Yulong Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yulong Yang has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Kejia Zhang
College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China
5 shared publications Zheyu Huang
College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, People’s Republic of China
4 shared publicationsTuqiao Zhang
Zhejiang University
3 shared publicationsJie Chen
College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, People’s Republic of China
2 shared publications- Jintao Wang
College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, Zhejiang 310058, P. R. China
2 shared publications Jun Qian
Jinhua Water Supply Co., Ltd, Jinhua, People’s Republic of China
2 shared publications
Latest Publications
- 11 March 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (10) , 106001
Leakage information identification for water supply pipelines based on multimodal two-stream feature-fusion with two-stage convolutional neural network
Traditional water pipeline leakage identification has several limitations, such as incomplete signal feature extraction and the underutilization of physical information. To overcome these limitations, this study proposes multimodal two-stream feature-fusion with two-stage convolutional neural network (MTFT-CNN). The analysis reveals that local dynamic features in time–frequency spectrograms complement global statistical features in the time and frequency domains. Accordingly, a multimodal two-stream architecture is developed to extract global statistical features concurrently from vibration-acoustic signals and local dynamic features from spectrograms. The cross-modal bidirectional attention module enables the adaptive fusion of these heterogeneous representations. The two-stage classification strategy enhances recognition efficiency: in the first stage, a hard-gating mechanism filters out non-leakage samples, while in the second stage, a multi-task learning framework, guided by the physical correlation between pressure and aperture, achieves the fine-grained identification of operating conditions. The experimental results show accuracies of 99.15%, 97.75% and 96.63% for leakage state, pressure and aperture recognition, respectively, with an overall accuracy of 98.37%. Ablation and comparative analyses confirm that MTFT-CNN significantly improves the comprehensiveness, precision and engineering applicability of leakage information identification, offering an effective solution for high-precision and high-efficiency leakage information identification in water supply pipelines.
- 11 March 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (10) , 106001
Leakage information identification for water supply pipelines based on multimodal two-stream feature-fusion with two-stage convolutional neural network
Traditional water pipeline leakage identification has several limitations, such as incomplete signal feature extraction and the underutilization of physical information. To overcome these limitations, this study proposes multimodal two-stream feature-fusion with two-stage convolutional neural network (MTFT-CNN). The analysis reveals that local dynamic features in time–frequency spectrograms complement global statistical features in the time and frequency domains. Accordingly, a multimodal two-stream architecture is developed to extract global statistical features concurrently from vibration-acoustic signals and local dynamic features from spectrograms. The cross-modal bidirectional attention module enables the adaptive fusion of these heterogeneous representations. The two-stage classification strategy enhances recognition efficiency: in the first stage, a hard-gating mechanism filters out non-leakage samples, while in the second stage, a multi-task learning framework, guided by the physical correlation between pressure and aperture, achieves the fine-grained identification of operating conditions. The experimental results show accuracies of 99.15%, 97.75% and 96.63% for leakage state, pressure and aperture recognition, respectively, with an overall accuracy of 98.37%. Ablation and comparative analyses confirm that MTFT-CNN significantly improves the comprehensiveness, precision and engineering applicability of leakage information identification, offering an effective solution for high-precision and high-efficiency leakage information identification in water supply pipelines.
- 16 February 2026
- Published by Elsevier in Structures
- Vol. 86
Identification of vibration sources based on the fusion characteristics of vibration signals
- 16 February 2026
- Published by Elsevier in Structures
- Vol. 86
Identification of vibration sources based on the fusion characteristics of vibration signals
- 5 February 2026
- Published by Elsevier in Measurement
- Vol. 269
Comprehensive explainable model using low-frequency vibration characteristics for leakage detection in water pipelines
- 5 February 2026
- Published by Elsevier in Measurement
- Vol. 269
Comprehensive explainable model using low-frequency vibration characteristics for leakage detection in water pipelines
- 9 March 2025
- Published by Elsevier in Structures
- Vol. 74
Vibration source identification method based on multisensor vibration signal fusion analysis
- 9 March 2025
- Published by Elsevier in Structures
- Vol. 74
Vibration source identification method based on multisensor vibration signal fusion analysis
- 15 May 2024
- Published by World Scientific Pub Co Pte Ltd in International Journal of Structural Stability and Dynamics
- Vol. 25 (09)
Structural Vibration Identification in Ancient Buildings Based on Multi-Feature and Multi-Sensor
Ancient buildings have strict standards for vibration control. Effectively identifying vibration types and controlling construction vibrations during construction activities is advantageous to the structural safety of ancient buildings. This study is based on an analysis of vibration data from the top, foundation, and bedrock of the White Pagoda in Hangzhou, Zhejiang province, which is an ancient building. Considering the surrounding construction and wind environment, this study focuses on analyzing the data features of tower vibrations under three types of structural vibration. We propose a support vector machine (SVM) vibration identification method that incorporates multi-feature parameters and multi-sensor signal correlation. This method effectively identifies the source of structural vibration by distinguishing between typical wind-induced vibrations, typical construction vibrations, and typical mixed vibrations. The application of this method could guide construction activities and mitigate the safety impacts of construction and mixed vibrations on historical building structures.
- 15 May 2024
- Published by World Scientific Pub Co Pte Ltd in International Journal of Structural Stability and Dynamics
- Vol. 25 (09)
Structural Vibration Identification in Ancient Buildings Based on Multi-Feature and Multi-Sensor
Ancient buildings have strict standards for vibration control. Effectively identifying vibration types and controlling construction vibrations during construction activities is advantageous to the structural safety of ancient buildings. This study is based on an analysis of vibration data from the top, foundation, and bedrock of the White Pagoda in Hangzhou, Zhejiang province, which is an ancient building. Considering the surrounding construction and wind environment, this study focuses on analyzing the data features of tower vibrations under three types of structural vibration. We propose a support vector machine (SVM) vibration identification method that incorporates multi-feature parameters and multi-sensor signal correlation. This method effectively identifies the source of structural vibration by distinguishing between typical wind-induced vibrations, typical construction vibrations, and typical mixed vibrations. The application of this method could guide construction activities and mitigate the safety impacts of construction and mixed vibrations on historical building structures.
- Open Access
Degradation of Tryptophan by UV Irradiation: Influencing Parameters and Mechanisms
The chlorination of dissolved amino acids can generate disinfection by-products (DBPs). To prevent the formation of DBPs, we examined the UV-induced degradation of tryptophan (Trp). In order to further understand the impact of UV disinfection on Trp, the effects of initial concentrations of Trp, pH, temperature, concentrations of NO3−, HCO3− and Cl− on Trp removal were investigated, and a degradation mechanism was also proposed. The results demonstrated that degradation fitted a pseudo first-order reaction kinetic model. The degradation of Trp was mainly caused by direct UV degradation. The apparent rate constant kobs decreased with the increase in initial Trp concentration and increased with increases in pH and temperature. The thermal degradation activation energy was 19.65 kJ/mol. Anions in water also had a significant influence on the degradation of Trp. HCO3− and NO3− contributed to the kobs of Trp, but Cl− inhibited the degradation rate. By electron paramagnetic resonance (EPR) spectroscopy, ·OH was proven to be formed during the degradation of Trp by UV. Based on the intermediate products of C11H15NO3, C10H15N and C9H13N detected by LC-MS-MS, the degradation pathway of Trp was speculated.
Open AccessDegradation of Tryptophan by UV Irradiation: Influencing Parameters and Mechanisms
The chlorination of dissolved amino acids can generate disinfection by-products (DBPs). To prevent the formation of DBPs, we examined the UV-induced degradation of tryptophan (Trp). In order to further understand the impact of UV disinfection on Trp, the effects of initial concentrations of Trp, pH, temperature, concentrations of NO3−, HCO3− and Cl− on Trp removal were investigated, and a degradation mechanism was also proposed. The results demonstrated that degradation fitted a pseudo first-order reaction kinetic model. The degradation of Trp was mainly caused by direct UV degradation. The apparent rate constant kobs decreased with the increase in initial Trp concentration and increased with increases in pH and temperature. The thermal degradation activation energy was 19.65 kJ/mol. Anions in water also had a significant influence on the degradation of Trp. HCO3− and NO3− contributed to the kobs of Trp, but Cl− inhibited the degradation rate. By electron paramagnetic resonance (EPR) spectroscopy, ·OH was proven to be formed during the degradation of Trp by UV. Based on the intermediate products of C11H15NO3, C10H15N and C9H13N detected by LC-MS-MS, the degradation pathway of Trp was speculated.
- Open Access
- 1 June 2020
- Published by Elsevier in Desalination and Water Treatment
- Vol. 189, 217-226
Effect and applicability of different phosphates on inhibiting iron release in water distribution system
- 1 June 2020
- Published by Elsevier in Desalination and Water Treatment
- Vol. 189, 217-226
Open AccessEffect and applicability of different phosphates on inhibiting iron release in water distribution system
- Open Access
Occurrence of Free Amino Acids in the Source Waters of Zhejiang Province, China, and Their Removal and Transformation in Drinking Water Systems
Free amino acids (FAAs) are key components of the global nitrogen cycle and important disinfection byproduct (DBP) precursors. The knowledge gap of FAA occurrence in source and engineered water is discussed in this paper. Solid phase extraction and post column derivatization was combined with gas chromatography–mass spectrometry to simultaneously detect μg/L concentrations of FAAs. This method efficiently detects alanine (Ala), threonine (Thr), serine (Ser), valine (Val), leucine (Leu), isoleucine (Ile), proline (Pro), aspartic (Asp), phenylalanine (Phe), and glutamic acid (Glu) with good linearity, accuracy, and precision. An investigation of FAAs in surface waters in Zhejiang Province found concentrations of 1.48–14.73 μg/L Ala, 0.20–2.39 μg/L Thr, 0.41–7.84 μg/L Val, 0.21–6.86 μg/L Ser, 0.11–4.16 μg/L Leu, 0.57–1.54 μg/L Ile, 0.24–8.06 μg/L Pro, 0.42–4.73 μg/L Asp, 0.30–3.01 μg/L Phe, and 0.12–3.83 μg/L Glu. Phe and tyrosine (Tyr) exhibited higher trichloromethane (TCM) formation (1029–1148 μg/mmolAA) than dichloroacetonitrile (DCAN) formation (333–347 μg/mmolAA). Asp and Glu demonstrated the opposite trend: higher DCAN (570–1106 μg/mmolAA) formation than TCM (137–506 μg/mmolAA).
Open AccessOccurrence of Free Amino Acids in the Source Waters of Zhejiang Province, China, and Their Removal and Transformation in Drinking Water Systems
Free amino acids (FAAs) are key components of the global nitrogen cycle and important disinfection byproduct (DBP) precursors. The knowledge gap of FAA occurrence in source and engineered water is discussed in this paper. Solid phase extraction and post column derivatization was combined with gas chromatography–mass spectrometry to simultaneously detect μg/L concentrations of FAAs. This method efficiently detects alanine (Ala), threonine (Thr), serine (Ser), valine (Val), leucine (Leu), isoleucine (Ile), proline (Pro), aspartic (Asp), phenylalanine (Phe), and glutamic acid (Glu) with good linearity, accuracy, and precision. An investigation of FAAs in surface waters in Zhejiang Province found concentrations of 1.48–14.73 μg/L Ala, 0.20–2.39 μg/L Thr, 0.41–7.84 μg/L Val, 0.21–6.86 μg/L Ser, 0.11–4.16 μg/L Leu, 0.57–1.54 μg/L Ile, 0.24–8.06 μg/L Pro, 0.42–4.73 μg/L Asp, 0.30–3.01 μg/L Phe, and 0.12–3.83 μg/L Glu. Phe and tyrosine (Tyr) exhibited higher trichloromethane (TCM) formation (1029–1148 μg/mmolAA) than dichloroacetonitrile (DCAN) formation (333–347 μg/mmolAA). Asp and Glu demonstrated the opposite trend: higher DCAN (570–1106 μg/mmolAA) formation than TCM (137–506 μg/mmolAA).
- 10 April 2019
- Published by Springer Nature in Applied Microbiology and Biotechnology
- Vol. 103 (11) , 4269-4277
A novel method: using an adenosine triphosphate (ATP) luminescence–based assay to rapidly assess the biological stability of drinking water
The rapid and credible evaluations of the microbial stability of a drinking water distribution system (DWDS) are of great significance for ensuring the safety of drinking water and predicting microbial pollution. Conventional biostability assessment methods mainly focus on bacterial regrowth or evaluation of the level of nutrients that support bacterial regrowth. However, such methods are time-consuming and have many limitations. An adenosine triphosphate (ATP) assay can rapidly measure all active microorganisms and is known to be a useful method to assess the microbial activity of drinking water. The measurement of ATP has been used for more than a decade in the field of drinking water research. This article reviews the application of an ATP luminescence-based method to assess the biostability of drinking water and discusses the feasibility of ATP measurement as a parameter for quickly evaluating this criterion. ATP measurement will help researchers and water managers better monitor the biological stability of drinking water from the source to the consumer’s tap. This review covers the: (1) principle and application of the ATP measurement in drinking water quality assessment; (2) comparison of the merits and demerits of several methods for evaluating the biostability of drinking water; (3) discussions on using ATP measurement in evaluating biostability; and (4) improvements in the use of ATP measurement in evaluating biostability. At the end of this review, recommendations were given for better application of the ATP measurement as a parameter for monitoring the microbial quality of drinking water.
- 10 April 2019
- Published by Springer Nature in Applied Microbiology and Biotechnology
- Vol. 103 (11) , 4269-4277
A novel method: using an adenosine triphosphate (ATP) luminescence–based assay to rapidly assess the biological stability of drinking water
The rapid and credible evaluations of the microbial stability of a drinking water distribution system (DWDS) are of great significance for ensuring the safety of drinking water and predicting microbial pollution. Conventional biostability assessment methods mainly focus on bacterial regrowth or evaluation of the level of nutrients that support bacterial regrowth. However, such methods are time-consuming and have many limitations. An adenosine triphosphate (ATP) assay can rapidly measure all active microorganisms and is known to be a useful method to assess the microbial activity of drinking water. The measurement of ATP has been used for more than a decade in the field of drinking water research. This article reviews the application of an ATP luminescence-based method to assess the biostability of drinking water and discusses the feasibility of ATP measurement as a parameter for quickly evaluating this criterion. ATP measurement will help researchers and water managers better monitor the biological stability of drinking water from the source to the consumer’s tap. This review covers the: (1) principle and application of the ATP measurement in drinking water quality assessment; (2) comparison of the merits and demerits of several methods for evaluating the biostability of drinking water; (3) discussions on using ATP measurement in evaluating biostability; and (4) improvements in the use of ATP measurement in evaluating biostability. At the end of this review, recommendations were given for better application of the ATP measurement as a parameter for monitoring the microbial quality of drinking water.