Ugur Pasaogullari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ugur Pasaogullari has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
- Aman Uddin
Bangladesh University of Engineering and Technology (BUET)
23 shared publications Trent Molter
23 shared publicationsLeonard J. Bonville
University of Connecticut
18 shared publicationsXiaofeng Wang
15 shared publicationsJaehyung Park
University of Connecticut
13 shared publicationsJing Qi
12 shared publications
Latest Publications
- 3 July 2019
- Published by The Electrochemical Society in ECS Transactions
- Vol. 92 (8) , 411-418
Contamination of Pt Catalyst with Carbon Monoxide during Hydrogen Evolution
Effect of carbon monoxide (CO) on the hydrogen evolution reaction (HER) on Pt electrode is investigated. Electrochemical hydrogen pump (EHP) cells are exposed to CO in hydrogen (H2) on the HER electrode with pure H2 maintained in the hydrogen oxidation reaction (HOR) electrode. Cyclic voltammetry is utilized to measure carbon monoxide coverage on the catalyst surface. Chemical adsorption and desorption are the dominant mechanisms to determine CO coverage on the HER electrode; hydrogen evaluation reaction has minimal effect on the CO coverage, and CO coverage has minimal impact on the HER rate unlike the HOR.
- 3 July 2019
- Published by The Electrochemical Society in ECS Transactions
- Vol. 92 (8) , 411-418
Contamination of Pt Catalyst with Carbon Monoxide during Hydrogen Evolution
Effect of carbon monoxide (CO) on the hydrogen evolution reaction (HER) on Pt electrode is investigated. Electrochemical hydrogen pump (EHP) cells are exposed to CO in hydrogen (H2) on the HER electrode with pure H2 maintained in the hydrogen oxidation reaction (HOR) electrode. Cyclic voltammetry is utilized to measure carbon monoxide coverage on the catalyst surface. Chemical adsorption and desorption are the dominant mechanisms to determine CO coverage on the HER electrode; hydrogen evaluation reaction has minimal effect on the CO coverage, and CO coverage has minimal impact on the HER rate unlike the HOR.
- 23 July 2018
- Published by The Electrochemical Society in ECS Transactions
- Vol. 86 (13) , 407-419
Polymer Electrolyte Fuel Cell Degradation through Foreign Cation Contamination, Proton Depletion and Carbon Corrosion
The influence of foreign cationic contamination on the thinning of the cathode catalyst layer during non-accelerated testing is explored. Long duration (400 hours) testing was conducted using commercial catalyst coated membranes (CCMs) which showed significant catalyst layer thinning and sharp decrease in performance in a calcium cation contaminated cell. This thinning of the cathode catalyst layer was not observed in a non-contaminated baseline cell. A numerical model was employed to show the foreign cation redistribution during testing, which shows proton depletion in the cathode catalyst layer when the CCM is contaminated with foreign cations. We hypothesize that this lack of protons leads to accelerated carbon corrosion in the cathode to supply protons to oxygen reduction where foreign cations block transport of protons. The transient model is found to under predict the time for cation redistribution, which may be due to lack of accurate of physical and transport parameters.
- 23 July 2018
- Published by The Electrochemical Society in ECS Transactions
- Vol. 86 (13) , 407-419
Polymer Electrolyte Fuel Cell Degradation through Foreign Cation Contamination, Proton Depletion and Carbon Corrosion
The influence of foreign cationic contamination on the thinning of the cathode catalyst layer during non-accelerated testing is explored. Long duration (400 hours) testing was conducted using commercial catalyst coated membranes (CCMs) which showed significant catalyst layer thinning and sharp decrease in performance in a calcium cation contaminated cell. This thinning of the cathode catalyst layer was not observed in a non-contaminated baseline cell. A numerical model was employed to show the foreign cation redistribution during testing, which shows proton depletion in the cathode catalyst layer when the CCM is contaminated with foreign cations. We hypothesize that this lack of protons leads to accelerated carbon corrosion in the cathode to supply protons to oxygen reduction where foreign cations block transport of protons. The transient model is found to under predict the time for cation redistribution, which may be due to lack of accurate of physical and transport parameters.
- Open Access
- 9 February 2018
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 165 (6) , F3015-F3023
Thinning of Cathode Catalyst Layer in Polymer Electrolyte Fuel Cells Due to Foreign Cation Contamination
Four hundred hour fuel cell tests were performed on commercial, as-received and Ca2+ contaminated catalyst coated membranes (CCMs) to evaluate the effects of long term exposure of foreign cations on fuel cell performance and degradation. Following testing, significant thinning of the cathode catalyst layer was observed across the entire active area in the contaminated cell, while only localized thinning was observed in the as-received baseline CCM. Analysis of the elemental maps and line intensity profiles of platinum (Pt) obtained from energy dispersive X-ray spectrum (EDX) shows minimal change in total platinum content across the thickness of the catalyst layer, and hence loss of carbon is suspected to be the cause of the thinning. A numerical model is employed to show the foreign cation redistribution during testing, which shows proton depletion in the cathode catalyst layer when the CCM is contaminated with foreign cations. We hypothesize that this lack of protons leads to accelerated carbon corrosion in the cathode to supply protons to oxygen reduction where foreign cations block transport of protons. A carbon corrosion scheme is presented which shows that under the operating potentials of the cell, carbon oxidation can occur, leading to the observed thinning.
- 9 February 2018
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 165 (6) , F3015-F3023
Open AccessThinning of Cathode Catalyst Layer in Polymer Electrolyte Fuel Cells Due to Foreign Cation Contamination
Four hundred hour fuel cell tests were performed on commercial, as-received and Ca2+ contaminated catalyst coated membranes (CCMs) to evaluate the effects of long term exposure of foreign cations on fuel cell performance and degradation. Following testing, significant thinning of the cathode catalyst layer was observed across the entire active area in the contaminated cell, while only localized thinning was observed in the as-received baseline CCM. Analysis of the elemental maps and line intensity profiles of platinum (Pt) obtained from energy dispersive X-ray spectrum (EDX) shows minimal change in total platinum content across the thickness of the catalyst layer, and hence loss of carbon is suspected to be the cause of the thinning. A numerical model is employed to show the foreign cation redistribution during testing, which shows proton depletion in the cathode catalyst layer when the CCM is contaminated with foreign cations. We hypothesize that this lack of protons leads to accelerated carbon corrosion in the cathode to supply protons to oxygen reduction where foreign cations block transport of protons. A carbon corrosion scheme is presented which shows that under the operating potentials of the cell, carbon oxidation can occur, leading to the observed thinning.
- 1 January 2018
- Published by Elsevier in Applied Surface Science
- Vol. 427, 273-280
Wettability measurements of irregular shapes with Wilhelmy plate method
- 1 January 2018
- Published by Elsevier in Applied Surface Science
- Vol. 427, 273-280
Wettability measurements of irregular shapes with Wilhelmy plate method
- 1 January 2018
- Published by Elsevier in Electrochimica Acta
- Vol. 259, 510-516
Evaluation of cathode contamination with Ca2+ in proton exchange membrane fuel cells
- 1 January 2018
- Published by Elsevier in Electrochimica Acta
- Vol. 259, 510-516
Evaluation of cathode contamination with Ca2+ in proton exchange membrane fuel cells
- 3 October 2017
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (13) , F1342-F1347
Electrochemical Validation of In-Cell Chromium Getters to Mitigate Chromium Poisoning in SOFC Stack
A porous, electrically conductive getter layer, consisting of mixtures of metal oxide getter and an electrically conducting perovskite phase, has been fabricated for incorporation in between the cell interconnect and the cathode to capture gaseous chromium species. Getter layer has been electrochemically tested in half-cell configuration in the presence of chromium vapor (Cr2O3 /Air-3% H2O) at 850°C for 100 hours. The electrochemical performance remains stable as evidenced by stable current density (I-t) at 0.5 V applied bias and EIS data obtained during the test. Tested cells were analyzed for the composition of reaction products and changes in the morphology. The gaseous chromium predominantly concentrated at the impinging getter surface, and the bulk electrode and electrode-electrolyte interface remained free of chromium.
- 3 October 2017
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (13) , F1342-F1347
Electrochemical Validation of In-Cell Chromium Getters to Mitigate Chromium Poisoning in SOFC Stack
A porous, electrically conductive getter layer, consisting of mixtures of metal oxide getter and an electrically conducting perovskite phase, has been fabricated for incorporation in between the cell interconnect and the cathode to capture gaseous chromium species. Getter layer has been electrochemically tested in half-cell configuration in the presence of chromium vapor (Cr2O3 /Air-3% H2O) at 850°C for 100 hours. The electrochemical performance remains stable as evidenced by stable current density (I-t) at 0.5 V applied bias and EIS data obtained during the test. Tested cells were analyzed for the composition of reaction products and changes in the morphology. The gaseous chromium predominantly concentrated at the impinging getter surface, and the bulk electrode and electrode-electrolyte interface remained free of chromium.
- 1 October 2017
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 42 (41) , 26068-26083
Experimental observation of the effect of cleansing agents on the performance of polymer electrolyte fuel cells
- 1 October 2017
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 42 (41) , 26068-26083
Experimental observation of the effect of cleansing agents on the performance of polymer electrolyte fuel cells
- 24 August 2017
- Published by The Electrochemical Society in ECS Transactions
- Vol. 80 (8) , 497-507
The Influence of CO on Hydrogen Evolution
Electrochemical impedance spectroscopy (EIS) measurements are performed on an electrochemical sensor exposed to carbon monoxide in a hydrogen environment. Equivalent circuits are fit to data recorded prior to and after CO contamination in order to characterize the changes occurring in the sensor following poisoning of the electrodes, and find that both short time scale (kinetics) and long time scale (diffusion like) phenomena are affected by the presence of CO on the catalyst surface. Further work to more completely describe changes to the sensor is ongoing.
- 24 August 2017
- Published by The Electrochemical Society in ECS Transactions
- Vol. 80 (8) , 497-507
The Influence of CO on Hydrogen Evolution
Electrochemical impedance spectroscopy (EIS) measurements are performed on an electrochemical sensor exposed to carbon monoxide in a hydrogen environment. Equivalent circuits are fit to data recorded prior to and after CO contamination in order to characterize the changes occurring in the sensor following poisoning of the electrodes, and find that both short time scale (kinetics) and long time scale (diffusion like) phenomena are affected by the presence of CO on the catalyst surface. Further work to more completely describe changes to the sensor is ongoing.
- 5 August 2017
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (12) , F1100-F1109
Linking Foreign Cationic Contamination of PEM Fuel Cells to the Local Water Distribution
Cationic contamination of polymer electrolyte fuel cells is known to cause performance degradation, particularly due to displacement of protons by foreign cations in the ionomer. Recent findings however, show that mass transport is a critical mechanism in the contamination process. X-ray computed tomography is used to examine the salt precipitation within the cathode diffusion media following in situ cation contamination experiments. Statistical analysis of the tomographic data is performed to examine the salt distribution inside a contaminated dual layer carbon paper substrate (GDL)-MPL. Results confirm the presence of salts on the surface, which is visually observable, but also show subsurface salts that are present up to the GDL-MPL interface. This new finding shows that cationic salts can precipitate in the macroporous carbon paper substrate, and the hydrophobic microporous MPL acts as a barrier to restrict cationic transport from reaching the fuel cell catalyst layer and membrane.
- 5 August 2017
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (12) , F1100-F1109
Linking Foreign Cationic Contamination of PEM Fuel Cells to the Local Water Distribution
Cationic contamination of polymer electrolyte fuel cells is known to cause performance degradation, particularly due to displacement of protons by foreign cations in the ionomer. Recent findings however, show that mass transport is a critical mechanism in the contamination process. X-ray computed tomography is used to examine the salt precipitation within the cathode diffusion media following in situ cation contamination experiments. Statistical analysis of the tomographic data is performed to examine the salt distribution inside a contaminated dual layer carbon paper substrate (GDL)-MPL. Results confirm the presence of salts on the surface, which is visually observable, but also show subsurface salts that are present up to the GDL-MPL interface. This new finding shows that cationic salts can precipitate in the macroporous carbon paper substrate, and the hydrophobic microporous MPL acts as a barrier to restrict cationic transport from reaching the fuel cell catalyst layer and membrane.