Avni Jain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Avni Jain has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
M. Acito
Politecnico di Milano
3 shared publicationsAndrei V. Metrikine
Faculty of Civil Engineering and Geosciences (CEG) Department of Engineering Structures TU Delft Stevinweg 1 2628 CN Delft The Netherlands
2 shared publications- George Lavidas
Delft University of Technology
2 shared publications - Jian Tan
Faculty of Civil Engineering and Geosciences, Delft University of Technology, Stevinweg, 1, 2628 CN Delft, the Netherlands
2 shared publications Karel N. van Dalen
2 shared publicationsA. V. Metrikine
Faculty of Civil Engineering and Geosciences (CEG), Department of Engineering Structures, TU Delft, Delft, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 21 May 2025
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 13 (5) , 994
The Impacts of Power Take-Off Surviving Strategies on the Extreme Load Estimations of Wave Energy Converters
The proper design of wave energy converters (WECs) is crucial for ensuring robustness in harsh wave climates without incurring the additional expense of unnecessary overdesign. The power take-off (PTO) mechanism, serving as a vital link between the moving body and the electric generator, is a key component in the design load analysis of WECs. However, the setting of PTO system parameters significantly impacts the dynamic behavior of the entire WEC system, leading to alterations in estimated loads. This work is dedicated to studying the influence of PTO control strategies on the identification of extreme loads of a heaving point absorber WEC. A nonlinear time-domain model is established to estimate the dynamic responses and loads of the WEC. Both PTO loads and end-stop loads under extreme conditions are examined, considering the wave climate of a realistic sea site. The results suggest that the PTO setting strategies significantly impact the extreme load exerted on both the PTO system and the end-stop system. Varying the PTO damping within a certain range could lead to a difference of 57% and 63% in short-term extreme loads for the PTO system and the end-stop system, respectively. Furthermore, the impacts of the PTO control strategy appear to be specific to each WEC component. The PTO parameters selected for reducing the extreme PTO loads might increase the extreme end-stop loads. A holistic examination is therefore recommended for estimating the extreme loads of WECs.
- 21 May 2025
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 13 (5) , 994
Open AccessThe Impacts of Power Take-Off Surviving Strategies on the Extreme Load Estimations of Wave Energy Converters
The proper design of wave energy converters (WECs) is crucial for ensuring robustness in harsh wave climates without incurring the additional expense of unnecessary overdesign. The power take-off (PTO) mechanism, serving as a vital link between the moving body and the electric generator, is a key component in the design load analysis of WECs. However, the setting of PTO system parameters significantly impacts the dynamic behavior of the entire WEC system, leading to alterations in estimated loads. This work is dedicated to studying the influence of PTO control strategies on the identification of extreme loads of a heaving point absorber WEC. A nonlinear time-domain model is established to estimate the dynamic responses and loads of the WEC. Both PTO loads and end-stop loads under extreme conditions are examined, considering the wave climate of a realistic sea site. The results suggest that the PTO setting strategies significantly impact the extreme load exerted on both the PTO system and the end-stop system. Varying the PTO damping within a certain range could lead to a difference of 57% and 63% in short-term extreme loads for the PTO system and the end-stop system, respectively. Furthermore, the impacts of the PTO control strategy appear to be specific to each WEC component. The PTO parameters selected for reducing the extreme PTO loads might increase the extreme end-stop loads. A holistic examination is therefore recommended for estimating the extreme loads of WECs.
- Open Access
- 4 January 2025
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 13 (1) , 1-12
Railway Transition Zones: Energy Evaluation of a Novel Transition Structure for Critical Loading Conditions
Railway transition zones (RTZs) are subjected to amplified degradation leading to high maintenance costs and reduced availability of tracks for operation. Over the years, several mitigation measures have been investigated to deal with the amplified degradation of these zones. However, to ensure the robustness of a design solution, it must be evaluated for critical conditions arising due to certain loading and track conditions. In this paper, the critical load conditions arising due to different velocities (sub-critical, critical and super-critical), the direction of the moving load, the combination of inertial effects and track imperfections (non-straight rail and hanging sleepers) and passage of multiple axles (using a comprehensive vehicle model) are investigated for an embankment-bridge transition. The results are then compared against the recently proposed design of a transition structure called SHIELD (Safe Hull Inspired Energy Limiting Design) to evaluate its performance under these critical conditions using various vehicle models and finite element models of the RTZs. It was found that the novel design of the transition structure effectively mitigates dynamic amplifications and results in smooth strain energy distribution across sub-critical, critical, and super-critical velocity regimes in both directions of movement implying that the expected operation-induced degradation will be as uniform as possible in longitudinal direction. Furthermore, even though this transition structure is designed to deal with initial track conditions (perfectly straight track), its superior performance is not confined to tracks in perfect condition; it also efficiently addresses adverse effects from track imperfections such as hanging sleepers and non-straight rail. In the end, this work demonstrates the robustness of the design solution for all the critical conditions under study.
- 4 January 2025
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 13 (1) , 1-12
Open AccessRailway Transition Zones: Energy Evaluation of a Novel Transition Structure for Critical Loading Conditions
Railway transition zones (RTZs) are subjected to amplified degradation leading to high maintenance costs and reduced availability of tracks for operation. Over the years, several mitigation measures have been investigated to deal with the amplified degradation of these zones. However, to ensure the robustness of a design solution, it must be evaluated for critical conditions arising due to certain loading and track conditions. In this paper, the critical load conditions arising due to different velocities (sub-critical, critical and super-critical), the direction of the moving load, the combination of inertial effects and track imperfections (non-straight rail and hanging sleepers) and passage of multiple axles (using a comprehensive vehicle model) are investigated for an embankment-bridge transition. The results are then compared against the recently proposed design of a transition structure called SHIELD (Safe Hull Inspired Energy Limiting Design) to evaluate its performance under these critical conditions using various vehicle models and finite element models of the RTZs. It was found that the novel design of the transition structure effectively mitigates dynamic amplifications and results in smooth strain energy distribution across sub-critical, critical, and super-critical velocity regimes in both directions of movement implying that the expected operation-induced degradation will be as uniform as possible in longitudinal direction. Furthermore, even though this transition structure is designed to deal with initial track conditions (perfectly straight track), its superior performance is not confined to tracks in perfect condition; it also efficiently addresses adverse effects from track imperfections such as hanging sleepers and non-straight rail. In the end, this work demonstrates the robustness of the design solution for all the critical conditions under study.
- Open Access
- 25 September 2024
- Published by Springer Nature in Research Square
Railway transition zones: energy evaluation of a novel transition structure for critical loading conditions
Railway transition zones (RTZs) are subjected to amplified degradation leading to high maintenance costs and reduced availability of tracks for operation. Over the years, several mitigation measures have been investigated to deal with the amplified degradation of these zones. However, to ensure the robustness of a design solution, it must be evaluated for critical conditions arising due to certain loading and track conditions. In this paper, the critical load conditions arising due to different velocities (sub-critical, critical and super-critical), the direction of the moving load, the combination of inertial effects and track imperfections (non-straight rail and hanging sleepers) and passage of multiple axles (using a comprehensive vehicle model) are investigated for an embankment-bridge transition. The results are then compared against the recently proposed design of a transition structure called SHIELD (Safe Hull Inspired Energy Limiting Design) to evaluate its performance under these critical conditions using various vehicle models and finite element models of the RTZs. It was found that the novel design of the transition structure effectively mitigates dynamic amplifications and results in smooth strain energy distribution across subcritical, critical, and super-critical velocity regimes in both directions of movement implying that the expected operation-induced degradation will be as uniform as possible in longitudinal direction. Furthermore, even though this transition structure is designed to deal with initial track conditions (perfectly straight track), its superior performance is not confined to tracks in perfect condition; it also efficiently addresses adverse effects from track imperfections such as hanging sleepers and non-straight rail. In the end, this work demonstrates the robustness of the design solution for all the critical conditions under study.
- 25 September 2024
- Published by Springer Nature in Research Square
Open AccessRailway transition zones: energy evaluation of a novel transition structure for critical loading conditions
Railway transition zones (RTZs) are subjected to amplified degradation leading to high maintenance costs and reduced availability of tracks for operation. Over the years, several mitigation measures have been investigated to deal with the amplified degradation of these zones. However, to ensure the robustness of a design solution, it must be evaluated for critical conditions arising due to certain loading and track conditions. In this paper, the critical load conditions arising due to different velocities (sub-critical, critical and super-critical), the direction of the moving load, the combination of inertial effects and track imperfections (non-straight rail and hanging sleepers) and passage of multiple axles (using a comprehensive vehicle model) are investigated for an embankment-bridge transition. The results are then compared against the recently proposed design of a transition structure called SHIELD (Safe Hull Inspired Energy Limiting Design) to evaluate its performance under these critical conditions using various vehicle models and finite element models of the RTZs. It was found that the novel design of the transition structure effectively mitigates dynamic amplifications and results in smooth strain energy distribution across subcritical, critical, and super-critical velocity regimes in both directions of movement implying that the expected operation-induced degradation will be as uniform as possible in longitudinal direction. Furthermore, even though this transition structure is designed to deal with initial track conditions (perfectly straight track), its superior performance is not confined to tracks in perfect condition; it also efficiently addresses adverse effects from track imperfections such as hanging sleepers and non-straight rail. In the end, this work demonstrates the robustness of the design solution for all the critical conditions under study.
- Open Access
- 24 April 2024
- Published by Frontiers Media SA in Frontiers in Built Environment
- Vol. 10, 1285131
Dynamic amplifications in railway transition zones: performance evaluation of sleeper configurations using energy criterion
Railway transition zones present a major challenge in railway track design mainly due to abrupt jumps in stiffness and differential settlements that result from crossing stiffer structures such as bridges or culverts. Despite numerous efforts to mitigate these transition effects at both the superstructure and substructure levels, a comprehensive solution remains elusive. Substructure-level interventions have demonstrated some effectiveness but are often cost-prohibitive and challenging to implement in existing operational railway transition zones. In contrast, mitigation measures at the superstructure (rail, sleepers, rail-pads, under-sleeper pads) level can be easily installed but have shown limited improvement in site measurements. This study evaluates the influence of different sleeper configurations in transition zones and reduced sleeper spacings on the operation-driven dynamic amplifications in railway transition zones, employing a recently proposed criterion based on the total strain energy in the track-bed layers (ballast, embankment, and subgrade). In addition to this, the influence of the loss of contact between sleepers and ballast (i.e., hanging sleepers), which typically results from the differential settlement, is studied. The first part of the paper provides useful insights regarding the interventions (and/or initial design) in the sleeper configuration and spacing, whereas the second part of the work highlights the need for interventions to deal with the loss of contact between sleeper and ballast. A 2-dimensional finite element model of an embankment-bridge transition was used for the analysis. The results show that it is not possible to mitigate the transition effects completely using the interventions involving sleeper spacing and configuration.
- 24 April 2024
- Published by Frontiers Media SA in Frontiers in Built Environment
- Vol. 10, 1285131
Open AccessDynamic amplifications in railway transition zones: performance evaluation of sleeper configurations using energy criterion
Railway transition zones present a major challenge in railway track design mainly due to abrupt jumps in stiffness and differential settlements that result from crossing stiffer structures such as bridges or culverts. Despite numerous efforts to mitigate these transition effects at both the superstructure and substructure levels, a comprehensive solution remains elusive. Substructure-level interventions have demonstrated some effectiveness but are often cost-prohibitive and challenging to implement in existing operational railway transition zones. In contrast, mitigation measures at the superstructure (rail, sleepers, rail-pads, under-sleeper pads) level can be easily installed but have shown limited improvement in site measurements. This study evaluates the influence of different sleeper configurations in transition zones and reduced sleeper spacings on the operation-driven dynamic amplifications in railway transition zones, employing a recently proposed criterion based on the total strain energy in the track-bed layers (ballast, embankment, and subgrade). In addition to this, the influence of the loss of contact between sleepers and ballast (i.e., hanging sleepers), which typically results from the differential settlement, is studied. The first part of the paper provides useful insights regarding the interventions (and/or initial design) in the sleeper configuration and spacing, whereas the second part of the work highlights the need for interventions to deal with the loss of contact between sleeper and ballast. A 2-dimensional finite element model of an embankment-bridge transition was used for the analysis. The results show that it is not possible to mitigate the transition effects completely using the interventions involving sleeper spacing and configuration.
- 8 November 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 18 (4) , 1371-1400
The seismic sequence of 2016–2017 in Central Italy: a numerical insight on the survival of the Civic Tower in Amatrice
- 8 November 2019
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 18 (4) , 1371-1400
The seismic sequence of 2016–2017 in Central Italy: a numerical insight on the survival of the Civic Tower in Amatrice
- 21 August 2019
- Published by Taylor & Francis
- p. 1956-1961
RCFST columns exposed to fire: Residual compression test results discussion
This paper presents a discussion on the experimental results of the compression tests performed on full-scale fire-exposed, Reinforced Concrete-Filled Steel Tubes (RCFST) and Reinforced Concrete (RC) short columns (outer diameter 457 mm and length 1600 mm). In the companion papers, full details about the test procedure, thermal field, load-displacement curves are provided. In particular, the domain of research work includes the results of five tests for thermal field measurements, that consider four specimens heated in a gas furnace in standard fire conditions (ISO 834), one specimen heated in an electric furnace in non-standard conditions and the results of six axial compressive tests. In this paper, the results of residual compression tests are discussed and an analytical-experimental comparison is proposed. The work concludes with main remarks about the experimental results.
- 21 August 2019
- Published by Taylor & Francis
- p. 1956-1961
RCFST columns exposed to fire: Residual compression test results discussion
This paper presents a discussion on the experimental results of the compression tests performed on full-scale fire-exposed, Reinforced Concrete-Filled Steel Tubes (RCFST) and Reinforced Concrete (RC) short columns (outer diameter 457 mm and length 1600 mm). In the companion papers, full details about the test procedure, thermal field, load-displacement curves are provided. In particular, the domain of research work includes the results of five tests for thermal field measurements, that consider four specimens heated in a gas furnace in standard fire conditions (ISO 834), one specimen heated in an electric furnace in non-standard conditions and the results of six axial compressive tests. In this paper, the results of residual compression tests are discussed and an analytical-experimental comparison is proposed. The work concludes with main remarks about the experimental results.
- 21 August 2019
- Published by Taylor & Francis
- p. 2136-2141
Historical reinforced concrete arch bridges of Songavazzo and Brivio (Italy): Dynamic identification and seismic vulnerability assessment
The problem of seismic safety assessment is discussed with reference to the case of an historical reinforced concrete bridge; specifically, a bridge located in Songavazzo, Italy across the Valeggia river, completed in 1911. Experimental testing has been performed, providing all the required information for the identification of the dynamic behaviour. Seismic vulnerability has been evaluated with both response spectrum modal analyses and nonlinear static (push-over) analyses as well. The bridge response is compared to the one obtained for a similar bridge yet reflecting a different structural scheme. Structural analyses have allowed to highlight different structural concepts while, on the other hand, they show the complementary nature of the two bridges. In both cases, reinforced concrete arches are mainly subjected to axial loads and provide the main structural system.
- 21 August 2019
- Published by Taylor & Francis
- p. 2136-2141
Historical reinforced concrete arch bridges of Songavazzo and Brivio (Italy): Dynamic identification and seismic vulnerability assessment
The problem of seismic safety assessment is discussed with reference to the case of an historical reinforced concrete bridge; specifically, a bridge located in Songavazzo, Italy across the Valeggia river, completed in 1911. Experimental testing has been performed, providing all the required information for the identification of the dynamic behaviour. Seismic vulnerability has been evaluated with both response spectrum modal analyses and nonlinear static (push-over) analyses as well. The bridge response is compared to the one obtained for a similar bridge yet reflecting a different structural scheme. Structural analyses have allowed to highlight different structural concepts while, on the other hand, they show the complementary nature of the two bridges. In both cases, reinforced concrete arches are mainly subjected to axial loads and provide the main structural system.
- 1 January 1996
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (10514651) , 770-774 vol.1
From images to models: automatic 3D object model construction from multiple views
Automatic 3D object model construction is important in applications ranging from manufacturing to entertainment industry, since CAD models of existing objects may be either unavailable or unusable. We describe a prototype system for automatically registering and integrating multiple views of objects using surface depth data to construct their geometric models. New techniques for handling key issues such as robust estimation of view transformations relating multiple views and seamless integration of registered data to form an unbroken surface have been proposed and implemented in our system. Our system has been tested on depth data that were obtained using digital interferometry techniques as well as a laser range scanner. Experimental results on real object surfaces demonstrate the good performance of our system.
- 1 January 1996
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (10514651) , 770-774 vol.1
From images to models: automatic 3D object model construction from multiple views
Automatic 3D object model construction is important in applications ranging from manufacturing to entertainment industry, since CAD models of existing objects may be either unavailable or unusable. We describe a prototype system for automatically registering and integrating multiple views of objects using surface depth data to construct their geometric models. New techniques for handling key issues such as robust estimation of view transformations relating multiple views and seamless integration of registered data to form an unbroken surface have been proposed and implemented in our system. Our system has been tested on depth data that were obtained using digital interferometry techniques as well as a laser range scanner. Experimental results on real object surfaces demonstrate the good performance of our system.