Lorenz Butzhammer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lorenz Butzhammer has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Tino Hausotte
Chair of Manufacturing Metrology (FMT) Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU Erlangen Germany
11 shared publications University of Erlangen-Nürnberg (FAU)
3 shared publications- Gabriel Herl
Deggendorf Institute of Technology, Deggendorf, Germany
2 shared publications - Simon Wittl
Deggendorf Institute of Technology Germany
2 shared publications - Tamara Reuter
Chair of Manufacturing Metrology (FMT) Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU Erlangen Germany
2 shared publications Anahita Movahedi
1 shared publication
Latest Publications
- 1 July 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (7)
Position- and direction-dependent 3D spatial resolution evaluation for Computed Tomography using extended Modulation Transfer Function analysis
As industrial computed tomography (CT) systems evolve toward robotic CT and freely selectable three-dimensional acquisition trajectories, spatial resolution must be evaluated not only globally but also with respect to position and direction within the three-dimensional measuring volume. The modulation transfer function (MTF) is a key metric for spatial resolution, yet the widely used ASTM E1695−20 method, based on edge response analysis of cylindrical objects, provides only averaged axial-plane values and lacks directional information. To overcome these limitations, this contribution proposes an extended MTF evaluation approach suitable for advanced 3D trajectories. The method analyzes individual gray value profiles along lines perpendicular to object surfaces and applies local averaging to improve robustness against voxel grid effects and noise. While a cylindrical object is used for comparability with ASTM E1695−20, a spherical object enables full 3D directional MTF assessment.
- 1 July 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (7)
Position- and direction-dependent 3D spatial resolution evaluation for Computed Tomography using extended Modulation Transfer Function analysis
As industrial computed tomography (CT) systems evolve toward robotic CT and freely selectable three-dimensional acquisition trajectories, spatial resolution must be evaluated not only globally but also with respect to position and direction within the three-dimensional measuring volume. The modulation transfer function (MTF) is a key metric for spatial resolution, yet the widely used ASTM E1695−20 method, based on edge response analysis of cylindrical objects, provides only averaged axial-plane values and lacks directional information. To overcome these limitations, this contribution proposes an extended MTF evaluation approach suitable for advanced 3D trajectories. The method analyzes individual gray value profiles along lines perpendicular to object surfaces and applies local averaging to improve robustness against voxel grid effects and noise. While a cylindrical object is used for comparability with ASTM E1695−20, a spherical object enables full 3D directional MTF assessment.
- 13 May 2026
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 93 (5-6) , 279-290
Evaluation of digital models for dimensional X-ray computed tomography – analysis of a multi feature check measurement
Digital models using computer simulation for the acquisition of X-ray projections offer the possibility to virtually perform a X-ray computed tomography (CT) measurement. Virtual CT scans benefit research and development of X-ray computed tomography, serving various purposes while reducing physical scan time and therefore cost. The accuracy of a digital model determines its utility. Suitable test procedures of digital models can assure the sufficient accuracy of a digital model regarding a specific task. For the use of digital models in dimensional metrology an agreement of dimensional measurands compared to a physical counterpart is important. In this contribution, a physical and virtual CT measurements of a calibrated Multi Feature Check mini specimen are evaluated regarding surface transition metrics of the volume data and its metrological compatibility of dimensional measurands. For the evaluation of the gray value response at the surface transition, a methodology that uses local sampling patterns to generate a locally averaged edge response is presented. The digital model shows promising results to serve as a basis for further extension to determine the measurement uncertainty of dimensional CT measurements using the Monte-Carlo method in the future.
- 13 May 2026
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 93 (5-6) , 279-290
Evaluation of digital models for dimensional X-ray computed tomography – analysis of a multi feature check measurement
Digital models using computer simulation for the acquisition of X-ray projections offer the possibility to virtually perform a X-ray computed tomography (CT) measurement. Virtual CT scans benefit research and development of X-ray computed tomography, serving various purposes while reducing physical scan time and therefore cost. The accuracy of a digital model determines its utility. Suitable test procedures of digital models can assure the sufficient accuracy of a digital model regarding a specific task. For the use of digital models in dimensional metrology an agreement of dimensional measurands compared to a physical counterpart is important. In this contribution, a physical and virtual CT measurements of a calibrated Multi Feature Check mini specimen are evaluated regarding surface transition metrics of the volume data and its metrological compatibility of dimensional measurands. For the evaluation of the gray value response at the surface transition, a methodology that uses local sampling patterns to generate a locally averaged edge response is presented. The digital model shows promising results to serve as a basis for further extension to determine the measurement uncertainty of dimensional CT measurements using the Monte-Carlo method in the future.
- Open Access
- 19 March 2026
- Published by Elsevier in Precision Engineering
- Vol. 100, 377-400
Conversion between detector- and rotary-table-related misalignment parameterisations for unified projection-matrix-based geometry calibration in dimensional X-ray computed tomography
- 19 March 2026
- Published by Elsevier in Precision Engineering
- Vol. 100, 377-400
Open AccessConversion between detector- and rotary-table-related misalignment parameterisations for unified projection-matrix-based geometry calibration in dimensional X-ray computed tomography
- Open Access
- 1 March 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (3)
Higher accuracy with fewer projections? Automated scan angle selection for dimensional Computed Tomography based on a simple data completeness measure for the part surface
Selecting scan angles such that surface segments are aligned with straight X-ray paths (i.e., rays are tangential to the surface and therefore perpendicular to the local surface normal) is known to produce sharper transitions of those surface segments in the reconstructed volume. This enhances dimensional accuracy in sparse-view computed tomography (CT). However, existing approaches offer no direct means to exploit this criterion for automatic scan-angle optimization. We propose a method that uses a virtual representation of the CT setup, including an STL surface model of the inspected part, to automatically identify taskspecific scan angles. Using elementary vector calculus, the algorithm determines projection directions that generate tangential X-rays for targeted surface segments. To support different levels of geometric complexity, we introduce two variants of the angle-selection procedure. The methods were experimentally validated on two objects with distinct absorption and geometric characteristics. For a steel gauge block, employing the minimum number of task-specific projections required for surface-data completeness substantially outperformed a conventional high-projection scan. For a geometrically more complex test object, surface-related errors were still reduced within the region of interest. The proposed approach – particularly suited for flat surface structures and not accounting for image-degrading factors other than cone-beam artifacts – shows promise for high-throughput dimensional metrology of mono-material parts.
- 1 March 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (3)
Open AccessHigher accuracy with fewer projections? Automated scan angle selection for dimensional Computed Tomography based on a simple data completeness measure for the part surface
Selecting scan angles such that surface segments are aligned with straight X-ray paths (i.e., rays are tangential to the surface and therefore perpendicular to the local surface normal) is known to produce sharper transitions of those surface segments in the reconstructed volume. This enhances dimensional accuracy in sparse-view computed tomography (CT). However, existing approaches offer no direct means to exploit this criterion for automatic scan-angle optimization. We propose a method that uses a virtual representation of the CT setup, including an STL surface model of the inspected part, to automatically identify taskspecific scan angles. Using elementary vector calculus, the algorithm determines projection directions that generate tangential X-rays for targeted surface segments. To support different levels of geometric complexity, we introduce two variants of the angle-selection procedure. The methods were experimentally validated on two objects with distinct absorption and geometric characteristics. For a steel gauge block, employing the minimum number of task-specific projections required for surface-data completeness substantially outperformed a conventional high-projection scan. For a geometrically more complex test object, surface-related errors were still reduced within the region of interest. The proposed approach – particularly suited for flat surface structures and not accounting for image-degrading factors other than cone-beam artifacts – shows promise for high-throughput dimensional metrology of mono-material parts.
- Open Access
- 15 January 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (2) , 025401
Direct assessment of the influence of pose repeatability on the accuracy of dimensional measurements for computed tomography systems with high degrees of freedom
Industrial x-ray computed tomography (CT) systems with high geometric flexibility are increasingly utilized for large-scale measurement objects or challenging measurement tasks. To maintain high accuracy when deviating from the established circular scan trajectory, trajectory calibration methods using multi-sphere reference objects with known marker positions are commonly employed. These multi-sphere objects can either be scanned together with the measurement object (online trajectory calibration) or in a separate scan (offline trajectory calibration). While offline calibration increases machine time, it generally results in higher scan quality. However, a sufficient pose repeatability is necessary to ensure comparable or even superior accuracy to online calibration. In this contribution, we present a straightforward procedure to compare both types of trajectory calibration in a way that the differences of the results can directly be traced back to the influence of the pose repeatability. The multi-sphere reference object is not only used for trajectory calibration, but simultaneously as a measurement object for repeated measurements. The methodology is tested on both a twin robotic CT system and a conventional CT system that is additionally equipped with a hexapod manipulator for adaptive object tilting. Results showed, independent from the type of trajectory calibration, systematic measurement errors in the order of 10−5–10−4 of measured sphere distances and sphericity values below 50 μ m . For sphere distances, random errors were increased by a factor of 5 due to the offline trajectory calibration, but were still low ( < 1 μ m ) in comparison to systematic errors and the spread of different measurement features. Overall, both investigated systems demonstrated sufficient positioning repeatability for offline trajectory calibration. The method is in general also applicable to any other types of manipulator systems used for CT devices. It provides a workflow for the decision which type of trajectory calibration is preferable for a given CT system.
- 15 January 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (2) , 025401
Open AccessDirect assessment of the influence of pose repeatability on the accuracy of dimensional measurements for computed tomography systems with high degrees of freedom
Industrial x-ray computed tomography (CT) systems with high geometric flexibility are increasingly utilized for large-scale measurement objects or challenging measurement tasks. To maintain high accuracy when deviating from the established circular scan trajectory, trajectory calibration methods using multi-sphere reference objects with known marker positions are commonly employed. These multi-sphere objects can either be scanned together with the measurement object (online trajectory calibration) or in a separate scan (offline trajectory calibration). While offline calibration increases machine time, it generally results in higher scan quality. However, a sufficient pose repeatability is necessary to ensure comparable or even superior accuracy to online calibration. In this contribution, we present a straightforward procedure to compare both types of trajectory calibration in a way that the differences of the results can directly be traced back to the influence of the pose repeatability. The multi-sphere reference object is not only used for trajectory calibration, but simultaneously as a measurement object for repeated measurements. The methodology is tested on both a twin robotic CT system and a conventional CT system that is additionally equipped with a hexapod manipulator for adaptive object tilting. Results showed, independent from the type of trajectory calibration, systematic measurement errors in the order of 10−5–10−4 of measured sphere distances and sphericity values below 50 μ m . For sphere distances, random errors were increased by a factor of 5 due to the offline trajectory calibration, but were still low ( < 1 μ m ) in comparison to systematic errors and the spread of different measurement features. Overall, both investigated systems demonstrated sufficient positioning repeatability for offline trajectory calibration. The method is in general also applicable to any other types of manipulator systems used for CT devices. It provides a workflow for the decision which type of trajectory calibration is preferable for a given CT system.
- 1 August 2024
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 91 (s1) , 2-7
Task-specific scan trajectory modification for dimensional X-ray computed Tomography with high throughput
Zusammenfassung: Eine Erweiterung der Scantrajektorie für die industrielle Röntgen-Computertomographie von einer kreisförmigen Form (entsprechend einer 360°-Rotation des Messobjekts) hin zu frei wählbaren Aufnahmeposen hat das Potenzial, durch eine geeignete Trajektorienanpassung Messabweichungen zu reduzieren. In diesem Beitrag wird eine solche Trajektorienanpassung durch einen Hexapoden als Messobjektmanipulator und eine güteparameterbasierte Methodik zur Wahl einzelner Trajektorienpunkte erreicht. Die Ergebnisse zeigen, dass sich vor allem für eine geringe Projektionszahl signifikante Vorteile ergeben, was vor allem im Hinblick auf Inline-CT mit hohem Durchsatz von Relevanz ist.
- 1 August 2024
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 91 (s1) , 2-7
Task-specific scan trajectory modification for dimensional X-ray computed Tomography with high throughput
Zusammenfassung: Eine Erweiterung der Scantrajektorie für die industrielle Röntgen-Computertomographie von einer kreisförmigen Form (entsprechend einer 360°-Rotation des Messobjekts) hin zu frei wählbaren Aufnahmeposen hat das Potenzial, durch eine geeignete Trajektorienanpassung Messabweichungen zu reduzieren. In diesem Beitrag wird eine solche Trajektorienanpassung durch einen Hexapoden als Messobjektmanipulator und eine güteparameterbasierte Methodik zur Wahl einzelner Trajektorienpunkte erreicht. Die Ergebnisse zeigen, dass sich vor allem für eine geringe Projektionszahl signifikante Vorteile ergeben, was vor allem im Hinblick auf Inline-CT mit hohem Durchsatz von Relevanz ist.
- 9 July 2024
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 91 (9) , 466-479
Test of conformance or non-conformance with geometrical specifications
Systematic and random measurement errors are the cause of uncertain conformance and non-conformance statements. A wrong conformance statement occurs if the workpiece is accepted and is a reject part (type II error or false-negative) and a wrong non-conformance statement if the workpiece is rejected and is an in-spec part (type I error or false-positive). In order to avoid type I and type II errors, measurement uncertainty must be taken into account in the conformance and non-conformance testing. In practice, some procedures are used to consider measurement errors or the uncertainty that deviate from the state-of-the-art in research and technology. As these methods have become established over many years, they are still widely used despite better theoretical knowledge. The standard ISO 14253-1:2017 specifies a procedure based on probability and measurement uncertainty that is in accordance to the internationally accepted “Guide to the expression of uncertainty in measurement” and its supplements but is often not used due to the complexity of the evaluation of measurement uncertainty. In this contribution we give an overview and comparison of the different existing methods and provide an suggestion for supplementing the standard ISO 14253-1:2017, as Monte Carlo simulations enable a direct probability-based conformance and non-conformance testing even for complex measurement processes.
- 9 July 2024
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 91 (9) , 466-479
Test of conformance or non-conformance with geometrical specifications
Systematic and random measurement errors are the cause of uncertain conformance and non-conformance statements. A wrong conformance statement occurs if the workpiece is accepted and is a reject part (type II error or false-negative) and a wrong non-conformance statement if the workpiece is rejected and is an in-spec part (type I error or false-positive). In order to avoid type I and type II errors, measurement uncertainty must be taken into account in the conformance and non-conformance testing. In practice, some procedures are used to consider measurement errors or the uncertainty that deviate from the state-of-the-art in research and technology. As these methods have become established over many years, they are still widely used despite better theoretical knowledge. The standard ISO 14253-1:2017 specifies a procedure based on probability and measurement uncertainty that is in accordance to the internationally accepted “Guide to the expression of uncertainty in measurement” and its supplements but is often not used due to the complexity of the evaluation of measurement uncertainty. In this contribution we give an overview and comparison of the different existing methods and provide an suggestion for supplementing the standard ISO 14253-1:2017, as Monte Carlo simulations enable a direct probability-based conformance and non-conformance testing even for complex measurement processes.
- Open Access
- 1 March 2024
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 29 (3)
Uncalibrated CT Reconstruction for One-Shot Scanning of Arbitrary Trajectories
CT systems with high degrees of freedom such as robot-guided setups allow CT scanning with arbitrary 3D trajectories. However, many existing systems require an additional calibration scan to determine the exact source/detector poses of new trajectories. I....
- 1 March 2024
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 29 (3)
Open AccessUncalibrated CT Reconstruction for One-Shot Scanning of Arbitrary Trajectories
CT systems with high degrees of freedom such as robot-guided setups allow CT scanning with arbitrary 3D trajectories. However, many existing systems require an additional calibration scan to determine the exact source/detector poses of new trajectories. I....
- Open Access
- 28 October 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (1) , 015403
Calibration of 3D scan trajectories for an industrial computed tomography setup with 6-DOF object manipulator system using a single sphere
In industrial x-ray computed tomography (CT), the application of more complex scan paths in comparison to the typical circular trajectory ( rotation of the measurement object) can extend the potential of CT. One way to enable such 3D scan trajectories is to use a 6-degrees-of-freedom (DOF) object manipulator system. In our case, a hexapod is mounted on top of the rotary table of a commercial CT scanner. This allows for adaptive tilting of the measurement object during the scan. For high accuracy, the geometry calibration of such setups is typically done using the x-ray projections of a calibrated multi-sphere object. Contrary to this, here, we demonstrate a procedure that is based on only a single sphere and can therefore experimentally be implemented with low effort. Using the intrinsic geometry parameters of the CT device as prior information, the hexapod coordinate system with respect to the CT machine coordinate system is determined by means of a one-step optimization approach. The resulting parameters are used to calculate projection matrices that enable the volume reconstruction for 3D scan trajectories. The method is validated using simulated x-ray images and experimental investigations including dimensional measurements. For the used setup, geometric measurement results for 3D scan trajectories that are calibrated with the presented method show in sum increased errors compared to the circular scans. A limited pose accuracy of the manipulator system is discussed as a potential cause. The results nevertheless indicate that the presented method is generally feasible for dimensional CT measurements provided that the pose accuracy is sufficient. The calibration procedure can therefore be a low-cost and easier to implement alternative compared to trajectory calibration methods based on multi-sphere objects, but with a tendency towards lower measurement accuracy. The methodology can in principle be transferred to different setups with 6-DOF manipulator systems, e.g. C-arm CT devices with a robot arm.- 28 October 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (1) , 015403
Open AccessCalibration of 3D scan trajectories for an industrial computed tomography setup with 6-DOF object manipulator system using a single sphere
In industrial x-ray computed tomography (CT), the application of more complex scan paths in comparison to the typical circular trajectory ( rotation of the measurement object) can extend the potential of CT. One way to enable such 3D scan trajectories is to use a 6-degrees-of-freedom (DOF) object manipulator system. In our case, a hexapod is mounted on top of the rotary table of a commercial CT scanner. This allows for adaptive tilting of the measurement object during the scan. For high accuracy, the geometry calibration of such setups is typically done using the x-ray projections of a calibrated multi-sphere object. Contrary to this, here, we demonstrate a procedure that is based on only a single sphere and can therefore experimentally be implemented with low effort. Using the intrinsic geometry parameters of the CT device as prior information, the hexapod coordinate system with respect to the CT machine coordinate system is determined by means of a one-step optimization approach. The resulting parameters are used to calculate projection matrices that enable the volume reconstruction for 3D scan trajectories. The method is validated using simulated x-ray images and experimental investigations including dimensional measurements. For the used setup, geometric measurement results for 3D scan trajectories that are calibrated with the presented method show in sum increased errors compared to the circular scans. A limited pose accuracy of the manipulator system is discussed as a potential cause. The results nevertheless indicate that the presented method is generally feasible for dimensional CT measurements provided that the pose accuracy is sufficient. The calibration procedure can therefore be a low-cost and easier to implement alternative compared to trajectory calibration methods based on multi-sphere objects, but with a tendency towards lower measurement accuracy. The methodology can in principle be transferred to different setups with 6-DOF manipulator systems, e.g. C-arm CT devices with a robot arm. - Open Access
- 29 June 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (10) , 105402
Complex 3D scan trajectories for industrial cone-beam computed tomography using a hexapod
Industrial x-ray computed tomography (CT) represents an established measurement technique in the field of nondestructive testing and dimensional metrology. However, the measurement accuracy is sometimes limited by measurement artifacts that cannot be avoided using a standard circular scan trajectory. This problem can be addressed with the aid of flexible 3D trajectories, but up to date, the application of these is mainly restricted to special CT devices using robot arms. In this paper, we present results using a hexapod as an additional positioning system in a commercial industrial CT scanner. In addition to the 360∘rotation, task-specific tilting of the part during the scan is possible in this way. We used and adapted geometry calibration procedures based on a multi-sphere reference object to enable reconstruction with high accuracy. Using a demonstrator test fixture with high absorbing elements, we show that severe metal and truncation artifacts can be avoided for a region-of-interest scan. Furthermore, cone-beam artifacts, which are inherent to circular scan trajectories, can be reduced significantly. Using measurement objects that can be measured well with a circular trajectory, we found that applying a 3D trajectory leads to dimensional measurement deviations in the same range or even lower than those of a circular trajectory. This suggests that the pose repeatability of the hexapod is sufficient to perform complex scan paths without general loss of accuracy. The obtained results could be relevant for end users of conventional CT scanners, as upgrading existing devices is in principle possible. The presented investigations form the basis for the application of trajectory optimization algorithms.
- 29 June 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (10) , 105402
Open AccessComplex 3D scan trajectories for industrial cone-beam computed tomography using a hexapod
Industrial x-ray computed tomography (CT) represents an established measurement technique in the field of nondestructive testing and dimensional metrology. However, the measurement accuracy is sometimes limited by measurement artifacts that cannot be avoided using a standard circular scan trajectory. This problem can be addressed with the aid of flexible 3D trajectories, but up to date, the application of these is mainly restricted to special CT devices using robot arms. In this paper, we present results using a hexapod as an additional positioning system in a commercial industrial CT scanner. In addition to the 360∘rotation, task-specific tilting of the part during the scan is possible in this way. We used and adapted geometry calibration procedures based on a multi-sphere reference object to enable reconstruction with high accuracy. Using a demonstrator test fixture with high absorbing elements, we show that severe metal and truncation artifacts can be avoided for a region-of-interest scan. Furthermore, cone-beam artifacts, which are inherent to circular scan trajectories, can be reduced significantly. Using measurement objects that can be measured well with a circular trajectory, we found that applying a 3D trajectory leads to dimensional measurement deviations in the same range or even lower than those of a circular trajectory. This suggests that the pose repeatability of the hexapod is sufficient to perform complex scan paths without general loss of accuracy. The obtained results could be relevant for end users of conventional CT scanners, as upgrading existing devices is in principle possible. The presented investigations form the basis for the application of trajectory optimization algorithms.