Lara San Hipólito Marín
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lara San Hipólito Marín has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Pilar Velasco Bohórquez
Department of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain
3 shared publications - Sofía Hernández Montero
Department of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain
3 shared publications - Álvaro Zubizarreta-Macho
Department of Surgery, Faculty of Medicine and Dentistry, University of Salamanca, 37008 Salamanca, Spain
3 shared publications - José María Montiel-Company
Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
2 shared publications - Agustín Galparsoro Catalán
Department of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain
1 shared publication - Blanca Muñoz Jiménez
Department of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain
1 shared publication
Latest Publications
- Open Access
- 18 February 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (4) , 1062
Influence of Guided Tissue Regeneration Techniques on the Success Rate of Healing of Surgical Endodontic Treatment: A Systematic Review and Network Meta-Analysis
Several regeneration techniques and materials have been proposed for the healing of bone defects after surgical endodontic treatment; however, the existing literature does not provide evidence on the most recommended techniques or materials. The aim of the present systematic review and network meta-analysis (NMA) is to summarize the clinical evidence on the efficacy of guided tissue regeneration techniques (GRTs). The PRISMA recommendations were followed. Four databases were searched up to December 2021. Randomized clinical trials (RCTs) with a minimum follow-up of 6 months were included. The risk of bias was assessed using the Cochrane Collaboration tool. A fixed effects model and frequentist approach were used in the NMA. Direct GRT technique comparisons were combined to estimate indirect comparisons, and the estimated effect size of the comparisons was analyzed using the odds ratio (OR). Inconsistency was assessed with the Q test, with a significance level of p < 0.01, and a net heat plot. A total of 274 articles was identified, and 11 RCTs (6 direct comparisons of 15 techniques) were included in the NMA, which examined 6 GRT techniques: control, Os, PL, MB, MB + Os, and MB + PL. The MB + Os group compared to the control (OR = 3.67, 95% CI: 1.36–9.90) and to the MB group (OR = 3.47, 95% CI: 1.07–11.3) showed statistically significant ORs (p ˂ 0.05). The MB + Os group presented the highest degree of certainly (P-score = 0.93).
- 18 February 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (4) , 1062
Open AccessInfluence of Guided Tissue Regeneration Techniques on the Success Rate of Healing of Surgical Endodontic Treatment: A Systematic Review and Network Meta-Analysis
Several regeneration techniques and materials have been proposed for the healing of bone defects after surgical endodontic treatment; however, the existing literature does not provide evidence on the most recommended techniques or materials. The aim of the present systematic review and network meta-analysis (NMA) is to summarize the clinical evidence on the efficacy of guided tissue regeneration techniques (GRTs). The PRISMA recommendations were followed. Four databases were searched up to December 2021. Randomized clinical trials (RCTs) with a minimum follow-up of 6 months were included. The risk of bias was assessed using the Cochrane Collaboration tool. A fixed effects model and frequentist approach were used in the NMA. Direct GRT technique comparisons were combined to estimate indirect comparisons, and the estimated effect size of the comparisons was analyzed using the odds ratio (OR). Inconsistency was assessed with the Q test, with a significance level of p < 0.01, and a net heat plot. A total of 274 articles was identified, and 11 RCTs (6 direct comparisons of 15 techniques) were included in the NMA, which examined 6 GRT techniques: control, Os, PL, MB, MB + Os, and MB + PL. The MB + Os group compared to the control (OR = 3.67, 95% CI: 1.36–9.90) and to the MB group (OR = 3.47, 95% CI: 1.07–11.3) showed statistically significant ORs (p ˂ 0.05). The MB + Os group presented the highest degree of certainly (P-score = 0.93).
- Open Access
- 26 October 2021
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 11 (11) , 1093
A Replicable and Reproducible Digital Method for Quantifying Maxillary Sinus Airway Changes after Sinus Lifts Using the Lateral Window Approach Technique—A Retrospective Study
In the present retrospective study, we aimed to assess the replicability and reproducibility of a novel digital measurement technique for analyzing the volumes of the left and right maxillary sinuses and the nasal and maxillary sinus airway complex after a sinus lift procedure using the lateral window approach, to provide an accurate measurement technique for easily applying in clinical practice and to allow pre-operative assessment of maxillary sinus lift surgery, avoiding complications and making surgery more predictable. Material and Methods: Thirty patients with partially edentulous posterior maxilla were selected and submitted to bilateral sinus lift using the lateral window approach technique, with grafting materials selected and submitted to cone beam computed tomography (CBCT) scans, both pre- and postoperatively. Then, datasets were uploaded to therapeutic digital planning software to measure the volume of the right and left maxillary sinuses and the nasal and maxillary sinus airway complex. Gage R&R statistical analysis was performed to assess the replicability and reproducibility of the digital measurement technique. Results: The variability attributable to the novel digital measurement technique was 3.4% for replicability and 3.4% for reproducibility of the total variability of the samples. Conclusion: The novel digital method proposed is a replicable and reproducible technique for analyzing the volume of the right and left maxillary sinuses and the nasal and maxillary sinus airway complex after a sinus lift using the lateral window approach technique, allowing an accurate pre-operative assessment of maxillary sinus lift surgery, avoiding complications and making surgery more predictable.
- 26 October 2021
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 11 (11) , 1093
Open AccessA Replicable and Reproducible Digital Method for Quantifying Maxillary Sinus Airway Changes after Sinus Lifts Using the Lateral Window Approach Technique—A Retrospective Study
In the present retrospective study, we aimed to assess the replicability and reproducibility of a novel digital measurement technique for analyzing the volumes of the left and right maxillary sinuses and the nasal and maxillary sinus airway complex after a sinus lift procedure using the lateral window approach, to provide an accurate measurement technique for easily applying in clinical practice and to allow pre-operative assessment of maxillary sinus lift surgery, avoiding complications and making surgery more predictable. Material and Methods: Thirty patients with partially edentulous posterior maxilla were selected and submitted to bilateral sinus lift using the lateral window approach technique, with grafting materials selected and submitted to cone beam computed tomography (CBCT) scans, both pre- and postoperatively. Then, datasets were uploaded to therapeutic digital planning software to measure the volume of the right and left maxillary sinuses and the nasal and maxillary sinus airway complex. Gage R&R statistical analysis was performed to assess the replicability and reproducibility of the digital measurement technique. Results: The variability attributable to the novel digital measurement technique was 3.4% for replicability and 3.4% for reproducibility of the total variability of the samples. Conclusion: The novel digital method proposed is a replicable and reproducible technique for analyzing the volume of the right and left maxillary sinuses and the nasal and maxillary sinus airway complex after a sinus lift using the lateral window approach technique, allowing an accurate pre-operative assessment of maxillary sinus lift surgery, avoiding complications and making surgery more predictable.
- Open Access
Failure Rate, Marginal Bone Loss, and Pink Esthetic with Socket-Shield Technique for Immediate Dental Implant Placement in the Esthetic Zone. A Systematic Review and Meta-Analysis
Aim: To compare the failure rate, marginal bone loss, and pink esthetic for the socket-shield technique and the conventional technique for immediate dental implant placement in the esthetic zone. Material and methods: A systematic literature review and meta-analysis, based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations, of clinical studies that evaluated the failure rate, marginal bone loss, and pink esthetic with the socket-shield technique for immediate dental implant placement in the esthetic zone was performed. A total of 4 databases were consulted in the literature search: PubMed-MEDLINE, Scopus, Embase, and Web of Science. After eliminating duplicated articles and applying the inclusion criteria, 16 articles were selected for the qualitative and quantitative analysis. Results: Four randomized controlled trials, five prospective clinical studies, four retrospective studies, and three case series were included in the meta-analysis. The dental implant failure rate for the socket-shield technique for immediate dental implant placement was 1.37% (95% CI, 0.21–2.54%); however, no statistically significant differences between the conventional and socket-shield technique were found. The estimated mean difference in the marginal bone loss for the socket-shield technique was −0.5 mm (95% CI, −0.82 to −0.18) and statistically significant (p < 0.01), with a high heterogeneity (I2 = 99%). The mean pink esthetic score was 12.27 (Q test = 4.47; p-value = 0.61; I2 = 0%). The difference in pink esthetic between the conventional (n = 55) and socket-shield techniques (n = 55) for immediate dental implant placement was 1.15 (95% CI, 0.73–1.58; Q test = 8.88; p value = 0.11; I2 = 44%). The follow-up time was found to be significant (beta coefficient = 0.023; R2 = 85.6%; QM = 3.82; p = 0.049) for the PES for the socket-shield technique. Conclusions: Within the limitations of this systematic review with meta-analysis, the dental implant failure rate did not differ between the socket-shield technique and conventional technique for immediate implant placement in the esthetic zone. However, a lower marginal bone loss and higher pink esthetic scores were found for the socket-shield technique compared to the conventional technique.
Open AccessFailure Rate, Marginal Bone Loss, and Pink Esthetic with Socket-Shield Technique for Immediate Dental Implant Placement in the Esthetic Zone. A Systematic Review and Meta-Analysis
Aim: To compare the failure rate, marginal bone loss, and pink esthetic for the socket-shield technique and the conventional technique for immediate dental implant placement in the esthetic zone. Material and methods: A systematic literature review and meta-analysis, based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations, of clinical studies that evaluated the failure rate, marginal bone loss, and pink esthetic with the socket-shield technique for immediate dental implant placement in the esthetic zone was performed. A total of 4 databases were consulted in the literature search: PubMed-MEDLINE, Scopus, Embase, and Web of Science. After eliminating duplicated articles and applying the inclusion criteria, 16 articles were selected for the qualitative and quantitative analysis. Results: Four randomized controlled trials, five prospective clinical studies, four retrospective studies, and three case series were included in the meta-analysis. The dental implant failure rate for the socket-shield technique for immediate dental implant placement was 1.37% (95% CI, 0.21–2.54%); however, no statistically significant differences between the conventional and socket-shield technique were found. The estimated mean difference in the marginal bone loss for the socket-shield technique was −0.5 mm (95% CI, −0.82 to −0.18) and statistically significant (p < 0.01), with a high heterogeneity (I2 = 99%). The mean pink esthetic score was 12.27 (Q test = 4.47; p-value = 0.61; I2 = 0%). The difference in pink esthetic between the conventional (n = 55) and socket-shield techniques (n = 55) for immediate dental implant placement was 1.15 (95% CI, 0.73–1.58; Q test = 8.88; p value = 0.11; I2 = 44%). The follow-up time was found to be significant (beta coefficient = 0.023; R2 = 85.6%; QM = 3.82; p = 0.049) for the PES for the socket-shield technique. Conclusions: Within the limitations of this systematic review with meta-analysis, the dental implant failure rate did not differ between the socket-shield technique and conventional technique for immediate implant placement in the esthetic zone. However, a lower marginal bone loss and higher pink esthetic scores were found for the socket-shield technique compared to the conventional technique.