Diogo Filipe Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Diogo Filipe Silva has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Steffen Leonhardt
RWTH Aachen University
4 shared publications Steffen Leonhardt
Department of Circuit Theory , CTU Prague , Czechia
3 shared publicationsChristian Putensen
Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Germany
2 shared publicationsThomas Muders
Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Germany
2 shared publications- Benjamin Hentze
Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, 53127 Bonn, Germany
1 shared publication - Christoph Hoog Antink
KIS*MED (AI Systems in Medicine Lab), Technische Universität Darmstadt, Darmstadt, Germany
1 shared publication
Latest Publications
- Open Access
Real-Time Subject-Specific Predictive Modeling of PPG Signals for Artifact-Resilient SpO2 Estimation Under Hypoxia
Photoplethysmography (PPG) is widely used in health monitoring, but its reliability is often compromised by artifacts, limiting accurate peripheral arterial oxygen saturation (SpO2) estimation. Moreover, physiological and demographic factors can substantially alter PPG waveform morphology. We propose a lightweight, real-time predictive modeling approach that adapts to subject-specific PPG signal dynamics to improve monitoring robustness under conditions prone to artifacts. A total of 459 min of dual-wavelength PPG signals, together with reference SpO2 values, were collected from 17 healthy volunteers (2 female, 15 male, mean age years old) undergoing controlled desaturation in the 85–100% range after being instructed to remain still. Cardiac pulses were segmented and decomposed into AC and DC components, and the adequacy of several signal models, ranging from sums of Gaussians to Fourier series, and polynomial expansions of different orders, was evaluated. A space of representative signal features was built from the best-performing model, and used to generate machine learning-based predictions for each pulse using the preceding four clean pulses. Predicted pulses could be directly compared with their originals, enabling accurate error estimation without simulated data. The predicted signals closely matched the originals, achieving mean scores above 0.9, and an SpO2 estimation RMSE of 1.28%. In practical use, the same approach could be applied to overcome artifact-corrupted segments if combined with a signal quality assessment module. Therefore, this algorithm provides a promising pathway toward more reliable SpO2 monitoring in wearable systems, particularly under hypoxic conditions.Open AccessReal-Time Subject-Specific Predictive Modeling of PPG Signals for Artifact-Resilient SpO2 Estimation Under Hypoxia
Photoplethysmography (PPG) is widely used in health monitoring, but its reliability is often compromised by artifacts, limiting accurate peripheral arterial oxygen saturation (SpO2) estimation. Moreover, physiological and demographic factors can substantially alter PPG waveform morphology. We propose a lightweight, real-time predictive modeling approach that adapts to subject-specific PPG signal dynamics to improve monitoring robustness under conditions prone to artifacts. A total of 459 min of dual-wavelength PPG signals, together with reference SpO2 values, were collected from 17 healthy volunteers (2 female, 15 male, mean age years old) undergoing controlled desaturation in the 85–100% range after being instructed to remain still. Cardiac pulses were segmented and decomposed into AC and DC components, and the adequacy of several signal models, ranging from sums of Gaussians to Fourier series, and polynomial expansions of different orders, was evaluated. A space of representative signal features was built from the best-performing model, and used to generate machine learning-based predictions for each pulse using the preceding four clean pulses. Predicted pulses could be directly compared with their originals, enabling accurate error estimation without simulated data. The predicted signals closely matched the originals, achieving mean scores above 0.9, and an SpO2 estimation RMSE of 1.28%. In practical use, the same approach could be applied to overcome artifact-corrupted segments if combined with a signal quality assessment module. Therefore, this algorithm provides a promising pathway toward more reliable SpO2 monitoring in wearable systems, particularly under hypoxic conditions. - 2 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (11) , 3288-3299
Adaptive Cardiorespiratory Separation With Harmonic Models and Filters: The Case of Electrical Impedance Tomography
Cardiorespiratory monitoring methods are vital in clinical and personal healthcare contexts, continuously delivering comprehensive insights into patient health. Among them, electrical impedance tomography, a non-invasive imaging modality, uniquely enables spatially resolved, real-time monitoring of both cardiac and respiratory functions. However, separating cardiac and respiratory signals remains a challenge due to spectral and spatial overlap, heart-lung interactions and nonstationarity. Existing signal processing techniques face limitations in adaptiveness, harmonic overlap handling, and real-time feasibility, restricting their clinical adoption. This work introduces two novel adaptive model-based approaches derived from a harmonic framework inspired by source-filter theory: harmonic least-squares, a deterministic estimator; and harmonically-constrained filtering, which employs harmonic priors and noise covariance approximations towards optimal separation. These algorithms were systematically validated using extensive synthetic and real-world datasets across diverse clinical scenarios. Monte Carlo simulations with a dynamic synthesizer and machine learning surrogate models provided robust performance evaluations, with insights into algorithm behavior through accumulated local effect plots. The proposed methods demonstrated superior performance compared to state-of-the-art approaches and achieved real-time processing capability, making them promising for integration into medical devices. Despite these advancements, further improvements in noise modelling, performance guarantees, and processing efficiency remain potential areas for future development.
- 2 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (11) , 3288-3299
Adaptive Cardiorespiratory Separation With Harmonic Models and Filters: The Case of Electrical Impedance Tomography
Cardiorespiratory monitoring methods are vital in clinical and personal healthcare contexts, continuously delivering comprehensive insights into patient health. Among them, electrical impedance tomography, a non-invasive imaging modality, uniquely enables spatially resolved, real-time monitoring of both cardiac and respiratory functions. However, separating cardiac and respiratory signals remains a challenge due to spectral and spatial overlap, heart-lung interactions and nonstationarity. Existing signal processing techniques face limitations in adaptiveness, harmonic overlap handling, and real-time feasibility, restricting their clinical adoption. This work introduces two novel adaptive model-based approaches derived from a harmonic framework inspired by source-filter theory: harmonic least-squares, a deterministic estimator; and harmonically-constrained filtering, which employs harmonic priors and noise covariance approximations towards optimal separation. These algorithms were systematically validated using extensive synthetic and real-world datasets across diverse clinical scenarios. Monte Carlo simulations with a dynamic synthesizer and machine learning surrogate models provided robust performance evaluations, with insights into algorithm behavior through accumulated local effect plots. The proposed methods demonstrated superior performance compared to state-of-the-art approaches and achieved real-time processing capability, making them promising for integration into medical devices. Despite these advancements, further improvements in noise modelling, performance guarantees, and processing efficiency remain potential areas for future development.
- Open Access
- 1 January 2025
- Published by Walter de Gruyter GmbH in Journal of Electrical Bioimpedance
- Vol. 16 (1) , 80-88
Early thrombus detection in ECMO with optimized impedance measurements: A simulative study
Extracorporeal oxygenation supports patients with severe cardiac or respiratory failure, with the oxygenator providing critical gas exchange. Thrombus formation in the oxygenator can impair efficiency and increase risks such as hemolysis and embolism, but existing detection methods are limited in accuracy and timeliness. This study introduces a computational bioimpedance approach for early thrombus detection that integrates advanced modeling and machine learning techniques while preserving the oxygenator’s functionality. We developed a finite element model of an oxygenator to simulate bioimpedance measurements using varied electrode configurations. Neural networks optimized electrode placement and injection-measurement patterns, enhancing sensitivity to conductivity changes. A second neural network was trained on simulated data to distinguish between normal and thrombus-affected conditions, achieving an F1-score exceeding 94% in classification tasks. Simulations demonstrated the feasibility of this method, with optimized configurations significantly improving detection accuracy. The findings suggest that computational bioimpedance, combined with neural network optimization, provides a robust framework for automated thrombus detection inside an oxygenator.
- 1 January 2025
- Published by Walter de Gruyter GmbH in Journal of Electrical Bioimpedance
- Vol. 16 (1) , 80-88
Open AccessEarly thrombus detection in ECMO with optimized impedance measurements: A simulative study
Extracorporeal oxygenation supports patients with severe cardiac or respiratory failure, with the oxygenator providing critical gas exchange. Thrombus formation in the oxygenator can impair efficiency and increase risks such as hemolysis and embolism, but existing detection methods are limited in accuracy and timeliness. This study introduces a computational bioimpedance approach for early thrombus detection that integrates advanced modeling and machine learning techniques while preserving the oxygenator’s functionality. We developed a finite element model of an oxygenator to simulate bioimpedance measurements using varied electrode configurations. Neural networks optimized electrode placement and injection-measurement patterns, enhancing sensitivity to conductivity changes. A second neural network was trained on simulated data to distinguish between normal and thrombus-affected conditions, achieving an F1-score exceeding 94% in classification tasks. Simulations demonstrated the feasibility of this method, with optimized configurations significantly improving detection accuracy. The findings suggest that computational bioimpedance, combined with neural network optimization, provides a robust framework for automated thrombus detection inside an oxygenator.
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. PP, 1
Contrast-enhanced EIT robustly tracks regional lung perfusion compared to non-enhanced EIT and pulmonary CT
Regional perfusion monitoring, often performed by pulmonary perfusion computed tomography, is vital in intensive care units. Electrical impedance tomography, repeatable and of non-invasive nature, could provide an attractive alternative. This study compares non-enhanced and contrast-enhanced electrical impedance tomography to computed tomography under induced central to peripheral lung perfusion impairments and cardiac output modulation in 11 animals. A new algorithmic framework using multi-compartment modeling and tracer kinetics was developed to improve perfusion estimation. A multi-resolution mixed models analysis shows electrical impedance tomography agrees poorly with computed tomography in static monitoring, with limits of agreement exceeding relative errors of 100%. For trend tracking,contrast-enhancement with 5.85% NaCl yielded concordance rates above 80%, and over 90% for peripheral impairments, emerging as a robust tracker of coarse to fine perfusion changes. Non-enhanced electrical impedance tomography peaked around 60% under central impairment and cardiac modulation, proving to be less reliable.
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. PP, 1
Contrast-enhanced EIT robustly tracks regional lung perfusion compared to non-enhanced EIT and pulmonary CT
Regional perfusion monitoring, often performed by pulmonary perfusion computed tomography, is vital in intensive care units. Electrical impedance tomography, repeatable and of non-invasive nature, could provide an attractive alternative. This study compares non-enhanced and contrast-enhanced electrical impedance tomography to computed tomography under induced central to peripheral lung perfusion impairments and cardiac output modulation in 11 animals. A new algorithmic framework using multi-compartment modeling and tracer kinetics was developed to improve perfusion estimation. A multi-resolution mixed models analysis shows electrical impedance tomography agrees poorly with computed tomography in static monitoring, with limits of agreement exceeding relative errors of 100%. For trend tracking,contrast-enhancement with 5.85% NaCl yielded concordance rates above 80%, and over 90% for peripheral impairments, emerging as a robust tracker of coarse to fine perfusion changes. Non-enhanced electrical impedance tomography peaked around 60% under central impairment and cardiac modulation, proving to be less reliable.
- 14 May 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (11) , 115004
The gamma-variate in contrast-enhanced imaging: a unified view and method from computed to electrical impedance tomography
Objective. Modern medical imaging plays a vital role in clinical practice, enabling non-invasive visualization of anatomical structures. Dynamic contrast enhancement (DCE) imaging is a technique that uses contrast agents to visualize blood flow dynamics in a time-resolved manner. It can be applied to different modalities, such as computed tomography (CT) and electrical impedance tomography (EIT). This study aims to develop a common theoretical and practical hemodynamic extraction basis for DCE modelling across modalities, based on the gamma-variate function. Approach. The study introduces a framework to generate time-intensity curves for multiple DCE imaging modalities from user-defined hemodynamic parameters. Thus, extensive datasets were simulated for both DCE-CT and EIT, representing different hemodynamic scenarios. Additionally, gamma-variate extensions to account for several physiological effects were detailed in a modality-agnostic manner, and three corresponding fitting strategies, namely nonlinear, linear, and a novel hybrid approach, were implemented and compared on the basis of accuracy of parameter estimation, first pass reconstruction, speed of computation, and failure rate. Main results. As a result, we found the linear method to be the most modality-dependent, exhibiting the greatest bias, variance and failure rates, although remaining the fastest alternative. The hybrid method at least matches the state-of-the-art nonlinear method’s accuracy, while improving its robustness and speed by 10 times. Significance. Our research suggests that the hybrid method may bring noteworthy accuracy and efficiency improvements in handling the high-dimensionality of DCE imaging in general, being a step towards real-time processing. Moreover, our generative model presents a potential asset to produce benchmarking and data augmentation datasets across modalities.
- 14 May 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (11) , 115004
The gamma-variate in contrast-enhanced imaging: a unified view and method from computed to electrical impedance tomography
Objective. Modern medical imaging plays a vital role in clinical practice, enabling non-invasive visualization of anatomical structures. Dynamic contrast enhancement (DCE) imaging is a technique that uses contrast agents to visualize blood flow dynamics in a time-resolved manner. It can be applied to different modalities, such as computed tomography (CT) and electrical impedance tomography (EIT). This study aims to develop a common theoretical and practical hemodynamic extraction basis for DCE modelling across modalities, based on the gamma-variate function. Approach. The study introduces a framework to generate time-intensity curves for multiple DCE imaging modalities from user-defined hemodynamic parameters. Thus, extensive datasets were simulated for both DCE-CT and EIT, representing different hemodynamic scenarios. Additionally, gamma-variate extensions to account for several physiological effects were detailed in a modality-agnostic manner, and three corresponding fitting strategies, namely nonlinear, linear, and a novel hybrid approach, were implemented and compared on the basis of accuracy of parameter estimation, first pass reconstruction, speed of computation, and failure rate. Main results. As a result, we found the linear method to be the most modality-dependent, exhibiting the greatest bias, variance and failure rates, although remaining the fastest alternative. The hybrid method at least matches the state-of-the-art nonlinear method’s accuracy, while improving its robustness and speed by 10 times. Significance. Our research suggests that the hybrid method may bring noteworthy accuracy and efficiency improvements in handling the high-dimensionality of DCE imaging in general, being a step towards real-time processing. Moreover, our generative model presents a potential asset to produce benchmarking and data augmentation datasets across modalities.
- Open Access
- 1 September 2023
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 9 (1) , 387-390
Fast 4D FEM Model for EIT Source Separation Benchmarking
The accurate separation of cardiac and ventilatory contributions to electrical impedance tomography signals is crucial for complete and non-invasive cardiorespiratory monitoring. However, no consensus on a suitable source separation algorithm was achieved despite several proposals due to lacking systematic evaluation. To address this, we propose a benchmarking 4D finite element method generative model for mixed, cardiac, and ventilatory signals. Our model implements dynamic modelling of the heart, lungs, and pulmonary arteries using realistic volume and flow curve templates, along with cardiac and respiratory frequency coupling.We also employed variable alveolar and blood conductivities. The model was able to obtain long recordings faster than comparably complex models while maintaining significant physiological effects and signal properties such as non-stationarity, spatial delays, time and frequency profiles. The realistic physiological model can be used to taxonomize and evaluate source separation algorithms, as well as aid in the development and training of new ones.
- 1 September 2023
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 9 (1) , 387-390
Open AccessFast 4D FEM Model for EIT Source Separation Benchmarking
The accurate separation of cardiac and ventilatory contributions to electrical impedance tomography signals is crucial for complete and non-invasive cardiorespiratory monitoring. However, no consensus on a suitable source separation algorithm was achieved despite several proposals due to lacking systematic evaluation. To address this, we propose a benchmarking 4D finite element method generative model for mixed, cardiac, and ventilatory signals. Our model implements dynamic modelling of the heart, lungs, and pulmonary arteries using realistic volume and flow curve templates, along with cardiac and respiratory frequency coupling.We also employed variable alveolar and blood conductivities. The model was able to obtain long recordings faster than comparably complex models while maintaining significant physiological effects and signal properties such as non-stationarity, spatial delays, time and frequency profiles. The realistic physiological model can be used to taxonomize and evaluate source separation algorithms, as well as aid in the development and training of new ones.
- 25 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (7) , 2521-2532
Copula-Based Data Augmentation on a Deep Learning Architecture for Cardiac Sensor Fusion
In the wake of Big Data, traditional Machine Learn-ing techniques are now often integrated in the clinical workflow. Despite more capable, Deep Learning methods are not equally accepted given their unsatiated need for great amounts of training data and transversal use of the same architectures in fundamentally different areas with weakly-substantiated adaptations. To address the former, a cardiorespiratory signal synthesizer was designed by conditional sampling from a multimodally trained stochastic system of Gaussian copulas integrated in a Markov chain. With respect to the latter, a multi-branch convolutional neural network architecture was conceived to learn the best cardiac sensor-fusion strategy at every abstraction layer. The network was tailored to the tasks of cycle detection and classification for different cardiac modality combinations by a synthesizer-based data augmentation training framework and Bayesian hyperparameter optimization. The synthesizer yielded highly realistic signals in the time, frequency and phase domains for both healthy and pathological heart cycles as well as artifacts of different modalities. Benchmarking suggested that the network is able to surpass previous architectures and data augmentation provided a performance boost in realistic data availability scenarios. These included insufficient training data volume, as low as 150 cycles long, artifact contamination and absence of a classification data type in training.
- 25 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (7) , 2521-2532
Copula-Based Data Augmentation on a Deep Learning Architecture for Cardiac Sensor Fusion
In the wake of Big Data, traditional Machine Learn-ing techniques are now often integrated in the clinical workflow. Despite more capable, Deep Learning methods are not equally accepted given their unsatiated need for great amounts of training data and transversal use of the same architectures in fundamentally different areas with weakly-substantiated adaptations. To address the former, a cardiorespiratory signal synthesizer was designed by conditional sampling from a multimodally trained stochastic system of Gaussian copulas integrated in a Markov chain. With respect to the latter, a multi-branch convolutional neural network architecture was conceived to learn the best cardiac sensor-fusion strategy at every abstraction layer. The network was tailored to the tasks of cycle detection and classification for different cardiac modality combinations by a synthesizer-based data augmentation training framework and Bayesian hyperparameter optimization. The synthesizer yielded highly realistic signals in the time, frequency and phase domains for both healthy and pathological heart cycles as well as artifacts of different modalities. Benchmarking suggested that the network is able to surpass previous architectures and data augmentation provided a performance boost in realistic data availability scenarios. These included insufficient training data volume, as low as 150 cycles long, artifact contamination and absence of a classification data type in training.