Siddhant Thakur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Siddhant Thakur has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Brian Christopher Werner
Department of Orthopaedic Surgery, University of Virginia Health System, Charlottesville, Virginia, USA
5 shared publications Nick Metcalfe
5 shared publicationsDavid Knopf
4 shared publicationsJohn M. Tokish
2 shared publications- Patrick J. Denard
Southern Oregon Orthopedics, Medford, OR, USA
2 shared publications - Stefan Greiner
Sporthopaedicum Regensburg, Regensburg, Germany; Department of Trauma Surgery, University Hospital Regensburg, Regensburg, Germany
2 shared publications
Latest Publications
- 13 August 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (2) , e233-e242
Individualizing glenoid lateralization to optimize range of motion after reverse shoulder arthroplasty with the Arthrex Univers reverse: a virtual assessment of the influence of scapular neck length using a statistical shape model
- 13 August 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (2) , e233-e242
Individualizing glenoid lateralization to optimize range of motion after reverse shoulder arthroplasty with the Arthrex Univers reverse: a virtual assessment of the influence of scapular neck length using a statistical shape model
- 14 June 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (1) , 28-39
Scapula anatomy influences simulated impingement-free range of motion in reverse shoulder arthroplasty
- 14 June 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (1) , 28-39
Scapula anatomy influences simulated impingement-free range of motion in reverse shoulder arthroplasty
- 1 March 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (10) , 2480-2486
Glenoid version and inclination can be accurately predicted for shoulder arthroplasty from preoperative computed tomography scans using Virtual Implant Positioning despite missing inferior angle data using statistical shape modeling
- 1 March 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (10) , 2480-2486
Glenoid version and inclination can be accurately predicted for shoulder arthroplasty from preoperative computed tomography scans using Virtual Implant Positioning despite missing inferior angle data using statistical shape modeling
- 14 August 2020
- Published by Taylor & Francis in Numerical Heat Transfer, Part A: Applications
- Vol. 78 (12) , 706-716
Thermal analysis of intraocular electronic display projector visual prosthesis
Corneal opacity is a leading cause of blindness, accounting for about 4% of global blindness. With corneal opacity, light is unable to pass through the cornea to form a clear image on the retina, resulting in blindness. To address this condition, an intraocular projection device has been designed. This device, while in use, would produce heat. According to international standard regulations, the temperature on the surface of the tissues should not increase more than 2° C due to medical devices. In order to establish the power budget of this intraocular electronic device, a steady state thermal finite element analysis was conducted on two different eye models. The device was placed at 9.98 mm from the retina, and was seen to run up to a maximum power of 82 mW for the first model and 91 mW for the second model. To reduce heating of tissues, the device was extended by 0.5 mm to create an air gap which acted as an insulator. The temperature in the nearest living tissue then dropped below the prescribed limit of 2° C at 100 mW.
- 14 August 2020
- Published by Taylor & Francis in Numerical Heat Transfer, Part A: Applications
- Vol. 78 (12) , 706-716
Thermal analysis of intraocular electronic display projector visual prosthesis
Corneal opacity is a leading cause of blindness, accounting for about 4% of global blindness. With corneal opacity, light is unable to pass through the cornea to form a clear image on the retina, resulting in blindness. To address this condition, an intraocular projection device has been designed. This device, while in use, would produce heat. According to international standard regulations, the temperature on the surface of the tissues should not increase more than 2° C due to medical devices. In order to establish the power budget of this intraocular electronic device, a steady state thermal finite element analysis was conducted on two different eye models. The device was placed at 9.98 mm from the retina, and was seen to run up to a maximum power of 82 mW for the first model and 91 mW for the second model. To reduce heating of tissues, the device was extended by 0.5 mm to create an air gap which acted as an insulator. The temperature in the nearest living tissue then dropped below the prescribed limit of 2° C at 100 mW.