Grzegorz Świrniak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Grzegorz Świrniak has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Grzegorz Głomb
Wroclaw Univ. of Science and Technology (Poland)
10 shared publications - Janusz Mroczka
Electronic and Photonic Metrology, Wroclaw University of Technology, 50-317 Wroclaw, Poland
5 shared publications
Latest Publications
- Open Access
- 21 November 2024
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 31 (3) , 609-617
Identification of step-index fibers by static light scattering
Accurate characterization of optical fibers is crucial for numerous applications in telecommunications, sensing, and medical diagnostics. In this study, a novel method of sizing of step-index fibers is presented on the basis of the analysis of data on light scattering. This approach integrates mathematical modeling of light scattering by step-index fibers with signal processing and correlation algorithms to extract information on the layered structure of the fiber under test. Practical measurements use of a novel optical system for laboratory-level tests. The results show a clear route to improve non-destructive and efficient fiber characterization in online industrial process control.
- 21 November 2024
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 31 (3) , 609-617
Open AccessIdentification of step-index fibers by static light scattering
Accurate characterization of optical fibers is crucial for numerous applications in telecommunications, sensing, and medical diagnostics. In this study, a novel method of sizing of step-index fibers is presented on the basis of the analysis of data on light scattering. This approach integrates mathematical modeling of light scattering by step-index fibers with signal processing and correlation algorithms to extract information on the layered structure of the fiber under test. Practical measurements use of a novel optical system for laboratory-level tests. The results show a clear route to improve non-destructive and efficient fiber characterization in online industrial process control.
- 1 January 2020
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 27 (1) , 19-31
NON-INVASIVE MESUREMENTS OF TRANSPARENT FIBRES
- 1 January 2020
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 27 (1) , 19-31
NON-INVASIVE MESUREMENTS OF TRANSPARENT FIBRES
- 21 June 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11056, 136
A hybrid method for velocity field of fluid flow estimation based on optical flow
The paper describes a hybrid method for estimating flow-velocity vector fields from Particle Image Velocimetry (PIV) images that combines a cross-correlation technique with a multiresolution estimation based on optical flow with the aim of obtaining the highest possible spatial resolution. The method offers the possibility to determine one vector per seeding particle. The manuscript examines accuracy of the estimates compared to other known methods using various standard test images. Experimental results are also presented.
- 21 June 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11056, 136
A hybrid method for velocity field of fluid flow estimation based on optical flow
The paper describes a hybrid method for estimating flow-velocity vector fields from Particle Image Velocimetry (PIV) images that combines a cross-correlation technique with a multiresolution estimation based on optical flow with the aim of obtaining the highest possible spatial resolution. The method offers the possibility to determine one vector per seeding particle. The manuscript examines accuracy of the estimates compared to other known methods using various standard test images. Experimental results are also presented.
- 21 June 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11056, 141
Experimental light scattering by optical fibers: system design and testing
This study reports a unique optical system for experimental, laboratory-level testing of light scattering methods for noninvasive characterization of optical fibers. This new modular system comprises of various optical, mechanical, electrical and software components enabling the control, detection, and analysis of the measurement results. Practical measurements are investigated to explore an inverse relationship between scattering data from the vicinity of a rainbow and fiber diameter/refractive index estimates.
- 21 June 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11056, 141
Experimental light scattering by optical fibers: system design and testing
This study reports a unique optical system for experimental, laboratory-level testing of light scattering methods for noninvasive characterization of optical fibers. This new modular system comprises of various optical, mechanical, electrical and software components enabling the control, detection, and analysis of the measurement results. Practical measurements are investigated to explore an inverse relationship between scattering data from the vicinity of a rainbow and fiber diameter/refractive index estimates.
- 24 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10678, 1067815-43
Step-index optical fiber sizing with a rainbow technique
This paper reports an application of a rainbow technique to characterize both the core and cladding diameter of a single, silica-based, step-index optical fiber. Both quantities are inversely calculated using a correlation formula from the farfield scattering pattern where multiple primary rainbows occur. A set of observations of scattering allows one to retrieve the parameters of interest. Numerical studies assume variable core (10–50 μm) as well as cladding diameter (120– 130 μm). A part of analysis shows how the temporal coherence of the incident beam of light affects the solutions.
- 24 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10678, 1067815-43
Step-index optical fiber sizing with a rainbow technique
This paper reports an application of a rainbow technique to characterize both the core and cladding diameter of a single, silica-based, step-index optical fiber. Both quantities are inversely calculated using a correlation formula from the farfield scattering pattern where multiple primary rainbows occur. A set of observations of scattering allows one to retrieve the parameters of interest. Numerical studies assume variable core (10–50 μm) as well as cladding diameter (120– 130 μm). A part of analysis shows how the temporal coherence of the incident beam of light affects the solutions.
- 24 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10679, 56
Fluid flow measurements using optical flow velocity field estimation and LED-based light sheet illumination
The aim of this work is to present a technique for non-intrusive velocity vector measurements of micron-sized tracer particles following a fluid flow. The technique is based on Particle Image Velocimetry (PIV). In contrast to conventional PIV, which analyzes light scattering for incident high-energy laser pulses, the technique uses a light sheet produced by a prototype LED-based illuminator. A sequence of exposures from the flow taken by a high-speed camera is analyzed by means of a multi-scale optical flow-based algorithm developed by the authors. The LED illuminator offers the possibility to deliver high-power light pulses at microsecond levels and high-repetition rates. An integrated optics produce a lightsheet with adjustable thickness and width, enabling the user to measure velocity components either in a plane or in a volume. Compared to pulse lasers used in PIV systems, the illuminator has the advantages of low cost, safe operation, and much simpler construction. For the purposes of experimental verification, velocity vector measurements in a crosssection of a rotary water flow seeded with micron sized tracer particles have been performed. The velocity vectors have been computed using a multi-scale estimation algorithm based on optical flow and four-level pyramidal decomposition of PIV images. In order to validate our optical flow-based approach, the experimental results have been finally analyzed by means of a commercial PIV software that uses image cross-correlation for velocity field estimation.
- 24 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10679, 56
Fluid flow measurements using optical flow velocity field estimation and LED-based light sheet illumination
The aim of this work is to present a technique for non-intrusive velocity vector measurements of micron-sized tracer particles following a fluid flow. The technique is based on Particle Image Velocimetry (PIV). In contrast to conventional PIV, which analyzes light scattering for incident high-energy laser pulses, the technique uses a light sheet produced by a prototype LED-based illuminator. A sequence of exposures from the flow taken by a high-speed camera is analyzed by means of a multi-scale optical flow-based algorithm developed by the authors. The LED illuminator offers the possibility to deliver high-power light pulses at microsecond levels and high-repetition rates. An integrated optics produce a lightsheet with adjustable thickness and width, enabling the user to measure velocity components either in a plane or in a volume. Compared to pulse lasers used in PIV systems, the illuminator has the advantages of low cost, safe operation, and much simpler construction. For the purposes of experimental verification, velocity vector measurements in a crosssection of a rotary water flow seeded with micron sized tracer particles have been performed. The velocity vectors have been computed using a multi-scale estimation algorithm based on optical flow and four-level pyramidal decomposition of PIV images. In order to validate our optical flow-based approach, the experimental results have been finally analyzed by means of a commercial PIV software that uses image cross-correlation for velocity field estimation.
- 24 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10679, 55
Particle image models for optical flow-based velocity field estimation in image velocimetry
This paper examines two models for image representation used for optical flow estimation in Particle Image Velocimetry (PIV). The common approach for flow estimation bases on a cross-correlation between PIV images. An alternative solution bases on an optical flow, which has the advantage of calculating vector fields with much better spatial resolution. The optical flow-based estimation requires calculations of temporal and spatial derivatives of the image intensity, which is usually achieved by using finite differences. Due to rapid intensity changes in the PIV images caused by particles having small diameters, an exact estimation of spatial derivatives using finite differences may lead to numerical errors that render data interpretation limited or even impractical. The present study aims at solving this problem by introducing two algorithms for PIV image processing, which differs in terms of a digital image representation. Both algorithms rely on a PIV image model, wherein the particle image complies with an Airy disc, which is well approximated by using a Gaussian function. Numerical analysis of sample PIV images (uniform and turbulent fields) show that both methods allow for high precision flow-velocity fields estimates in conjunction with the Lucas-Kanade algorithm.
- 24 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10679, 55
Particle image models for optical flow-based velocity field estimation in image velocimetry
This paper examines two models for image representation used for optical flow estimation in Particle Image Velocimetry (PIV). The common approach for flow estimation bases on a cross-correlation between PIV images. An alternative solution bases on an optical flow, which has the advantage of calculating vector fields with much better spatial resolution. The optical flow-based estimation requires calculations of temporal and spatial derivatives of the image intensity, which is usually achieved by using finite differences. Due to rapid intensity changes in the PIV images caused by particles having small diameters, an exact estimation of spatial derivatives using finite differences may lead to numerical errors that render data interpretation limited or even impractical. The present study aims at solving this problem by introducing two algorithms for PIV image processing, which differs in terms of a digital image representation. Both algorithms rely on a PIV image model, wherein the particle image complies with an Airy disc, which is well approximated by using a Gaussian function. Numerical analysis of sample PIV images (uniform and turbulent fields) show that both methods allow for high precision flow-velocity fields estimates in conjunction with the Lucas-Kanade algorithm.
- 26 June 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10329, 103293P-103293P-11
An optical flow-based method for velocity field of fluid flow estimation
- 26 June 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10329, 103293P-103293P-11
An optical flow-based method for velocity field of fluid flow estimation