Chubin He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chubin He has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Xiuru Xu
Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518000, China
5 shared publications - Zhengchun Peng
Center for Stretchable Electronics and Nano Sensors, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
4 shared publications - Feng Luo
State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology Sichuan University Chengdu China
2 shared publications - Hao Wang
State Key Laboratory of Radio Frequency Heterogeneous Integration, College of Mechatronics and Control Engineering, Shenzhen University, Shenzhen, China
2 shared publications - Xiuru Xu
Guangdong Provincial Key Laboratory of Micro/Nano Optomechatronic Engineering, College of Mechatronics and Control Engineering, Shenzhen University, Shenzhen 518060, China
2 shared publications - Yang Cui
Center of Stretchable Electronics and Nanosensors, School of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China
1 shared publication
Latest Publications
- Open Access
Hybrid Conductive Hydrogels Reinforced by Core–Shell PANi@PAN Nanofibers for Resilient Electromechanical Stability at Subzero Temperatures
Conductive hydrogels are attractive for flexible electronics, but their practical use is often limited by resistance drift during repeated deformation and performance degradation at low temperatures. Here, core–shell polyaniline-coated polyacrylonitrile (PANi@PAN) electrospun nanofibers were incorporated into a polyacrylamide/hydroxypropyl cellulose (PAM/HPC) hydrogel matrix to construct a hybrid conductive network. The PANi shell serves as an electronic pathway alongside ionic conduction in the hydrated polymer network, leading to markedly improved electromechanical stability. The resistance drift is about 11% after 2000 stretching–relaxation cycles at 0–100% strain, about 12 times lower than that of the nanofiber-free hydrogel. Stable electrical responses are maintained under large deformation, with a resistance drift as low as 3.3% over a strain range of 0–400%. The hydrogels show a conductivity of 0.32 S m−1 while retaining high stretchability (>600%). An ethylene glycol/water binary solvent is used to suppress ice formation and improve moisture retention, allowing stable electromechanical performance at −15 °C over 500 cycles. The hydrogel also adheres reliably to human skin (about 10.25 kPa) and functions as a conformal strain sensor without extra fixation.
Open AccessHybrid Conductive Hydrogels Reinforced by Core–Shell PANi@PAN Nanofibers for Resilient Electromechanical Stability at Subzero Temperatures
Conductive hydrogels are attractive for flexible electronics, but their practical use is often limited by resistance drift during repeated deformation and performance degradation at low temperatures. Here, core–shell polyaniline-coated polyacrylonitrile (PANi@PAN) electrospun nanofibers were incorporated into a polyacrylamide/hydroxypropyl cellulose (PAM/HPC) hydrogel matrix to construct a hybrid conductive network. The PANi shell serves as an electronic pathway alongside ionic conduction in the hydrated polymer network, leading to markedly improved electromechanical stability. The resistance drift is about 11% after 2000 stretching–relaxation cycles at 0–100% strain, about 12 times lower than that of the nanofiber-free hydrogel. Stable electrical responses are maintained under large deformation, with a resistance drift as low as 3.3% over a strain range of 0–400%. The hydrogels show a conductivity of 0.32 S m−1 while retaining high stretchability (>600%). An ethylene glycol/water binary solvent is used to suppress ice formation and improve moisture retention, allowing stable electromechanical performance at −15 °C over 500 cycles. The hydrogel also adheres reliably to human skin (about 10.25 kPa) and functions as a conformal strain sensor without extra fixation.
- Open Access
Dual-Mode Electrical–Optical Nanocomposite Hydrogel with Enhanced Upconversion Luminescence for Strain and pH Sensing
A dual-mode electrical–optical nanocomposite hydrogel is developed by integrating carboxyl-modified upconversion nanoparticles (UCNPs-COOH) and quaternized chitosan (CQAS) into a polyacrylamide (PAAm) covalent network. The hydrogel exhibits high optical transparency (>90% in the visible region), excellent mechanical properties (fracture strain of 1742%, tensile strength of 0.85 MPa, toughness of 6.57 MJ/m3), and robust adhesion to various substrates. The synergistic covalent–noncovalent hybrid network enables efficient energy dissipation, while CQAS-enhanced dispersion of UCNPs significantly improves upconversion luminescence intensity and stability, as evidenced by prolonged fluorescence lifetime from 0.564 ms to 0.691 ms at 539 nm. Leveraging distinct electrical and optical signal transduction pathways, the hydrogel functions as a highly sensitive resistive strain sensor with multistage gauge factors up to 13.85 and excellent cyclic stability over 1200 loading–unloading cycles at 100% strain for human motion monitoring. It also serves as a ratiometric optical pH sensor over a broad range (pH 1–13) based on phenolphthalein-sensitized upconversion luminescence, with excellent repeatability. By integrating real-time resistance responses with optical readouts within a single soft material, this work demonstrates a reliable dual-mode sensing strategy for simultaneous mechanical and chemical monitoring, holding promise for wearable electronics, smart healthcare, and environment-responsive sensing systems.
Open AccessDual-Mode Electrical–Optical Nanocomposite Hydrogel with Enhanced Upconversion Luminescence for Strain and pH Sensing
A dual-mode electrical–optical nanocomposite hydrogel is developed by integrating carboxyl-modified upconversion nanoparticles (UCNPs-COOH) and quaternized chitosan (CQAS) into a polyacrylamide (PAAm) covalent network. The hydrogel exhibits high optical transparency (>90% in the visible region), excellent mechanical properties (fracture strain of 1742%, tensile strength of 0.85 MPa, toughness of 6.57 MJ/m3), and robust adhesion to various substrates. The synergistic covalent–noncovalent hybrid network enables efficient energy dissipation, while CQAS-enhanced dispersion of UCNPs significantly improves upconversion luminescence intensity and stability, as evidenced by prolonged fluorescence lifetime from 0.564 ms to 0.691 ms at 539 nm. Leveraging distinct electrical and optical signal transduction pathways, the hydrogel functions as a highly sensitive resistive strain sensor with multistage gauge factors up to 13.85 and excellent cyclic stability over 1200 loading–unloading cycles at 100% strain for human motion monitoring. It also serves as a ratiometric optical pH sensor over a broad range (pH 1–13) based on phenolphthalein-sensitized upconversion luminescence, with excellent repeatability. By integrating real-time resistance responses with optical readouts within a single soft material, this work demonstrates a reliable dual-mode sensing strategy for simultaneous mechanical and chemical monitoring, holding promise for wearable electronics, smart healthcare, and environment-responsive sensing systems.
- Open Access
Linearly Responsive, Reliable, and Stretchable Strain Sensors Based on Polyaniline Composite Hydrogels
Conductive hydrogels are ideal for flexible strain sensors, yet their practical use is often limited by water evaporation, signal hysteresis, and structural instability, which impair linearity, durability, and long-term reliability. To overcome these challenges, we developed a robust multiple-network hydrogel composed of poly(vinyl alcohol) (PVA), polyacrylic acid (PAA), in situ polymerized polyaniline (PANi), and the ionic liquid [EMIM][TFSI]. The resulting composite exhibits an exceptional linear piezoresistive response across its entire working range—from rest to fracture strain of 290%—together with high conductivity (0.68 S/cm), fast response/recovery (0.34 s/0.35 s), and a maximum gauge factor of 2.78. Mechanically robust (tensile strength ≈ 3.7 MPa, modulus ≈ 1.3 MPa), the hydrogel also demonstrates outstanding cyclic durability, withstanding over 12,000 stretching–relaxation cycles, and markedly improved dehydration resistance, retaining about 60% of its mass after 3 days at room temperature. This work provides a holistic material solution for developing high-performance, reliable strain sensors suitable for wearable electronics and soft robotics.
Open AccessLinearly Responsive, Reliable, and Stretchable Strain Sensors Based on Polyaniline Composite Hydrogels
Conductive hydrogels are ideal for flexible strain sensors, yet their practical use is often limited by water evaporation, signal hysteresis, and structural instability, which impair linearity, durability, and long-term reliability. To overcome these challenges, we developed a robust multiple-network hydrogel composed of poly(vinyl alcohol) (PVA), polyacrylic acid (PAA), in situ polymerized polyaniline (PANi), and the ionic liquid [EMIM][TFSI]. The resulting composite exhibits an exceptional linear piezoresistive response across its entire working range—from rest to fracture strain of 290%—together with high conductivity (0.68 S/cm), fast response/recovery (0.34 s/0.35 s), and a maximum gauge factor of 2.78. Mechanically robust (tensile strength ≈ 3.7 MPa, modulus ≈ 1.3 MPa), the hydrogel also demonstrates outstanding cyclic durability, withstanding over 12,000 stretching–relaxation cycles, and markedly improved dehydration resistance, retaining about 60% of its mass after 3 days at room temperature. This work provides a holistic material solution for developing high-performance, reliable strain sensors suitable for wearable electronics and soft robotics.
- Open Access
- 26 March 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (7) , 1181
Electrospun Nanofibers Hybrid Wrinkled Micropyramidal Architectures for Elastic Self-Powered Tactile and Motion Sensors
Conformable, sensitive, long-lasting, external power supplies-free multifunctional electronics are highly desired for personal healthcare monitoring and artificial intelligence. Herein, we report a series of stretchable, skin-like, self-powered tactile and motion sensors based on single-electrode mode triboelectric nanogenerators. The triboelectric sensors were composed of ultraelastic polyacrylamide (PAAm)/(polyvinyl pyrrolidone) PVP/(calcium chloride) CaCl2 conductive hydrogels and surface-modified silicon rubber thin films. The significant enhancement of electrospun polyvinylidene fluoride (PVDF) nanofiber-modified hierarchically wrinkled micropyramidal architectures for the friction layer was studied. The mechanism of the enhanced output performance of the electrospun PVDF nanofibers and the single-side/double-side wrinkled micropyramidal architectures-based sensors has been discussed in detail. The as-prepared devices exhibited excellent sensitivity of a maximum of 20.1 V/N (or 8.03 V/kPa) as tactile sensors to recognize a wide range of forces from 0.1 N to 30 N at low frequencies. In addition, multiple human motion monitoring was demonstrated, such as knee, finger, wrist, and neck movement and voice recognition. This work shows great potential for skin-like epidermal electronics in long-term medical monitoring and intelligent robot applications.
- 26 March 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (7) , 1181
Open AccessElectrospun Nanofibers Hybrid Wrinkled Micropyramidal Architectures for Elastic Self-Powered Tactile and Motion Sensors
Conformable, sensitive, long-lasting, external power supplies-free multifunctional electronics are highly desired for personal healthcare monitoring and artificial intelligence. Herein, we report a series of stretchable, skin-like, self-powered tactile and motion sensors based on single-electrode mode triboelectric nanogenerators. The triboelectric sensors were composed of ultraelastic polyacrylamide (PAAm)/(polyvinyl pyrrolidone) PVP/(calcium chloride) CaCl2 conductive hydrogels and surface-modified silicon rubber thin films. The significant enhancement of electrospun polyvinylidene fluoride (PVDF) nanofiber-modified hierarchically wrinkled micropyramidal architectures for the friction layer was studied. The mechanism of the enhanced output performance of the electrospun PVDF nanofibers and the single-side/double-side wrinkled micropyramidal architectures-based sensors has been discussed in detail. The as-prepared devices exhibited excellent sensitivity of a maximum of 20.1 V/N (or 8.03 V/kPa) as tactile sensors to recognize a wide range of forces from 0.1 N to 30 N at low frequencies. In addition, multiple human motion monitoring was demonstrated, such as knee, finger, wrist, and neck movement and voice recognition. This work shows great potential for skin-like epidermal electronics in long-term medical monitoring and intelligent robot applications.
- Open Access
- 29 March 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (7) , 1137
A Bilayer Skin-Inspired Hydrogel with Strong Bonding Interface
Conductive hydrogels are widely used in sports monitoring, healthcare, energy storage, and other fields, due to their excellent physical and chemical properties. However, synthesizing a hydrogel with synergistically good mechanical and electrical properties is still challenging. Current fabrication strategies are mainly focused on the polymerization of hydrogels with a single component, with less emphasis on combining and matching different conductive hydrogels. Inspired by the gradient modulus structures of the human skin, we propose a bilayer structure of conductive hydrogels, composed of a spray-coated poly(3,4-dihydrothieno-1,4-dioxin): poly(styrene sulfonate) (PEDOT:PSS) as the bonding interface, a relatively low modulus hydrogel on the top, and a relatively high modulus hydrogel on the bottom. The spray-coated PEDOT:PSS constructs an interlocking interface between the top and bottom hydrogels. Compared to the single layer counterparts, both the mechanical and electrical properties were significantly improved. The as-prepared hydrogel showed outstanding stretchability (1763.85 ± 161.66%), quite high toughness (9.27 ± 0.49 MJ/m3), good tensile strength (0.92 ± 0.08 MPa), and decent elastic modulus (69.16 ± 8.02 kPa). A stretchable strain sensor based on the proposed hydrogel shows good conductivity (1.76 S/m), high sensitivity (a maximum gauge factor of 18.14), and a wide response range (0–1869%). Benefitting from the modulus matching between the two layers of the hydrogels, the interfacial interlocking network, and the patch effect of the PEDOT:PSS, the strain sensor exhibits excellent interface robustness with stable performance (>12,500 cycles). These results indicate that the proposed bilayer conductive hydrogel is a promising material for stretchable electronics, soft robots, and next-generation wearables.
- 29 March 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (7) , 1137
Open AccessA Bilayer Skin-Inspired Hydrogel with Strong Bonding Interface
Conductive hydrogels are widely used in sports monitoring, healthcare, energy storage, and other fields, due to their excellent physical and chemical properties. However, synthesizing a hydrogel with synergistically good mechanical and electrical properties is still challenging. Current fabrication strategies are mainly focused on the polymerization of hydrogels with a single component, with less emphasis on combining and matching different conductive hydrogels. Inspired by the gradient modulus structures of the human skin, we propose a bilayer structure of conductive hydrogels, composed of a spray-coated poly(3,4-dihydrothieno-1,4-dioxin): poly(styrene sulfonate) (PEDOT:PSS) as the bonding interface, a relatively low modulus hydrogel on the top, and a relatively high modulus hydrogel on the bottom. The spray-coated PEDOT:PSS constructs an interlocking interface between the top and bottom hydrogels. Compared to the single layer counterparts, both the mechanical and electrical properties were significantly improved. The as-prepared hydrogel showed outstanding stretchability (1763.85 ± 161.66%), quite high toughness (9.27 ± 0.49 MJ/m3), good tensile strength (0.92 ± 0.08 MPa), and decent elastic modulus (69.16 ± 8.02 kPa). A stretchable strain sensor based on the proposed hydrogel shows good conductivity (1.76 S/m), high sensitivity (a maximum gauge factor of 18.14), and a wide response range (0–1869%). Benefitting from the modulus matching between the two layers of the hydrogels, the interfacial interlocking network, and the patch effect of the PEDOT:PSS, the strain sensor exhibits excellent interface robustness with stable performance (>12,500 cycles). These results indicate that the proposed bilayer conductive hydrogel is a promising material for stretchable electronics, soft robots, and next-generation wearables.
- Open Access
- 19 July 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (7) , 1854
Robust Conductive Hydrogels with Ultrafast Self-Recovery and Nearly Zero Response Hysteresis for Epidermal Sensors
Robust conductive hydrogels are in great demand for the practical applications of smart soft robots, epidermal electronics, and human–machine interactions. We successfully prepared nanoparticles enhanced polyacrylamide/hydroxypropyl guar gum/acryloyl-grafted chitosan quaternary ammonium salt/calcium ions/SiO2 nanoparticles (PHC/Ca2+/SiO2 NPs) conductive hydrogels. Owing to the stable chemical and physical hybrid crosslinking networks and reversible non-covalent interactions, the PHC/Ca2+/SiO2 NPs conductive hydrogel showed good conductivity (~3.39 S/m), excellent toughness (6.71 MJ/m3), high stretchability (2256%), fast self-recovery (80% within 10 s, and 100% within 30 s), and good fatigue resistance. The maximum gauge factor as high as 66.99 was obtained, with a wide detectable strain range (from 0.25% to 500% strain), the fast response (25.00 ms) and recovery time (86.12 ms), excellent negligible response hysteresis, and good response stability. The applications of monitoring the human’s body movements were demonstrated, such as wrist bending and pulse tracking.
- 19 July 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (7) , 1854
Open AccessRobust Conductive Hydrogels with Ultrafast Self-Recovery and Nearly Zero Response Hysteresis for Epidermal Sensors
Robust conductive hydrogels are in great demand for the practical applications of smart soft robots, epidermal electronics, and human–machine interactions. We successfully prepared nanoparticles enhanced polyacrylamide/hydroxypropyl guar gum/acryloyl-grafted chitosan quaternary ammonium salt/calcium ions/SiO2 nanoparticles (PHC/Ca2+/SiO2 NPs) conductive hydrogels. Owing to the stable chemical and physical hybrid crosslinking networks and reversible non-covalent interactions, the PHC/Ca2+/SiO2 NPs conductive hydrogel showed good conductivity (~3.39 S/m), excellent toughness (6.71 MJ/m3), high stretchability (2256%), fast self-recovery (80% within 10 s, and 100% within 30 s), and good fatigue resistance. The maximum gauge factor as high as 66.99 was obtained, with a wide detectable strain range (from 0.25% to 500% strain), the fast response (25.00 ms) and recovery time (86.12 ms), excellent negligible response hysteresis, and good response stability. The applications of monitoring the human’s body movements were demonstrated, such as wrist bending and pulse tracking.
- Open Access
Transparent, Conductive Hydrogels with High Mechanical Strength and Toughness
Transparent, conductive hydrogels with good mechanical strength and toughness are in great demand of the fields of biomedical and future wearable smart electronics. We reported a carboxymethyl chitosan (CMCS)–calcium chloride (CaCl2)/polyacrylamide (PAAm)/poly(N-methylol acrylamide (PNMA) transparent, tough and conductive hydrogel containing a bi-physical crosslinking network through in situ free radical polymerization. It showed excellent light transmittance (>90%), excellent toughness (10.72 MJ/m3), good tensile strength (at break, 2.65 MPa), breaking strain (707%), and high elastic modulus (0.30 MPa). The strain sensing performance is found with high sensitivity (maximum gauge factor 9.18, 0.5% detection limit), wide strain response range, fast response and recovery time, nearly zero hysteresis and good repeatability. This study extends the transparent, tough, conductive hydrogels to provide body-surface wearable devices that can accurately and repeatedly monitor the movement of body joints, including the movements of wrists, elbows and knee joints. This study provided a broad development potential for tough, transparent and conductive hydrogels as body-surface intelligent health monitoring systems and implantable soft electronics.
Open AccessTransparent, Conductive Hydrogels with High Mechanical Strength and Toughness
Transparent, conductive hydrogels with good mechanical strength and toughness are in great demand of the fields of biomedical and future wearable smart electronics. We reported a carboxymethyl chitosan (CMCS)–calcium chloride (CaCl2)/polyacrylamide (PAAm)/poly(N-methylol acrylamide (PNMA) transparent, tough and conductive hydrogel containing a bi-physical crosslinking network through in situ free radical polymerization. It showed excellent light transmittance (>90%), excellent toughness (10.72 MJ/m3), good tensile strength (at break, 2.65 MPa), breaking strain (707%), and high elastic modulus (0.30 MPa). The strain sensing performance is found with high sensitivity (maximum gauge factor 9.18, 0.5% detection limit), wide strain response range, fast response and recovery time, nearly zero hysteresis and good repeatability. This study extends the transparent, tough, conductive hydrogels to provide body-surface wearable devices that can accurately and repeatedly monitor the movement of body joints, including the movements of wrists, elbows and knee joints. This study provided a broad development potential for tough, transparent and conductive hydrogels as body-surface intelligent health monitoring systems and implantable soft electronics.