Rania A. Sharif
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rania A. Sharif has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Abdul Ahmed
Department of Prosthodontics, College of Dentistry King Khalid University, Abha, Saudi Arabia
1 shared publication Ahmed Babiker Mohamed Ali
Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
1 shared publicationAshfaq Yaqoob
Department of Prosthodontics, College of Dentistry King Khalid University, Abha, Saudi Arabia
1 shared publicationAsim Elsir Elmahdi
Department of Prosthodontics, College of Dentistry King Khalid University, Abha, Saudi Arabia
1 shared publicationFatimah S. Almutairi
King Khalid University, Khamis Mushait, Abha, Saudi Arabia
1 shared publicationGhazala Suleman
Department of Prosthodontics, College of Dentistry King Khalid University, Abha, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 29 November 2025
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 31, e949377
Surface Conditioning Methods and Their Effects on Micro-Tensile Bond Strength and Micro-Chemical Properties of Glass-Infiltrated Zirconia: An In Vitro Study
BACKGROUND Surface conditioning methods play a critical role in enhancing adhesion by creating micro-mechanical and chemical bonds between resin cement and ceramics. This study aimed to evaluate the effects of different surface treatments on micro-tensile bond strength (MTBS) between resin cement and glass-infiltrated zirconia (GLZR), as well as surface changes in topography, roughness, and elemental properties assessed by energy-dispersive X-ray analysis (EDAX). MATERIAL AND METHODS Thirty GLZR blocks were fabricated and divided into 3 groups (n=10) according to the applied surface treatment: laboratory grit-blasting (LGB), laboratory silica coating (LSC), and hydrofluoric acid etching (HFAE). After treatment, specimens were bonded to composite blocks with resin cement, and MTBS was tested using a universal testing machine. Surface roughness was measured; morphological and elemental changes were examined by scanning electron microscopy (SEM) and EDAX. RESULTS The LSC group exhibited the highest MTBS (28.23±1.53 MPa), followed by the LGB group (20.27±2.33 MPa) and the HFAE group (10.41±1.46 MPa). Surface roughness was highest in the LGB group (Ra=9.34±1.23 μm). SEM analysis revealed prominent crater formation in the LGB and LSC groups, whereas the HFAE group showed minimal topographic change. EDAX indicated increased silica content in the LSC group and reduced zirconia content in the LGB group; these findings were linked to enhanced chemical bonding. CONCLUSIONS Among the tested surface treatments, laboratory silica coating significantly improved both surface chemistry and MTBS, making it the most effective method for strengthening resin-zirconia adhesion.
- 29 November 2025
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 31, e949377
Open AccessSurface Conditioning Methods and Their Effects on Micro-Tensile Bond Strength and Micro-Chemical Properties of Glass-Infiltrated Zirconia: An In Vitro Study
BACKGROUND Surface conditioning methods play a critical role in enhancing adhesion by creating micro-mechanical and chemical bonds between resin cement and ceramics. This study aimed to evaluate the effects of different surface treatments on micro-tensile bond strength (MTBS) between resin cement and glass-infiltrated zirconia (GLZR), as well as surface changes in topography, roughness, and elemental properties assessed by energy-dispersive X-ray analysis (EDAX). MATERIAL AND METHODS Thirty GLZR blocks were fabricated and divided into 3 groups (n=10) according to the applied surface treatment: laboratory grit-blasting (LGB), laboratory silica coating (LSC), and hydrofluoric acid etching (HFAE). After treatment, specimens were bonded to composite blocks with resin cement, and MTBS was tested using a universal testing machine. Surface roughness was measured; morphological and elemental changes were examined by scanning electron microscopy (SEM) and EDAX. RESULTS The LSC group exhibited the highest MTBS (28.23±1.53 MPa), followed by the LGB group (20.27±2.33 MPa) and the HFAE group (10.41±1.46 MPa). Surface roughness was highest in the LGB group (Ra=9.34±1.23 μm). SEM analysis revealed prominent crater formation in the LGB and LSC groups, whereas the HFAE group showed minimal topographic change. EDAX indicated increased silica content in the LSC group and reduced zirconia content in the LGB group; these findings were linked to enhanced chemical bonding. CONCLUSIONS Among the tested surface treatments, laboratory silica coating significantly improved both surface chemistry and MTBS, making it the most effective method for strengthening resin-zirconia adhesion.
- Open Access
- 9 June 2021
- Published by Springer Nature in BMC Oral Health
- Vol. 21 (1) , 1-10
The accuracy of gypsum casts obtained from the disinfected extended-pour alginate impressions through prolonged storage times
Background: Manufacturers of the extended-pour alginates claimed their dimensional stability through prolonged storage. No data confirmed the ability of these materials to maintain their dimensions and the reproduced oral details following their chemical disinfection. Therefore, this study evaluated the dimensional stability and surface detail reproduction of gypsum casts obtained from disinfected extended-pour alginate impressions through different storage time intervals. Methods: Two hundred and forty three hydrocolloid impressions were made from one conventional (Tropicalgin) and two extended-pour (Hydrogum 5 and Chromaprint premium) alginates. These impressions were subjected to none, spray and immersion disinfection before their storage in 100% humidity for 0, 72 and 120 h. The dimensional stability and the surface detail reproduction were indirectly evaluated under low angle illumination on the resulted gypsum casts. At α = 0.05, the parametric dimensional stability data were analyzed using One-Way ANOVA and Tukey’s comparisons, while the nonparametric detail reproduction data were analyzed using KrusKal Wallis and Mann–Whitney's tests. Results: All gypsum casts exhibited a degree of expansion; however, the recorded expansion values did not differ between test categories (P > 0.05). Generally, casts obtained from spray-disinfected impressions showed lower detail accuracy (P < 0.05). Immersion-disinfected extended-pour alginates produced casts with better detail accuracy following 120 h of storage (P < 0.05). Conclusion: All alginates materials offer comparable cast dimensions under different testing circumstances. Extended-pour alginates offer casts with superior surface details following their immersion disinfection and 120 h of storage. Spray-disinfection using 5.25% sodium hypochlorite affects the surface details of casts obtained from conventional and extended-pour alginates adversely.
- 9 June 2021
- Published by Springer Nature in BMC Oral Health
- Vol. 21 (1) , 1-10
Open AccessThe accuracy of gypsum casts obtained from the disinfected extended-pour alginate impressions through prolonged storage times
Background: Manufacturers of the extended-pour alginates claimed their dimensional stability through prolonged storage. No data confirmed the ability of these materials to maintain their dimensions and the reproduced oral details following their chemical disinfection. Therefore, this study evaluated the dimensional stability and surface detail reproduction of gypsum casts obtained from disinfected extended-pour alginate impressions through different storage time intervals. Methods: Two hundred and forty three hydrocolloid impressions were made from one conventional (Tropicalgin) and two extended-pour (Hydrogum 5 and Chromaprint premium) alginates. These impressions were subjected to none, spray and immersion disinfection before their storage in 100% humidity for 0, 72 and 120 h. The dimensional stability and the surface detail reproduction were indirectly evaluated under low angle illumination on the resulted gypsum casts. At α = 0.05, the parametric dimensional stability data were analyzed using One-Way ANOVA and Tukey’s comparisons, while the nonparametric detail reproduction data were analyzed using KrusKal Wallis and Mann–Whitney's tests. Results: All gypsum casts exhibited a degree of expansion; however, the recorded expansion values did not differ between test categories (P > 0.05). Generally, casts obtained from spray-disinfected impressions showed lower detail accuracy (P < 0.05). Immersion-disinfected extended-pour alginates produced casts with better detail accuracy following 120 h of storage (P < 0.05). Conclusion: All alginates materials offer comparable cast dimensions under different testing circumstances. Extended-pour alginates offer casts with superior surface details following their immersion disinfection and 120 h of storage. Spray-disinfection using 5.25% sodium hypochlorite affects the surface details of casts obtained from conventional and extended-pour alginates adversely.