Julio César Rincón Martínez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Julio César Rincón Martínez has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Elizabeth Martínez-Bermúdez
Universidad Autónoma de Baja California. Ensenada (México) Facultad de Ingeniería, Arquitectura y Diseño Programa de Doctorado en Arquitectura, Urbanismo y Diseño
2 shared publications Francisco Fernández Melchor
Facultad de Ingeniería, Arquitectura y Diseño, Universidad Autónoma de Baja California, Carretera Transpeninsular Ensenada-Tijuana No. 3917, Zona Playitas, CP. 22860 Ensenada, Baja California, México
2 shared publications- Gonzalo Bojórquez Morales
Universidad Autónoma de Baja California
2 shared publications Ambríz-García J. J.
Facultad de Ingeniería, Arquitectura y Diseño, Universidad Autónoma de Baja California, Ensenada, Baja California, 22860, México
1 shared publication- Armando Núñez de Anda
Autonomous University of Sinaloa
1 shared publication - Armando Núñez-De Anda1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by Editorial Universidad Catolica de Colombia in Revista de Arquitectura (Bogotá)
- Vol. 27 (1) , 177-194
EHDaP: herramienta informática para el procesamiento de datos en estudios de habitabilidad ambiental
En investigaciones relacionadas con la habitabilidad ambiental, la inversión de recursos humanos, tecnológicos, económicos y de temporalidad depositados en la etapa de análisis de datos puede ser onerosa, pues depende directamente del software y el método estadístico que se utilicen, así como de la cantidad de variables físicas y votos subjetivos de confort por correlacionar. El Environmental Habitability Data Processor (EHDaP) es una herramienta informática configurada para procesar, de forma sencilla y eficiente, los datos de estudios de habitabilidad ambiental, a partir de tres métodos de correlación: regresión lineal simple, medias por intervalos de sensación térmica y ANSI/ASHARAE 55. Su diseño se basa en la configuración de un libro de cálculo que utilizasimultáneamente funciones, gráficos y macros para correlacionar numérica y gráficamente las variables. Para ello, una vez que el analista introduce la base de datos, la herramienta la procesa sistemáticamente a partir de tres fases: tratamiento de la base de datos, correlación de las variables y estimación de indicadores ambientales. Lo anterior sugiere una eficiencia importante en los recursos empleados para el procesamiento de datos, permitiendo enfocarse en la metodología del estudio y la consolidación de la base de datos recabada. Los resultados que se obtienen con el EHDaP presentan una alta confiabilidad al contrastarse con los obtenidos en investigaciones recientes que emplean los métodos antes mencionados.
- 1 January 2025
- Published by Editorial Universidad Catolica de Colombia in Revista de Arquitectura (Bogotá)
- Vol. 27 (1) , 177-194
Open AccessEHDaP: herramienta informática para el procesamiento de datos en estudios de habitabilidad ambiental
En investigaciones relacionadas con la habitabilidad ambiental, la inversión de recursos humanos, tecnológicos, económicos y de temporalidad depositados en la etapa de análisis de datos puede ser onerosa, pues depende directamente del software y el método estadístico que se utilicen, así como de la cantidad de variables físicas y votos subjetivos de confort por correlacionar. El Environmental Habitability Data Processor (EHDaP) es una herramienta informática configurada para procesar, de forma sencilla y eficiente, los datos de estudios de habitabilidad ambiental, a partir de tres métodos de correlación: regresión lineal simple, medias por intervalos de sensación térmica y ANSI/ASHARAE 55. Su diseño se basa en la configuración de un libro de cálculo que utilizasimultáneamente funciones, gráficos y macros para correlacionar numérica y gráficamente las variables. Para ello, una vez que el analista introduce la base de datos, la herramienta la procesa sistemáticamente a partir de tres fases: tratamiento de la base de datos, correlación de las variables y estimación de indicadores ambientales. Lo anterior sugiere una eficiencia importante en los recursos empleados para el procesamiento de datos, permitiendo enfocarse en la metodología del estudio y la consolidación de la base de datos recabada. Los resultados que se obtienen con el EHDaP presentan una alta confiabilidad al contrastarse con los obtenidos en investigaciones recientes que emplean los métodos antes mencionados.
- 1 July 2024
- Published by Universidad Nacional Autonoma de Mexico in Ingeniería Investigación y Tecnología
- Vol. 25 (3) , 1-11
Confort térmico adaptativo en cañón urbano: El caso de un clima mediterráneo
La naturaleza física del entorno urbano da lugar al fenomeno de la isla de calor urbana (ICU), lo que propicia que el ambiente térmico de las ciudades sea incómodo al aumentar la temperatura del aire (Ta) aproximadamente 0.4 °C al año. Al carecer de un ambiente térmico adecuado, se limita el uso de los espacios exteriores. Dichos efectos dejan en evidencia la importancia de estudiar las condiciones de confort térmico exterior, para establecer las bases que permitan la toma de decisiones en el proceso de diseño y planificación urbana. El objetivo de la investigación consistió en evaluar el confort térmico adaptativo a través de la sensación térmica del peatón de un cañón urbano en un área residencial. El estudio se realizó durante el período de transición de frío a cálido (primavera) en Ensenada, Baja California, México. Se desarrolló un estudio correlacional, donde se midieron distintas variables fisicas del ambiente térmico (Temperatura de globo negro, temperatura de bulbo seco, humedad relativa y velocidad del aire) y se aplicaron encuestas sobre sensación térmica, de las cuales se obtuvieron 211 observaciones, 114 (54.1 %) fueron respuestas de hombres y 97 (45.9 %) fueron respuestas de mujeres, con 18 a 30 años de edad. El análisis de datos se realizó con el método de Medias por Intervalo de Sensación Térmica (MIST), donde se observó el fenómeno de adaptación por el comportamiento de las sensaciones térmicas registradas y los rangos de confort térmico (reducido y extenso) estimados a través de las desviaciones estándar (DS). El rango de confort reducido y extenso para la sensación térmica fue de 2.7 K y 5.4 K respectivamente; para la sensación hígrica fue de 13.2 % y 26.3 % respectivamente; y para la velocidad del viento fue de 2.6 m/s y 4.2 m/s, respectivamente.
- 1 July 2024
- Published by Universidad Nacional Autonoma de Mexico in Ingeniería Investigación y Tecnología
- Vol. 25 (3) , 1-11
Confort térmico adaptativo en cañón urbano: El caso de un clima mediterráneo
La naturaleza física del entorno urbano da lugar al fenomeno de la isla de calor urbana (ICU), lo que propicia que el ambiente térmico de las ciudades sea incómodo al aumentar la temperatura del aire (Ta) aproximadamente 0.4 °C al año. Al carecer de un ambiente térmico adecuado, se limita el uso de los espacios exteriores. Dichos efectos dejan en evidencia la importancia de estudiar las condiciones de confort térmico exterior, para establecer las bases que permitan la toma de decisiones en el proceso de diseño y planificación urbana. El objetivo de la investigación consistió en evaluar el confort térmico adaptativo a través de la sensación térmica del peatón de un cañón urbano en un área residencial. El estudio se realizó durante el período de transición de frío a cálido (primavera) en Ensenada, Baja California, México. Se desarrolló un estudio correlacional, donde se midieron distintas variables fisicas del ambiente térmico (Temperatura de globo negro, temperatura de bulbo seco, humedad relativa y velocidad del aire) y se aplicaron encuestas sobre sensación térmica, de las cuales se obtuvieron 211 observaciones, 114 (54.1 %) fueron respuestas de hombres y 97 (45.9 %) fueron respuestas de mujeres, con 18 a 30 años de edad. El análisis de datos se realizó con el método de Medias por Intervalo de Sensación Térmica (MIST), donde se observó el fenómeno de adaptación por el comportamiento de las sensaciones térmicas registradas y los rangos de confort térmico (reducido y extenso) estimados a través de las desviaciones estándar (DS). El rango de confort reducido y extenso para la sensación térmica fue de 2.7 K y 5.4 K respectivamente; para la sensación hígrica fue de 13.2 % y 26.3 % respectivamente; y para la velocidad del viento fue de 2.6 m/s y 4.2 m/s, respectivamente.
- Open Access
- 1 July 2024
- Published by Editorial Universidad Catolica de Colombia in Revista de Arquitectura (Bogotá)
- Vol. 26 (2) , 151-166
Estimación del confort térmico en espacios exteriores: evaluación del periodo frío en Ensenada, Baja California
Los estudios del confort térmico en espacios exteriores son fundamentales para favorecer la habitabilidad de los espacios abiertos y mejorar las condiciones de vida de las personas; sin embargo, es necesario que sean producto de las características locales y de las personas del sitio donde se desarrollan los estudios. El objetivo de este trabajo es evaluar la sensación térmica humana durante el periodo frío, con el fin de estimar los rangos de confort térmico para espacios exteriores que permitan ofrecer indicadores de diseño. Para ello, se recabaron observaciones en diversos tipos de espacios abiertos de la ciudad de Ensenada, única en México con clima mediterráneo, con inviernos fríos y húmedos. La evaluación se realizó mediante el enfoque adaptativo y se procesó con el método de Medias por Intervalos de Sensación Térmica (MIST). Se realizó un análisis correlacional respecto a la sensación térmica con las variables climáticas de temperatura del aire, humedad relativa y velocidad de viento. El rango de confort térmico fue de 12,6 ºC a 23,8 ºC, valores por debajo de los rangos anuales estimados para regiones climáticas mediterráneas (21,1 ºC-29,2 ºC y 20 ºC-25 ºC) en el mismo periodo de estudio.
- 1 July 2024
- Published by Editorial Universidad Catolica de Colombia in Revista de Arquitectura (Bogotá)
- Vol. 26 (2) , 151-166
Open AccessEstimación del confort térmico en espacios exteriores: evaluación del periodo frío en Ensenada, Baja California
Los estudios del confort térmico en espacios exteriores son fundamentales para favorecer la habitabilidad de los espacios abiertos y mejorar las condiciones de vida de las personas; sin embargo, es necesario que sean producto de las características locales y de las personas del sitio donde se desarrollan los estudios. El objetivo de este trabajo es evaluar la sensación térmica humana durante el periodo frío, con el fin de estimar los rangos de confort térmico para espacios exteriores que permitan ofrecer indicadores de diseño. Para ello, se recabaron observaciones en diversos tipos de espacios abiertos de la ciudad de Ensenada, única en México con clima mediterráneo, con inviernos fríos y húmedos. La evaluación se realizó mediante el enfoque adaptativo y se procesó con el método de Medias por Intervalos de Sensación Térmica (MIST). Se realizó un análisis correlacional respecto a la sensación térmica con las variables climáticas de temperatura del aire, humedad relativa y velocidad de viento. El rango de confort térmico fue de 12,6 ºC a 23,8 ºC, valores por debajo de los rangos anuales estimados para regiones climáticas mediterráneas (21,1 ºC-29,2 ºC y 20 ºC-25 ºC) en el mismo periodo de estudio.
- 1 January 2024
- Published by Universidad Nacional Autonoma de Mexico in Ingeniería Investigación y Tecnología
- Vol. 25 (1) , 1-12
Confort higrotérmico en espacios públicos abiertos de clima mediterráneo en periodo de transición térmica
Con base en el incremento histórico sostenido en las temperaturas globales, organismos internacionales enfatizan la obligación de gestionar medidas de mitigación y adaptación, por lo tanto, se fundamenta el evaluar el confort higrotérmico en el cual usuarios de espacios de uso colectivo desarrollan sus actividades. El objetivo del presente trabajo es estimar el confort higrotérmico para espacios públicos abiertos, en la ciudad de Ensenada, Baja California, quien presenta un clima mediterráneo y un bioclima templado seco, respectivamente. El periodo evaluado es de transición frío-cálido, a partir de las bases metodológicas del enfoque de estudio adaptativo, con el que se recabaron 221 observaciones con actividad predominantemente pasiva (68 %). Con lo anterior, se estimaron los valores de neutralidad y los rangos de confort extenso como a continuación se indica: 20.1 °C y de 15.4-26.0 °C para la temperatura; 58.4 % y de 35.6-79.3 % para la humedad relativa; 1.52 m/s y de 0.35-2.69 m/s para la velocidad del viento, respectivamente. Estos resultados fueron comparados con base en una interpolación realizada en Meteonorm 7.0 para un periodo de 1990-2010, los cuales mostraron diferencias reducidas de 0.3 °C entre los valores obtenidos y los comparados para temperatura, 2.1 % para la humedad, y 0.2 m/s para la velocidad de viento. Por lo tanto, se evidencia la aportación de obtener estimaciones directamente en campo en las que el enfoque adaptativo representa una amplitud consistente a las condiciones del sitio para obtener indicadores ambientales que contribuyan a la confortabilidad higrotérmica de los espacios abiertos.
- 1 January 2024
- Published by Universidad Nacional Autonoma de Mexico in Ingeniería Investigación y Tecnología
- Vol. 25 (1) , 1-12
Confort higrotérmico en espacios públicos abiertos de clima mediterráneo en periodo de transición térmica
Con base en el incremento histórico sostenido en las temperaturas globales, organismos internacionales enfatizan la obligación de gestionar medidas de mitigación y adaptación, por lo tanto, se fundamenta el evaluar el confort higrotérmico en el cual usuarios de espacios de uso colectivo desarrollan sus actividades. El objetivo del presente trabajo es estimar el confort higrotérmico para espacios públicos abiertos, en la ciudad de Ensenada, Baja California, quien presenta un clima mediterráneo y un bioclima templado seco, respectivamente. El periodo evaluado es de transición frío-cálido, a partir de las bases metodológicas del enfoque de estudio adaptativo, con el que se recabaron 221 observaciones con actividad predominantemente pasiva (68 %). Con lo anterior, se estimaron los valores de neutralidad y los rangos de confort extenso como a continuación se indica: 20.1 °C y de 15.4-26.0 °C para la temperatura; 58.4 % y de 35.6-79.3 % para la humedad relativa; 1.52 m/s y de 0.35-2.69 m/s para la velocidad del viento, respectivamente. Estos resultados fueron comparados con base en una interpolación realizada en Meteonorm 7.0 para un periodo de 1990-2010, los cuales mostraron diferencias reducidas de 0.3 °C entre los valores obtenidos y los comparados para temperatura, 2.1 % para la humedad, y 0.2 m/s para la velocidad de viento. Por lo tanto, se evidencia la aportación de obtener estimaciones directamente en campo en las que el enfoque adaptativo representa una amplitud consistente a las condiciones del sitio para obtener indicadores ambientales que contribuyan a la confortabilidad higrotérmica de los espacios abiertos.
- Open Access
- 1 January 2024
- Published by Universidad de Guadalajara in Vivienda y Comunidades Sustentables
- No. 15,p. 81-100
Una aproximación a la minería de datos para estimar indicadores de confort térmico con métodos diversos
Los hallazgos del estudio del confort térmico para espacios interiores son difundidos en documentos que regularmente profundizan en la metodología aplicada y los resultados obtenidos, sin embargo, la explicación relacionada con el análisis de datos para llegar a éstos, generalmente es reducida. El fenómeno del confort térmico adaptativo comúnmente es interpretado a partir de métodos estadísticos de tipo univariable que, por lo regular, se basan en la regresión lineal simple o en el método de Medias por Intervalos de Sensación Térmica; aunque también es posible encontrar estudios que utilizan el método gráfico de ANSI/ASHRAE 55. El objetivo de este documento es describir la minería de datos con la que se procesan estadísticamente los datos a partir de diversos métodos de análisis. Para ello, con base en la consulta de diferentes investigaciones relacionadas con el confort térmico se definieron los métodos más utilizados en sus etapas de tratamiento y correlación de datos, se investigó su fundamento teórico y se aplicaron a un caso hipotético. Lo anterior permitió identificar que el método de Medias por Intervalos de Sensación Térmica ofrece resultados con mayor consistencia dada la interpretación causal-fenomenológica que permite respecto a la relación entre la sensación térmica percibida y las condiciones del ambiente térmico.
- 1 January 2024
- Published by Universidad de Guadalajara in Vivienda y Comunidades Sustentables
- No. 15,p. 81-100
Open AccessUna aproximación a la minería de datos para estimar indicadores de confort térmico con métodos diversos
Los hallazgos del estudio del confort térmico para espacios interiores son difundidos en documentos que regularmente profundizan en la metodología aplicada y los resultados obtenidos, sin embargo, la explicación relacionada con el análisis de datos para llegar a éstos, generalmente es reducida. El fenómeno del confort térmico adaptativo comúnmente es interpretado a partir de métodos estadísticos de tipo univariable que, por lo regular, se basan en la regresión lineal simple o en el método de Medias por Intervalos de Sensación Térmica; aunque también es posible encontrar estudios que utilizan el método gráfico de ANSI/ASHRAE 55. El objetivo de este documento es describir la minería de datos con la que se procesan estadísticamente los datos a partir de diversos métodos de análisis. Para ello, con base en la consulta de diferentes investigaciones relacionadas con el confort térmico se definieron los métodos más utilizados en sus etapas de tratamiento y correlación de datos, se investigó su fundamento teórico y se aplicaron a un caso hipotético. Lo anterior permitió identificar que el método de Medias por Intervalos de Sensación Térmica ofrece resultados con mayor consistencia dada la interpretación causal-fenomenológica que permite respecto a la relación entre la sensación térmica percibida y las condiciones del ambiente térmico.
- Open Access
- 28 February 2023
- Published by IntechOpen
Indoor Thermal Comfort from the Estimation Thermal Environment’s Physical Variables in Temperate-Dry Bioclimate
Adverse thermal conditions alter the indoor habitability and, consequently, the occupants health, performance, mood, and comfort. Although there are local regulations that provide thermal indicators for the indoor architectural design, these are usually unrelated to the climate, type of construction project, and psychophysiological adaptation of people. In this way, this chapter shows the thermal comfort ranges estimated from the thermal environments physical variables, using the adaptive approach, for Ensenada City, Mexico (temperate-dry bioclimate). Surveys were applied to collect the subjective perception simultaneously with the measurement of black globe temperature, air temperature, relative humidity, and wind speed. Study sample was made up from students of a public university whose activity level is sedentary (1.2 met) and clothing is light (0.7 clo). The survey was designed based on the ISO 10551 and ANSI/ASHRAE 55 standards, while the physical measurement instruments were selected based on ISO 7726, managing to generate a class I database. The study was correlational and statistically analyzed with 3750 surveys from the average by thermal sensation intervals method. 16 comfort ranges were quantitatively and graphically estimated from the four physical variables analyzed in each of the four representative thermal periods of the city. These indicators offer objective knowledge for proper decision-making during the architectural design process and therefore for the thermal-energy efficiency of buildings.
- 28 February 2023
- Published by IntechOpen
Open AccessIndoor Thermal Comfort from the Estimation Thermal Environment’s Physical Variables in Temperate-Dry Bioclimate
Adverse thermal conditions alter the indoor habitability and, consequently, the occupants health, performance, mood, and comfort. Although there are local regulations that provide thermal indicators for the indoor architectural design, these are usually unrelated to the climate, type of construction project, and psychophysiological adaptation of people. In this way, this chapter shows the thermal comfort ranges estimated from the thermal environments physical variables, using the adaptive approach, for Ensenada City, Mexico (temperate-dry bioclimate). Surveys were applied to collect the subjective perception simultaneously with the measurement of black globe temperature, air temperature, relative humidity, and wind speed. Study sample was made up from students of a public university whose activity level is sedentary (1.2 met) and clothing is light (0.7 clo). The survey was designed based on the ISO 10551 and ANSI/ASHRAE 55 standards, while the physical measurement instruments were selected based on ISO 7726, managing to generate a class I database. The study was correlational and statistically analyzed with 3750 surveys from the average by thermal sensation intervals method. 16 comfort ranges were quantitatively and graphically estimated from the four physical variables analyzed in each of the four representative thermal periods of the city. These indicators offer objective knowledge for proper decision-making during the architectural design process and therefore for the thermal-energy efficiency of buildings.
- Open Access
- 1 January 2023
- Published by Editorial Universidad Catolica de Colombia in Revista de Arquitectura (Bogotá)
- Vol. 25 (1) , 12-24
Confort térmico en edificios educativos naturalmente ventilados: un estudio en bioclima templado-seco
El bienestar, la eficiencia y el confort de las personas pueden verse afectados por las condiciones adversas del ambiente térmico. En México, los estudios que abordan dicho fenómeno se han desarrollado principalmente en sitios con bioclimas cálidos (seco y húmedo), y poca investigación hay sobre bioclimas templados o semifríos. Este trabajo presenta los resultados de un estudio sobre confort térmico desarrollado con el enfoque adaptativo, en edificios naturalmente ventilados, durante la transición térmica del periodo frío al periodo cálido en Ensenada, Baja California (bioclima templado-seco). El estudio es de tipo correlacional y fue analizado con 987 evaluaciones y el registro simultáneo de la temperatura, la humedad relativa y la velocidad de viento, durante el periodo del 24 de abril al 22 de mayo de 2017. Los cuestionarios aplicados se diseñaron con la ISO 10551 y la ANSI/ASHRAE 55; asimismo, los instrumentos de medición responden a la ISO 7726. Los datos recabados fueron procesados estadísticamente con el método de medias por intervalos de sensación térmica. La temperatura neutra resultó en 20,2 °C, con un rango de confort de 17,7 °C-22,7 °C; los sujetos reflejaron mayor adaptación a temperaturas por encima de la temperatura neutra, a partir del emprendimiento de acciones voluntarias o involuntarias cuyo objetivo se enfocaba en reanudar el confort térmico de forma inmediata.
- 1 January 2023
- Published by Editorial Universidad Catolica de Colombia in Revista de Arquitectura (Bogotá)
- Vol. 25 (1) , 12-24
Open AccessConfort térmico en edificios educativos naturalmente ventilados: un estudio en bioclima templado-seco
El bienestar, la eficiencia y el confort de las personas pueden verse afectados por las condiciones adversas del ambiente térmico. En México, los estudios que abordan dicho fenómeno se han desarrollado principalmente en sitios con bioclimas cálidos (seco y húmedo), y poca investigación hay sobre bioclimas templados o semifríos. Este trabajo presenta los resultados de un estudio sobre confort térmico desarrollado con el enfoque adaptativo, en edificios naturalmente ventilados, durante la transición térmica del periodo frío al periodo cálido en Ensenada, Baja California (bioclima templado-seco). El estudio es de tipo correlacional y fue analizado con 987 evaluaciones y el registro simultáneo de la temperatura, la humedad relativa y la velocidad de viento, durante el periodo del 24 de abril al 22 de mayo de 2017. Los cuestionarios aplicados se diseñaron con la ISO 10551 y la ANSI/ASHRAE 55; asimismo, los instrumentos de medición responden a la ISO 7726. Los datos recabados fueron procesados estadísticamente con el método de medias por intervalos de sensación térmica. La temperatura neutra resultó en 20,2 °C, con un rango de confort de 17,7 °C-22,7 °C; los sujetos reflejaron mayor adaptación a temperaturas por encima de la temperatura neutra, a partir del emprendimiento de acciones voluntarias o involuntarias cuyo objetivo se enfocaba en reanudar el confort térmico de forma inmediata.
- 1 January 2023
- Published by Universidad Nacional Autonoma de Mexico in Ingeniería Investigación y Tecnología
- Vol. 24 (1) , 1-17
Basic methods used for data analysis in adaptive thermal comfort studies
Existing research literature on adaptive thermal comfort studies shows the methodology used and results obtained; however, the information for data analysis is reduced. Methods commonly used to interpret and understand the thermal comfort phenomenon are univariate type and, usually, use the linear regression to predict the behavior of one variable from the variation of other; among others, Simple Linear Regression method and Averages by Thermal Sensation Interval method can be identified, although it is also possible to find studies based on the ANSI/ASHRAE 55 method or on machine-learning algorithms. This document describes a procedure that allows three-stages data to be statistically processed: Database capture, Database preparation, and Data Correlation. In each case, the steps to be followed are specified and different statistical alternatives are indicated to achieve certainty in the results. From different studies specialized in thermal comfort, it is possible to identify that the Averages by Thermal Sensation Interval method offers results with greater consistency and causality regarding the perceived thermal sensation and its phenomenological correspondence with the monitoring of the environmental conditions. As a complementary resource, a personalized spreadsheet whit the three methods described in this paper is including.
- 1 January 2023
- Published by Universidad Nacional Autonoma de Mexico in Ingeniería Investigación y Tecnología
- Vol. 24 (1) , 1-17
Basic methods used for data analysis in adaptive thermal comfort studies
Existing research literature on adaptive thermal comfort studies shows the methodology used and results obtained; however, the information for data analysis is reduced. Methods commonly used to interpret and understand the thermal comfort phenomenon are univariate type and, usually, use the linear regression to predict the behavior of one variable from the variation of other; among others, Simple Linear Regression method and Averages by Thermal Sensation Interval method can be identified, although it is also possible to find studies based on the ANSI/ASHRAE 55 method or on machine-learning algorithms. This document describes a procedure that allows three-stages data to be statistically processed: Database capture, Database preparation, and Data Correlation. In each case, the steps to be followed are specified and different statistical alternatives are indicated to achieve certainty in the results. From different studies specialized in thermal comfort, it is possible to identify that the Averages by Thermal Sensation Interval method offers results with greater consistency and causality regarding the perceived thermal sensation and its phenomenological correspondence with the monitoring of the environmental conditions. As a complementary resource, a personalized spreadsheet whit the three methods described in this paper is including.
- 1 April 2022
- Published by Universidad Nacional Autonoma de Mexico in Ingeniería Investigación y Tecnología
- Vol. 23 (2) , 1-14
Estimación del rango de confort higrotérmico para exteriores en dos bioclimas extremos de México
Los estudios sobre confort térmico desarrollados bajo las bases metodológicas del enfoque adaptativo, advierten una dependencia importante de la sensación térmica de los sujetos respecto a las condiciones climáticas exteriores del lugar habitado. Las condiciones adversas del ambiente térmico pueden influir negativamente en el bienestar, la eficiencia y el confort de los sujetos, lo que deriva en la subutilización de los espacios cuyas condiciones higrotérmicas son inapropiadas para la actividad para la que fueron construidos. El objetivo de este trabajo consiste en estimar el rango de confort higrotérmico para espacios exteriores en dos bioclimas representativamente extremos en México: Cálido-húmedo y Semifrío-seco. El primero presenta una temperatura media anual de 26.2 °C y una precipitación total anual de 1,094.8 mm, mientras que el segundo, una de 17.3 °C y una de 217.3 mm, respectivamente. Los estudios son de tipo correlacional y fueron analizados con 605 evaluaciones y el registro simultáneo de la temperatura, la humedad relativa y la velocidad de viento, durante el periodo cálido. Los cuestionarios aplicados se diseñaron con base en la ISO 10551 y la ANSI/ASHRAE 55; asimismo, los instrumentos de medición física se establecieron a partir de la ISO 7726. Los datos recabados fueron procesados estadísticamente con el método de Medias por Intervalos de Sensación Térmica. El rango de confort higrotérmico estimado para el bioclima Cálido-húmedo fue de 21.8 °C a 34.9 °C para la temperatura y de 38.3 % a 85.8 % para la humedad relativa, mientras que para el Semifrío-seco fue de 19.4 °C a 25.0 °C y de 54.2 % a 84.0 %, respectivamente. Estas estimaciones responden a la adaptación que las personas presentan con su ambiente inmediato, a razón de las condiciones climáticas locales de cada lugar y el periodo de evaluación estudiado.
- 1 April 2022
- Published by Universidad Nacional Autonoma de Mexico in Ingeniería Investigación y Tecnología
- Vol. 23 (2) , 1-14
Estimación del rango de confort higrotérmico para exteriores en dos bioclimas extremos de México
Los estudios sobre confort térmico desarrollados bajo las bases metodológicas del enfoque adaptativo, advierten una dependencia importante de la sensación térmica de los sujetos respecto a las condiciones climáticas exteriores del lugar habitado. Las condiciones adversas del ambiente térmico pueden influir negativamente en el bienestar, la eficiencia y el confort de los sujetos, lo que deriva en la subutilización de los espacios cuyas condiciones higrotérmicas son inapropiadas para la actividad para la que fueron construidos. El objetivo de este trabajo consiste en estimar el rango de confort higrotérmico para espacios exteriores en dos bioclimas representativamente extremos en México: Cálido-húmedo y Semifrío-seco. El primero presenta una temperatura media anual de 26.2 °C y una precipitación total anual de 1,094.8 mm, mientras que el segundo, una de 17.3 °C y una de 217.3 mm, respectivamente. Los estudios son de tipo correlacional y fueron analizados con 605 evaluaciones y el registro simultáneo de la temperatura, la humedad relativa y la velocidad de viento, durante el periodo cálido. Los cuestionarios aplicados se diseñaron con base en la ISO 10551 y la ANSI/ASHRAE 55; asimismo, los instrumentos de medición física se establecieron a partir de la ISO 7726. Los datos recabados fueron procesados estadísticamente con el método de Medias por Intervalos de Sensación Térmica. El rango de confort higrotérmico estimado para el bioclima Cálido-húmedo fue de 21.8 °C a 34.9 °C para la temperatura y de 38.3 % a 85.8 % para la humedad relativa, mientras que para el Semifrío-seco fue de 19.4 °C a 25.0 °C y de 54.2 % a 84.0 %, respectivamente. Estas estimaciones responden a la adaptación que las personas presentan con su ambiente inmediato, a razón de las condiciones climáticas locales de cada lugar y el periodo de evaluación estudiado.
- 1 January 2022
- Published by Universidad Autonoma Metropolitana in Estudios de arquitectura bioclimática
- Vol. 01, 185-198
Intercambiador de Calor Tierra-Aire en Clima Mediterráneo. Periodo Térmico de Transición Frío-Calor
La humedad en espacios interiores genera impactos negativos en toda edificación y estos pueden producir efectos negativos en la salud de los usuarios. La OMS estima que esta afecta del 10-50% de los ambientes interiores en Europa, América del Norte, Australia, India y Japón. Mediante la gestión de los niveles de humedad interior y la condensación a través de un control adecuado de la temperatura y la ventilación, es posible controlar la humedad, garantizar una larga vida útil del edificio y una buena calidad del aire interior. El intercambiador de calor tierra-aire (ICTA) es el dispositivo propuesto, junto con la chimenea solar, para conformar un sistema pasivo que regule las condiciones higrotérmicas que permitan reducir los problemas de humedad en espacios interiores de la vivienda de interés social en clima mediterráneo. Con el análisis psicrométrico del ICTA durante el mes de marzo, se observa que en momentos fríos es cuando se presenta mayor diferencia entre las condiciones higrotérmicas del ambiente exterior con respecto a la salida del ICTA, de 8 ºC en temperatura y 30 % de humedad relativa. Respecto al desempeño higrotérmico, el ICTA presenta una estabilidad térmica en las tres profundidades, entre 17 ºC y 20 ºC, y una ligera diferencia con respecto a la salida del mismo; en los momentos fríos se observa una diferencia de casi 10 ºC entre el intercambiador en sus tres profundidades y la temperatura ambiente. Los días con mayores temperaturas, la temperatura en la salida del ICTA se encuentra dentro de la zona de confort (entre 17,7 ºC y 22,7 ºC para el periodo de transición de frío a cálido), mientras que en días fríos las temperaturas se encuentran cercanas al límite inferior. Por su parte, la humedad relativa se mantiene cercano al 60 % durante todo el mes.
- 1 January 2022
- Published by Universidad Autonoma Metropolitana in Estudios de arquitectura bioclimática
- Vol. 01, 185-198
Intercambiador de Calor Tierra-Aire en Clima Mediterráneo. Periodo Térmico de Transición Frío-Calor
La humedad en espacios interiores genera impactos negativos en toda edificación y estos pueden producir efectos negativos en la salud de los usuarios. La OMS estima que esta afecta del 10-50% de los ambientes interiores en Europa, América del Norte, Australia, India y Japón. Mediante la gestión de los niveles de humedad interior y la condensación a través de un control adecuado de la temperatura y la ventilación, es posible controlar la humedad, garantizar una larga vida útil del edificio y una buena calidad del aire interior. El intercambiador de calor tierra-aire (ICTA) es el dispositivo propuesto, junto con la chimenea solar, para conformar un sistema pasivo que regule las condiciones higrotérmicas que permitan reducir los problemas de humedad en espacios interiores de la vivienda de interés social en clima mediterráneo. Con el análisis psicrométrico del ICTA durante el mes de marzo, se observa que en momentos fríos es cuando se presenta mayor diferencia entre las condiciones higrotérmicas del ambiente exterior con respecto a la salida del ICTA, de 8 ºC en temperatura y 30 % de humedad relativa. Respecto al desempeño higrotérmico, el ICTA presenta una estabilidad térmica en las tres profundidades, entre 17 ºC y 20 ºC, y una ligera diferencia con respecto a la salida del mismo; en los momentos fríos se observa una diferencia de casi 10 ºC entre el intercambiador en sus tres profundidades y la temperatura ambiente. Los días con mayores temperaturas, la temperatura en la salida del ICTA se encuentra dentro de la zona de confort (entre 17,7 ºC y 22,7 ºC para el periodo de transición de frío a cálido), mientras que en días fríos las temperaturas se encuentran cercanas al límite inferior. Por su parte, la humedad relativa se mantiene cercano al 60 % durante todo el mes.