VHVincent J. Hetherington

Vincent J. Hetherington

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vincent J. Hetherington has a total of 114 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Survey research in podiatric medicine: An analysis of the reporting of response rates and non-response bias

    by Jessica L. Mulvany, Vincent J. Hetherington, Jonathan B. VanGeest


  • Effect of repeated cycles of steam sterilization on the integrity of cannulated surgical screws

    by Kelly Capuder, Christopher Gill, Jawdat Hafez, Jill Kawalec, Vincent Hetherington


  • Open Access

    A Novel Thermochromic Liquid Crystal Fabric Design for the Early Detection of High-Risk Foot Complications

    by Jonathan D. LeSar, Nilin M. Rao, Nicholas M. Williams, Jeffrey P. Pantano, Melissa L. Ricci, Lawrence S. Osher, Vincent J. Hetherington, Jill S. Kawalec

    Background: We developed a prototype of a novel thermochromic liquid crystal (TLC)–coated fabric with an extended temperature range and enhanced sensitivity. By incorporating color and pattern recognition into the fabric, rapid determination of the underlying pedal temperature is facilitated. The purpose of this study was to evaluate the accuracy of the TLC fabric as a potential diagnostic aid for identifying complications in the high-risk foot. Methods: The hands of 100 individuals were used to compare the mean maximum temperatures indicated by the fabric versus standard thermal camera images. Findings were statistically analyzed using a paired t test, with significance defined as P < .05. Results: Except for the tip of the thumb and regions in the palm, there were no statistically significant differences between mean maximum temperatures measured with the thermal camera and those detected with the TLC fabric. Minor differences were relatively consistent in all nine regions of the hand and were not considered to be clinically significant. Conclusions: Using direct visual analysis, we demonstrated that a novel TLC fabric could accurately map temperatures in the palmar surface of the hand. The findings support the continued development of a temperature-sensitive sock that can be used in the home to monitor for temperature changes that may indicate the onset of complications in the high-risk foot.


  • Open Access

    Foot Temperature Trends in Normal, Diabetic, and Neuropathic Foot Populations

    by Azza Alalwee, Jonathan D. LeSar, Mina Ghassemi, Eugene Cheng, Steven Stuto, Lawrence Osher, Scott Bastian, Vincent J. Hetherington, Jill Kawalec

    INTRODUCTION AND OBJECTIVES: Patients with underlying peripheral neuropathy are subject to changes in foot temperature. (1,2) Of the many forms of neuropathy that affect the lower extremity, the most notable are those types associated with diabetes. The aim of this study was to look for differences in temperatures between uncomplicated diabetic, diabetic neuropathic, and non-diabetic neuropathic feet. METHODS: The feet of 75 subjects were divided into 3 groups: 1) normal (n=50 feet), 2) diabetic (n=50 feet), and 3) neuropathic (n=49 feet). The neuropathic group was further subdivided into diabetic neuropathies (n=20 feet) and non-diabetic neuropathies (n=29 feet). To properly assign subjects to groups, all participants underwent vibratory threshold testing with a biothesiometer. In addition, all diabetic subjects had added glycosylated hemoglobin (hemoglobin A1C) studies performed. Temperature measurements were recorded at nine distinct foot locations (six plantar and three dorsal). Data was statistically analyzed using the Kruskal-Wallis test. RESULTS: For five of the plantar pedal sites tested, temperatures in the diabetic foot were significantly greater than those for the normal controls (p<0.05). At most sites, temperatures in the diabetic foot population tended to be higher than those in both diabetic and non-diabetic neuropathic feet, with the differences between the diabetic foot and non-diabetic neuropathic foot being statistically significant at one dorsal and five plantar sites. Patients in the non-diabetic neuropathic group were not stratified according to their specific neuropathic types. CONCLUSIONS: Diabetic feet, with and without neuropathy, tend to be warmer than the feet of patients with other non-diabetic neuropathies. The finding of no statistical difference between non-neuropathic diabetic and neuropathic diabetic feet is unexpected in that a number of these patients were projected to have an autonomic system component. These null findings suggest the need to further investigate neuropathy solely determined by sensory testing versus tests for autonomic system involvement.


  • Open Access

    Assessment Plan for Student Academic Achievement

    by Vincent J. Hetherington

    The general public has become increasingly concerned about the accomplishments of education. Accrediting bodies are holding institutions of higher education accountable for educational services and are demanding a variety of assessment activities. This article presents the plan for assessment of student achievement at the Kent State University College of Podiatric Medicine. (J Am Podiatr Med Assoc 102(6): 529–534, 2012)

  • Prediction of Plantar Shear Stress Distribution by Artificial Intelligence Methods

    by Metin Yavuz, Hasan Ocak, Vincent J. Hetherington, Brian L. Davis

    Shear forces under the human foot are thought to be responsible for various foot pathologies such as diabetic plantar ulcers and athletic blisters. Frictional shear forces might also play a role in the metatarsalgia observed among hallux valgus (HaV) and rheumatoid arthritis (RA) patients. Due to the absence of commercial devices capable of measuring shear stress distribution, a number of linear models were developed. All of these have met with limited success. This study used nonlinear methods, specifically neural network and fuzzy logic schemes, to predict the distribution of plantar shear forces based on vertical loading parameters. In total, 73 subjects were recruited; 17 had diabetic neuropathy, 14 had HaV, 9 had RA, 11 had frequent foot blisters, and 22 were healthy. A feed-forward neural network (NN) and adaptive neurofuzzy inference system (NFIS) were built. These systems were then applied to a custom-built platform, which collected plantar pressure and shear stress data as subjects walked over the device. The inputs to both models were peak pressure, peak pressure-time integral, and time to peak pressure, and the output was peak resultant shear. Root-mean-square error (RMSE) values were calculated to test the models’ accuracy. RMSE/actual shear ratio varied between 0.27 and 0.40 for NN predictions. Similarly, NFIS estimations resulted in a 0.28–0.37 ratio for local peak values in all subject groups. On the other hand, error percentages for global peak shear values were found to be in the range 11.4–44.1. These results indicate that there is no direct relationship between pressure and shear magnitudes. Future research should aim to decrease error levels by introducing shear stress dependent variables into the models.


  • Forefoot plantar shear stress distribution in hallux valgus patients

    by Metin Yavuz, Vincent J. Hetherington, Georgeanne Botek, Gordon B. Hirschman, Lynn Bardsley, Brian L. Davis


  • Evaluation of surgical experience and the use of an osteotomy guide on the apical angle of an Austin osteotomy

    by V.J. Hetherington, J.S. Kawalec-Carroll, J. Melillo-Kroleski, T. Jones, M. Melillo, N. McFarland, M. Blazer, J.A. Favazzo


  • Open Access

    Immunogenicity of unprocessed and photooxidized bovine and human osteochondral grafts in collagen-sensitive mice

    by Jill S Kawalec-Carroll, Vincent J Hetherington, Douglas S Dockery, Carey Shive, Oleg S Targoni, Paul V Lehmann, Daniel Nadler, Dustin Prins

    Background: Autologous and allogeneic osteochondral grafts have been used to repair damaged or diseased cartilage. There are drawbacks to both of these methods, however. Another possible source for osteochondral grafting is photooxidized xenograft scaffolds. The purpose of this study was to evaluate the adaptive immune response to unprocessed and photooxidized xenogeneic osteochondral grafts in a collagen-sensitive mouse model. Methods: Unprocessed and photooxidized bovine and human osteochondral grafts were used. The grafts were implanted subcutaneously in collagen-sensitive DBA/1LacJ mice for four or twelve weeks. ELISPOT assays were conducted with spleen cells to evaluate the number of collagen-specific T cells that produce IL-2, IL-4, IL-5 or IFN-γ. Serum was collected and ELISA assays were performed to determine the titers of collagen-specific and total IgG, IgG1, IgG2a, or IgM antibodies. Histology was conducted on the retrieved osteochondral grafts. Results: Results indicated that, with respect to adaptive T cell immunity, the photooxidized bovine grafts, unprocessed human grafts and photooxidized human grafts did not induce a significant response to collagen. The unprocessed bovine grafts, however, were slightly more immunogenic, inducing a weak immune response. With respect to antibody production, the bovine grafts were less immunogenic than the human grafts. Bovine collagen-specific IgG antibodies were not induced by these grafts, but production of IgM after twelve weeks was observed with both the unprocessed and photooxidized bovine grafts. In contrast, photooxidized human osteochondral grafts induced IgG1 and IgG2a antibodies, while the unprocessed human grafts did not. Pre-existing human collagen-specific IgM antibodies were present in all mice, including sham-operated negative controls that did not receive an implant. Histological analysis revealed some degree of fibrous encapsulation and inflammatory infiltrations in both bovine and human implants, whether unprocessed or photooxidized. Conclusion: Both bovine and human cartilage grafts showed weak, but clear immunogenicity in the DBA/1LacJ mice, indicating that immunogenic collagen was still contained in the grafts, even after cleaning and photooxidation. The process of photooxidation is still important in osteochondral grafting, since it stabilizes the surface of the cartilage by cross-linking the collagen fibers, and allows for immediate load bearing and joint resurfacing.