Pavel Paramonov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pavel Paramonov has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Jan Sijbers
Imec-Vision Lab, Department of Physics, University of Antwerp, Wilrijk, Belgium
5 shared publications - Jan De Beenhouwer
Imec-VisionLab, University of Antwerp, Antwerp, Belgium
4 shared publications Björn De Samber
1 shared publicationDomenico Iuso
1 shared publication- Domenico Iuso
2imec-Vision Lab, University of Antwerp, Universiteitsplein 1, Antwerpen B-2610, Belgium
1 shared publication Jan De Beenhouwer
1 shared publication
Latest Publications
- Open Access
- 1 March 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (3)
GEO-ASTRA: a toolbox for non-conventional XCT scanning and reconstruction
Conventional, circular CT scanning is the standard technique for the large majority of applications. Although being wellestablished and widely applicable, the standard approaches can reach practical limits when inspecting specific samples with specific demands (e.g., high resolution imaging on high aspect-ratio samples). Therefore, non-conventional X-ray CT (NCXCT) scanning approaches can have several benefits above traditional circular scanning methods, such as lower set-up cost in an industrial setting, increased spatial resolution capability, faster and/or more focused scanning. In this contribution, we present some applications of GEO-ASTRA, a toolbox for non-conventional XCT scanning and reconstruction. As a major advantage, the toolbox is general, not system specific. We show its capabilities to work with the FleXCT scanner at imec-Vision Lab, featuring 10 degrees of freedom, including source (vertical/horizontal), sample stage (horizontal, axial, forward/backward, centering, rotation), and detector (vertical, horizontal, forward/backward) motions. It has the ability to generate non-conventional scanning scripts and acquire projection data as such, which can be in turn reconstructed using the GEO-ASTRA toolkit, using algebraic and/or analytical reconstruction. We show the general workflow for including specific parameters of the NC-XCT trajectories in ASTRA for the FleXCT system and demonstrate some of the possible scanning geometries and potential industrial applications.
- 1 March 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (3)
Open AccessGEO-ASTRA: a toolbox for non-conventional XCT scanning and reconstruction
Conventional, circular CT scanning is the standard technique for the large majority of applications. Although being wellestablished and widely applicable, the standard approaches can reach practical limits when inspecting specific samples with specific demands (e.g., high resolution imaging on high aspect-ratio samples). Therefore, non-conventional X-ray CT (NCXCT) scanning approaches can have several benefits above traditional circular scanning methods, such as lower set-up cost in an industrial setting, increased spatial resolution capability, faster and/or more focused scanning. In this contribution, we present some applications of GEO-ASTRA, a toolbox for non-conventional XCT scanning and reconstruction. As a major advantage, the toolbox is general, not system specific. We show its capabilities to work with the FleXCT scanner at imec-Vision Lab, featuring 10 degrees of freedom, including source (vertical/horizontal), sample stage (horizontal, axial, forward/backward, centering, rotation), and detector (vertical, horizontal, forward/backward) motions. It has the ability to generate non-conventional scanning scripts and acquire projection data as such, which can be in turn reconstructed using the GEO-ASTRA toolkit, using algebraic and/or analytical reconstruction. We show the general workflow for including specific parameters of the NC-XCT trajectories in ASTRA for the FleXCT system and demonstrate some of the possible scanning geometries and potential industrial applications.
- Open Access
- 20 August 2024
- Published by Elsevier in Precision Engineering
- Vol. 90, 108-121
PACS: Projection-driven with Adaptive CADs X-ray Scatter compensation for additive manufacturing inspection
- 20 August 2024
- Published by Elsevier in Precision Engineering
- Vol. 90, 108-121
Open AccessPACS: Projection-driven with Adaptive CADs X-ray Scatter compensation for additive manufacturing inspection
- 5 March 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (6) , 10005-10021
Edge illumination x-ray phase contrast simulations using the CAD-ASTRA toolbox
Edge illumination x-ray phase contrast imaging (XPCI) provides increased contrast for low absorbing materials compared to attenuation images and sheds light on the material microstructure through dark field contrast. To apply XPCI in areas such as non-destructive testing and inline inspection, where scanned samples are increasingly compared to simulated reference images, accurate and efficient simulation software is required. However, currently available simulators rely on expensive Monte Carlo techniques or wave-optics frameworks, resulting in long simulation times. Furthermore, these simulators are often not optimized to work with computer-aided design (CAD) models, a common and memory-efficient method to represent manufactured objects, hindering their integration in an inspection pipeline. In this work, we address these shortcomings by introducing an edge illumination XPCI simulation framework built upon the recently developed CAD-ASTRA toolbox. CAD-ASTRA allows for the efficient simulation of x-ray projections from CAD models through GPU-accelerated ray tracing and supports ray refraction in a geometric optics framework. The edge illumination implementation is validated and its performance is benchmarked against GATE, a state-of-the-art Monte Carlo simulator, revealing a simulation speed increase of up to three orders of magnitude, while maintaining high accuracy in the resulting images.
- 5 March 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (6) , 10005-10021
Edge illumination x-ray phase contrast simulations using the CAD-ASTRA toolbox
Edge illumination x-ray phase contrast imaging (XPCI) provides increased contrast for low absorbing materials compared to attenuation images and sheds light on the material microstructure through dark field contrast. To apply XPCI in areas such as non-destructive testing and inline inspection, where scanned samples are increasingly compared to simulated reference images, accurate and efficient simulation software is required. However, currently available simulators rely on expensive Monte Carlo techniques or wave-optics frameworks, resulting in long simulation times. Furthermore, these simulators are often not optimized to work with computer-aided design (CAD) models, a common and memory-efficient method to represent manufactured objects, hindering their integration in an inspection pipeline. In this work, we address these shortcomings by introducing an edge illumination XPCI simulation framework built upon the recently developed CAD-ASTRA toolbox. CAD-ASTRA allows for the efficient simulation of x-ray projections from CAD models through GPU-accelerated ray tracing and supports ray refraction in a geometric optics framework. The edge illumination implementation is validated and its performance is benchmarked against GATE, a state-of-the-art Monte Carlo simulator, revealing a simulation speed increase of up to three orders of magnitude, while maintaining high accuracy in the resulting images.
- 18 January 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (3) , 3425-3439
CAD-ASTRA: a versatile and efficient mesh projector for X-ray tomography with the ASTRA-toolbox
Accurate and fast simulation of X-ray projection data from mesh models has many applications in academia and industry, ranging from 3D X-ray computed tomography (XCT) reconstruction algorithms to radiograph-based object inspection and quality control. While software tools for the simulation of X-ray projection data from mesh models are available, they lack either performance, public availability, flexibility to implement non-standard scanning geometries, or easy integration with existing 3D XCT software. In this paper, we propose CAD-ASTRA, a highly versatile toolbox for fast simulation of X-ray projection data from mesh models. While fully functional as standalone software, it is also compatible with the ASTRA toolbox, an open-source toolbox for flexible tomographic reconstruction. CAD-ASTRA provides three specialized GPU projectors based on state-of-the-art algorithms for 3D rendering, implemented using the NVIDIA CUDA Toolkit and the OptiX engine. First, it enables X-ray phase contrast simulations by modeling refraction through ray tracing. Second, it allows the back-propagation of projective errors to mesh vertices, enabling immediate application in mesh reconstruction, deep learning, and other optimization routines. Finally, CAD-ASTRA allows simulation of polychromatic X-ray projections from heterogeneous objects with a source of finite focal spot size. Use cases on a CAD-based inspection task, a phase contrast experiment, a combined mesh-volumetric data projection, and a mesh reconstruction demonstrate the wide applicability of CAD-ASTRA.
- 18 January 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (3) , 3425-3439
CAD-ASTRA: a versatile and efficient mesh projector for X-ray tomography with the ASTRA-toolbox
Accurate and fast simulation of X-ray projection data from mesh models has many applications in academia and industry, ranging from 3D X-ray computed tomography (XCT) reconstruction algorithms to radiograph-based object inspection and quality control. While software tools for the simulation of X-ray projection data from mesh models are available, they lack either performance, public availability, flexibility to implement non-standard scanning geometries, or easy integration with existing 3D XCT software. In this paper, we propose CAD-ASTRA, a highly versatile toolbox for fast simulation of X-ray projection data from mesh models. While fully functional as standalone software, it is also compatible with the ASTRA toolbox, an open-source toolbox for flexible tomographic reconstruction. CAD-ASTRA provides three specialized GPU projectors based on state-of-the-art algorithms for 3D rendering, implemented using the NVIDIA CUDA Toolkit and the OptiX engine. First, it enables X-ray phase contrast simulations by modeling refraction through ray tracing. Second, it allows the back-propagation of projective errors to mesh vertices, enabling immediate application in mesh reconstruction, deep learning, and other optimization routines. Finally, CAD-ASTRA allows simulation of polychromatic X-ray projections from heterogeneous objects with a source of finite focal spot size. Use cases on a CAD-based inspection task, a phase contrast experiment, a combined mesh-volumetric data projection, and a mesh reconstruction demonstrate the wide applicability of CAD-ASTRA.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 77, 128-132
Fast algorithm for isolated words recognition based on Hidden Markov model stationary distribution
Over the last few decades Hidden Markov models (HMM) became core technology in automatic speech recognition (ASR). Contemporary HMM approach is based on usage of Gaussian mixture models (GMM) as acoustic models that are capable of statistical inference of speech variability. Deep neural networks (DNN) applied to ASR as acoustic models outperformed GMM in large vocabulary speech recognition. However, conventional approaches to ASR are very computationally expensive, what makes it impossible to apply them in voice control systems on low power devices. This paper focuses on the approach to isolated words recognition with reduced computational costs, what makes it feasible for in-place recognition on low computational resources devices. All components of the isolated words recognizer are described. Quantized Mel-frequency cepstral coefficients are used as speech features. The fast algorithm of isolated words recognition is described. It is based on a stationary distribution of Hidden Markov model and has linear computational complexity. Another important feature of the proposed approach is that it requires significantly less memory to store model parameters comparing to HMM-GMM and DNN models. Algorithm performance is evaluated on TIMIT isolated words dataset. The proposed method performance is compared with the results, that showed conventional forward algorithm, HMM-GMM approach and Self-Adjustable Neural Network. Only HMM-GMM outperformed proposed stationary distribution approach.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 77, 128-132
Fast algorithm for isolated words recognition based on Hidden Markov model stationary distribution
Over the last few decades Hidden Markov models (HMM) became core technology in automatic speech recognition (ASR). Contemporary HMM approach is based on usage of Gaussian mixture models (GMM) as acoustic models that are capable of statistical inference of speech variability. Deep neural networks (DNN) applied to ASR as acoustic models outperformed GMM in large vocabulary speech recognition. However, conventional approaches to ASR are very computationally expensive, what makes it impossible to apply them in voice control systems on low power devices. This paper focuses on the approach to isolated words recognition with reduced computational costs, what makes it feasible for in-place recognition on low computational resources devices. All components of the isolated words recognizer are described. Quantized Mel-frequency cepstral coefficients are used as speech features. The fast algorithm of isolated words recognition is described. It is based on a stationary distribution of Hidden Markov model and has linear computational complexity. Another important feature of the proposed approach is that it requires significantly less memory to store model parameters comparing to HMM-GMM and DNN models. Algorithm performance is evaluated on TIMIT isolated words dataset. The proposed method performance is compared with the results, that showed conventional forward algorithm, HMM-GMM approach and Self-Adjustable Neural Network. Only HMM-GMM outperformed proposed stationary distribution approach.
- 9 August 2015
- Published by Springer Nature in Soft Computing
- Vol. 20 (9) , 3455-3460
Simplified scoring methods for HMM-based speech recognition
- 9 August 2015
- Published by Springer Nature in Soft Computing
- Vol. 20 (9) , 3455-3460
Simplified scoring methods for HMM-based speech recognition
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 154-156
Simplified Scoring Methods in HMM Based Speech Recognition
In this paper we present two ways to simplify scoring in Hidden Markov Models (HMM) based speech recognition in order to reduce it's computational complexity. We tested proposed approaches on Russian words recognition and compared results with those that gave recognition using conventional forward algorithm.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 154-156
Simplified Scoring Methods in HMM Based Speech Recognition
In this paper we present two ways to simplify scoring in Hidden Markov Models (HMM) based speech recognition in order to reduce it's computational complexity. We tested proposed approaches on Russian words recognition and compared results with those that gave recognition using conventional forward algorithm.