Jesse Lietzén
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jesse Lietzén has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Mikko Kylliäinen
Faculty of Built Environment, Unit of Civil Engineering, Tampere University, Finland
4 shared publicationsSami Pajunen
Faculty of Built Environment, Unit of Civil Engineering, Tampere University, Finland
2 shared publicationsVille Kovalainen
AINS Group, Department of Acoustical Engineering, Finland
2 shared publications- Hüseyin Emre Ilgın
Tampere University
1 shared publication - Juho Sormunen1 shared publication
- Markku Karjalainen
Tampere University
1 shared publication
Latest Publications
- Open Access
- 6 May 2024
- Published by Elsevier in Engineering Structures
- Vol. 310
Computational prediction of impact sound insulation of a full-scale timber floor applying a FEM simulation procedure
- 6 May 2024
- Published by Elsevier in Engineering Structures
- Vol. 310
Open AccessComputational prediction of impact sound insulation of a full-scale timber floor applying a FEM simulation procedure
- Open Access
An Experimental Comparison of Airborne Sound Insulation between Dovetail Massive Wooden Board and Cross-Laminated Timber Elements
Adhesives and metallic fasteners play a pivotal role in the domain of engineered wood products (EWPs). Nevertheless, owing to their origins in petroleum, adhesives can pose environmental hazards, whereas metal fasteners can complicate end-of-life disposal and reusability. Nonetheless, a resolution emerges in the form of dovetail massive wooden board elements (DMWBEs), characterized by their pure wood composition and absence of adhesive metal connections. The existing literature pertaining to DMWBEs has predominantly focused on inadequate structural analysis and model testing of connection specifics rather than appraising the efficacy of a structural member, such as a floor slab. This article presents a comparative analysis between a DMWBE and a correspondingly sized cross-laminated timber (CLT) panel, focusing on their respective airborne sound insulation capabilities. Experimental samples of model scale with dimensions of 200 mm thickness, 1160 mm width, and 1190 mm length were employed for both CLT and DMWBE. The evaluation of airborne sound insulation performance was conducted in accordance with ISO 10140-2 standards. The findings underscored the superior performance of DMWBE (Rw = 43 dB) in contrast to CLT (Rw = 40 dB) concerning airborne sound insulation efficacy. Additionally, the damping of the panel increased due to the different composition of the DMWBE, as evidenced by a higher measured total loss factor (TLF) compared with CLT.
Open AccessAn Experimental Comparison of Airborne Sound Insulation between Dovetail Massive Wooden Board and Cross-Laminated Timber Elements
Adhesives and metallic fasteners play a pivotal role in the domain of engineered wood products (EWPs). Nevertheless, owing to their origins in petroleum, adhesives can pose environmental hazards, whereas metal fasteners can complicate end-of-life disposal and reusability. Nonetheless, a resolution emerges in the form of dovetail massive wooden board elements (DMWBEs), characterized by their pure wood composition and absence of adhesive metal connections. The existing literature pertaining to DMWBEs has predominantly focused on inadequate structural analysis and model testing of connection specifics rather than appraising the efficacy of a structural member, such as a floor slab. This article presents a comparative analysis between a DMWBE and a correspondingly sized cross-laminated timber (CLT) panel, focusing on their respective airborne sound insulation capabilities. Experimental samples of model scale with dimensions of 200 mm thickness, 1160 mm width, and 1190 mm length were employed for both CLT and DMWBE. The evaluation of airborne sound insulation performance was conducted in accordance with ISO 10140-2 standards. The findings underscored the superior performance of DMWBE (Rw = 43 dB) in contrast to CLT (Rw = 40 dB) concerning airborne sound insulation efficacy. Additionally, the damping of the panel increased due to the different composition of the DMWBE, as evidenced by a higher measured total loss factor (TLF) compared with CLT.
- Open Access
- 2 September 2022
- Published by Elsevier in Engineering Structures
- Vol. 270
Simulation of impact force generated by an ISO tapping machine on a wooden slab using explicit dynamics analysis
- 2 September 2022
- Published by Elsevier in Engineering Structures
- Vol. 270
Open AccessSimulation of impact force generated by an ISO tapping machine on a wooden slab using explicit dynamics analysis
- Open Access
- 25 February 2022
- Published by SAGE Publications in Building Acoustics
- Vol. 29 (2) , 221-237
Vibration level reduction by floor coverings installed on wooden slabs
Effect of floor coverings on impact sound insulation can be described with a vibration level reduction (Δ L a ). In this study, tests with two floor coverings, eight wooden slabs and with a concrete mock-up slab were conducted by applying the method presented by Sommerfeld and the standard ISO 16251-1. The aim was to study the differences affecting the measured Δ L a and the behaviour of the floor coverings installed on different slabs. The results suggest that the Δ L a on concrete slabs do not correspond with the Δ L a on wooden slabs. Thus, the floor coverings should be measured on wooden slabs when they are to be used within the timber construction industry. The results also show that the coverings should be measured on the wooden slabs where the products are expected to be used. In addition, a standardized test method for the wooden slabs corresponding the method of ISO 16251-1 should be developed.
- 25 February 2022
- Published by SAGE Publications in Building Acoustics
- Vol. 29 (2) , 221-237
Open AccessVibration level reduction by floor coverings installed on wooden slabs
Effect of floor coverings on impact sound insulation can be described with a vibration level reduction (Δ L a ). In this study, tests with two floor coverings, eight wooden slabs and with a concrete mock-up slab were conducted by applying the method presented by Sommerfeld and the standard ISO 16251-1. The aim was to study the differences affecting the measured Δ L a and the behaviour of the floor coverings installed on different slabs. The results suggest that the Δ L a on concrete slabs do not correspond with the Δ L a on wooden slabs. Thus, the floor coverings should be measured on wooden slabs when they are to be used within the timber construction industry. The results also show that the coverings should be measured on the wooden slabs where the products are expected to be used. In addition, a standardized test method for the wooden slabs corresponding the method of ISO 16251-1 should be developed.
- 15 September 2015
- Published by European Acoustics Association in Acta Acustica united with Acustica
- Vol. 101 (5) , 975-985
Correlation Between Single-Number-Quantities of Impact Sound Insulation and Various Noise Ratings of Walking on Concrete Floors
- 15 September 2015
- Published by European Acoustics Association in Acta Acustica united with Acustica
- Vol. 101 (5) , 975-985
Correlation Between Single-Number-Quantities of Impact Sound Insulation and Various Noise Ratings of Walking on Concrete Floors