Hector Mario Gutiérrez-Zapata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hector Mario Gutiérrez-Zapata has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Janeth Sanabria
Environmental Microbiology and Biotechnology Laboratory, Engineering School of Environmental & Natural Resources, Engineering Faculty, Universidad del Valle - Sede Meléndez, A.A. 25360, Santiago de Cali, Colombia
4 shared publications- John Jairo Alvear‐Daza
Laboratory of Advanced Oxidation Processes and Photocatalysis (LAPh), Centro de Investigación y Desarrollo en Ciencias Aplicadas “Dr. J.J. Ronco” (CINDECA), Departamento de Química, Facultad de Ciencias Exactas, UNLP-CCT La Plata, CONICET, 47 No. 257, 1900 La Plata, Buenos Aires, Argentina
3 shared publications - Julián Andrés Rengifo Herrera
Laboratory of Advanced Oxidation Processes and Photocatalysis (LAPh), Centro de Investigación y Desarrollo en Ciencias Aplicadas “Dr. J.J. Ronco” (CINDECA), Departamento de Química, Facultad de Ciencias Exactas, UNLP-CCT La Plata, CONICET, 47 No. 257, 1900 La Plata, Buenos Aires, Argentina
3 shared publications - Janeth Sanabria
Universidad del Valle
2 shared publications Alejandra García-Barco
Grupo Investigación en Fotocatálisis y Estado Sólido, Universidad Tecnológica de Pereira, Escuela de Química, Pereira, Risaralda, 660003, Colombia
1 shared publicationAlexander Villarreal Díaz
Universidad del Tolima
1 shared publication
Latest Publications
- 21 November 2019
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 27 (2) , 1608-1624
Photo-Fenton process at natural conditions of pH, iron, ions, and humic acids for degradation of diuron and amoxicillin
Effect of ferric ions at concentrations typically found in natural waters (0.05 to 1.06 mg L−1) and low H2O2 concentrations (between 0.5 and 17.9 mg L−1) on simulated sunlight-induced (300 W m−2) photo-Fenton degradation at initial neutral pH (7.0) of amoxicillin and diuron in Milli-Q water was studied using an rotatable central composite experimental design 22 with a central and two axial points. H2O2 concentration was the parameter playing the key role on the degradation of both pollutants. Despite that initial pH was 7.0 in Milli-Q water, this latter decreased rapidly in the first minutes, reaching values of 3.5 and 5.0 for diuron and amoxicillin respectively after 15 min of simulated sunlight irradiation. In contrast, in presence of bicarbonate/carbonate (HCO3−/CO3=), fluoride (F−), and humic acids (HAs) at concentrations found often in surface and well waters with ferric ion and H2O2 concentrations of 0.3 and 9.7 and 15.2 mg L−1 respectively, both pollutants exhibited a strong degradation keeping the circumneutral pH. Amoxicillin and diuron degradation byproducts found by HPLC/MS were compatible with HO• and/or CO3–• radical attack. Several photo-induced processes such as photo-Fenton (by dissolved ferric-HA complexes), heterogeneous photocatalysis (by colloidal iron), UV-B H2O2 photolysis, irradiated-dissolved organic matter, and their reactions with pollutants would be the main oxidative route responsible of degradations. These findings demonstrated that it could be possible using iron concentrations often found in natural waters to oxidize via photo-Fenton processes among other events, organic pollutants at natural pH conditions.
- 21 November 2019
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 27 (2) , 1608-1624
Photo-Fenton process at natural conditions of pH, iron, ions, and humic acids for degradation of diuron and amoxicillin
Effect of ferric ions at concentrations typically found in natural waters (0.05 to 1.06 mg L−1) and low H2O2 concentrations (between 0.5 and 17.9 mg L−1) on simulated sunlight-induced (300 W m−2) photo-Fenton degradation at initial neutral pH (7.0) of amoxicillin and diuron in Milli-Q water was studied using an rotatable central composite experimental design 22 with a central and two axial points. H2O2 concentration was the parameter playing the key role on the degradation of both pollutants. Despite that initial pH was 7.0 in Milli-Q water, this latter decreased rapidly in the first minutes, reaching values of 3.5 and 5.0 for diuron and amoxicillin respectively after 15 min of simulated sunlight irradiation. In contrast, in presence of bicarbonate/carbonate (HCO3−/CO3=), fluoride (F−), and humic acids (HAs) at concentrations found often in surface and well waters with ferric ion and H2O2 concentrations of 0.3 and 9.7 and 15.2 mg L−1 respectively, both pollutants exhibited a strong degradation keeping the circumneutral pH. Amoxicillin and diuron degradation byproducts found by HPLC/MS were compatible with HO• and/or CO3–• radical attack. Several photo-induced processes such as photo-Fenton (by dissolved ferric-HA complexes), heterogeneous photocatalysis (by colloidal iron), UV-B H2O2 photolysis, irradiated-dissolved organic matter, and their reactions with pollutants would be the main oxidative route responsible of degradations. These findings demonstrated that it could be possible using iron concentrations often found in natural waters to oxidize via photo-Fenton processes among other events, organic pollutants at natural pH conditions.
- 1 December 2018
- Published by Elsevier in Solar Energy
- Vol. 176, 581-588
An integrated drinking water production system to remove chemical and microbiological pollution from natural groundwater by a coupled prototype helio-photochemical/H2O2/rapid sand filtration/chlorination powered by photovoltaic cell
- 1 December 2018
- Published by Elsevier in Solar Energy
- Vol. 176, 581-588
An integrated drinking water production system to remove chemical and microbiological pollution from natural groundwater by a coupled prototype helio-photochemical/H2O2/rapid sand filtration/chlorination powered by photovoltaic cell
- 26 June 2017
- Published by Wiley in Photochemistry and Photobiology
- Vol. 93 (5) , 1224-1231
Addition of Hydrogen Peroxide to Groundwater with Natural Iron Induces Water Disinfection by Photo‐Fenton at Circumneutral pH and other Photochemical Events
Samples of natural groundwater (with low turbidity, neutral pH and 0.3 mg L−1 iron concentration) inoculated with Escherichia coli K‐12 were exposed to simulated solar light both in the presence and in the absence 10 mg L−1 of H2O2. Results demonstrated that the viability of E. coli (by DVC–FISH) was grounded to zero after 360 min of irradiation. This abatement could be caused by the oxidative stress induced by radicals or another photo‐induced reactive oxygen species. Two 23 factorial experimental designs enabled the evaluation of the effects of chemical factors on the inactivation of E. coli. The first experimental design considered the pH, iron and H2O2, while the second evaluated the ions fluoride, carbonate and phosphate found in groundwater. pH was found to play a key role in the inactivation of E. coli. The best reduction in viability was obtained at the lower pH (6.75), while a nonsignificant effect was observed when iron or H2O2 concentrations were raised. At higher concentrations, anions, such as carbonate and phosphate, negatively affected the E. coli abatement. However, a higher concentration of fluoride accelerated it. In all experiments, the pH was observed to rise to values higher than 8.0 units after 360 min of treatment.
- 26 June 2017
- Published by Wiley in Photochemistry and Photobiology
- Vol. 93 (5) , 1224-1231
Addition of Hydrogen Peroxide to Groundwater with Natural Iron Induces Water Disinfection by Photo‐Fenton at Circumneutral pH and other Photochemical Events
Samples of natural groundwater (with low turbidity, neutral pH and 0.3 mg L−1 iron concentration) inoculated with Escherichia coli K‐12 were exposed to simulated solar light both in the presence and in the absence 10 mg L−1 of H2O2. Results demonstrated that the viability of E. coli (by DVC–FISH) was grounded to zero after 360 min of irradiation. This abatement could be caused by the oxidative stress induced by radicals or another photo‐induced reactive oxygen species. Two 23 factorial experimental designs enabled the evaluation of the effects of chemical factors on the inactivation of E. coli. The first experimental design considered the pH, iron and H2O2, while the second evaluated the ions fluoride, carbonate and phosphate found in groundwater. pH was found to play a key role in the inactivation of E. coli. The best reduction in viability was obtained at the lower pH (6.75), while a nonsignificant effect was observed when iron or H2O2 concentrations were raised. At higher concentrations, anions, such as carbonate and phosphate, negatively affected the E. coli abatement. However, a higher concentration of fluoride accelerated it. In all experiments, the pH was observed to rise to values higher than 8.0 units after 360 min of treatment.
- 20 June 2016
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 24 (7) , 6213-6221
2,4-D abatement from groundwater samples by photo-Fenton processes at circumneutral pH using naturally iron present. Effect of inorganic ions
This study evaluated, at laboratory scale, if the using iron naturally present (0.3 mg L−1) and adding 10 mg L−1 of hydrogen peroxide was effective to remove 24.3 mgL−1 of 2,4-dichlorophenoxyacetic acid (2,4-D) from groundwater samples by simulated solar irradiation (global intensity = 300 W m−2). Under these conditions, the degradation of 2,4-D reached 75.2 % and the apparition of its main oxidation byproduct 2,4-dichlorophenol (DCP) was observed. On the other hand, pH exhibited an increasing from 7.0 to 8.3 during the experiment. Experiments using Milli-Q water at pH 7.0, iron, and H2O2 concentrations of 0.3 and 10 mg L−1, respectively, were carried out in order to study the effect of ions such as carbonate species, phosphate, and fluoride in typical concentrations often found in groundwater. Ion concentrations were combined by using a factorial experimental design 23. Results showed that carbonates and fluoride did not produce a detrimental effect on the 2,4-D degradation, while phosphate inhibited the process. In this case, the pH increased also from 7.0 to 7.95 and 8.99. Effect of parameters such as pH, iron concentration, and hydrogen peroxide concentration on the 2,4-D degradation by the photo-Fenton process in groundwater was evaluated by using a factorial experimental design 23. Results showed that the pH was the main parameter affecting the process. This study shows for the first time that using the photo-Fenton process at circumneutral pH and iron naturally present seems to be a promising process to remove pesticides from groundwater.
- 20 June 2016
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 24 (7) , 6213-6221
2,4-D abatement from groundwater samples by photo-Fenton processes at circumneutral pH using naturally iron present. Effect of inorganic ions
This study evaluated, at laboratory scale, if the using iron naturally present (0.3 mg L−1) and adding 10 mg L−1 of hydrogen peroxide was effective to remove 24.3 mgL−1 of 2,4-dichlorophenoxyacetic acid (2,4-D) from groundwater samples by simulated solar irradiation (global intensity = 300 W m−2). Under these conditions, the degradation of 2,4-D reached 75.2 % and the apparition of its main oxidation byproduct 2,4-dichlorophenol (DCP) was observed. On the other hand, pH exhibited an increasing from 7.0 to 8.3 during the experiment. Experiments using Milli-Q water at pH 7.0, iron, and H2O2 concentrations of 0.3 and 10 mg L−1, respectively, were carried out in order to study the effect of ions such as carbonate species, phosphate, and fluoride in typical concentrations often found in groundwater. Ion concentrations were combined by using a factorial experimental design 23. Results showed that carbonates and fluoride did not produce a detrimental effect on the 2,4-D degradation, while phosphate inhibited the process. In this case, the pH increased also from 7.0 to 7.95 and 8.99. Effect of parameters such as pH, iron concentration, and hydrogen peroxide concentration on the 2,4-D degradation by the photo-Fenton process in groundwater was evaluated by using a factorial experimental design 23. Results showed that the pH was the main parameter affecting the process. This study shows for the first time that using the photo-Fenton process at circumneutral pH and iron naturally present seems to be a promising process to remove pesticides from groundwater.
- Open Access
- 1 May 2010
- Published by Universidad Nacional de Colombia in Ingeniería e Investigación
- Vol. 30 (2) , 87-95
Treatment of COD analysis liquid wastes generated in environmental laboratories
COD analysis is often carried out in environmental labs. Its wastes are considered hazardous due to the content of metals such as Cr, Ag and Hg; treating these wastes is considered complex and expensive. The experimental results of metal ion precipitation in COD wastes with affordable chemical products are reported in this work. Cr (VI) was chemically reduced by adding 200 mg.L-1 of glucose to Cr (III). Final Cr(VI) concentration was less than 0.5 mg.L-1. Cr (III) was precipitated as a metallic hydroxide by adding NaOH and Ag was reduced to less than 0.2 mg.L-1 by adding 2 g.L-1 of NaCl. Hg was reduced to less than 0.005 mg.L-1 with 10 g.L-1 of FeS. The proposed reduction-precipitation methodology allowed minimising the liquid residue's hazardous characteristics so that it complied with the maximum allowable values established in Chapter 6, Article 74 of Decree 1594/1984 that regulates the use of water and liquid residues.
- 1 May 2010
- Published by Universidad Nacional de Colombia in Ingeniería e Investigación
- Vol. 30 (2) , 87-95
Open AccessTreatment of COD analysis liquid wastes generated in environmental laboratories
COD analysis is often carried out in environmental labs. Its wastes are considered hazardous due to the content of metals such as Cr, Ag and Hg; treating these wastes is considered complex and expensive. The experimental results of metal ion precipitation in COD wastes with affordable chemical products are reported in this work. Cr (VI) was chemically reduced by adding 200 mg.L-1 of glucose to Cr (III). Final Cr(VI) concentration was less than 0.5 mg.L-1. Cr (III) was precipitated as a metallic hydroxide by adding NaOH and Ag was reduced to less than 0.2 mg.L-1 by adding 2 g.L-1 of NaCl. Hg was reduced to less than 0.005 mg.L-1 with 10 g.L-1 of FeS. The proposed reduction-precipitation methodology allowed minimising the liquid residue's hazardous characteristics so that it complied with the maximum allowable values established in Chapter 6, Article 74 of Decree 1594/1984 that regulates the use of water and liquid residues.
- 1 August 2002
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 373 (8) , 704-709
Analysis and toxicity of methomyl and ametryn after biodegradation
The controlled biodegradation of ametryn and methomyl has been performed, in accordance with the OECD Zahn–Wellens/EMPA procedure, by use of an enriched mixture of activated sludge collected from three domestic waste-water-treatment plants (WWTP). During the process concentrations of ametryn and methomyl in the water samples were isolated by solid-phase extraction (SPE); recovery rates were 98.9 and 93.2 for methomyl and ametryn, respectively. Liquid chromatography–mass spectrometry (LC–MS) was used to determine final pesticide concentrations and for metabolite identification. The efficiency of aerobic biodegradation of ametryn and methomyl was evaluated by measuring both the decrease in the concentration of the pesticides and global properties such as the chemical oxygen demand (COD). The acute toxicity of ametryn and methomyl was evaluated by use of the ToxAlert100 biological test, which is based on inhibition of the bioluminescence of Vibrio fischeri. There was significant correlation between results from primary and ultimate biodegradation and those from determination of toxicity. Pesticide concentrations were always reduced to below the limit of detection in less than 17 days. High COD removal (90–96%) was achieved in 28 and 18 days for methomyl and ametryn, respectively.
- 1 August 2002
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 373 (8) , 704-709
Analysis and toxicity of methomyl and ametryn after biodegradation
The controlled biodegradation of ametryn and methomyl has been performed, in accordance with the OECD Zahn–Wellens/EMPA procedure, by use of an enriched mixture of activated sludge collected from three domestic waste-water-treatment plants (WWTP). During the process concentrations of ametryn and methomyl in the water samples were isolated by solid-phase extraction (SPE); recovery rates were 98.9 and 93.2 for methomyl and ametryn, respectively. Liquid chromatography–mass spectrometry (LC–MS) was used to determine final pesticide concentrations and for metabolite identification. The efficiency of aerobic biodegradation of ametryn and methomyl was evaluated by measuring both the decrease in the concentration of the pesticides and global properties such as the chemical oxygen demand (COD). The acute toxicity of ametryn and methomyl was evaluated by use of the ToxAlert100 biological test, which is based on inhibition of the bioluminescence of Vibrio fischeri. There was significant correlation between results from primary and ultimate biodegradation and those from determination of toxicity. Pesticide concentrations were always reduced to below the limit of detection in less than 17 days. High COD removal (90–96%) was achieved in 28 and 18 days for methomyl and ametryn, respectively.