Adrian Tanskanen
Research Subjects
Adrian Tanskanen has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Jeanie Malone
British Columbia Cancer Research Institute
7 shared publications - Pierre Lane
Department of Integrative Oncology, British Columbia Cancer Research Institute, 675 W 10th Ave., Vancouver, BC V5Z 1L3, Canada
7 shared publications - Calum MacAulay
Basic and Translational Research, BC Cancer Research Institute, 675 West 10th Avenue, Vancouver, BC V5Z Il3, Canada
5 shared publications Calum MacAulay
British Columbia Cancer Research Institute
4 shared publications- Chloe Hill
British Columbia Cancer Research Institute, Simon Fraser University, Canada
4 shared publications - Allan Zuckermann Cynamon
Department of Integrative Oncology, British Columbia Cancer Research Institute, 675 W 10th Avenue, Vancouver, BC V5Z 1L3, Canada
2 shared publications
Latest Publications
- 9 June 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (7) , 3502-3524
Quantification and mitigation of system background fluorescence in fiber-optic-based imaging systems
Autofluorescence imaging provides a snapshot of tissue biochemistry that can be used to identify dysplastic tissue. However, deployment in multimodal single-fiber imaging systems is limited by system background fluorescence. We propose to improve the signal-to-background ratio (SBR) through the removal of background emission in fiber-optic catheters for autofluorescence and optical coherence tomography. We collected power and spectral measurements of optical components to characterize their emissions using 450 nm excitation. We measured the per-meter fluorescence contribution of single-mode, double-clad, and multimode optical fibers. By tailoring the detection filter to the emission spectra of the target tissue and system background, we have demonstrated an average of 7.9x improvement in SBR.
- 9 June 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (7) , 3502-3524
Quantification and mitigation of system background fluorescence in fiber-optic-based imaging systems
Autofluorescence imaging provides a snapshot of tissue biochemistry that can be used to identify dysplastic tissue. However, deployment in multimodal single-fiber imaging systems is limited by system background fluorescence. We propose to improve the signal-to-background ratio (SBR) through the removal of background emission in fiber-optic catheters for autofluorescence and optical coherence tomography. We collected power and spectral measurements of optical components to characterize their emissions using 450 nm excitation. We measured the per-meter fluorescence contribution of single-mode, double-clad, and multimode optical fibers. By tailoring the detection filter to the emission spectra of the target tissue and system background, we have demonstrated an average of 7.9x improvement in SBR.
- Open Access
- 1 October 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (10) , 105002-22
Segmental airway adenocarcinoma-simulating phantom for endoscopic near-infrared optical coherence tomography
Endobronchial optical coherence tomography (EB-OCT) involves the deployment of an optical imaging catheter through the working channel of a bronchoscope to capture volumetric images of airway structure with microscopic ( to ) resolution. EB-OCT has shown promise in airway structural imaging and applications in lung cancer, where there is need for early detection and biopsy guidance.1 – 5- 1 October 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (10) , 105002-22
Open AccessSegmental airway adenocarcinoma-simulating phantom for endoscopic near-infrared optical coherence tomography
Endobronchial optical coherence tomography (EB-OCT) involves the deployment of an optical imaging catheter through the working channel of a bronchoscope to capture volumetric images of airway structure with microscopic ( to ) resolution. EB-OCT has shown promise in airway structural imaging and applications in lung cancer, where there is need for early detection and biopsy guidance.1 – 5 - Open Access
Multimodal Optical Imaging of Ex Vivo Fallopian Tubes to Distinguish Early and Occult Tubo-Ovarian Cancers
Background: There are currently no effective screening measures to detect early or occult tubo-ovarian cancers, resulting in late-stage detection and high mortality. This work explores whether an optical imaging catheter can detect early-stage tubo-ovarian cancers or precursor lesions where they originate in the fallopian tubes. Methods: This device collects co-registered optical coherence tomography (OCT) and autofluorescence imaging (AFI). OCT provides three-dimensional assessment of underlying tissue structures; autofluorescence imaging provides functional contrast of endogenous fluorophores. Ex vivo fallopian tubes (n = 28; n = 7 cancer patients) are imaged; we present methods for the calculation of and analyze eleven imaging biomarkers related to fluorescence, optical attenuation, and OCT texture for their potential to detect tubo-ovarian cancers and other lesions of interest. Results: We visualize folded plicae, vessel-like structures, tissue layering, hemosiderin deposits, and regions of fibrotic change. High-grade serous ovarian carcinoma appears as reduced autofluorescence paired with homogenous OCT and reduced mean optical attenuation. Specimens containing cancerous lesions demonstrate a significant increase in median autofluorescence intensity and decrease in Shannon entropy compared to specimens with no lesion. Non-cancerous specimens demonstrate an increase in optical attenuation in the fimbriae when compared to the isthmus or the ampulla. Conclusions: We conclude that this approach shows promise and merits further investigation of its diagnostic potential.
Open AccessMultimodal Optical Imaging of Ex Vivo Fallopian Tubes to Distinguish Early and Occult Tubo-Ovarian Cancers
Background: There are currently no effective screening measures to detect early or occult tubo-ovarian cancers, resulting in late-stage detection and high mortality. This work explores whether an optical imaging catheter can detect early-stage tubo-ovarian cancers or precursor lesions where they originate in the fallopian tubes. Methods: This device collects co-registered optical coherence tomography (OCT) and autofluorescence imaging (AFI). OCT provides three-dimensional assessment of underlying tissue structures; autofluorescence imaging provides functional contrast of endogenous fluorophores. Ex vivo fallopian tubes (n = 28; n = 7 cancer patients) are imaged; we present methods for the calculation of and analyze eleven imaging biomarkers related to fluorescence, optical attenuation, and OCT texture for their potential to detect tubo-ovarian cancers and other lesions of interest. Results: We visualize folded plicae, vessel-like structures, tissue layering, hemosiderin deposits, and regions of fibrotic change. High-grade serous ovarian carcinoma appears as reduced autofluorescence paired with homogenous OCT and reduced mean optical attenuation. Specimens containing cancerous lesions demonstrate a significant increase in median autofluorescence intensity and decrease in Shannon entropy compared to specimens with no lesion. Non-cancerous specimens demonstrate an increase in optical attenuation in the fimbriae when compared to the isthmus or the ampulla. Conclusions: We conclude that this approach shows promise and merits further investigation of its diagnostic potential.
- Open Access
- 12 September 2024
- Published by MDPI AG in Preprints.org
Multimodal Optical Imaging of Ex Vivo Fallopian Tubes to Distinguish Early and Occult Tubo-Ovarian Cancers
There are currently no effective screening measures to detect early or occult tubo-ovarian cancers resulting in late-stage detection and high mortality. This work explores whether an optical imaging catheter can detect early-stage tubo-ovarian cancers or precursor lesions where they originate in the fallopian tubes. This device collects co-registered optical coherence tomography (OCT) and autofluorescence imaging (AFI). OCT provides three-dimensional assessment of underlying tissue structures; autofluorescence imaging provides functional contrast of endogenous fluorophores. Ex vivo fallopian tubes (n=28; n=7 cancer) are imaged; we present methods for the calculation of and analyze eleven imaging biomarkers related to fluorescence, optical attenuation, and OCT texture for their potential to detect tubo-ovarian cancers and other lesions of interest. We visualize folded plicae, vessel-like structures, tissue layering, hemosiderin deposits, and regions of fibrotic change. High grade serous ovarian carcinoma appears as reduced autofluorescence paired with homogenous OCT and reduced mean optical attenuation. Specimens containing a cancerous lesion demonstrate significant increase in median autofluorescence intensity and decrease in entropy compared specimens with no lesion. Non-cancerous specimens demonstrate an increase in optical attenuation in the fimbriae when compared to the isthmus or ampulla. We conclude that this approach shows promise and merits further investigation of diagnostic potential.
- 12 September 2024
- Published by MDPI AG in Preprints.org
Open AccessMultimodal Optical Imaging of Ex Vivo Fallopian Tubes to Distinguish Early and Occult Tubo-Ovarian Cancers
There are currently no effective screening measures to detect early or occult tubo-ovarian cancers resulting in late-stage detection and high mortality. This work explores whether an optical imaging catheter can detect early-stage tubo-ovarian cancers or precursor lesions where they originate in the fallopian tubes. This device collects co-registered optical coherence tomography (OCT) and autofluorescence imaging (AFI). OCT provides three-dimensional assessment of underlying tissue structures; autofluorescence imaging provides functional contrast of endogenous fluorophores. Ex vivo fallopian tubes (n=28; n=7 cancer) are imaged; we present methods for the calculation of and analyze eleven imaging biomarkers related to fluorescence, optical attenuation, and OCT texture for their potential to detect tubo-ovarian cancers and other lesions of interest. We visualize folded plicae, vessel-like structures, tissue layering, hemosiderin deposits, and regions of fibrotic change. High grade serous ovarian carcinoma appears as reduced autofluorescence paired with homogenous OCT and reduced mean optical attenuation. Specimens containing a cancerous lesion demonstrate significant increase in median autofluorescence intensity and decrease in entropy compared specimens with no lesion. Non-cancerous specimens demonstrate an increase in optical attenuation in the fimbriae when compared to the isthmus or ampulla. We conclude that this approach shows promise and merits further investigation of diagnostic potential.
- Open Access
Imaging Biomarkers of Oral Dysplasia and Carcinoma Measured with In Vivo Endoscopic Optical Coherence Tomography
Optical coherence tomography is a noninvasive imaging technique that provides three-dimensional visualization of subsurface tissue structures. OCT has been proposed and explored in the literature as a tool to assess oral cancer status, select biopsy sites, or identify surgical margins. Our endoscopic OCT device can generate widefield (centimeters long) imaging of lesions at any location in the oral cavity—but it is challenging for raters to quantitatively assess and score large volumes of data. Leveraging a previously developed epithelial segmentation network, this work develops quantifiable biomarkers that provide direct measurements of tissue properties in three dimensions. We hypothesize that features related to morphology, tissue attenuation, and contrast between tissue layers will be able to provide a quantitative assessment of disease status (dysplasia through carcinoma). This work retrospectively assesses seven biomarkers on a lesion-contralateral matched OCT dataset of the lateral and ventral tongue (40 patients, 70 sites). Epithelial depth and loss of epithelial–stromal boundary visualization provide the strongest discrimination between disease states. The stroma optical attenuation coefficient provides a distinction between benign lesions from dysplasia and carcinoma. The stratification biomarkers visualize subsurface changes, which provides potential for future utility in biopsy site selection or treatment margin delineation.
Open AccessImaging Biomarkers of Oral Dysplasia and Carcinoma Measured with In Vivo Endoscopic Optical Coherence Tomography
Optical coherence tomography is a noninvasive imaging technique that provides three-dimensional visualization of subsurface tissue structures. OCT has been proposed and explored in the literature as a tool to assess oral cancer status, select biopsy sites, or identify surgical margins. Our endoscopic OCT device can generate widefield (centimeters long) imaging of lesions at any location in the oral cavity—but it is challenging for raters to quantitatively assess and score large volumes of data. Leveraging a previously developed epithelial segmentation network, this work develops quantifiable biomarkers that provide direct measurements of tissue properties in three dimensions. We hypothesize that features related to morphology, tissue attenuation, and contrast between tissue layers will be able to provide a quantitative assessment of disease status (dysplasia through carcinoma). This work retrospectively assesses seven biomarkers on a lesion-contralateral matched OCT dataset of the lateral and ventral tongue (40 patients, 70 sites). Epithelial depth and loss of epithelial–stromal boundary visualization provide the strongest discrimination between disease states. The stroma optical attenuation coefficient provides a distinction between benign lesions from dysplasia and carcinoma. The stratification biomarkers visualize subsurface changes, which provides potential for future utility in biopsy site selection or treatment margin delineation.
- Open Access
- 9 July 2024
- Published by MDPI AG in Preprints.org
Imaging Biomarkers of Oral Dysplasia and Carcinoma Measured with In Vivo Endoscopic Optical Coherence Tomography
: Optical coherence tomography is a non-invasive imaging technique that provides three-dimensional visualization of subsurface tissue structures. OCT has been proposed and explored in literature as a tool to assess oral cancer status, select biopsy sites, or identify surgical margins. Our endoscopic OCT device can generate widefield (centimeters long) imaging of lesions at any location in the oral cavity – but it is challenging for raters to quantitatively assess and score large volumes of data. Leveraging a previously developed epithelial segmentation network, this work develops quantifiable biomarkers that provide direct measurements of tissue properties in three-dimensions. We hypothesize that features related to morphology, tissue attenuation, and contrast between tissue layers will be able to provide a quantitative assessment of disease status (dysplasia through carcinoma). This work retrospectively assesses seven biomarkers on a lesion-contralateral matched OCT dataset of lateral and ventral tongue (40 patients, 70 sites). Epithelial depth and loss of epithelial-stromal boundary visualization provide the strongest discrimination between disease states. The stroma optical attenuation coefficient provides distinction of benign lesions from dysplasia and carcinoma. The stratification biomarkers visualize subsurface changes which provides potential for future utility in biopsy site selection or treatment margin delineation.
- 9 July 2024
- Published by MDPI AG in Preprints.org
Open AccessImaging Biomarkers of Oral Dysplasia and Carcinoma Measured with In Vivo Endoscopic Optical Coherence Tomography
: Optical coherence tomography is a non-invasive imaging technique that provides three-dimensional visualization of subsurface tissue structures. OCT has been proposed and explored in literature as a tool to assess oral cancer status, select biopsy sites, or identify surgical margins. Our endoscopic OCT device can generate widefield (centimeters long) imaging of lesions at any location in the oral cavity – but it is challenging for raters to quantitatively assess and score large volumes of data. Leveraging a previously developed epithelial segmentation network, this work develops quantifiable biomarkers that provide direct measurements of tissue properties in three-dimensions. We hypothesize that features related to morphology, tissue attenuation, and contrast between tissue layers will be able to provide a quantitative assessment of disease status (dysplasia through carcinoma). This work retrospectively assesses seven biomarkers on a lesion-contralateral matched OCT dataset of lateral and ventral tongue (40 patients, 70 sites). Epithelial depth and loss of epithelial-stromal boundary visualization provide the strongest discrimination between disease states. The stroma optical attenuation coefficient provides distinction of benign lesions from dysplasia and carcinoma. The stratification biomarkers visualize subsurface changes which provides potential for future utility in biopsy site selection or treatment margin delineation.
- 12 December 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (26) , 44224-44245
Multipath artifacts enable angular contrast in multimodal endoscopic optical coherence tomography
Multipath artifacts are inherent to double-clad fiber based optical coherence tomography (OCT), appearing as ghost images blurred in the A-line direction. They result from the excitation of higher-order inner-cladding modes in the OCT sample arm which cross-couple into the fundamental mode at discontinuities and thus are detected in single-mode fiber-based interferometers. Historically, multipath artifacts have been regarded as a drawback in single fiber endoscopic multimodal OCT systems as they degrade OCT quality. In this work, we reveal that multipath artifacts can be projected into high-quality two-dimensional en face images which encode high angle backscattering features. Using a combination of experiment and simulation, we characterize the coupling of Mie-range scatterers into the fundamental image (LP01 mode) and higher-order image (multipath artifact). This is validated experimentally through imaging of microspheres with an endoscopic multimodal OCT system. The angular dependence of the fundamental image and higher order image generated by the multipath artifact lays the basis for multipath contrast, a ratiometric measurement of differential coupling which provides information regarding the angular diversity of a sample. Multipath contrast images can be generated from OCT data where multipath artifacts are present, meaning that a wealth of clinical data can be retrospectively examined.
- 12 December 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (26) , 44224-44245
Multipath artifacts enable angular contrast in multimodal endoscopic optical coherence tomography
Multipath artifacts are inherent to double-clad fiber based optical coherence tomography (OCT), appearing as ghost images blurred in the A-line direction. They result from the excitation of higher-order inner-cladding modes in the OCT sample arm which cross-couple into the fundamental mode at discontinuities and thus are detected in single-mode fiber-based interferometers. Historically, multipath artifacts have been regarded as a drawback in single fiber endoscopic multimodal OCT systems as they degrade OCT quality. In this work, we reveal that multipath artifacts can be projected into high-quality two-dimensional en face images which encode high angle backscattering features. Using a combination of experiment and simulation, we characterize the coupling of Mie-range scatterers into the fundamental image (LP01 mode) and higher-order image (multipath artifact). This is validated experimentally through imaging of microspheres with an endoscopic multimodal OCT system. The angular dependence of the fundamental image and higher order image generated by the multipath artifact lays the basis for multipath contrast, a ratiometric measurement of differential coupling which provides information regarding the angular diversity of a sample. Multipath contrast images can be generated from OCT data where multipath artifacts are present, meaning that a wealth of clinical data can be retrospectively examined.
- 24 January 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (3) , 4465-4481
Triple-clad W-type fiber mitigates multipath artifacts in multimodal optical coherence tomography
Multimodal endoscopic optical coherence tomography (OCT) can be implemented with double-clad fiber by using the presumed single-mode core for OCT and the higher numerical aperture cladding for a secondary modality. However, the quality of OCT in double-clad fiber (DCF) based systems is compromised by the introduction of multipath artifacts that are nt present in single-mode fiber OCT systems. Herein, the mechanisms for multipath artifacts in DCF are linked to its modal contents using a commercial software package and experimental measurement. A triple-clad W-type fiber is proposed as a method for achieving multimodal imaging with single-mode quality OCT in an endoscopic system. Simulations of the modal contents of a W-type fiber are compared to DCF and single-mode fiber. Finally, a W-Type fiber rotary catheter is used in a DCF-based endoscopic OCT and autofluorescence imaging (AFI) system to demonstrate multipath artifact free OCT and AFI of a human fingertip.
- 24 January 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (3) , 4465-4481
Triple-clad W-type fiber mitigates multipath artifacts in multimodal optical coherence tomography
Multimodal endoscopic optical coherence tomography (OCT) can be implemented with double-clad fiber by using the presumed single-mode core for OCT and the higher numerical aperture cladding for a secondary modality. However, the quality of OCT in double-clad fiber (DCF) based systems is compromised by the introduction of multipath artifacts that are nt present in single-mode fiber OCT systems. Herein, the mechanisms for multipath artifacts in DCF are linked to its modal contents using a commercial software package and experimental measurement. A triple-clad W-type fiber is proposed as a method for achieving multimodal imaging with single-mode quality OCT in an endoscopic system. Simulations of the modal contents of a W-type fiber are compared to DCF and single-mode fiber. Finally, a W-Type fiber rotary catheter is used in a DCF-based endoscopic OCT and autofluorescence imaging (AFI) system to demonstrate multipath artifact free OCT and AFI of a human fingertip.
- 1 January 2023
- Published by Optica Publishing Group
- p. DW1A.4
Multipath Artifacts in Single-Fiber Endoscopic Multimodal Optical Coherence Tomography Provide Angular Contrast
A novel method of imaging which exploits multipath image artifact in multimodal OCT is proposed. Experiments explore using the contrast between en face projections of the OCT image and multipath artifact to measure backscattering angle.
- 1 January 2023
- Published by Optica Publishing Group
- p. DW1A.4
Multipath Artifacts in Single-Fiber Endoscopic Multimodal Optical Coherence Tomography Provide Angular Contrast
A novel method of imaging which exploits multipath image artifact in multimodal OCT is proposed. Experiments explore using the contrast between en face projections of the OCT image and multipath artifact to measure backscattering angle.
- 9 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 39 (17) , 5573-5581
Higher-Order Core-Like Modes in Double-Clad Fiber Contribute to Multipath Artifacts in Optical Coherence Tomography
Double-clad fiber (DCF) has enabled the combination of endoscopic optical coherence tomography (OCT) with secondary optical modalities. While DCF offers an additional optical channel, it is widely understood that its use reduces the quality of OCT owing to the introduction of multipath artifacts. We show here that an unexpected higher-order mode (HOM) with its energy confined to the DCF core can contribute to these artifacts. The existence of this HOM is confirmed using the spatially and spectrally (S 2 ) resolved imaging method. The group delay difference of the HOM is shown to be consistent with the delay of the diffuse ghost artifact in DCF-acquired OCT images.
- 9 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 39 (17) , 5573-5581
Higher-Order Core-Like Modes in Double-Clad Fiber Contribute to Multipath Artifacts in Optical Coherence Tomography
Double-clad fiber (DCF) has enabled the combination of endoscopic optical coherence tomography (OCT) with secondary optical modalities. While DCF offers an additional optical channel, it is widely understood that its use reduces the quality of OCT owing to the introduction of multipath artifacts. We show here that an unexpected higher-order mode (HOM) with its energy confined to the DCF core can contribute to these artifacts. The existence of this HOM is confirmed using the spatially and spectrally (S 2 ) resolved imaging method. The group delay difference of the HOM is shown to be consistent with the delay of the diffuse ghost artifact in DCF-acquired OCT images.