of Oman, is suitable for hydrogen production, and the northern, northeastern, northwestern, and one region in southern of Iran are unsuitable for hydrogen production. The authors of this article hope that the results of the present work will help the energy policymakers to create strategic frameworks and a roadmap for the production of solar hydrogen in Iran.